Normalized to: Dipper, N.
[1]
oai:arXiv.org:1603.07527 [pdf] - 1392956
Experience with wavefront sensor and deformable mirror interfaces for
wide-field adaptive optics systems
Basden, A. G.;
Atkinson, D.;
Bharmal, N. A.;
Bitenc, U.;
Brangier, M.;
Buey, T.;
Butterley, T.;
Cano, D.;
Chemla, F.;
Clark, P.;
Cohen, M.;
Conan, J. -M.;
de Cos, F. J.;
Dickson, C.;
Dipper, N. A.;
Dunlop, C. N.;
Feautrier, P.;
Fusco, T.;
Gach, J. L.;
Gendron, E.;
Geng, D.;
Goodsell, S. J.;
Gratadour, D.;
Greenaway, A. H.;
Guesalaga, A.;
Guzman, C. D.;
Henry, D.;
Holck, D.;
Hubert, Z.;
Huet, J. M.;
Kellerer, A.;
Kulcsar, C.;
Laporte, P.;
Roux, B. Le;
Looker, N.;
Longmore, A. J.;
Marteaud, M.;
Martin, O.;
Meimon, S.;
Morel, C.;
Morris, T. J.;
Myers, R. M.;
Osborn, J.;
Perret, D.;
Petit, C.;
Raynaud, H.;
Reeves, A. P.;
Rousset, G.;
Lasheras, F. Sanchez;
Rodriguez, M. Sanchez;
Santos, J. D.;
Sevin, A.;
Sivo, G.;
Stadler, E.;
Stobie, B.;
Talbot, G.;
Todd, S.;
Vidal, F.;
Younger, E. J.
Submitted: 2016-03-24
Recent advances in adaptive optics (AO) have led to the implementation of
wide field-of-view AO systems. A number of wide-field AO systems are also
planned for the forthcoming Extremely Large Telescopes. Such systems have
multiple wavefront sensors of different types, and usually multiple deformable
mirrors (DMs).
Here, we report on our experience integrating cameras and DMs with the
real-time control systems of two wide-field AO systems. These are CANARY, which
has been operating on-sky since 2010, and DRAGON, which is a laboratory
adaptive optics real-time demonstrator instrument. We detail the issues and
difficulties that arose, along with the solutions we developed. We also provide
recommendations for consideration when developing future wide-field AO systems.
[2]
oai:arXiv.org:1406.6008 [pdf] - 841191
Analysis of on-sky MOAO performance of CANARY using natural guide stars
Vidal, Fabrice;
Gendron, Eric;
Rousset, Gerard;
Morris, Tim;
Basden, Alastair;
Myers, Richard;
Brangier, Matthieu;
Chemla, Fanny;
Dipper, Nigel;
Gratadour, Damien;
Henry, David;
Hubert, Zoltan;
Longmore, Andy;
Martin, Olivier;
Talbot, Gordon;
Younger, Eddy
Submitted: 2014-06-23
The first on-sky results obtained by CANARY, the Multi-Object Adaptive Optics
(MOAO) demonstrator, are analysed. The data were recorded at the William
Herschel Telescope, at the end of September 2010. We describe the command and
calibrations algorithms used during the run and present the observing
conditions. The processed data are MOAO-loop engaged or disengaged slope
buffers, comprising the synchronised measurements of the four Natural Guide
Stars (NGS) wavefront sensors running in parallel, and near Infra-Red (IR)
images. We describe the method we use to establish the error budget of CANARY.
We are able to evaluate the to- mographic and the open loop errors, having
median values around 216 nm and 110 nm respectively. In addition, we identify
an unexpected residual quasi-static field aberration term of mean value 110 nm.
We present the detailed error budget analysed for three sets of data for three
different asterisms. We compare the experimental budgets with the numerically
simulated ones and demonstrate a good agreement. We find also a good agreement
between the computed error budget from the slope buffers and the measured
Strehl ratio on the IR images, ranging between 10% and 20% at 1 530 nm. These
results make us confident in our ability to establish the error budget of
future MOAO instruments.
[3]
oai:arXiv.org:1006.3102 [pdf] - 190657
The Fibre Multi-Object Spectrograph (FMOS) for Subaru Telescope
Kimura, Masahiko;
Maihara, Toshinori;
Iwamuro, Fumihide;
Akiyama, Masayuki;
Tamura, Naoyuki;
Dalton, Gavin B.;
Takato, Naruhisa;
Tait, Philip;
Ohta, Kouji;
Eto, Shigeru;
Mochida, Daisaku;
Elms, Brian;
Kawate, Kaori;
Kurakami, Tomio;
Moritani, Yuuki;
Noumaru, Junichi;
Ohshima, Norio;
Sumiyoshi, Masanao;
Yabe, Kiyoto;
Brzeski, Jurek;
Farrell, Tony;
Frost, Gabriella;
Gillingham, Peter R.;
Haynes, Roger;
Moore, Anna M.;
Muller, Rolf;
Smedley, Scott;
Smith, Greg;
Bonfield, David G.;
Brooks, Charles B.;
Holmes, Alan R.;
Lake, Emma Curtis;
Lee, Hanshin;
Lewis, Ian J.;
Froud, Tim R.;
Tosh, Ian A.;
Woodhouse, Guy F.;
Blackburn, Colin;
Dipper, Nigel;
Murray, Graham;
Sharples, Ray;
Robertson, David J.
Submitted: 2010-06-15
Fibre Multi-Object Spectrograph (FMOS) is the first near-infrared instrument
with a wide field of view capable of acquiring spectra simultaneously from up
to 400 objects. It has been developed as a common-use instrument for the F/2
prime-focus of the Subaru Telescope. The field coverage of 30' diameter is
achieved using a new 3-element corrector optimized in the near-infrared
(0.9-1.8um) wavelength range. Due to limited space at the prime-focus, we have
had to develop a novel fibre positioner called "Echidna" together with two
OH-airglow suppressed spectrographs. FMOS consists of three subsystems: the
prime focus unit for IR, the fibre positioning system/connector units, and the
two spectrographs. After full systems integration, FMOS was installed on the
telescope in late 2007. Many aspects of performance were checked through
various test and engineering observations. In this paper, we present the
optical and mechanical components of FMOS and show the results of our on-sky
engineering observations to date.
[4]
oai:arXiv.org:1002.2077 [pdf] - 1025099
EAGLE multi-object AO concept study for the E-ELT
Rousset, G.;
Fusco, T.;
Assemat, F.;
Morris, T.;
Gendron, E.;
Myers, R.;
Brangier, M.;
Cohen, M.;
Dipper, N.;
Evans, C.;
Gratadour, D.;
Jagourel, P.;
Laporte, P.;
Mignant, D. Le;
Puech, M.;
Robert, C.;
Schnetler, H.;
Taylor, W.;
Vidal, F.;
Cuby, J. -G.;
Lehnert, M.;
Morris, S.;
Parr-Burman, P.
Submitted: 2010-02-10
EAGLE is the multi-object, spatially-resolved, near-IR spectrograph
instrument concept for the E-ELT, relying on a distributed Adaptive Optics,
so-called Multi Object Adaptive Optics. This paper presents the results of a
phase A study. Using 84x84 actuator deformable mirrors, the performed analysis
demonstrates that 6 laser guide stars and up to 5 natural guide stars of
magnitude R<17, picked-up in a 7.3' diameter patrol field of view, allow us to
obtain an overall performance in terms of Ensquared Energy of 35% in a 75x75
mas^2 spaxel at H band, whatever the target direction in the centred 5' science
field for median seeing conditions. The computed sky coverage at galactic
latitudes |b|~60 is close to 90%.
[5]
oai:arXiv.org:astro-ph/0609069 [pdf] - 260784
Cryogenic tests of volume-phase holographic gratings: results at 100 K
Submitted: 2006-09-04
We present results from cryogenic tests of Volume-Phase Holographic(VPH)
gratings at 100 K. The aims of these tests are to see whether the diffraction
efficiency as a function of wavelength is significantly different at a low
temperature from that at room temperature and to see how the performance of a
VPH grating is affected by a number of thermal cycles. We have completed 10
cycles between room temperature and 100 $K$, and find no clear evidence that
the diffraction efficiency changes with temperature or with successive thermal
cycle.
[6]
oai:arXiv.org:astro-ph/0311517 [pdf] - 61097
Cryogenic Tests of Volume-Phase Holographic Gratings: I. Results at 200
K
Submitted: 2003-11-22
We present results from cryogenic tests of a Volume-Phase Holographic (VPH)
grating at 200 K measured at near-infrared wavelengths. The aims of these tests
were to see whether the diffraction efficiency and angular dispersion of a VPH
grating are significantly different at a low temperature from those at a room
temperature, and to see how many cooling and heating cycles the grating can
withstand. We have completed 5 cycles between room temperature and 200 K, and
find that the performance is nearly independent of temperature, at least over
the temperature range which we are investigating. In future, we will not only
try more cycles between these temperatures but also perform measurements at a
much lower temperature (e.g., 80 K).
[7]
oai:arXiv.org:astro-ph/9804224 [pdf] - 101105
TeV gamma rays from PSR 1706-44
Chadwick, P. M.;
Dickinson, M. R.;
Dipper, N. A.;
Holder, J.;
Kendall, T. R.;
McComb, T. J. L.;
Orford, K. J.;
Osborne, J. L.;
Rayner, S. M.;
Roberts, I. D.;
Shaw, S. E.;
Turver, K. E.
Submitted: 1998-04-22
Observations made with the University of Durham Mark 6 atmospheric Cerenkov
telescope confirm that PSR B1706-44 is a very high energy gamma-ray emitter.
There is no indication from our dataset that the very high energy gamma-rays
are pulsed, in contrast to the findings at < 20 GeV, which indicate that more
than 80% of the flux is pulsed. The flux at E > 300 GeV is estimated to be (3.9
+/- 0.7 (statistical)) x 10^-11 cm^-2 s^-1.
[8]
oai:arXiv.org:astro-ph/9804212 [pdf] - 339138
The Uuniversity of Durham Mark 6 Gamma Ray Telescope
Armstrong, P.;
Chadwick, P. M.;
Cottle, P. J.;
Dickinson, J. E.;
Dickinson, M. R.;
Dipper, N. A.;
Hilton, S. E.;
Hogg, W.;
Holder, J.;
Kendall, T. R.;
McComb, T. J. L.;
Moore, C. M.;
Orford, K. J.;
Rayner, S. M.;
Roberts, I. D.;
Roberts, M. D.;
Robertshaw, M.;
Shaw, S. E.;
Tindale, K.;
Tummey, S. P.;
Turver, K. E.
Submitted: 1998-04-21
The design, construction and operation of the University of Durham
ground-based gamma ray telescope is discussed. The telescope has been designed
to detect gamma rays in the < 200 GeV region and to achieve good discrimination
between gamma ray and hadron initiated showers in the higher energy region (>
300 GeV). The telescope was commissioned in 1995 and a description of its
design and operation is presented, together with a verification of the
telescope's performance
[9]
oai:arXiv.org:astro-ph/9802338 [pdf] - 100509
Centaurus X-3 - A Source of High Energy Gamma Rays
Chadwick, P. M.;
Dickinson, M. R.;
Dipper, N. A.;
Kendall, T. R.;
McComb, T. J. L.;
Orford, K. J.;
Osborne, J. L.;
Rayner, S. M.;
Roberts, I. D.;
Shaw, S. E.;
Turver, K. E.
Submitted: 1998-02-26
Centaurus X-3 is a well-studied high-mass accreting X-ray binary and a
variable source of high energy gamma rays with energies from 100 MeV to 1 TeV.
Previous results have suggested that the origin of the gamma rays is not the
immediate vicinity of the neutron star but is sited in the accretion disc,
perhaps in an accretion wake. The Durham Mark 6 gamma ray telescope has been
used to measure the gamma ray flux from Centaurus X-3 with much higher
sensitivity than previous ground-based measurements. The flux above ~ 400 GeV
was measured to be (2 +/- 0.3) x 10^-11 cm^-2 s^-1 and appears constant over a
period of 2 - 3 months. In 10 hours of observations there is no evidence for
periodicity in the detected gamma rays at the X-ray spin period either from a
site in the region of the neutron star, or from any other potential site in the
orbit.