DiLuise, S.
Normalized to: DiLuise, S.
2 article(s) in total. 23 co-authors, from 1 to 2 common article(s). Median position in authors list is 6,0.
[1]
oai:arXiv.org:1612.06375 [pdf] - 1551971
The ArDM Liquid Argon Time Projection Chamber at the Canfranc
Underground Laboratory: a ton-scale detector for Dark Matter Searches
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Crivelli, P.;
Daniel, M.;
DiLuise, S.;
Gendotti, A.;
Horikawa, S.;
Montes, B.;
Mu, W.;
Murphy, S.;
Natterer, G.;
Ngyuen, K.;
Periale, L.;
Quan, Y.;
Radics, B.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Viant, T.;
Wu, S.
Submitted: 2016-12-19
The Argon Dark Matter (ArDM) experiment consists of a liquid argon (LAr) time
projection chamber (TPC) sensitive to nuclear recoils resulting from scattering
of hypothetical Weakly Interacting Massive Particles (WIMPs) on argon targets.
With an active target of 850 kg, ArDM represents an important milestone in the
quest for Dark Matter with LAr. We present the experimental apparatus currently
installed underground at the Laboratorio Subterraneo de Canfranc (LSC), Spain.
We show first data recorded during a single-phase commissioning run in 2015
(ArDM Run I), which overall confirm the good and stable performance of the
ton-scale LAr detector.
[2]
oai:arXiv.org:1611.02481 [pdf] - 1510448
Measurement of the attenuation length of argon scintillation light in
the ArDM LAr TPC
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Crivelli, P.;
Daniel, M.;
DiLuise, S.;
Gendotti, A.;
Horikawa, S.;
Molina-Bueno, L.;
Montes, B.;
Mu, W.;
Murphy, S.;
Natterer, G.;
Ngyuen, K.;
Periale, L.;
Quan, Y.;
Radics, B.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Viant, T.;
Wu, S.
Submitted: 2016-11-08
We report on a measurement of the attenuation length for the scintillation
light in the tonne size liquid argon target of the ArDM dark matter experiment.
The data was recorded in the first underground operation of the experiment in
single-phase operational mode. The results were achieved by comparing the light
yield spectra from 39-Ar and 83m-Kr to a description of the ArDM setup with a
model of full light ray tracing. A relatively low value close to 0.5 m was
found for the attenuation length of the liquid argon bulk to its own
scintillation light. We interpret this result as a presence of optically active
impurities in the liquid argon which are not filtered by the installed
purification systems. We also present analyses of the argon gas employed for
the filling and discuss cross sections in the vacuum ultraviolet of various
molecules in respect to purity requirements in the context of large liquid
argon installations.