sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Dillon, Daren

Normalized to: Dillon, D.

21 article(s) in total. 163 co-authors, from 1 to 16 common article(s). Median position in authors list is 10,0.

[1]  oai:arXiv.org:1907.07195  [pdf] - 1918436
FOBOS: A Next-Generation Spectroscopic Facility at the W. M. Keck Observatory
Comments: Submitted to the Astro2020 Decadal Survey as a facilities white paper
Submitted: 2019-07-16
High-multiplex and deep spectroscopic follow-up of upcoming panoramic deep-imaging surveys like LSST, Euclid, and WFIRST is a widely recognized and increasingly urgent necessity. No current or planned facility at a U.S. observatory meets the sensitivity, multiplex, and rapid-response time needed to exploit these future datasets. FOBOS, the Fiber-Optic Broadband Optical Spectrograph, is a near-term fiber-based facility that addresses these spectroscopic needs by optimizing depth over area and exploiting the aperture advantage of the existing 10m Keck II Telescope. The result is an instrument with a uniquely blue-sensitive wavelength range (0.31-1.0 um) at R~3500, high-multiplex (1800 fibers), and a factor 1.7 greater survey speed and order-of-magnitude greater sampling density than Subaru's Prime Focus Spectrograph (PFS). In the era of panoramic deep imaging, FOBOS will excel at building the deep, spectroscopic reference data sets needed to interpret vast imaging data. At the same time, its flexible focal plane, including a mode with 25 deployable integral-field units (IFUs) across a 20 arcmin diameter field, enables an expansive range of scientific investigations. Its key programmatic areas include (1) nested stellar-parameter training sets that enable studies of the Milky Way and M31 halo sub-structure, as well as local group dwarf galaxies, (2) a comprehensive picture of galaxy formation thanks to detailed mapping of the baryonic environment at z~2 and statistical linking of evolving populations to the present day, and (3) dramatic enhancements in cosmological constraints via precise photometric redshifts and determined redshift distributions. In combination with Keck I instrumentation, FOBOS also provides instant access to medium-resolution spectroscopy for transient sources with full coverage from the UV to the K-band.
[2]  oai:arXiv.org:1703.00011  [pdf] - 1557904
1 to 2.4 micron Near-IR spectrum of the Giant Planet $\beta$ Pictoris b obtained with the Gemini Planet Imager
Comments: 21 pages, 11 figures, Accepted to AJ
Submitted: 2017-02-28
Using the Gemini Planet Imager (GPI) located at Gemini South, we measured the near-infrared (1.0-2.4 micron) spectrum of the planetary companion to the nearby, young star $\beta$ Pictoris. We compare the spectrum obtained with currently published model grids and with known substellar objects and present the best matching models as well as the best matching observed objects. Comparing the empirical measurement of the bolometric luminosity to evolutionary models, we find a mass of $12.9\pm0.2$ $\mathcal{M}_\mathrm{Jup}$, an effective temperature of $1724\pm15$ K, a radius of $1.46\pm0.01$ $\mathcal{R}_\mathrm{Jup}$, and a surface gravity of $\log g = 4.18\pm0.01$ [dex] (cgs). The stated uncertainties are statistical errors only, and do not incorporate any uncertainty on the evolutionary models. Using atmospheric models, we find an effective temperature of $1700-1800$ K and a surface gravity of $\log g = 3.5$-$4.0$ [dex] depending upon model. These values agree well with other publications and with "hot-start" predictions from planetary evolution models. Further, we find that the spectrum of $\beta$ Pic b best matches a low-surface gravity L2$\pm$1 brown dwarf. Finally comparing the spectrum to field brown dwarfs we find the the spectrum best matches 2MASS J04062677-381210 and 2MASS J03552337+1133437.
[3]  oai:arXiv.org:1409.5456  [pdf] - 1217047
Gemini Planet Imager Spectroscopy of the HR 8799 planets c and d
Comments: Accepted for publication in ApJ
Submitted: 2014-09-18
During the first-light run of the Gemini Planet Imager (GPI) we obtained K-band spectra of exoplanets HR 8799 c and d. Analysis of the spectra indicates that planet d may be warmer than planet c. Comparisons to recent patchy cloud models and previously obtained observations over multiple wavelengths confirm that thick clouds combined with horizontal variation in the cloud cover generally reproduce the planets' spectral energy distributions. When combined with the 3 to 4 um photometric data points, the observations provide strong constraints on the atmospheric methane content for both planets. The data also provide further evidence that future modeling efforts must include cloud opacity, possibly including cloud holes, disequilibrium chemistry, and super-solar metallicity.
[4]  oai:arXiv.org:1407.8209  [pdf] - 1216029
Opto-Mechanical Design of ShaneAO: the Adaptive Optics System for the 3-meter Shane Telescope
Comments: 14 pages, 14 figures, 4 tables. Presented at SPIE Astronomical Telescopes + Instrumentation conference, paper 9148-119
Submitted: 2014-07-30
A Cassegrain mounted adaptive optics instrument presents unique challenges for opto-mechanical design. The flexure and temperature tolerances for stability are tighter than those of seeing limited instruments. This criteria requires particular attention to material properties and mounting techniques. This paper addresses the mechanical designs developed to meet the optical functional requirements. One of the key considerations was to have gravitational deformations, which vary with telescope orientation, stay within the optical error budget, or ensure that we can compensate with a steering mirror by maintaining predictable elastic behavior. Here we look at several cases where deformation is predicted with finite element analysis and Hertzian deformation analysis and also tested. Techniques used to address thermal deformation compensation without the use of low CTE materials will also be discussed.
[5]  oai:arXiv.org:1407.8205  [pdf] - 1216025
Commissioning ShARCS: the Shane Adaptive optics infraRed Camera-Spectrograph for the Lick Observatory 3-m telescope
Comments: 9 pages, 7 figures. Presented at SPIE Astronomical Telescopes + Instrumentation conference, paper 9148-118
Submitted: 2014-07-30
We describe the design and first-light early science performance of the Shane Adaptive optics infraRed Camera-Spectrograph (ShARCS) on Lick Observatory's 3-m Shane telescope. Designed to work with the new ShaneAO adaptive optics system, ShARCS is capable of high-efficiency, diffraction-limited imaging and low-dispersion grism spectroscopy in J, H, and K-bands. ShARCS uses a HAWAII-2RG infrared detector, giving high quantum efficiency (>80%) and Nyquist sampling the diffraction limit in all three wavelength bands. The ShARCS instrument is also equipped for linear polarimetry and is sensitive down to 650 nm to support future visible-light adaptive optics capability. We report on the early science data taken during commissioning.
[6]  oai:arXiv.org:1407.8206  [pdf] - 1216026
Swimming with ShARCS: Comparison of On-sky Sensitivity With Model Predictions for ShaneAO on the Lick Observatory 3-meter Telescope
Comments: 13 pages, 5 figures, SPIE Astronomical Telescopes + Instrumentation, Montreal 2014
Submitted: 2014-07-30
The Lick Observatory's Shane 3-meter telescope has been upgraded with a new infrared instrument (ShARCS - Shane Adaptive optics infraRed Camera and Spectrograph) and dual-deformable mirror adaptive optics (AO) system (ShaneAO). We present first-light measurements of imaging sensitivity in the Ks band. We compare measured results to predicted signal-to-noise ratio and magnitude limits from modeling the emissivity and throughput of ShaneAO and ShARCS. The model was validated by comparing its results to the Keck telescope adaptive optics system model and then by estimating the sky background and limiting magnitudes for IRCAL, the previous infra-red detector on the Shane telescope, and comparing to measured, published results. We predict that the ShaneAO system will measure lower sky backgrounds and achieve 20\% higher throughput across the $JHK$ bands despite having more optical surfaces than the current system. It will enable imaging of fainter objects (by 1-2 magnitudes) and will be faster to reach a fiducial signal-to-noise ratio by a factor of 10-13. We highlight the improvements in performance over the previous AO system and its camera, IRCAL.
[7]  oai:arXiv.org:1407.8207  [pdf] - 1216027
ShaneAO: wide science spectrum adaptive optics system for the Lick Observatory
Comments: 11 pages, 10 figures. Presented at SPIE Astronomical Telescopes + Instrumentation conference, paper 9148-76
Submitted: 2014-07-30
A new high-order adaptive optics system is now being commissioned at the Lick Observatory Shane 3-meter telescope in California. This system uses a high return efficiency sodium beacon and a combination of low and high-order deformable mirrors to achieve diffraction-limited imaging over a wide spectrum of infrared science wavelengths covering 0.8 to 2.2 microns. We present the design performance goals and the first on-sky test results. We discuss several innovations that make this system a pathfinder for next generation AO systems. These include a unique woofer-tweeter control that provides full dynamic range correction from tip/tilt to 16 cycles, variable pupil sampling wavefront sensor, new enhanced silver coatings developed at UC Observatories that improve science and LGS throughput, and tight mechanical rigidity that enables a multi-hour diffraction- limited exposure in LGS mode for faint object spectroscopy science.
[8]  oai:arXiv.org:1407.7895  [pdf] - 1215999
On-sky low order non-common path correction of the GPI Calibration Unit
Comments: 9 pages, 7 figures, Proc. SPIE 9148 (2014)
Submitted: 2014-07-29
The Gemini Planet Imager (GPI) entered on-sky commissioning phase, and had its First Light at the Gemini South telescope in November 2013. Meanwhile, the fast loops for atmospheric correction of the Extreme Adaptive Optics (XAO) system have been closed on many dozen stars at different magnitudes (I=4-8), elevation angles and a variety of seeing conditions, and a stable loop performance was achieved from the beginning. Ultimate contrast performance requires a very low residual wavefront error (design goal 60 nm RMS), and optimization of the planet finding instrument on different ends has just begun to deepen and widen its dark hole region. Laboratory raw contrast benchmarks are in the order of 10^-6 or smaller. In the telescope environment and in standard operations new challenges are faced (changing gravity, temperature, vibrations) that are tackled by a variety of techniques such as Kalman filtering, open-loop models to keep alignment to within 5 mas, speckle nulling, and a calibration unit (CAL). The CAL unit was especially designed by the Jet Propulsion Laboratory to control slowly varying wavefront errors at the focal plane of the apodized Lyot coronagraph by the means of two wavefront sensors: 1) a 7x7 low order Shack-Hartmann SH wavefront sensor (LOWFS), and 2) a special Mach-Zehnder interferometer for mid-order spatial frequencies (HOWFS) - atypical in that the beam is split in the focal plane via a pinhole but recombined in the pupil plane with a beamsplitter. The original design goal aimed for sensing and correcting on a level of a few nm which is extremely challenging in a telescope environment. This paper focuses on non-common path low order wavefront correction as achieved through the CAL unit on sky. We will present the obtained results as well as explain challenges that we are facing.
[9]  oai:arXiv.org:1407.7893  [pdf] - 1215998
On-sky vibration environment for the Gemini Planet Imager and mitigation effort
Comments: 12 pages,8 figures, Proc. SPIE 9148 (2014)
Submitted: 2014-07-29
The Gemini Planet Imager (GPI) entered on-sky commissioning and had its first-light at the Gemini South (GS) telescope in November 2013. GPI is an extreme adaptive optics (XAO), high-contrast imager and integral-field spectrograph dedicated to the direct detection of hot exo-planets down to a Jupiter mass. The performance of the apodized pupil Lyot coronagraph depends critically upon the residual wavefront error (design goal of 60 nm RMS with 5 mas RMS tip/tilt), and therefore is most sensitive to vibration (internal or external) of Gemini's instrument suite. Excess vibration can be mitigated by a variety of methods such as passive or active dampening at the instrument or telescope structure or Kalman filtering of specific frequencies with the AO control loop. Understanding the sources, magnitudes and impact of vibration is key to mitigation. This paper gives an overview of related investigations based on instrument data (GPI AO module) as well as external data from accelerometer sensors placed at different locations on the GS telescope structure. We report the status of related mitigation efforts, and present corresponding results.
[10]  oai:arXiv.org:1407.4469  [pdf] - 1451780
The First H-band Spectrum of the Massive Gas Giant Planet beta Pictoris b with the Gemini Planet Imager
Comments: 8 pages, 5 figures, submitted to ApJL
Submitted: 2014-07-16
Using the recently installed Gemini Planet Imager (GPI), we have taken the first H-band spectrum of the planetary companion to the nearby young star beta Pictoris. GPI is designed to image and provide low-resolution spectra of Jupiter sized, self-luminous planetary companions around young nearby stars. These observations were taken covering the H-band (1.65 microns). The spectrum has a resolving power of $\sim$ 45 and demonstrates the distinctive triangular shape of a cool substellar object with low surface gravity. Using atmospheric models, we find an effective temperature of $1650 \pm 50$ K and a surface gravity of $\log(g) = 4.0 \pm 0.25$ (cgs units). These values agree well with predictions from planetary evolution models for a gas giant with mass between 10 and 12 $M_{\rm Jup}$ and age between 10 and 20 Myrs.
[11]  oai:arXiv.org:1407.2495  [pdf] - 1215549
Polarimetry with the Gemini Planet Imager: Methods, Performance at First Light, and the Circumstellar Ring around HR 4796A
Comments: 27 pages, 16 figures, submitted to the Astrophysical Journal. A version with full resolution figures is available at http://www.stsci.edu/~mperrin/papers/gpi_polarimetry_and_HR_4796A.pdf
Submitted: 2014-07-09
We present the first results from the polarimetry mode of the Gemini Planet Imager (GPI), which uses a new integral field polarimetry architecture to provide high contrast linear polarimetry with minimal systematic biases between the orthogonal polarizations. We describe the design, data reduction methods, and performance of polarimetry with GPI. Point spread function subtraction via differential polarimetry suppresses unpolarized starlight by a factor of over 100, and provides sensitivity to circumstellar dust reaching the photon noise limit for these observations. In the case of the circumstellar disk around HR 4796A, GPI's advanced adaptive optics system reveals the disk clearly even prior to PSF subtraction. In polarized light, the disk is seen all the way in to its semi-minor axis for the first time. The disk exhibits surprisingly strong asymmetry in polarized intensity, with the west side >9 times brighter than the east side despite the fact that the east side is slightly brighter in total intensity. Based on a synthesis of the total and polarized intensities, we now believe that the west side is closer to us, contrary to most prior interpretations. Forward scattering by relatively large silicate dust particles leads to the strong polarized intensity on the west side, and the ring must be slightly optically thick in order to explain the lower brightness in total intensity there. These findings suggest that the ring is geometrically narrow and dynamically cold, perhaps shepherded by larger bodies in the same manner as Saturn's F ring.
[12]  oai:arXiv.org:1407.2314  [pdf] - 1215533
The Integral Field Spectrograph for the Gemini Planet Imager
Comments: 13 pages, 10 figures. Proceedings of the SPIE, 9147-55
Submitted: 2014-07-08
The Gemini Planet Imager (GPI) is a complex optical system designed to directly detect the self-emission of young planets within two arcseconds of their host stars. After suppressing the starlight with an advanced AO system and apodized coronagraph, the dominant residual contamination in the focal plane are speckles from the atmosphere and optical surfaces. Since speckles are diffractive in nature their positions in the field are strongly wavelength dependent, while an actual companion planet will remain at fixed separation. By comparing multiple images at different wavelengths taken simultaneously, we can freeze the speckle pattern and extract the planet light adding an order of magnitude of contrast. To achieve a bandpass of 20%, sufficient to perform speckle suppression, and to observe the entire two arcsecond field of view at diffraction limited sampling, we designed and built an integral field spectrograph with extremely low wavefront error and almost no chromatic aberration. The spectrograph is fully cryogenic and operates in the wavelength range 1 to 2.4 microns with five selectable filters. A prism is used to produce a spectral resolution of 45 in the primary detection band and maintain high throughput. Based on the OSIRIS spectrograph at Keck, we selected to use a lenslet-based spectrograph to achieve an rms wavefront error of approximately 25 nm. Over 36,000 spectra are taken simultaneously and reassembled into image cubes that have roughly 192x192 spatial elements and contain between 11 and 20 spectral channels. The primary dispersion prism can be replaced with a Wollaston prism for dual polarization measurements. The spectrograph also has a pupil-viewing mode for alignment and calibration.
[13]  oai:arXiv.org:1407.2305  [pdf] - 1215524
Gemini Planet Imager Observational Calibrations V: Astrometry and Distortion
Comments: 16 pages, 10 figures. Proceedings of the SPIE, 9147-306
Submitted: 2014-07-08
We present the results of both laboratory and on sky astrometric characterization of the Gemini Planet Imager (GPI). This characterization includes measurement of the pixel scale of the integral field spectrograph (IFS), the position of the detector with respect to north, and optical distortion. Two of these three quantities (pixel scale and distortion) were measured in the laboratory using two transparent grids of spots, one with a square pattern and the other with a random pattern. The pixel scale in the laboratory was also estimate using small movements of the artificial star unit (ASU) in the GPI adaptive optics system. On sky, the pixel scale and the north angle are determined using a number of known binary or multiple systems and Solar System objects, a subsample of which had concurrent measurements at Keck Observatory. Our current estimate of the GPI pixel scale is 14.14 $\pm$ 0.01 millarcseconds/pixel, and the north angle is -1.00 $\pm$ 0.03$\deg$. Distortion is shown to be small, with an average positional residual of 0.26 pixels over the field of view, and is corrected using a 5th order polynomial. We also present results from Monte Carlo simulations of the GPI Exoplanet Survey (GPIES) assuming GPI achieves ~1 milliarcsecond relative astrometric precision. We find that with this precision, we will be able to constrain the eccentricities of all detected planets, and possibly determine the underlying eccentricity distribution of widely separated Jovians.
[14]  oai:arXiv.org:1407.2278  [pdf] - 1215515
On-sky performance during verification and commissioning of the Gemini Planet Imager's adaptive optics system
Comments: Presented at SPIE 9148 on 23 June 2014. Submitted to Proceedings on 20 June 2014
Submitted: 2014-07-08
The Gemini Planet Imager instrument's adaptive optics (AO) subsystem was designed specifically to facilitate high-contrast imaging. It features several new technologies, including computationally efficient wavefront reconstruction with the Fourier transform, modal gain optimization every 8 seconds, and the spatially filtered wavefront sensor. It also uses a Linear-Quadratic-Gaussian (LQG) controller (aka Kalman filter) for both pointing and focus. We present on-sky performance results from verification and commissioning runs from December 2013 through May 2014. The efficient reconstruction and modal gain optimization are working as designed. The LQG controllers effectively notch out vibrations. The spatial filter can remove aliases, but we typically use it oversized by about 60% due to stability problems.
[15]  oai:arXiv.org:1407.2313  [pdf] - 1215532
Automated Alignment and On-Sky Performance of the Gemini Planet Imager Coronagraph
Comments: 11 pages, 7 figures. Proceedings of the SPIE, 9147-151
Submitted: 2014-07-08
The Gemini Planet Imager (GPI) is a next-generation, facility instrument currently being commissioned at the Gemini South observatory. GPI combines an extreme adaptive optics system and integral field spectrograph (IFS) with an apodized-pupil Lyot coronagraph (APLC) producing an unprecedented capability for directly imaging and spectroscopically characterizing extrasolar planets. GPI's operating goal of $10^{-7}$ contrast requires very precise alignments between the various elements of the coronagraph (two pupil masks and one focal plane mask) and active control of the beam path throughout the instrument. Here, we describe the techniques used to automatically align GPI and maintain the alignment throughout the course of science observations. We discuss the particular challenges of maintaining precision alignments on a Cassegrain mounted instrument and strategies that we have developed that allow GPI to achieve high contrast even in poor seeing conditions.
[16]  oai:arXiv.org:1403.7520  [pdf] - 1208686
The Gemini Planet Imager: First Light
Comments: 9 pages, 5 figures, accepted for publication Proc. Natl. Acad. Sci
Submitted: 2014-03-28
The Gemini Planet Imager (GPI) is a dedicated facility for directly imaging and spectroscopically characterizing extrasolar planets. It combines a very high-order adaptive optics system, a diffraction-suppressing coronagraph, and an integral field spectrograph with low spectral resolution but high spatial resolution. Every aspect of GPI has been tuned for maximum sensitivity to faint planets near bright stars. During first light observations, we achieved an estimated H band Strehl ratio of 0.89 and a 5-sigma contrast of $10^6$ at 0.75 arcseconds and $10^5$ at 0.35 arcseconds. Observations of Beta Pictoris clearly detect the planet, Beta Pictoris b, in a single 60-second exposure with minimal post-processing. Beta Pictoris b is observed at a separation of $434 \pm 6$ milli-arcseconds and position angle $211.8 \pm 0.5$ deg. Fitting the Keplerian orbit of Beta Pic b using the new position together with previous astrometry gives a factor of three improvement in most parameters over previous solutions. The planet orbits at a semi-major axis of $9.0^{+0.8}_{-0.4}$ AU near the 3:2 resonance with the previously-known 6 AU asteroidal belt and is aligned with the inner warped disk. The observations give a 4% posterior probability of a transit of the planet in late 2017.
[17]  oai:arXiv.org:1311.4423  [pdf] - 1180792
Final A&T Stages of the Gemini Planet Finder
Comments: 10 pages, 6 figures, submitted to Proceedings of AO4ELT3 conference, Florence, Italy, May 2013
Submitted: 2013-11-18
The Gemini Planet Imager (GPI) is currently in its final Acceptance & Testing stages. GPI is an XAO system based on a tweeter & woofer architecture (43 & 9 actuators respectively across the pupil), with the tweeter being a Boston Michromachines $64^2$ MEMS device. The XAO AO system is tightly integrated with a Lyot apodizing coronagraph. Acceptance testing started in February 2013 at the University of California, Santa Cruz. A conclusive acceptance review was held in July 2013 and the instrument was found ready for shipment to the Gemini South telescope on Cerro Pachon, Chile. Commissioning at the telescope will take place by the end of 2013, matching the summer window of the southern hemisphere. According to current estimates the 3 year planet finding campaign (890 allocated hours) might discover, image, and spectroscopically analyze 20 to 40 new exo-planets. Final acceptance testing of the integrated instrument can always bring up surprises when using cold chamber and flexure rig installations. The latest developments are reported. Also, we will give an overview of GPI's lab performance, the interplay between subsystems such as the calibration unit (CAL) with the AO bench. We report on-going optimizations on the AO controller loop to filter vibrations and last but not least achieved contrast performance applying speckle nulling. Furthermore, we will give an outlook of possible but challenging future upgrades as the implementation of a predictive controller or exchanging the conventional 48x48 SH WFS with a pyramid. With the ELT era arising, GPI will proof as a versatile and path-finding testbed for AO technologies on the next generation of ground-based telescopes.
[18]  oai:arXiv.org:1209.4711  [pdf] - 1151552
Production of Phase Screens for Simulation of Atmospheric Turbulence
Comments:
Submitted: 2012-09-21
The ability to simulate atmospheric turbulence in the lab is a crucial part of testing and developing astronomical adaptive optics technology. We report on the development of a technique for creating phase plates, which involves the strategic application of clear acrylic paint onto a transparent substrate. Results of interferometric characterization of these plates is described and compared to Kolmogorov statistics. The range of r0 (Fried's parameter) achieved thus far is 0.2 - 1.2 mm, with a Kolmogorov power law. These phase plates have been successfully used by the lab for Adaptive Optics at University of California, Santa Cruz, in the Multi-Conjugate Adaptive Optics testbed, as part of the Villages (Visible Light Laser Guidestar Experiments) calibration system, and during integration and testing of the Gemini Planet Imager. This method has proven to be an effective and low cost means to simulate turbulence. We are now distributing the plates to other members of the AO community.
[19]  oai:arXiv.org:1202.1566  [pdf] - 1116461
MEMS practice, from the lab to the telescope
Comments: 14 pages, 15 figures, Invited Paper, SPIE Photonics West 2012
Submitted: 2012-02-07
Micro-electro-mechanical systems (MEMS) technology can provide for deformable mirrors (DMs) with excellent performance within a favorable economy of scale. Large MEMS-based astronomical adaptive optics (AO) systems such as the Gemini Planet Imager are coming on-line soon. As MEMS DM end-users, we discuss our decade of practice with the micromirrors, from inspecting and characterizing devices to evaluating their performance in the lab. We also show MEMS wavefront correction on-sky with the "Villages" AO system on a 1-m telescope, including open-loop control and visible-light imaging. Our work demonstrates the maturity of MEMS technology for astronomical adaptive optics.
[20]  oai:arXiv.org:1007.2691  [pdf] - 1033716
Performance of MEMS-based visible-light adaptive optics at Lick Observatory: Closed- and open-loop control
Comments: 16 pages, 13 figures, to appear in Proc. SPIE 2010 Vol. 7736 Adaptive Optics Systems II, high-resolution full-color version available at http://spiedl.org/
Submitted: 2010-07-15
At the University of California's Lick Observatory, we have implemented an on-sky testbed for next-generation adaptive optics (AO) technologies. The Visible-Light Laser Guidestar Experiments instrument (ViLLaGEs) includes visible-light AO, a micro-electro-mechanical-systems (MEMS) deformable mirror, and open-loop control of said MEMS on the 1-meter Nickel telescope at Mt. Hamilton. In this paper we evaluate the performance of ViLLaGEs in open- and closed-loop control, finding that both control methods give equivalent Strehl ratios of up to ~ 7% in I-band and similar rejection of temporal power. Therefore, we find that open-loop control of MEMS on-sky is as effective as closed-loop control. Furthermore, after operating the system for three years, we find MEMS technology to function well in the observatory environment. We construct an error budget for the system, accounting for 130 nm of wavefront error out of 190 nm error in the science-camera PSFs. We find that the dominant known term is internal static error, and that the known contributions to the error budget from open-loop control (MEMS model, position repeatability, hysteresis, and WFS linearity) are negligible.
[21]  oai:arXiv.org:0903.5355  [pdf] - 250709
Stroke saturation on a MEMS deformable mirror for woofer-tweeter adaptive optics
Comments: 16 pages, 10 figures
Submitted: 2009-03-30
High-contrast imaging of extrasolar planet candidates around a main-sequence star has recently been realized from the ground using current adaptive optics (AO) systems. Advancing such observations will be a task for the Gemini Planet Imager, an upcoming "extreme" AO instrument. High-order "tweeter" and low-order "woofer" deformable mirrors (DMs) will supply a >90%-Strehl correction, a specialized coronagraph will suppress the stellar flux, and any planets can then be imaged in the "dark hole" region. Residual wavefront error scatters light into the DM-controlled dark hole, making planets difficult to image above the noise. It is crucial in this regard that the high-density tweeter, a micro-electrical mechanical systems (MEMS) DM, have sufficient stroke to deform to the shapes required by atmospheric turbulence. Laboratory experiments were conducted to determine the rate and circumstance of saturation, i.e. stroke insufficiency. A 1024-actuator 1.5-um-stroke MEMS device was empirically tested with software Kolmogorov-turbulence screens of r_0=10-15cm. The MEMS when solitary suffered saturation ~4% of the time. Simulating a woofer DM with ~5-10 actuators across a 5-m primary mitigated MEMS saturation occurrence to a fraction of a percent. While no adjacent actuators were saturated at opposing positions, mid-to-high-spatial-frequency stroke did saturate more frequently than expected, implying that correlations through the influence functions are important. Analytical models underpredict the stroke requirements, so empirical studies are important.