Normalized to: Didier, J.
[1]
oai:arXiv.org:1908.07495 [pdf] - 1945993
PICO: Probe of Inflation and Cosmic Origins
Hanany, S.;
Alvarez, M.;
Artis, E.;
Ashton, P.;
Aumont, J.;
Aurlien, R.;
Banerji, R.;
Barreiro, R. B.;
Bartlett, J. G.;
Basak, S.;
Battaglia, N.;
Bock, J.;
Boddy, K. K.;
Bonato, M.;
Borrill, J.;
Bouchet, F.;
Boulanger, F.;
Burkhart, B.;
Chluba, J.;
Chuss, D.;
Clark, S.;
Cooperrider, J.;
Crill, B. P.;
De Zotti, G.;
Delabrouille, J.;
Di Valentino, E.;
Didier, J.;
Dore, O.;
Eriksen, H. K.;
Errard, J.;
Essinger-Hileman, T.;
Feeney, S.;
Filippini, J.;
Fissel, L.;
Flauger, R.;
Fuskeland, U.;
Gluscevic, V.;
Gorski, K. M.;
Green, D.;
Hensley, B.;
Herranz, D.;
Hill, J. C.;
Hivon, E.;
Hlozek, R.;
Hubmayr, J.;
Johnson, B. R.;
Jones, W.;
Jones, T.;
Knox, L.;
Kogut, A.;
Lopez-Caniego, M.;
Lawrence, C.;
Lazarian, A.;
Li, Z.;
Madhavacheril, M.;
Melin, J. B.;
Meyers, J.;
Murray, C.;
Negrello, M.;
Novak, G.;
O'Brient, R.;
Paine, C.;
Pearson, T.;
Pogosian, L.;
Pryke, C.;
Puglisi, G.;
Remazeilles, M.;
Rocha, G.;
Schmittfull, M.;
Scott, D.;
Shirron, P.;
Stephens, I.;
Sutin, B.;
Tomasi, M.;
Trangsrud, A.;
van Engelen, A.;
Vansyngel, F.;
Wehus, I. K.;
Wen, Q.;
Xu, S.;
Young, K.;
Zonca, A.
Submitted: 2019-08-20
The Probe of Inflation and Cosmic Origins (PICO) is a proposed probe-scale
space mission consisting of an imaging polarimeter operating in frequency bands
between 20 and 800 GHz. We describe the science achievable by PICO, which has
sensitivity equivalent to more than 3300 Planck missions, the technical
implementation, the schedule and cost.
[2]
oai:arXiv.org:1902.10541 [pdf] - 1842579
PICO: Probe of Inflation and Cosmic Origins
Hanany, Shaul;
Alvarez, Marcelo;
Artis, Emmanuel;
Ashton, Peter;
Aumont, Jonathan;
Aurlien, Ragnhild;
Banerji, Ranajoy;
Barreiro, R. Belen;
Bartlett, James G.;
Basak, Soumen;
Battaglia, Nick;
Bock, Jamie;
Boddy, Kimberly K.;
Bonato, Matteo;
Borrill, Julian;
Bouchet, François;
Boulanger, François;
Burkhart, Blakesley;
Chluba, Jens;
Chuss, David;
Clark, Susan E.;
Cooperrider, Joelle;
Crill, Brendan P.;
De Zotti, Gianfranco;
Delabrouille, Jacques;
Di Valentino, Eleonora;
Didier, Joy;
Doré, Olivier;
Eriksen, Hans K.;
Errard, Josquin;
Essinger-Hileman, Tom;
Feeney, Stephen;
Filippini, Jeffrey;
Fissel, Laura;
Flauger, Raphael;
Fuskeland, Unni;
Gluscevic, Vera;
Gorski, Krzysztof M.;
Green, Dan;
Hensley, Brandon;
Herranz, Diego;
Hill, J. Colin;
Hivon, Eric;
Hložek, Renée;
Hubmayr, Johannes;
Johnson, Bradley R.;
Jones, William;
Jones, Terry;
Knox, Lloyd;
Kogut, Al;
López-Caniego, Marcos;
Lawrence, Charles;
Lazarian, Alex;
Li, Zack;
Madhavacheril, Mathew;
Melin, Jean-Baptiste;
Meyers, Joel;
Murray, Calum;
Negrello, Mattia;
Novak, Giles;
O'Brient, Roger;
Paine, Christopher;
Pearson, Tim;
Pogosian, Levon;
Pryke, Clem;
Puglisi, Giuseppe;
Remazeilles, Mathieu;
Rocha, Graca;
Schmittfull, Marcel;
Scott, Douglas;
Shirron, Peter;
Stephens, Ian;
Sutin, Brian;
Tomasi, Maurizio;
Trangsrud, Amy;
van Engelen, Alexander;
Vansyngel, Flavien;
Wehus, Ingunn K.;
Wen, Qi;
Xu, Siyao;
Young, Karl;
Zonca, Andrea
Submitted: 2019-02-26, last modified: 2019-03-05
The Probe of Inflation and Cosmic Origins (PICO) is an imaging polarimeter
that will scan the sky for 5 years in 21 frequency bands spread between 21 and
799 GHz. It will produce full-sky surveys of intensity and polarization with a
final combined-map noise level of 0.87 $\mu$K arcmin for the required
specifications, equivalent to 3300 Planck missions, and with our current
best-estimate would have a noise level of 0.61 $\mu$K arcmin (6400 Planck
missions). PICO will either determine the energy scale of inflation by
detecting the tensor to scalar ratio at a level $r=5\times 10^{-4}~(5\sigma)$,
or will rule out with more than $5\sigma$ all inflation models for which the
characteristic scale in the potential is the Planck scale. With LSST's data it
could rule out all models of slow-roll inflation. PICO will detect the sum of
neutrino masses at $>4\sigma$, constrain the effective number of light particle
species with $\Delta N_{\rm eff}<0.06~(2\sigma)$, and elucidate processes
affecting the evolution of cosmic structures by measuring the optical depth to
reionization with errors limited by cosmic variance and by constraining the
evolution of the amplitude of linear fluctuations $\sigma_{8}(z)$ with
sub-percent accuracy. Cross-correlating PICO's map of the thermal
Sunyaev-Zeldovich effect with LSST's gold sample of galaxies will precisely
trace the evolution of thermal pressure with $z$. PICO's maps of the Milky Way
will be used to determine the make up of galactic dust and the role of magnetic
fields in star formation efficiency. With 21 full sky legacy maps in intensity
and polarization, which cannot be obtained in any other way, the mission will
enrich many areas of astrophysics. PICO is the only single-platform instrument
with the combination of sensitivity, angular resolution, frequency bands, and
control of systematic effects that can deliver this compelling, timely, and
broad science.
[3]
oai:arXiv.org:1808.07445 [pdf] - 1841339
The Simons Observatory: Science goals and forecasts
The Simons Observatory Collaboration;
Ade, Peter;
Aguirre, James;
Ahmed, Zeeshan;
Aiola, Simone;
Ali, Aamir;
Alonso, David;
Alvarez, Marcelo A.;
Arnold, Kam;
Ashton, Peter;
Austermann, Jason;
Awan, Humna;
Baccigalupi, Carlo;
Baildon, Taylor;
Barron, Darcy;
Battaglia, Nick;
Battye, Richard;
Baxter, Eric;
Bazarko, Andrew;
Beall, James A.;
Bean, Rachel;
Beck, Dominic;
Beckman, Shawn;
Beringue, Benjamin;
Bianchini, Federico;
Boada, Steven;
Boettger, David;
Bond, J. Richard;
Borrill, Julian;
Brown, Michael L.;
Bruno, Sarah Marie;
Bryan, Sean;
Calabrese, Erminia;
Calafut, Victoria;
Calisse, Paolo;
Carron, Julien;
Challinor, Anthony;
Chesmore, Grace;
Chinone, Yuji;
Chluba, Jens;
Cho, Hsiao-Mei Sherry;
Choi, Steve;
Coppi, Gabriele;
Cothard, Nicholas F.;
Coughlin, Kevin;
Crichton, Devin;
Crowley, Kevin D.;
Crowley, Kevin T.;
Cukierman, Ari;
D'Ewart, John M.;
Dünner, Rolando;
de Haan, Tijmen;
Devlin, Mark;
Dicker, Simon;
Didier, Joy;
Dobbs, Matt;
Dober, Bradley;
Duell, Cody J.;
Duff, Shannon;
Duivenvoorden, Adri;
Dunkley, Jo;
Dusatko, John;
Errard, Josquin;
Fabbian, Giulio;
Feeney, Stephen;
Ferraro, Simone;
Fluxà, Pedro;
Freese, Katherine;
Frisch, Josef C.;
Frolov, Andrei;
Fuller, George;
Fuzia, Brittany;
Galitzki, Nicholas;
Gallardo, Patricio A.;
Ghersi, Jose Tomas Galvez;
Gao, Jiansong;
Gawiser, Eric;
Gerbino, Martina;
Gluscevic, Vera;
Goeckner-Wald, Neil;
Golec, Joseph;
Gordon, Sam;
Gralla, Megan;
Green, Daniel;
Grigorian, Arpi;
Groh, John;
Groppi, Chris;
Guan, Yilun;
Gudmundsson, Jon E.;
Han, Dongwon;
Hargrave, Peter;
Hasegawa, Masaya;
Hasselfield, Matthew;
Hattori, Makoto;
Haynes, Victor;
Hazumi, Masashi;
He, Yizhou;
Healy, Erin;
Henderson, Shawn W.;
Hervias-Caimapo, Carlos;
Hill, Charles A.;
Hill, J. Colin;
Hilton, Gene;
Hilton, Matt;
Hincks, Adam D.;
Hinshaw, Gary;
Hložek, Renée;
Ho, Shirley;
Ho, Shuay-Pwu Patty;
Howe, Logan;
Huang, Zhiqi;
Hubmayr, Johannes;
Huffenberger, Kevin;
Hughes, John P.;
Ijjas, Anna;
Ikape, Margaret;
Irwin, Kent;
Jaffe, Andrew H.;
Jain, Bhuvnesh;
Jeong, Oliver;
Kaneko, Daisuke;
Karpel, Ethan D.;
Katayama, Nobuhiko;
Keating, Brian;
Kernasovskiy, Sarah S.;
Keskitalo, Reijo;
Kisner, Theodore;
Kiuchi, Kenji;
Klein, Jeff;
Knowles, Kenda;
Koopman, Brian;
Kosowsky, Arthur;
Krachmalnicoff, Nicoletta;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Kusaka, Akito;
Lashner, Jacob;
Lee, Adrian;
Lee, Eunseong;
Leon, David;
Leung, Jason S. -Y.;
Lewis, Antony;
Li, Yaqiong;
Li, Zack;
Limon, Michele;
Linder, Eric;
Lopez-Caraballo, Carlos;
Louis, Thibaut;
Lowry, Lindsay;
Lungu, Marius;
Madhavacheril, Mathew;
Mak, Daisy;
Maldonado, Felipe;
Mani, Hamdi;
Mates, Ben;
Matsuda, Frederick;
Maurin, Loïc;
Mauskopf, Phil;
May, Andrew;
McCallum, Nialh;
McKenney, Chris;
McMahon, Jeff;
Meerburg, P. Daniel;
Meyers, Joel;
Miller, Amber;
Mirmelstein, Mark;
Moodley, Kavilan;
Munchmeyer, Moritz;
Munson, Charles;
Naess, Sigurd;
Nati, Federico;
Navaroli, Martin;
Newburgh, Laura;
Nguyen, Ho Nam;
Niemack, Michael;
Nishino, Haruki;
Orlowski-Scherer, John;
Page, Lyman;
Partridge, Bruce;
Peloton, Julien;
Perrotta, Francesca;
Piccirillo, Lucio;
Pisano, Giampaolo;
Poletti, Davide;
Puddu, Roberto;
Puglisi, Giuseppe;
Raum, Chris;
Reichardt, Christian L.;
Remazeilles, Mathieu;
Rephaeli, Yoel;
Riechers, Dominik;
Rojas, Felipe;
Roy, Anirban;
Sadeh, Sharon;
Sakurai, Yuki;
Salatino, Maria;
Rao, Mayuri Sathyanarayana;
Schaan, Emmanuel;
Schmittfull, Marcel;
Sehgal, Neelima;
Seibert, Joseph;
Seljak, Uros;
Sherwin, Blake;
Shimon, Meir;
Sierra, Carlos;
Sievers, Jonathan;
Sikhosana, Precious;
Silva-Feaver, Maximiliano;
Simon, Sara M.;
Sinclair, Adrian;
Siritanasak, Praween;
Smith, Kendrick;
Smith, Stephen R.;
Spergel, David;
Staggs, Suzanne T.;
Stein, George;
Stevens, Jason R.;
Stompor, Radek;
Suzuki, Aritoki;
Tajima, Osamu;
Takakura, Satoru;
Teply, Grant;
Thomas, Daniel B.;
Thorne, Ben;
Thornton, Robert;
Trac, Hy;
Tsai, Calvin;
Tucker, Carole;
Ullom, Joel;
Vagnozzi, Sunny;
van Engelen, Alexander;
Van Lanen, Jeff;
Van Winkle, Daniel D.;
Vavagiakis, Eve M.;
Vergès, Clara;
Vissers, Michael;
Wagoner, Kasey;
Walker, Samantha;
Ward, Jon;
Westbrook, Ben;
Whitehorn, Nathan;
Williams, Jason;
Williams, Joel;
Wollack, Edward J.;
Xu, Zhilei;
Yu, Byeonghee;
Yu, Cyndia;
Zago, Fernando;
Zhang, Hezi;
Zhu, Ningfeng
Submitted: 2018-08-22, last modified: 2019-03-01
The Simons Observatory (SO) is a new cosmic microwave background experiment
being built on Cerro Toco in Chile, due to begin observations in the early
2020s. We describe the scientific goals of the experiment, motivate the design,
and forecast its performance. SO will measure the temperature and polarization
anisotropy of the cosmic microwave background in six frequency bands: 27, 39,
93, 145, 225 and 280 GHz. The initial configuration of SO will have three
small-aperture 0.5-m telescopes (SATs) and one large-aperture 6-m telescope
(LAT), with a total of 60,000 cryogenic bolometers. Our key science goals are
to characterize the primordial perturbations, measure the number of
relativistic species and the mass of neutrinos, test for deviations from a
cosmological constant, improve our understanding of galaxy evolution, and
constrain the duration of reionization. The SATs will target the largest
angular scales observable from Chile, mapping ~10% of the sky to a white noise
level of 2 $\mu$K-arcmin in combined 93 and 145 GHz bands, to measure the
primordial tensor-to-scalar ratio, $r$, at a target level of $\sigma(r)=0.003$.
The LAT will map ~40% of the sky at arcminute angular resolution to an expected
white noise level of 6 $\mu$K-arcmin in combined 93 and 145 GHz bands,
overlapping with the majority of the LSST sky region and partially with DESI.
With up to an order of magnitude lower polarization noise than maps from the
Planck satellite, the high-resolution sky maps will constrain cosmological
parameters derived from the damping tail, gravitational lensing of the
microwave background, the primordial bispectrum, and the thermal and kinematic
Sunyaev-Zel'dovich effects, and will aid in delensing the large-angle
polarization signal to measure the tensor-to-scalar ratio. The survey will also
provide a legacy catalog of 16,000 galaxy clusters and more than 20,000
extragalactic sources.
[4]
oai:arXiv.org:1808.08597 [pdf] - 1739200
Design and Characterization of a Balloon-Borne Diffraction-Limited
Submillimeter Telescope Platform for BLAST-TNG
Lourie, Nathan P.;
Angile, Francisco E.;
Ashton, Peter C.;
Catanzaro, Brian;
Devlin, Mark J.;
Dicker, Simon;
Didier, Joy;
Dober, Bradley;
Fissel, Laura M.;
Galitzki, Nicholas;
Gordon, Samuel;
Klein, Jeffrey;
Lowe, Ian;
Mauskopf, Philip;
Nati, Federico;
Novak, Giles;
Romualdez, L. Javier;
Soler, Juan D.;
Williams, Paul A.
Submitted: 2018-08-26
The Next Generation Balloon-borne Large Aperture Submillimeter Telescope
(BLAST-TNG) is a submillimeter mapping experiment planned for a 28 day
long-duration balloon (LDB) flight from McMurdo Station, Antarctica during the
2018-2019 season. BLAST-TNG will detect submillimeter polarized interstellar
dust emission, tracing magnetic fields in galactic molecular clouds. BLAST-TNG
will be the first polarimeter with the sensitivity and resolution to probe the
$\sim$0.1 parsec-scale features that are critical to understanding the origin
of structures in the interstellar medium. With three detector arrays operating
at 250, 350, and 500 $\mu$m (1200, 857, and 600 GHz), BLAST-TNG will obtain
diffraction-limited resolution at each waveband of 30, 41, and 59 arcseconds
respectively.
To achieve the submillimeter resolution necessary for its science goals, the
BLAST-TNG telescope features a 2.5 m aperture carbon fiber composite primary
mirror, one of the largest mirrors flown on a balloon platform. Successful
performance of such a large telescope on a balloon-borne platform requires
stiff, lightweight optical components and mounting structures. Through a
combination of optical metrology and finite element modeling of thermal and
mechanical stresses on both the telescope optics and mounting structures, we
expect diffraction-limited resolution at all our wavebands. We expect pointing
errors due to deformation of the telescope mount to be negligible. We have
developed a detailed thermal model of the sun shielding, gondola, and optical
components to optimize our observing strategy and increase the stability of the
telescope over the flight. We present preflight characterization of the
telescope and its platform.
[5]
oai:arXiv.org:1808.07442 [pdf] - 1737618
Studies of Systematic Uncertainties for Simons Observatory: Polarization
Modulator Related Effects
Salatino, Maria;
Lashner, Jacob;
Gerbino, Martina;
Simon, Sara M.;
Didier, Joy;
Ali, Aamir;
Ashton, Peter C.;
Bryan, Sean;
Chinone, Yuji;
Coughlin, Kevin;
Crowley, Kevin T.;
Fabbian, Giulio;
Galitzki, Nicholas;
Goeckner-Wald, Neil;
Golec, Joseph E.;
Gudmundsson, Jon E.;
Hill, Charles A.;
Keating, Brian;
Kusaka, Akito;
Lee, Adrian T.;
McMahon, Jeffrey;
Miller, Amber D.;
Puglisi, Giuseppe;
Reichardt, Christian L.;
Teply, Grant;
Xu, Zhilei;
Zhu, Ningfeng
Submitted: 2018-08-22
The Simons Observatory (SO) will observe the temperature and polarization
anisotropies of the cosmic microwave background (CMB) over a wide range of
frequencies (27 to 270 GHz) and angular scales by using both small (0.5 m) and
large (6 m) aperture telescopes. The SO small aperture telescopes will target
degree angular scales where the primordial B-mode polarization signal is
expected to peak. The incoming polarization signal of the small aperture
telescopes will be modulated by a cryogenic, continuously-rotating half-wave
plate (CRHWP) to mitigate systematic effects arising from slowly varying noise
and detector pair-differencing. In this paper, we present an assessment of some
systematic effects arising from using a CRHWP in the SO small aperture systems.
We focus on systematic effects associated with structural properties of the HWP
and effects arising when operating a HWP, including the amplitude of the HWP
synchronous signal (HWPSS), and I -> P (intensity to polarization) leakage that
arises from detector non-linearity in the presence of a large HWPSS. We
demonstrate our ability to simulate the impact of the aforementioned systematic
effects in the time domain. This important step will inform mitigation
strategies and design decisions to ensure that SO will meet its science goals.
[6]
oai:arXiv.org:1803.01018 [pdf] - 1783724
The EBEX Balloon Borne Experiment - Detectors and Readout
The EBEX Collaboration;
Abitbol, Maximilian;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Feeney, Stephen M.;
Geach, Christopher;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Johannes;
Irwin, Kent;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Miller, Amber D.;
Milligan, Michael;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Tucker, Gregory S.;
Westbrook, Benjamin;
Young, Karl;
Zilic, Kyle
Submitted: 2018-03-02, last modified: 2018-07-30
EBEX was a long-duration balloon-borne experiment to measure the polarization
of the cosmic microwave background. The experiment had three frequency bands
centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array
of transition edge sensor (TES) bolometers aboard a balloon platform; shortly
after reaching float we operated 504, 342, and 109 TESs at each of the bands,
respectively. We describe the design and characterization of the array and the
readout system. We give the distributions of measured thermal conductances,
normal resistances, and transition temperatures. With the exception of the
thermal conductance at 150 GHz. We measured median low-loop-gain time constants
$\tau_{0}=$ 88, 46, and 57 ms and compare them to predictions. Two measurements
of bolometer absorption efficiency show high ($\sim$0.9) efficiency at 150 GHz
and medium ($\sim$0.35, and $\sim$0.25) at the two higher bands, respectively.
We measure a median total optical load of 3.6, 5.3 and 5.0 pW absorbed at the
three bands, respectively. EBEX pioneered the use of the digital version of the
frequency domain multiplexing (FDM) system which multiplexed the bias and
readout of 16 bolometers onto two wires. We present accounting of the measured
noise equivalent power. The median per-detector noise equivalent temperatures
referred to a black body with a temperature of 2.725 K are 400, 920, and 14500
$\mu$K$\sqrt{s}$ for the three bands, respectively. We compare these values to
our pre-flight predictions and to a previous balloon payload, discuss the
sources of excess noise, and the path for a future payload to make full use of
the balloon environment.
[7]
oai:arXiv.org:1711.01314 [pdf] - 1877825
Intensity-Coupled-Polarization in Instruments with a Continuously
Rotating Half-Wave Plate
Didier, Joy;
Miller, Amber D.;
Araujo, Derek;
Aubin, François;
Geach, Christopher;
Johnson, Bradley;
Korotkov, Andrei;
Raach, Kate;
Westbrook, Benjamin;
Young, Karl;
Aboobaker, Asad M.;
Ade, Peter;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Jones, Terry;
Klein, Jeff;
Lee, Adrian;
Limon, Michele;
MacDermid, Kevin;
Milligan, Michael;
Pascale, Enzo;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Carole;
Tucker, Gregory S.;
Zilic, Kyle
Submitted: 2017-11-03, last modified: 2018-02-28
We discuss a systematic effect associated with measuring polarization with a
continuously rotating half-wave plate. The effect was identified with the data
from the E and B Experiment (EBEX), which was a balloon-borne instrument
designed to measure the polarization of the CMB as well as that from Galactic
dust. The data show polarization fraction larger than 10\% while less than 3\%
were expected from instrumental polarization. We give evidence that the excess
polarization is due to detector non-linearity in the presence of a continuously
rotating HWP. The non-linearity couples intensity signals into polarization. We
develop a map-based method to remove the excess polarization. Applying this
method for the 150 (250) GHz bands data we find that 81\% (92\%) of the excess
polarization was removed. Characterization and mitigation of this effect is
important for future experiments aiming to measure the CMB B-modes with a
continuously rotating HWP.
[8]
oai:arXiv.org:1703.03847 [pdf] - 1783689
The EBEX Balloon Borne Experiment - Optics, Receiver, and Polarimetry
The EBEX Collaboration;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Geach, Christopher;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Miller, Amber D.;
Milligan, Michael;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Savini, Giorgio;
Spencer, Locke;
Tucker, Carole;
Tucker, Gregory S.;
Westbrook, Ben;
Young, Karl;
Zilic, Kyle
Submitted: 2017-03-10, last modified: 2017-05-30
The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic
microwave background polarimeter that flew over Antarctica in 2013. We describe
the experiment's optical system, receiver, and polarimetric approach, and
report on their in-flight performance. EBEX had three frequency bands centered
on 150, 250, and 410 GHz. To make efficient use of limited mass and space we
designed a 115 cm$^{2}$sr high throughput optical system that had two ambient
temperature mirrors and four anti-reflection coated polyethylene lenses per
focal plane. All frequency bands shared the same optical train. Polarimetry was
achieved with a continuously rotating achromatic half-wave plate (AHWP) that
was levitated with a superconducting magnetic bearing (SMB). Rotation stability
was 0.45 % over a period of 10 hours, and angular position accuracy was 0.01
degrees. This is the first use of a SMB in astrophysics. The measured
modulation efficiency was above 90 % for all bands. To our knowledge the 109 %
fractional bandwidth of the AHWP was the broadest implemented to date. The
receiver that contained one lens and the AHWP at a temperature of 4 K, the
polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K
performed according to specifications giving focal plane temperature stability
with fluctuation power spectrum that had $1/f$ knee at 2 mHz. EBEX was the
first balloon-borne instrument to implement technologies characteristic of
modern CMB polarimeters including high throughput optical systems, and large
arrays of transition edge sensor bolometric detectors with mutiplexed readouts.
[9]
oai:arXiv.org:1702.01817 [pdf] - 1581403
Torsional Balloon Flight Line Oscillations: Comparison of Modelling to
Flight Data
Submitted: 2017-02-06, last modified: 2017-05-03
During the EBEX2013 long duration flight the payload was free to rotate in
azimuth. The observed azimuth motion consisted of a superposition of full
rotations with a period of 10-30 minutes and oscillatory motion with an
amplitude of tens of degrees, average period of 79 s, and period dispersion of
12 s. We interpret the full rotations as induced by slow rotations of the
balloon and the shorter period oscillatory motion as due to torsional
oscillations of the flight line. We derive the torsional stiffness of the
flight line using the bifilar pendulum model and apply it to the flight line of
the EBEX2013 payload. We find a torsional spring constant of 36 kg m$^2$/s$^2$
corresponding to a period of 58 s. We conclude that the bifilar model, which
accounts for the geometry of the flight line but neglects all material
properties, predicts a stiffness and period that are 45% larger and 25% shorter
than those observed. It is useful to have a simple, easy to use, coarse
approximation for the torsional constant of the flight line.
[10]
oai:arXiv.org:1702.07020 [pdf] - 1783687
The EBEX Balloon-Borne Experiment - Gondola, Attitude Control, and
Control Software
The EBEX Collaboration;
Aboobaker, Asad;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Miller, Amber D.;
Milligan, Michael;
Moncelsi, Lorenzo;
Pascale, Enzo;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Carole;
Tucker, Gregory S.;
Westbrook, Benjamin;
Young, Karl;
Zilic, Kyle
Submitted: 2017-02-22, last modified: 2017-04-11
The E and B Experiment (EBEX) was a long-duration balloon-borne instrument
designed to measure the polarization of the cosmic microwave background (CMB)
radiation. EBEX was the first balloon-borne instrument to implement a
kilo-pixel array of transition edge sensor (TES) bolometric detectors and the
first CMB experiment to use the digital version of the frequency domain
multiplexing system for readout of the TES array. The scan strategy relied on
40 s peak-to-peak constant velocity azimuthal scans. We discuss the unique
demands on the design and operation of the payload that resulted from these new
technologies and the scan strategy. We describe the solutions implemented
including the development of a power system designed to provide a total of at
least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors'
readout system, software to manage and handle the data of the kilo-pixel array,
and specialized attitude reconstruction software. We present flight performance
data showing faultless management of the TES array, adequate powering and
cooling of the readout electronics, and constraint of attitude reconstruction
errors such that the spurious B-modes they induced were less than 10% of CMB
B-mode power spectrum with $r=0.05$.
[11]
oai:arXiv.org:1602.03249 [pdf] - 1356056
A high-resolution pointing system for fast scanning platforms: The EBEX
example
Didier, Joy;
Chapman, Daniel;
Aboobaker, Asad;
Araujo, Derek;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Korotkov, Andrei;
Limon, Michele;
Miller, Amber;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Greg;
Vinokurov, Yuri
Submitted: 2016-02-09
The E and B experiment (EBEX) is a balloon-borne telescope designed to
measure the polarization of the cosmic microwave background with 8' resolution
employing a gondola scanning with speeds of order degree per second. In January
2013, EBEX completed 11 days of observations in a flight over Antarctica
covering $\sim$ 6000 square degrees of the sky. The payload is equipped with
two redundant star cameras and two sets of three orthogonal gyroscopes to
reconstruct the telescope attitude. The EBEX science goals require the pointing
to be reconstructed to approximately 10" in the map domain, and in-flight
attitude control requires the real time pointing to be accurate to $\sim$
0.5$^{\circ}$ . The high velocity scan strategy of EBEX coupled to its float
altitude only permits the star cameras to take images at scan turnarounds,
every $\sim$ 40 seconds, and thus requires the development of a pointing system
with low noise gyroscopes and carefully controlled systematic errors. Here we
report on the design of the pointing system and on a simulation pipeline
developed to understand and minimize the effects of systematic errors. The
performance of the system is evaluated using the 2012/2013 flight data, and we
show that we achieve a pointing error with RMS=25" on 40 seconds azimuth
throws, corresponding to an error of $\sim$ 4.6" in the map domain.
[12]
oai:arXiv.org:1601.07923 [pdf] - 1350058
Temperature calibration of the E and B experiment
Aubin, Francois;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Feeney, Stephen;
Geach, Christopher;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
Macdermid, Kevin;
Marchenko, Valerie;
Miller, Amber D.;
Milligan, Michael;
Pascale, Enzo;
Puglisi, Giuseppe;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Stompor, Radek;
Tristram, Matthieu;
Tucker, Gregory S.;
Westbrook, Ben;
Young, Karl;
Zilic, Kyle
Submitted: 2016-01-28
The E and B Experiment (EBEX) is a balloon-borne polarimeter designed to
measure the polarization of the cosmic microwave background radiation and to
characterize the polarization of galactic dust. EBEX was launched December 29,
2012 and circumnavigated Antarctica observing $\sim$6,000 square degrees of sky
during 11 days at three frequency bands centered around 150, 250 and 410 GHz.
EBEX was the first experiment to operate a kilo-pixel array of transition-edge
sensor bolometers and a continuously rotating achromatic half-wave plate aboard
a balloon platform. It also pioneered the use of detector readout based on
digital frequency domain multiplexing.
We describe the temperature calibration of the experiment. The gain response
of the experiment is calibrated using a two-step iterative process. We use
signals measured on passes across the Galactic plane to convert from
readout-system counts to power. The effective smoothing scale of the EBEX
optics and the star camera-to-detector offset angles are determined through
\c{hi}2 minimization using the compact HII region RCW 38. This two-step process
is initially performed with parameters measured before the EBEX 2013 flight and
then repeated until the calibration factor and parameters converge.
[13]
oai:arXiv.org:1510.01983 [pdf] - 1289916
Stratospheric Imaging of Polar Mesospheric Clouds: A New Window on
Small-Scale Atmospheric Dynamics
Miller, A. D.;
Fritts, D. C.;
Chapman, D.;
Jones, G.;
Limon, M.;
Araujo, D.;
Didier, J.;
Hillbrand, S.;
Kjellstrand, C. B.;
Korotkov, A.;
Tucker, G.;
Vinokurov, Y.;
Wan, K.;
Wang, L.
Submitted: 2015-10-07
Instabilities and turbulence extending to the smallest dynamical scales play
important roles in the deposition of energy and momentum by gravity waves
throughout the atmosphere. However, these dynamics and their effects have been
impossible to quantify to date due to lack of observational guidance.
Serendipitous optical images of polar mesospheric clouds at ~82 km obtained by
star cameras aboard a cosmology experiment deployed on a stratospheric balloon
provide a new observational tool, revealing instability and turbulence
structures extending to spatial scales < 20 m. At 82 km, this resolution
provides sensitivity extending to the smallest turbulence scale not strongly
influenced by viscosity: the "inner scale" of turbulence,
$l_0\sim$10($\nu^3$/$\epsilon$)$^{1/4}$. Such images represent a new window
into small-scale dynamics that occur throughout the atmosphere but are
impossible to observe in such detail at any other altitude. We present a sample
of images revealing a range of dynamics features, and employ numerical
simulations that resolve these dynamics to guide our interpretation of several
observed events.
[14]
oai:arXiv.org:1410.4892 [pdf] - 1222641
STARS: A software application for the EBEX autonomous daytime star
cameras
Submitted: 2014-10-17
The E and B Experiment (EBEX) is a balloon-borne telescope designed to probe
polarization signals in the CMB resulting from primordial gravitational waves,
gravitational lensing, and Galactic dust emission. EBEX completed an 11 day
flight over Antarctica in January 2013 and data analysis is underway. EBEX
employs two star cameras to achieve its real-time and post-flight pointing
requirements. We wrote a software application called STARS to operate, command,
and collect data from each of the star cameras, and to interface them with the
main flight computer. We paid special attention to make the software robust
against potential in-flight failures. We report on the implementation, testing,
and successful in flight performance of STARS.
[15]
oai:arXiv.org:1407.6249 [pdf] - 880220
A LEKID-based CMB instrument design for large-scale observations in
Greenland
Araujo, D. C.;
Ade, P. A. R.;
Bond, J. R.;
Bradford, K. J.;
Chapman, D.;
Che, G.;
Day, P. K.;
Didier, J.;
Doyle, S.;
Eriksen, H. K.;
Flanigan, D.;
Groppi, C. E.;
Hillbrand, S. N.;
Johnson, B. R.;
Jones, G.;
Limon, M.;
Miller, A. D.;
Mauskopf, P.;
McCarrick, H.;
Mroczkowski, T.;
Reichborn-Kjennerud, B.;
Smiley, B.;
Sobrin, J.;
Wehus, I. K.;
Zmuidzinas, J.
Submitted: 2014-07-10, last modified: 2014-10-10
We present the results of a feasibility study, which examined deployment of a
ground-based millimeter-wave polarimeter, tailored for observing the cosmic
microwave background (CMB), to Isi Station in Greenland. The instrument for
this study is based on lumped-element kinetic inductance detectors (LEKIDs) and
an F/2.4 catoptric, crossed-Dragone telescope with a 500 mm aperture. The
telescope is mounted inside the receiver and cooled to $<\,4$ K by a
closed-cycle $^4$He refrigerator to reduce background loading on the detectors.
Linearly polarized signals from the sky are modulated with a metal-mesh
half-wave plate that is rotated at the aperture stop of the telescope with a
hollow-shaft motor based on a superconducting magnetic bearing. The modular
detector array design includes at least 2300 LEKIDs, and it can be configured
for spectral bands centered on 150~GHz or greater. Our study considered
configurations for observing in spectral bands centered on 150, 210 and
267~GHz. The entire polarimeter is mounted on a commercial precision rotary air
bearing, which allows fast azimuth scan speeds with negligible vibration and
mechanical wear over time. A slip ring provides power to the instrument,
enabling circular scans (360 degrees of continuous rotation). This mount, when
combined with sky rotation and the latitude of the observation site, produces a
hypotrochoid scan pattern, which yields excellent cross-linking and enables
34\% of the sky to be observed using a range of constant elevation scans. This
scan pattern and sky coverage combined with the beam size (15~arcmin at
150~GHz) makes the instrument sensitive to $5 < \ell < 1000$ in the angular
power spectra.
[16]
oai:arXiv.org:1407.6894 [pdf] - 1215912
The performance of the bolometer array and readout system during the
2012/2013 flight of the E and B experiment (EBEX)
MacDermid, Kevin;
Aboobaker, Asad M.;
Ade, Peter;
Aubin, Francois;
Baccigalupi, Carlo;
Bandura, Kevin;
Bao, Chaoyun;
Borrill, Julian;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grain, Julien;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Hannes;
Irwin, Kent;
Johnson, Bradley;
Jaffe, Andrew;
Jones, Terry;
Kisner, Ted;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
Miller, Amber;
Milligan, Michael;
Pascale, Enzo;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Stompor, Radek;
Tristram, Matthieu;
Tucker, Greg;
Westbrook, Ben;
Zilic, Kyle
Submitted: 2014-07-22
EBEX is a balloon-borne telescope designed to measure the polarization of the
cosmic microwave background radiation. During its eleven day science flight in
the Austral Summer of 2012, it operated 955 spider-web transition edge sensor
(TES) bolometers separated into bands at 150, 250 and 410 GHz. This is the
first time that an array of TES bolometers has been used on a balloon platform
to conduct science observations. Polarization sensitivity was provided by a
wire grid and continuously rotating half-wave plate. The balloon implementation
of the bolometer array and readout electronics presented unique development
requirements. Here we present an outline of the readout system, the remote
tuning of the bolometers and Superconducting QUantum Interference Device
(SQUID) amplifiers, and preliminary current noise of the bolometer array and
readout system.
[17]
oai:arXiv.org:1308.0235 [pdf] - 857218
The Detector System for the Stratospheric Kinetic Inductance Polarimeter
(SKIP)
Johnson, B. R.;
Ade, P. A. R.;
Araujo, D.;
Bradford, K. J.;
Chapman, D.;
Day, P. K.;
Didier, J.;
Doyle, S.;
Eriksen, H. K.;
Flanigan, D.;
Groppi, C.;
Hillbrand, S.;
Jones, G.;
Limon, M.;
Mauskopf, P.;
McCarrick, H.;
Miller, A.;
Mroczkowski, T.;
Reichborn-Kjennerud, B.;
Smiley, B.;
Sobrin, J.;
Wehus, I. K.;
Zmuidzinas, J.
Submitted: 2013-08-01, last modified: 2014-01-05
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed
balloon-borne experiment designed to study the cosmic microwave background, the
cosmic infrared background and Galactic dust emission by observing 1133 square
degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden.
The instrument contains 2317 single-polarization, horn-coupled, aluminum
lumped-element kinetic inductance detectors (LEKID). The LEKIDs will be
maintained at 100 mK with an adiabatic demagnetization refrigerator. The
polarimeter operates in two configurations, one sensitive to a spectral band
centered on 150 GHz and the other sensitive to 260 and 350 GHz bands. The
detector readout system is based on the ROACH-1 board, and the detectors will
be biased below 300 MHz. The detector array is fed by an F/2.4 crossed-Dragone
telescope with a 500 mm aperture yielding a 15 arcmin FWHM beam at 150 GHz. To
minimize detector loading and maximize sensitivity, the entire optical system
will be cooled to 1 K. Linearly polarized sky signals will be modulated with a
metal-mesh half-wave plate that is mounted at the telescope aperture and
rotated by a superconducting magnetic bearing. The observation program consists
of at least two, five-day flights beginning with the 150 GHz observations.
[18]
oai:arXiv.org:1112.3057 [pdf] - 488565
The Impact of the Spectral Response of an Achromatic Half-Wave Plate on
the Measurement of the Cosmic Microwave Background Polarization
Bao, C.;
Gold, B.;
Baccigalupi, C.;
Didier, J.;
Hanany, S.;
Jaffe, A.;
Johnson, B. R.;
Leach, S.;
Matsumura, T.;
Miller, A.;
O'Dea, D.
Submitted: 2011-12-13
We study the impact of the spectral dependence of the linear polarization
rotation induced by an achromatic half-wave plate on measurements of cosmic
microwave background polarization in the presence of astrophysical foregrounds.
We focus on the systematic effects induced on the measurement of inflationary
gravitational waves by uncertainties in the polarization and spectral index of
Galactic dust. We find that for the experimental configuration and noise levels
of the balloon-borne EBEX experiment, which has three frequency bands centered
at 150, 250, and 410 GHz, a crude dust subtraction process mitigates systematic
effects to below detectable levels for 10% polarized dust and tensor to scalar
ratio of as low as r = 0.01. We also study the impact of uncertainties in the
spectral response of the instrument. With a top-hat model of the spectral
response for each band, characterized by band-center and band-width, and with
the same crude dust subtraction process, we find that these parameters need to
be determined to within 1 and 0.8 GHz at 150 GHz; 9 and 2.0 GHz at 250 GHz; and
20 and 14 GHz at 410 GHz, respectively. The approach presented in this paper is
applicable to other optical elements that exhibit polarization rotation as a
function of frequency.
[19]
oai:arXiv.org:1007.3672 [pdf] - 1033814
EBEX: A balloon-borne CMB polarization experiment
Reichborn-Kjennerud, Britt;
Aboobaker, Asad M.;
Ade, Peter;
Aubin, Françcois;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Cantalupo, Christopher;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grain, Julien;
Grainger, William;
Hanany, Shaul;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Leach, Sam;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Meng, Xiaofan;
Miller, Amber;
Milligan, Michael;
Pascale, Enzo;
Polsgrove, Daniel;
Ponthieu, Nicolas;
Raach, Kate;
Sagiv, Ilan;
Smecher, Graeme;
Stivoli, Federico;
Stompor, Radek;
Tran, Huan;
Tristram, Matthieu;
Tucker, Gregory S.;
Vinokurov, Yury;
Yadav, Amit;
Zaldarriaga, Matias;
Zilic, Kyle
Submitted: 2010-07-21
EBEX is a NASA-funded balloon-borne experiment designed to measure the
polarization of the cosmic microwave background (CMB). Observations will be
made using 1432 transition edge sensor (TES) bolometric detectors read out with
frequency multiplexed SQuIDs. EBEX will observe in three frequency bands
centered at 150, 250, and 410 GHz, with 768, 384, and 280 detectors in each
band, respectively. This broad frequency coverage is designed to provide
valuable information about polarized foreground signals from dust. The
polarized sky signals will be modulated with an achromatic half wave plate
(AHWP) rotating on a superconducting magnetic bearing (SMB) and analyzed with a
fixed wire grid polarizer. EBEX will observe a patch covering ~1% of the sky
with 8' resolution, allowing for observation of the angular power spectrum from
\ell = 20 to 1000. This will allow EBEX to search for both the primordial
B-mode signal predicted by inflation and the anticipated lensing B-mode signal.
Calculations to predict EBEX constraints on r using expected noise levels show
that, for a likelihood centered around zero and with negligible foregrounds,
99% of the area falls below r = 0.035. This value increases by a factor of 1.6
after a process of foreground subtraction. This estimate does not include
systematic uncertainties. An engineering flight was launched in June, 2009,
from Ft. Sumner, NM, and the long duration science flight in Antarctica is
planned for 2011. These proceedings describe the EBEX instrument and the North
American engineering flight.
[20]
oai:arXiv.org:1006.5256 [pdf] - 229058
Software systems for operation, control, and monitoring of the EBEX
instrument
Milligan, Michael;
Ade, Peter;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Cantalupo, Christopher;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Leach, Sam;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Miller, Amber;
Pascale, Enzo;
Polsgrove, Daniel;
Ponthieu, Nicolas;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tran, Huan;
Tucker, Gregory S.;
Vinokurov, Yury;
Yadav, Amit;
Zaldarriaga, Matias;
Zilic, Kyle
Submitted: 2010-06-27, last modified: 2010-07-05
We present the hardware and software systems implementing autonomous
operation, distributed real-time monitoring, and control for the EBEX
instrument. EBEX is a NASA-funded balloon-borne microwave polarimeter designed
for a 14 day Antarctic flight that circumnavigates the pole. To meet its
science goals the EBEX instrument autonomously executes several tasks in
parallel: it collects attitude data and maintains pointing control in order to
adhere to an observing schedule; tunes and operates up to 1920 TES bolometers
and 120 SQUID amplifiers controlled by as many as 30 embedded computers;
coordinates and dispatches jobs across an onboard computer network to manage
this detector readout system; logs over 3~GiB/hour of science and housekeeping
data to an onboard disk storage array; responds to a variety of commands and
exogenous events; and downlinks multiple heterogeneous data streams
representing a selected subset of the total logged data. Most of the systems
implementing these functions have been tested during a recent engineering
flight of the payload, and have proven to meet the target requirements. The
EBEX ground segment couples uplink and downlink hardware to a client-server
software stack, enabling real-time monitoring and command responsibility to be
distributed across the public internet or other standard computer networks.
Using the emerging dirfile standard as a uniform intermediate data format, a
variety of front end programs provide access to different components and views
of the downlinked data products. This distributed architecture was demonstrated
operating across multiple widely dispersed sites prior to and during the EBEX
engineering flight.
[21]
oai:arXiv.org:1005.3339 [pdf] - 168465
The EBEX Cryostat and Supporting Electronics
Sagiv, Ilan;
Aboobaker, Asad M.;
Bao, Chaoyun;
Hanany, Shaul;
Jones, Terry;
Klein, Jeffrey;
Milligan, Michael;
Polsgrove, Daniel E.;
Raach, Kate;
Zilic, Kyle;
Korotkov, Andrei;
Tucker, Gregory S.;
Vinukurov, Yuri;
Matsumura, Tomotake;
Ade, Peter;
Grainger, Will;
Pascale, Enzo;
Chapman, Daniel;
Didier, Joy;
Hillbrand, Seth;
Reichborn-Kjennerud, Britt;
Limon, Michele;
Miller, Amber;
Jaffe, Andrew;
Yadav, Amit;
Zaldarriaga, Matias;
Ponthieu, Nicolas;
Tristram, Matthieu;
Borrill, Julian;
Cantalupo, Christopher;
Kisner, Ted;
Aubin, Francois;
Dobbs, Matt;
MacDermid, Kevin;
Hilton, Gene;
Hubmayr, Johhannes;
Irwin, Kent;
Reintsema, Carl;
Baccigalupi, Carlo;
Leach, Sam;
Johnson, Bradley;
Lee, Adrian;
Tran, Huan;
Levinson, Lorne
Submitted: 2010-05-18
We describe the cryostat and supporting electronics for the EBEX experiment.
EBEX is a balloon-borne polarimeter designed to measure the B-mode polarization
of the cosmic microwave background radiation. The instrument includes a 1.5
meter Gregorian-type telescope and 1432 bolometric transition edge sensor
detectors operating at 0.3 K. Electronics for monitoring temperatures and
controlling cryostat refrigerators is read out over CANbus. A timing system
ensures the data from all subsystems is accurately synchronized. EBEX completed
an engineering test flight in June 2009 during which the cryogenics and
supporting electronics performed according to predictions. The temperatures of
the cryostat were stable, and an analysis of a subset of the data finds no scan
synchronous signal in the cryostat temperatures. Preparations are underway for
an Antarctic flight.