Di Luise, S.
Normalized to: Di Luise, S.
3 article(s) in total. 33 co-authors, from 1 to 3 common article(s). Median position in authors list is 6,0.
[1]
oai:arXiv.org:1712.07971 [pdf] - 1678506
Impact of the positive ion current on large size neutrino detectors and
delayed photon emission
Submitted: 2017-12-21
Given their small mobility coefficient in liquid argon with respect to the
electrons, the ions spend a considerably longer time in the active volume. We
studied the effects of the positive ion current in a liquid argon time
projection chamber, in the context of massive argon experiments for neutrino
physics. The constant recombination between free ions and electrons produces a
quenching of the charge signal and a constant emission of photons, uncorrelated
in time and space to the physical interactions. The predictions evidence some
potential concerns for multi-ton argon detectors, particularly when operated on
surface
[2]
oai:arXiv.org:1712.01932 [pdf] - 1799803
Backgrounds and pulse shape discrimination in the ArDM liquid argon TPC
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Crivelli, P.;
Daniel, M.;
Di Luise, S.;
Gendotti, A.;
Horikawa, S.;
Molina-Bueno, L.;
Montes, B.;
Mu, W.;
Murphy, S.;
Natterer, G.;
Nguyen, K.;
Periale, L.;
Quan, Y.;
Radics, B.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Viant, T.;
Wu, S.
Submitted: 2017-12-02
The ArDM experiment completed a single-phase commissioning run in 2015 with
an active liquid argon target of nearly one tonne in mass. The analysis of the
data and comparison to simulations allowed for a test of the crucial detector
properties and confirmed the low background performance of the setup. The
statistical rejection power for electron recoil events using the pulse shape
discrimination method was estimated using data from a Cf-252 neutron
calibration source. Electron and nuclear recoil band profiles were found to be
well described by Gaussian distributions. Employing such a model we derive
values for the electron recoil statistical rejection power of more than 10$^8$
in the tonne-scale liquid argon target for events with more than 50 detected
photons at a 50% acceptance for nuclear recoils. The Rn-222 emanation rate of
the ArDM cryostat at room temperature was found to be 65.6$\pm$0.4 $\mu$Hz/l,
and the Ar-39 specific activity from the employed atmospheric argon to be
0.95$\pm$0.05 Bq/kg. The cosmic muon flux at the Canfranc underground site was
determined to be between 2 and 3.5$\times 10^{-3}m^{2}s^{-1}$ . These results
pave the way for the next physics run of ArDM in the double-phase operational
mode.
[3]
oai:arXiv.org:1505.02443 [pdf] - 996764
Status of ArDM-1t: First observations from operation with a full
ton-scale liquid argon target
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Daniel, M.;
Degunda, U.;
Di Luise, S.;
Epprecht, L.;
Gendotti, A.;
Horikawa, S.;
Knecht, L.;
Montes, B.;
Mu, W.;
Munoz, M.;
Murphy, S.;
Natterer, G.;
Nguyen, K.;
Nikolics, K.;
Periale, L.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Sgalaberna, D.;
Viant, T.;
Wu, S.
Submitted: 2015-05-10
ArDM-1t is the first operating ton-scale liquid argon detector for direct
search of Dark Matter particles. Developed at CERN as Recognized Experiment
RE18, the experiment has been approved in 2010 to be installed in the Spanish
underground site LSC (Laboratorio Subterraneo de Canfranc). Under the label of
LSC EXP-08-2010 the ArDM detector underwent an intensive period of technical
completion and safety approval until the recent filling of the target vessel
with almost 2 ton of liquid argon. This report describes the experimental
achievements during commissioning of ArDM and the transition into a stage of
first physics data taking in single phase operational mode. We present
preliminary observations from this run. A first indication for the background
discrimination power of LAr detectors at the ton-scale is shown. We present an
outlook for completing the detector with the electric drift field and upgrade
of the scintillation light readout system with novel detector modules based on
SiPMs in order to improve the light yield.