Normalized to: Devasia, J.
[1]
oai:arXiv.org:1106.3251 [pdf] - 1077344
Timing and spectral studies of the transient X-ray pulsar GX 304-1
during an outburst
Submitted: 2011-06-16
We present the timing and spectral properties of the transient X-ray pulsar
GX 304-1 during its recent outburst in 2010 August, using observations carried
out with the Proportional Counter Array (PCA) instrument on-board the Rossi
X-ray Timing Explorer (RXTE) satellite. We detected strong intensity and energy
dependent variations in the pulse profiles during the outburst. The pulse
profile showed significant evolution over the outburst. It showed complex
structures consisting of a main peak with steps on both sides during the start
of the outburst. On some days, a sharp dip like feature was seen which
disappeared at the end of the outburst; when the profile evolved into a
sinusoidal shape. At low energies, the pulse profiles appeared complex,
consisting of multiple peaks and a narrow minimum. The amplitude of the second
brightest peak in low energies decreased with energy, and above 12 keV, the
shape of the pulse profile changed to a single broad peak with a dip like
feature. The dip had energy dependence, both in phase and in width. We detected
Quasi-periodic Oscillations (QPO) at 0.125 Hz with a harmonic. The QPO feature
had a low rms value of 2.9% and it showed a positive energy dependence up to 40
keV with the rms value increasing to 9% at 40 keV. The QPO frequency decreased
from 0.128 Hz to 0.108 Hz in 12 days. During most of the outburst, the 3-30 keV
spectrum of GX 304-1 can be well fitted with a partial covering power-law model
with a high energy cut-off and iron fluorescent line emission. For a few of the
observations carried out during the decay of the outburst, the partial covering
absorption component is found to change to single component absorption. We also
found that the partial covering and high energy cut-off parameters vary
significantly with the pulse phase.
[2]
oai:arXiv.org:1101.5020 [pdf] - 1051699
RXTE-PCA observations of 1A 1118--61: timing and spectral studies during
an outburst
Submitted: 2011-01-26
We report detailed timing and spectral analysis of RXTE-PCA data obtained
from observations during the outburst of a transient X-ray pulsar 1A 1118--61
in January 2009. The pulse profile showed significant evolution during the
outburst and also significant energy dependence - a double peaked profile upto
10 keV and a single peak at higher energy. We have also detected quasi-periodic
oscillations (QPO) at 0.07--0.09 Hz. The rms value of the QPO is 5.2% and it
shows a significant energy dependence with highest rms of 7% at 9 keV. The QPO
frequency changed from 0.09 Hz to 0.07 Hz within 10 days. The magnetic field
strength calculated using the QPO frequency and the X-ray luminosity is in
agreement with the magnetic field strength measured from the energy of the
cyclotron absorption feature detected in this source. The 3-30 keV energy
spectrum over the 2009 outburst of 1A 1118--61 can be well fitted with a
partial covering power-law model with a high energy cutoff and an iron
fluorescence line emission. The pulse phase resolved spectral analysis shows
that the partial covering and high energy cutoff model parameters have
significant changes with the pulse phase.
[3]
oai:arXiv.org:1009.0846 [pdf] - 223644
Development of a Thomson X-ray Polarimeter
Submitted: 2010-09-04
We describe the current status of the design and development of a Thomson
X-ray polarimeter suitable for a small satellite mission. Currently we are
considering two detector geometries, one using rectangular detectors placed on
four sides of a scattering element and the other using a single cylindrical
detector with the scattering element at the center. The rectangular detector
configuration has been fabricated and tested. The cylindrical detector is
currently under fabrication. In order to compensate any pointing offset of the
satellite, a collimator with a flat topped response has been developed that
provides a constant effective area over an angular range. We have also
developed a double crystal monochromator/polariser for the purpose of test and
calibration of the polarimeter. Preliminary test results from the developmental
activities are presented here.
[4]
oai:arXiv.org:1008.2815 [pdf] - 1034324
Flares, Broadening of the Pulse frequency peak, and Quasi Periodic
Oscillations in the Transient X-ray Pulsar 4U 1901+03
Submitted: 2010-08-17
After a long quiescence of three decades, the transient X-ray pulsar 4U
1901+03 became highly active in 2003 February. From the analysis of a large
number of Rossi X-ray Timing Explorer/ Proportional Counter Array (RXTE/PCA)
observations of this source, we report here the detection of X-ray flares, a
broadening of the pulse frequency peak and Quasi Periodic Oscillations (QPOs).
The X-ray flares showed spectral changes, had a duration of 100 s - 300 s, and
were more frequent and stronger during the peak of the outburst. In most of the
observations during the outburst we also detected a broadening of the pulse
frequency peak. We have also found intensity dependent changes in the pulse
profile at very short timescales. This reveals a coupling between the periodic
and the low frequency aperiodic variabilities. In addition, near the end of the
outburst we have detected a strong QPO feature centered at ~ 0.135 Hz. The QPO
feature is broad with a quality factor of 3.3 and with an rms value of
18.5+/-3.1%. Using the QPO frequency and the X-ray luminosity during the QPO
detection period we estimated the magnetic field strength of the neutron star
as 0.31*10^12 G which is consistent with the value inferred earlier under the
assumption of spin equilibrium.
[5]
oai:arXiv.org:1006.1035 [pdf] - 296807
Variations in the X-ray eclipse transitions of Cen X-3
Submitted: 2010-06-05
We report here an investigation of the X-ray eclipse transitions of the high
mass X-ray binary pulsar Cen X-3 in different intensity states. Long term light
curve of Cen X-3 obtained with RXTE-ASM spanning for more than 5000 days shows
strong aperiodic flux variations with low and high states. We have investigated
the eclipse transitions of Cen X-3 in different intensity states with data
obtained from pointed observations with the more sensitive instruments on board
ASCA, BeppoSAX, XMM-Newton, Chandra and RXTE. We found a very clear trend of
sharp eclipse transitions in the high state and longer transitions in the low
state. This is a confirmation of this feature first observed with the RXTE-ASM
but now with much better clarity. From the light curves obtained from several
missions, it is seen that the eclipse egress in the low state starts earlier by
an orbital phase of 0.02 indicating that the observed X-rays originate from a
much larger region. We have also performed spectral analysis of the
post-eclipse part of each observations. From BeppoSAX observations, the
out-of-eclipse X-ray fluxes is found to differ by a factor of ~ 26 during the
high and low intensity states while the eclipse count rates differ by a factor
of only ~ 4.7. This indicates that in the low state, there is an additional
scattering medium which scatters some of the source photons towards the
observer even when the neutron star is completely eclipsed. We could also
resolve the three iron line components using XMM-Newton observation in the low
state. By comparing the iron line equivalent width during the high and low
states, it is seen that the width of iron line is relatively large during the
low state which supports the fact that significant reprocessing and scattering
of X-rays takes place in the low state.
[6]
oai:arXiv.org:1005.1161 [pdf] - 1026716
Discovery of a 0.02 Hz QPO feature in the Transient X-ray Pulsar KS
1947+300
Submitted: 2010-05-07
We report the discovery of Quasi Periodic Oscillations (QPO) at 0.02 Hz in a
transient high mass X-ray binary pulsar KS 1947+300 using {\em RXTE}-PCA. The
QPOs were detected during May-June 2001, at the end of a long outburst. This is
the 9th transient accretion powered high magnetic field X-ray pulsar in which
QPOs have been detected and the QPO frequency of this source is lowest in this
class of sources. The unusual feature of this source is that though the
outburst lasted for more than 100 days, the QPOs were detected only during the
last few days of the outburst when the X-ray intensity had decayed to 1.6% of
the peak intensity. The rms value of the QPO is large, $\sim15.4\pm1.0%$ with a
slight positive correlation with energy. The detection of QPOs and strong
pulsations at a low luminosity level suggests that the magnetic field strength
of the neutron star is not as high as was predicted earlier on the basis of a
correlation between the spin-up torque and the X-ray luminosity.