Normalized to: Dering, K.
[1]
oai:arXiv.org:1902.04048 [pdf] - 1924972
Search for dark matter with a 231-day exposure of liquid argon using
DEAP-3600 at SNOLAB
Ajaj, R.;
Amaudruz, P. -A.;
Araujo, G. R.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bonatt, J.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Cavuoti, S.;
Chen, M.;
Chen, Y.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Doria, L.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Fiorillo, G.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Gallacher, D.;
Garcés, E. A.;
Garg, S.;
Giampa, P.;
Goeldi, D.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Joy, A.;
Jillings, C. J.;
Kamaev, O.;
Kaur, G.;
Kemp, A.;
Kochanek, I.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Li, X.;
Lidgard, J.;
Lindner, T.;
Litvinov, O.;
Lock, J.;
Longo, G.;
Majewski, P.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Piro, M. -C.;
Pollmann, T. R.;
Rand, E. T.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Viel, S.;
Walding, J.;
Waqar, M.;
Ward, M.;
Westerdale, S.;
Willis, J.;
Zuñiga-Reyes, A.
Submitted: 2019-02-11, last modified: 2019-07-04
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter
experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The
detector consists of 3279 kg of LAr contained in a spherical acrylic vessel.
This paper reports on the analysis of a 758 tonne\cdot day exposure taken over
a period of 231 live-days during the first year of operation. No candidate
signal events are observed in the WIMP-search region of interest, which results
in the leading limit on the WIMP-nucleon spin-independent cross section on a
LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a
100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a
detailed background model, this analysis demonstrates the best pulse-shape
discrimination in LAr at threshold, employs a Bayesian photoelectron-counting
technique to improve the energy resolution and discrimination efficiency, and
utilizes two position reconstruction algorithms based on PMT charge and photon
arrival times.
[2]
oai:arXiv.org:1905.05811 [pdf] - 1994027
Electromagnetic Backgrounds and Potassium-42 Activity in the DEAP-3600
Dark Matter Detector
Ajaj, R.;
Araujo, G. R.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cárdenas-Montes, M.;
Cavuoti, S.;
Chen, M.;
Chen, Y.;
Cleveland, B. T.;
Dering, K.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Fiorillo, G.;
Flower, A.;
Ford, R. J.;
Gallacher, D.;
Abia, P. García;
Garg, S.;
Giampa, P.;
Goeldi, D.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Joy, A.;
Jillings, C. J.;
Kamaev, O.;
Kaur, G.;
Kemp, A.;
Kochanek, I.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Li, X.;
Litvinov, O.;
Lock, J.;
Longo, G.;
Majewski, P.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pesudo, V.;
Piro, M. -C.;
Pollmann, T. R.;
Rand, E. T.;
Rethmeier, C.;
Retière, F.;
García, E. Sanchez;
Santorelli, R.;
Seeburn, N.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Viel, S.;
Walding, J.;
Waqar, M.;
Ward, M.;
Westerdale, S.;
Willis, J.;
Zuñiga-Reyes, A.
Submitted: 2019-05-14
The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne
single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB.
The experimental signature of dark matter interactions is keV-scale $^{40}$Ar
nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by
PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced
by $\beta$ and $\gamma$-rays originating from internal and external
radioactivity in the detector material. A background model of the ER
interactions in DEAP-3600 was developed and is described in this work. The
model is based on several components which are expected from radioisotopes in
the LAr, from ex-situ material assay measurements, and from dedicated
independent in-situ analyses. This prior information is used in a Bayesian fit
of the ER components to a 247.2 d dataset to model the radioactivity in the
surrounding detector materials. While excellent discrimination between ERs and
NRs is reached with pulse shape discrimination, utilizing the large difference
between fast and slow components of LAr scintillation light, detailed knowledge
of the ER background and activity of detector components, sets valuable
constraints on other key types of backgrounds in the detector: neutrons and
alphas. In addition, the activity of $^{42}$Ar in LAr in DEAP-3600 is
determined by measuring the daughter decay of $^{42}$K. This cosmogenically
activated trace isotope is a relevant background at higher energies for other
rare event searches using atmospheric argon e.g. DarkSide-20k, GERDA or LEGEND.
The specific activity of $^{42}$Ar in the atmosphere is found to be $40.4 \pm
5.9$ $\mu$Bq/kg of argon.
[3]
oai:arXiv.org:1902.08960 [pdf] - 1890376
Precision laser-based measurements of the single electron response of
SPCs for the NEWS-G light dark matter search experiment
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Bard, J. -P.;
Brossard, A.;
Chapellier, M.;
Clark, M.;
Crawford, S.;
Corcoran, E. C.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Giroux, G.;
Gorel, P.;
Gros, M.;
Gros, P.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Knights, P.;
Langrock, S.;
Lautridou, P.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Nikolopoulos, K.;
Piquemal, F.;
Piro, M. -C.;
Santos, D.;
Savvidis, G.;
Savvidis, I.;
Fernandez, F. Vazquez de Sola;
Vidal, M.;
Zampaolo, M.
Submitted: 2019-02-24
Spherical Proportional Counters (SPCs) are a novel gaseous detector
technology employed by the NEWS-G low-mass dark matter search experiment for
their high sensitivity to single electrons from ionization. In this paper, we
report on the first characterization of the single electron response of SPCs
with unprecedented precision, using a UV-laser calibration system. The
experimental approach and analysis methodology are presented along with various
direct applications for the upcoming next phase of the experiment at SNOLAB.
These include the continuous monitoring of the detector response and electron
drift properties during dark matter search runs, as well as the experimental
measurement of the trigger threshold efficiency. We measure a mean ionization
energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$
for 2.8 keV X-rays, and demonstrate the feasibility of performing similar
precision measurements at sub-keV energies for future gas mixtures to be used
for dark matter searches at SNOLAB.
[4]
oai:arXiv.org:1707.08042 [pdf] - 1735166
First results from the DEAP-3600 dark matter search with argon at SNOLAB
Collaboration, DEAP-3600;
:;
Amaudruz, P. -A.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bishop, D.;
Bonatt, J.;
Boorman, G.;
Boulay, M. G.;
Broerman, B.;
Bromwich, T.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Chan, S.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Dittmeier, S.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Giampa, P.;
Golovko, V. V.;
Gorel, P.;
Gornea, R.;
Grace, E.;
Graham, K.;
Gulyev, E.;
Hakobyan, R.;
Hall, A.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Jillings, C. J.;
Kamaev, O.;
Kemp, A.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Lidgard, J. J.;
Lim, C.;
Lindner, T.;
Linn, Y.;
Liu, S.;
Majewski, P.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mead, S.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Muir, A.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ohlmann, C.;
Olchanski, K.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T. R.;
Rand, E. T.;
Rau, W.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Shaw, B.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Taylor, J.;
Veloce, L.;
Vázquez-Jáuregui, E.;
Walding, J.;
Ward, M.;
Westerdale, S.;
Woolsey, E.;
Zielinski, J.
Submitted: 2017-07-25, last modified: 2018-08-13
This paper reports the first results of a direct dark matter search with the
DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was
performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target
mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg
capacity. The LAr is viewed by an array of PMTs, which would register
scintillation light produced by rare nuclear recoil signals induced by dark
matter particle scattering. An analysis of 4.44 live days (fiducial exposure of
9.87 tonne-days) of data taken with the nearly full detector during the initial
filling phase demonstrates the detector performance and the best electronic
recoil rejection using pulse-shape discrimination in argon, with leakage
$<1.2\times 10^{-7}$ (90% C.L.) between 16 and 33 keV$_{ee}$. No candidate
signal events are observed, which results in the leading limit on WIMP-nucleon
spin-independent cross section on argon, $<1.2\times 10^{-44}$ cm$^2$ for a 100
GeV/c$^2$ WIMP mass (90% C.L.).
[5]
oai:arXiv.org:1712.01982 [pdf] - 1832993
Design and Construction of the DEAP-3600 Dark Matter Detector
Amaudruz, P. -A.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bishop, D.;
Bonatt, J.;
Boorman, G.;
Boulay, M. G.;
Broerman, B.;
Bromwich, T.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Chan, S.;
Chen, M.;
Chouinard, R.;
Churchwell, S.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Dittmeier, S.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Giampa, P.;
Golovko, V. V.;
Gorel, P.;
Gornea, R.;
Grace, E.;
Graham, K.;
Grant, D. R.;
Gulyev, E.;
Hall, A.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Jillings, C. J.;
Kamaev, O.;
Kemp, A.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Lim, C.;
Lindner, T.;
Linn, Y.;
Liu, S.;
Majewski, P.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
McGinn, T.;
McLaughlin, J. B.;
Mead, S.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Muir, A.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ohlmann, C.;
Olchanski, K.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T. R.;
Rand, E. T.;
Rau, W.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Shaw, B.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Taylor, J.;
Veloce, L.;
Vázquez-Jáuregui, E.;
Walding, J.;
Ward, M.;
Westerdale, S.;
White, R.;
Woolsey, E.;
Zielinski, J.
Submitted: 2017-12-05, last modified: 2018-04-10
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has
been designed for a direct detection search for particle dark matter using a
single-phase liquid argon target. The projected cross section sensitivity for
DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive
Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$
WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the
physical properties and construction of the DEAP-3600 detector.
[6]
oai:arXiv.org:1706.04934 [pdf] - 1604802
First results from the NEWS-G direct dark matter search experiment at
the LSM
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Asner, D.;
Bard, J. -P.;
Brossard, A.;
Cai, B.;
Chapellier, M.;
Clark, M.;
Corcoran, E. C.;
Dandl, T.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Gorel, P.;
Gros, M.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Navick, X. -F.;
Papaevangelou, T.;
Piquemal, F.;
Roth, S.;
Santos, D.;
Savvidis, I.;
Ulrich, A.;
Fernandez, F. Vazquez de Sola;
Zampaolo, M.
Submitted: 2017-06-15, last modified: 2017-09-07
New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection
experiment using Spherical Proportional Counters (SPCs) with light noble gases
to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report
the results from the first physics run taken at the Laboratoire Souterrain de
Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a
mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total
exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the
spin-independent WIMP-nucleon scattering cross-section in the
sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times
\mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5
$\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are
promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to
be installed at SNOLAB by summer 2018.
[7]
oai:arXiv.org:1704.01882 [pdf] - 1565347
Application of the TPB Wavelength Shifter to the DEAP-3600 Spherical
Acrylic Vessel Inner Surface
Broerman, B.;
Boulay, M. G.;
Cai, B.;
Cranshaw, D.;
Dering, K.;
Florian, S.;
Gagnon, R.;
Giampa, P.;
Gilmour, C.;
Hearns, C.;
Kezwer, J.;
Kuźniak, M.;
Pollmann, T.;
Ward, M.
Submitted: 2017-04-06
DEAP-3600 uses liquid argon contained in a spherical acrylic vessel as a
target medium to perform a sensitive spin-independent dark matter search. Argon
scintillates in the vacuum ultraviolet spectrum, which requires wavelength
shifting to convert the VUV photons to visible so they can be transmitted
through the acrylic light guides and detected by the surrounding
photomultiplier tubes. The wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene
was evaporatively deposited to the inner surface of the acrylic vessel under
vacuum. Two evaporations were performed on the DEAP-3600 acrylic vessel with an
estimated coating thickness of 3.00 $\pm$ 0.02 $\mu$m which is successfully
wavelength shifting with liquid argon in the detector. Details on the
wavelength shifter coating requirements, deposition source, testing, and final
performance are presented.
[8]
oai:arXiv.org:0904.2930 [pdf] - 1488343
Measurement of the scintillation time spectra and pulse-shape
discrimination of low-energy beta and nuclear recoils in liquid argon with
DEAP-1
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bonatt, J.;
Boudjemline, K.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
Duncan, F.;
Fatemighomi, N.;
Ford, R.;
Gagnon, R.;
Giampa, P.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Grace, E.;
Graham, K.;
Grant, D. R.;
Hakobyan, R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P.;
Hearns, C.;
Hofgartner, J.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
La Zia, F.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Lippincott, W. H.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
Mehdiyev, R.;
McKinsey, D. N.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J.;
Noble, A. J.;
O'Dwyer, E.;
Olsen, K.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T.;
Rau, W.;
Retière, F.;
Ronquest, M.;
Seeburn, N.;
Skensved, P.;
Smith, B.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Walding, J.;
Ward, M.
Submitted: 2009-04-20, last modified: 2016-09-14
The DEAP-1 low-background liquid argon detector was used to measure
scintillation pulse shapes of electron and nuclear recoil events and to
demonstrate the feasibility of pulse-shape discrimination (PSD) down to an
electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction
of beta events that are misidentified as nuclear recoils to be $<1.4\times
10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil
acceptance of at least 90%, with 4% systematic uncertainty on the absolute
energy scale. The discrimination measurement on surface was limited by nuclear
recoils induced by cosmic-ray generated neutrons. This was improved by moving
the detector to the SNOLAB underground laboratory, where the reduced background
rate allowed the same measurement with only a double-coincidence tag.
The combined data set contains $1.23\times10^8$ events. One of those, in the
underground data set, is in the nuclear-recoil region of interest. Taking into
account the expected background of 0.48 events coming from random pileup, the
resulting upper limit on the electronic recoil contamination is
$<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil
acceptance of at least 90%, with 6% systematic uncertainty on the absolute
energy scale.
We developed a general mathematical framework to describe PSD parameter
distributions and used it to build an analytical model of the distributions
observed in DEAP-1. Using this model, we project a misidentification fraction
of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for
a detector with 8 PE/keVee light yield. This reduction enables a search for
spin-independent scattering of WIMPs from 1000 kg of liquid argon with a
WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming
negligible contribution from nuclear recoil backgrounds.
[9]
oai:arXiv.org:1410.7673 [pdf] - 1416317
DEAP-3600 Dark Matter Search
DEAP Collaboration;
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bonatt, J.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Butcher, A.;
Cai, B.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Dering, K.;
DiGioseffo, J.;
Duncan, F.;
Flower, T.;
Ford, R.;
Giampa, P.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Guliyev, E.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
Li, O.;
Liimatainen, P.;
Majewski, P.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
Ouellet, C.;
Palladino, K.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T.;
Rau, W.;
Retière, F.;
Seeburn, N.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Walding, J.;
Ward, M.
Submitted: 2014-10-27, last modified: 2015-08-25
The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury,
Ontario. It is a single-phase detector that searches for dark matter particle
interactions within a 1000-kg fiducial mass target of liquid argon. A first
generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass
demonstrated a high level of pulse-shape discrimination (PSD) for reducing
$\beta$/$\gamma$ backgrounds and helped to develop low radioactivity techniques
to mitigate surface-related $\alpha$ backgrounds. Construction of the DEAP-3600
detector is nearly complete and commissioning is starting in 2014. The target
sensitivity to spin-independent scattering of Weakly Interacting Massive
Particles (WIMPs) on nucleons of 10$^{-46}$ cm$^2$ will allow one order of
magnitude improvement in sensitivity over current searches at 100 GeV WIMP
mass. This paper presents an overview and status of the DEAP-3600 project and
discusses plans for a future multi-tonne experiment, DEAP-50T.
[10]
oai:arXiv.org:1408.1914 [pdf] - 1216195
Improving Photoelectron Counting and Particle Identification in
Scintillation Detectors with Bayesian Techniques
Akashi-Ronquest, M.;
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bodmer, M.;
Boulay, M. G.;
Broerman, B.;
Buck, B.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chen, Y.;
Cleveland, B.;
Coakley, K.;
Dering, K.;
Duncan, F. A.;
Formaggio, J. A.;
Gagnon, R.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grace, E.;
Guerrero, N.;
Guiseppe, V.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Henning, R.;
Hime, A.;
Hofgartner, J.;
Jaditz, S.;
Jillings, C. J.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Kuzniak, M.;
LaTorre, A.;
Lawson, I.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Linden, S.;
McFarlane, K.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mathew, R.;
McDonald, A. B.;
Mei, D. -M.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J. A.;
Noble, T.;
O'Dwyer, E.;
Olsen, K.;
Gann, G. D. Orebi;
Ouellet, C.;
Palladino, K.;
Pasuthip, P.;
Perumpilly, G.;
Pollmann, T.;
Rau, P.;
Retiere, F.;
Rielage, K.;
Schnee, R.;
Seibert, S.;
Skensved, P.;
Sonley, T.;
Vazquez-Jauregui, E.;
Veloce, L.;
Walding, J.;
Wang, B.;
Wang, J.;
Ward, M.;
Zhang, C.
Submitted: 2014-08-08, last modified: 2014-12-12
Many current and future dark matter and neutrino detectors are designed to
measure scintillation light with a large array of photomultiplier tubes (PMTs).
The energy resolution and particle identification capabilities of these
detectors depend in part on the ability to accurately identify individual
photoelectrons in PMT waveforms despite large variability in pulse amplitudes
and pulse pileup. We describe a Bayesian technique that can identify the times
of individual photoelectrons in a sampled PMT waveform without deconvolution,
even when pileup is present. To demonstrate the technique, we apply it to the
general problem of particle identification in single-phase liquid argon dark
matter detectors. Using the output of the Bayesian photoelectron counting
algorithm described in this paper, we construct several test statistics for
rejection of backgrounds for dark matter searches in argon. Compared to simpler
methods based on either observed charge or peak finding, the photoelectron
counting technique improves both energy resolution and particle identification
of low energy events in calibration data from the DEAP-1 detector and
simulation of the larger MiniCLEAN dark matter detector.
[11]
oai:arXiv.org:1211.0909 [pdf] - 890838
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Boudjemline, K.;
Caldwell, M. G. Boulay B. Cai T.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Contreras, D.;
Dering, K.;
Duncan, F.;
Ford, R.;
Giuliani, R. Gagnon F.;
Golovko, M. Gold V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hakobyan, R.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
Li, O.;
Lidgard, J.;
Liimatainen, P.;
Lippincott, W. H.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
McKinsey, D.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J.;
Noble, T.;
O'Dwyer, E.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Pollmann, T.;
Rau, W.;
Retiere, F.;
Ronquest, M.;
Skensved, P.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Ward, M.
Submitted: 2012-11-05, last modified: 2014-04-23
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was
operated underground at SNOLAB in order to test the techniques and measure the
backgrounds inherent to single phase detection, in support of the
\mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled
through material selection, construction techniques, pulse shape discrimination
and event reconstruction. This report details the analysis of background events
observed in three iterations of the DEAP-1 detector, and the measures taken to
reduce them.
The $^{222}$Rn decay rate in the liquid argon was measured to be between 16
and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background
spectrum near the region of interest for Dark Matter detection in the DEAP-1
detector can be described considering events from three sources: radon
daughters decaying on the surface of the active volume, the expected rate of
electromagnetic events misidentified as nuclear recoils due to inefficiencies
in the pulse shape discrimination, and leakage of events from outside the
fiducial volume due to imperfect position reconstruction. These backgrounds
statistically account for all observed events, and they will be strongly
reduced in the DEAP-3600 detector due to its higher light yield and simpler
geometry.