Deines-Jones, P.
Normalized to: Deines-Jones, P.
3 article(s) in total. 11 co-authors, from 1 to 2 common article(s). Median position in authors list is 3,0.
[1]
oai:arXiv.org:astro-ph/0701090 [pdf] - 88219
An X-ray Polarimeter for Constellation-X
Submitted: 2007-01-04
Polarimetry remains a largely unexploited technique in observational X-ray
astronomy which could provide insight in the study of the strong gravity and
magnetic fields at the core of the Constellation-X observational program.
Adding a polarization capability to the Constellation-X instrumentation would
be immensely powerful. It would make Constellation the first space observatory
to simultaneously measure all astrophysically relevant parameters of source
X-ray photons; their position (imaging), energy (spectroscopy), arrival time
(timing), and polarization. Astrophysical polarimetry requires sensitive
well-calibrated instruments. Many exciting objects are extra-galactic (i.e.
faint) and may have small polarization. Recent advances in efficiency and
bandpass make it attractive to consider a polarimetry Science Enhancement
Package for the Constellation-X mission.
[2]
oai:arXiv.org:physics/0305025 [pdf] - 1238069
The imaging X-ray detector for Lobster-ISS
Submitted: 2003-05-07
Lobster-ISS is a revolutionary astrophysical X-ray all-sky monitor scheduled
for deployment as an attached payload on the International Space Station (ISS)
in 2009. Using a new wide field-of-view focusing optic, Lobster-ISS provides an
order-of-magnitude improvement in the sensitivity of all-sky monitors in the
soft X-ray band (0.1-3.0 keV). This lobster-eye optic presents unique
challenges to the imaging X-ray detector at its focus. Micro-patterned imaging
proportional counters, with thier mechanical simplicity and high performance,
are the most practical means of meeting the requirements. We describe our
design for the Lobster-ISS imaging detector based on direct-imaging micro-well
proportional counters and the expected performance.
[3]
oai:arXiv.org:physics/0303114 [pdf] - 1238067
X-ray polarimetry with an active-matrix pixel proportional counter
Submitted: 2003-03-27
We report the first results from an X-ray polarimeter with a micropattern gas
proportional counter using an amorphous silicon active matrix readout. With
100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33 +/-
0.03, confirming previous reports of the high polarization sensitivity of a
finely segmented pixel proportional counter. The detector described here has a
geometry suitable for the focal plane of an astronomical X-ray telescope.
Amorphous silicon readout technology will enable additional extensions and
improvements.