Normalized to: Defay, X.
[1]
oai:arXiv.org:1905.07335 [pdf] - 2075555
Description of CRESST-III Data
CRESST Collaboration;
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Defay, X.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Fichtinger, S.;
Iachellini, N. Ferreiro;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Jochum, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Münster, A.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoglu, C.;
Usherov, I.;
Willers, M.;
Zema, V.
Submitted: 2019-05-17, last modified: 2020-04-06
In CRESST-III, 10 cryogenic detector modules optimized for low energy
thresholds were operated for almost two years (May 2016 - February 2018).
Together with this document we are publishing data from the best performing
detector module which has a nuclear recoil threshold of 30.1eV. With this
data-set we were able to set limits on the cross-section for spin-dependent and
spin-independent elastic scattering of dark matter particles off nuclei at dark
matter masses down to 160MeV/c$^2$. We publish the energies of all events after
data selection as well as of all events within the acceptance region for
dark-matter searches. In this document we describe how to use these data sets.
[2]
oai:arXiv.org:1902.07587 [pdf] - 2045154
First results on sub-GeV spin-dependent dark matter interactions with
$^{7}$Li
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Defay, X.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Fichtinger, S.;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Jochum, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Münster, A.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoglu, C.;
Usherov, I.;
Willers, M.;
Zema, V.;
Chapellier, M.;
Giuliani, A.;
Nones, C.;
Poda, D. V.;
Shlegel, V. N.;
Velázquez, M.;
Zolotarova, A. S.
Submitted: 2019-02-20, last modified: 2019-09-04
In this work, we want to highlight the potential of lithium as a target for
spin-dependent dark matter search in cryogenic experiments, with a special
focus on the low-mass region of the parameter space. We operated a prototype
detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground
laboratory. Despite the high background environment, the detector sets
competitive limits on spin-dependent interactions of dark matter particles with
protons and neutrons for masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$.
[3]
oai:arXiv.org:1904.00498 [pdf] - 2007901
First results from the CRESST-III low-mass dark matter program
CRESST Collaboration;
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Defay, X.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Fichtinger, S.;
Iachellini, N. Ferreiro;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Jochum, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Münster, A.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoglu, C.;
Usherov, I.;
Willers, M.;
Zema, V.
Submitted: 2019-03-31
The CRESST experiment is a direct dark matter search which aims to measure
interactions of potential dark matter particles in an earth-bound detector.
With the current stage, CRESST-III, we focus on a low energy threshold for
increased sensitivity towards light dark matter particles. In this manuscript
we describe the analysis of one detector operated in the first run of
CRESST-III (05/2016-02/2018) achieving a nuclear recoil threshold of 30.1eV.
This result was obtained with a 23.6g CaWO$_4$ crystal operated as a cryogenic
scintillating calorimeter in the CRESST setup at the Laboratori Nazionali del
Gran Sasso (LNGS). Both the primary phonon/heat signal and the simultaneously
emitted scintillation light, which is absorbed in a separate
silicon-on-sapphire light absorber, are measured with highly sensitive
transition edge sensors operated at ~15mK. The unique combination of these
sensors with the light element oxygen present in our target yields sensitivity
to dark matter particle masses as low as 160MeV/c$^2$.
[4]
oai:arXiv.org:1802.08639 [pdf] - 1639827
A prototype detector for the CRESST-III low-mass dark matter search
Strauss, R.;
Angloher, G.;
Bauer, P.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Hampf, R.;
Hauff, D.;
Kiefer, M.;
Lanfranchi, J. -C.;
Langenkämper, A.;
Mondragon, E.;
Münster, A.;
Oppenheimer, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schönert, S.;
Seidel, W.;
Steiger, H.;
Stodolsky, L.;
Tanzke, A.;
Thi, H. H. Trinh;
Ulrich, A.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2018-02-23
The CRESST-III experiment which is dedicated to low-mass dark matter search
uses scintillating CaWO$_4$ crystals operated as cryogenic particle detectors.
Background discrimination is achieved by exploiting the scintillating light
signal of CaWO$_4$ and by a novel active detector holder presented in this
paper. In a test setup above ground, a nuclear-recoil energy threshold of
$E_{th}=(190.6\pm5.2)$eV is reached with a 24g prototype detector, which
corresponds to an estimated threshold of $\sim$50eV when being operated in the
low-noise CRESST cryostat. This is the lowest threshold reported for direct
dark matter searches. For CRESST-III phase 1, ten such detector modules were
installed in the cryostat which have the potential to improve significantly the
sensitivity to scatterings of dark matter particles with masses down to
$\sim$0.1GeV/c$^2$.
[5]
oai:arXiv.org:1703.07152 [pdf] - 1648551
Low-Temperature Relative Reflectivity Measurements of Reflective and
Scintillating Foils used in Rare Event Searches
Langenkämper, A.;
Ulrich, A.;
Defay, X.;
Feilitzsch, F. v.;
Lanfranchi, J. -C.;
Mondragón, E.;
Münster, A.;
Oppenheimer, C.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Steiger, H.;
Thi, H. H. Trinh;
Wawoczny, S.;
Willers, M.;
Zöller, A.
Submitted: 2017-03-21, last modified: 2017-12-20
In this work we investigate the reflectivity of highly reflective multilayer
polymer foils used in the CRESST experiment. The CRESST experiment searches
directly for dark matter via operating scintillating CaWO$_4$ crystals as
targets for elastic dark matter-nucleon scattering. In order to suppress
background events, the experiment employs the so-called phonon-light technique
which is based on the simultaneous measurement of the heat signal in the main
CaWO$_4$ target crystal and of the emitted scintillation light with a separate
cryogenic light detector. Both detectors are surrounded by a highly reflective
and scintillating multilayer polymer foil to increase the light collection
efficiency and to veto surface backgrounds. While this study is motivated by
the CRESST experiment, the results are also relevant for other rare event
searches using scintillating cryogenic bolometers in the field of the search of
dark matter and neutrinoless double beta decay ($0\nu\beta\beta$). In this work
a dedicated experiment has been set up to determine the relative reflectivity
at 300 K and 20 K of three multilayer foils ("VM2000", "VM2002", "Vikuiti")
produced by the company 3M. The intensity of a light beam reflected off the
foil is measured with a CCD camera. The ratio of the intensities at 300 K and
20 K corresponds to the relative reflectivity change. The measurements
performed in this work show no significant change in the reflectivity with
temperature for all foils studied.
[6]
oai:arXiv.org:1711.07692 [pdf] - 1591519
First results on low-mass dark matter from the CRESST-III experiment
CRESST collaboration;
Petricca, F.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Lagenkämper, A.;
Loebell, J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Pagliarone, C.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.
Submitted: 2017-11-21
The CRESST experiment, located at Laboratori Nazionali del Gran Sasso in
Italy, searches for dark matter particles via their elastic scattering off
nuclei in a target material. The CRESST target consists of scintillating
CaWO$_4$ crystals, which are operated as cryogenic calorimeters at millikelvin
temperatures. Each interaction in the CaWO$_4$ target crystal produces a phonon
signal and a light signal that is measured by a second cryogenic calorimeter.
Since the CRESST-II result in 2015, the experiment is leading the field of
direct dark matter search for dark matter masses below 1.7\,GeV/$c^2$,
extending the reach of direct searches to the sub-GeV/$c^2$ mass region. For
CRESST-III, whose Phase 1 started in July 2016, detectors have been optimized
to reach the performance required to further probe the low-mass region with
unprecedented sensitivity. In this contribution the achievements of the
CRESST-III detectors will be discussed together with preliminary results and
perspectives of Phase 1.
[7]
oai:arXiv.org:1711.01285 [pdf] - 1590722
Search for low-mass Dark Matter with the CRESST Experiment
Kluck, H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Langenkämper, A.;
Loebell, J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.
Submitted: 2017-11-03
CRESST is a multi-stage experiment directly searching for dark matter (DM)
using cryogenic $\mathrm{CaWO_4}$ crystals. Previous stages established leading
limits for the spin-independent DM-nucleon cross section down to DM-particle
masses $m_\mathrm{DM}$ below $1\,\mathrm{GeV/c^2}$. Furthermore, CRESST
performed a dedicated search for dark photons (DP) which excludes new parameter
space between DP masses $m_\mathrm{DP}$ of $300\,\mathrm{eV/c^2}$ to
$700\,\mathrm{eV/c^2}$.
In this contribution we will discuss the latest results based on the previous
CRESST-II phase 2 and we will report on the status of the current CRESST-III
phase 1: in this stage we have been operating 10 upgraded detectors with
$24,\mathrm{g}$ target mass each and enhanced detector performance since summer
2016. The improved detector design in terms of background suppression and
reduction of the detection threshold will be discussed with respect to the
previous stage. We will conclude with an outlook on the potential of the next
stage, CRESST-III phase 2.
[8]
oai:arXiv.org:1707.06749 [pdf] - 1586208
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter
operated above ground
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, A. Langenkämper J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Oberauer, L.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoglu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2017-07-20, last modified: 2017-09-18
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a
natural and well-motivated alternative to so-far unobserved weakly interacting
massive particles. Gram-scale cryogenic calorimeters provide the required
detector performance to detect these particles and extend the direct dark
matter search program of CRESST. A prototype 0.5 g sapphire detector developed
for the $\nu$-cleus experiment has achieved an energy threshold of
$E_{th}=(19.7\pm 0.9)$ eV, which is one order of magnitude lower than previous
results and independent of the type of particle interaction. The result
presented here is obtained in a setup above ground without significant
shielding against ambient and cosmogenic radiation. Although operated in a
high-background environment, the detector probes a new range of light-mass dark
matter particles previously not accessible by direct searches. We report the
first limit on the spin-independent dark matter particle-nucleon cross section
for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
[9]
oai:arXiv.org:1708.01581 [pdf] - 1586787
Performance of a CRESST-II Detector Module with True $4\pi$-veto
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Langenkämper, A.;
Loebell, J.;
Mancuso, M.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, V. Schipperges S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2017-08-04
Scintillating, cryogenic bolometers are widely used in the field of rare
event searches. Their main advantages are an excellent energy resolution and
particle identification on an event-by-event basis. The sensitivity of
experiments applying this detector technique can be limited by the performance
of the light channel and the presence of external backgrounds in the region of
interest. In the framework of the CRESST-II experiment, we developed and
successfully tested a novel detector design addressing both challenges. Using a
large scale ($\approx$\unit[60]{cm$^2$}), beaker-shaped silicon light absorber,
the signal height recorded in the light channel is improved by a factor 2.5
compared to conventional CRESTT-II detector modules. In combination with a
large carrier crystal, a true $4\pi$ veto system is established which allows to
tag external background sources.
[10]
oai:arXiv.org:1611.02113 [pdf] - 1509578
Direct Dark Matter Search with the CRESST II Experiment
Schieck, J;
Angloher, G;
Bento, A;
Bucci, C;
Canonica, L;
Defay, X;
Erb, A;
Feilitzsch, F v;
Iachellini, N Ferreiro;
Gorla, P;
Guetlein, A;
Hauff, D;
Jochum, J;
Kiefer, M;
Kluck, H;
Kraus, H;
Lanfranchi, J-C;
Loebell, J;
Mancuso, M;
Muenster, A;
Pagliarone, C;
Petricca, F;
Potzel, W;
Pröbst, F;
Puig, R;
Reindl, F;
Schaeffner, K;
Schoenert, S;
Seidel, W;
Stahlberg, M;
Stodolsky, L;
Strandhagen, C;
Strauss, R;
Tanzke, A;
Thi, H H Trinh;
Turkoglu, C;
Uffinger, M;
Ulrich, A;
Usherov, I;
Wawoczny, S;
Willers, M;
Wueustrich, M;
Zoeller, A
Submitted: 2016-11-07
The quest for the particle nature of dark matter is one of the big open
questions of modern physics. A well motivated candidate for dark matter is the
so-called WIMP - a weakly interacting massive particle. Recently several
theoretically well-motivated models with dark matter candidates in a mass
region below the WIMP mass-scale gained also a lot of interest, theoretically
and experimentally. The CRESST II experiment located at the Gran Sasso
laboratory in Italy is optimised for the detection of the elastic scattering of
these low-mass dark matter particles with ordinary matter. We show the results
obtained with an improved detector setup with increased radio purity and
enhanced background rejection and the results obtained with a dedicated
low-threshold analysis of a single conventional detector module. The limit
achieved is the most stringent limit achieved for direct dark matter
experiments in the mass region below 1.8 GeV/$c^{2}$. We will discuss the
expected performance for new small CRESST-type detectors to be used during the
next data taking phase. We conclude with an outlook of the future potential for
direct dark matter detection using further improved CRESST CaWO$_{4}$ cryogenic
detectors.
[11]
oai:arXiv.org:1601.04447 [pdf] - 1439730
Limits on momentum-dependent asymmetric dark matter with CRESST-II
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2016-01-18, last modified: 2016-07-19
The usual assumption in direct dark matter searches is to only consider the
spin-dependent or spin-independent scattering of dark matter particles.
However, especially in models with light dark matter particles
$\mathcal{O}(\mathrm{GeV/c^2})$, operators which carry additional powers of the
momentum transfer $q^2$ can become dominant. One such model based on asymmetric
dark matter has been invoked to overcome discrepancies in helioseismology and
an indication was found for a particle with preferred mass of 3
$\mathrm{GeV/c^2}$ and cross section of $10^{-37} \mathrm{cm^2}$. Recent data
from the CRESST-II experiment, which uses cryogenic detectors based on
$\mathrm{CaWO_4}$ to search for nuclear recoils induced by dark matter
particles, are used to constrain these momentum-dependent models. The low
energy threshold of 307 eV for nuclear recoils of the detector used, allows us
to rule out the proposed best fit value above.
[12]
oai:arXiv.org:1509.01515 [pdf] - 1357396
Results on light dark matter particles with a low-threshold CRESST-II
detector
The CRESST Collaboration;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Loebell, J.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-09-04, last modified: 2016-02-12
The CRESST-II experiment uses cryogenic detectors to search for nuclear
recoil events induced by the elastic scattering of dark matter particles in
CaWO$_4$ crystals. Given the low energy threshold of our detectors in
combination with light target nuclei, low mass dark matter particles can be
probed with high sensitivity. In this letter we present the results from data
of a single detector module corresponding to 52 kg live days. A blind analysis
is carried out. With an energy threshold for nuclear recoils of 307 eV we
substantially enhance the sensitivity for light dark matter. Thereby, we extend
the reach of direct dark matter experiments to the sub-region and demonstrate
that the energy threshold is the key parameter in the search for low mass dark
matter particles.
[13]
oai:arXiv.org:1509.06266 [pdf] - 1378623
Cryogenic silicon detectors with implanted contacts for the detection of
visible photons using the Neganov-Luke Effect
Defay, X.;
Mondragon, E.;
Willers, M.;
Langenkamper, A.;
Lanfranchi, J. -C.;
Munstera, A.;
Zoller, A.;
Wawoczny, S.;
Steiger, H.;
Hitzler, F.;
Bruhn, C.;
Schonert, S.;
Potzel, W.;
Chapellier, M.
Submitted: 2015-09-21, last modified: 2016-01-28
There is a common need in astroparticle experiments such as direct dark
matter detection, 0{\nu}\b{eta}\b{eta} (double beta decay without emission of
neutrinos) and Coherent Neutrino Nucleus Scattering experiments for light
detectors with a very low energy threshold. By employing the Neganov-Luke
Effect, the thermal signal of particle interactions in a semiconductor absorber
operated at cryogenic temperatures, can be amplified by drifting the
photogenerated electrons and holes in an electric field. This technology is not
used in current experiments, in particular because of a reduction of the signal
amplitude with time which is due to trapping of the charges within the
absorber. We present here the first results of a novel type of Neganov-Luke
Effect detector with an electric field configuration designed to improve the
charge collection within the semiconductor.
[14]
oai:arXiv.org:1509.09124 [pdf] - 1286174
The CRESST Dark Matter Search - Status and Perspectives
The CRESST Collaboration;
Reindl, F.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Loebell, J.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-09-30
In the past years the spotlight of the search for dark matter particles
widened to the low mass region, both from theoretical and experimental side. We
discuss results from data obtained in 2013 with a single detector TUM40. This
detector is equipped with a new upgraded holding scheme to efficiently veto
backgrounds induced by surface alpha decays. This veto, the low threshold of
0.6keV and an unprecedented background level for CaWO$_4$ target crystals
render TUM40 the detector with the best overall performance of CRESST-II phase
2 (July 2013 - August 2015). A low-threshold analysis allowed to investigate
light dark matter particles (<3GeV/c$^2$), previously not accessible for other
direct detection experiments.
[15]
oai:arXiv.org:1103.4070 [pdf] - 966535
Final results of the EDELWEISS-II WIMP search using a 4-kg array of
cryogenic germanium detectors with interleaved electrodes
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chardin, G.;
Chapellier, M.;
Charlieux, F.;
Coulter, P.;
Cox, G. A.;
Defay, X.;
De Jesus, M.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A-S.;
Vagneron, L.;
Verdier, M-A.;
Walker, R. J.;
Yakushev, E.
Submitted: 2011-03-21, last modified: 2011-08-31
The EDELWEISS-II collaboration has completed a direct search for WIMP dark
matter with an array of ten 400-g cryogenic germanium detectors in operation at
the Laboratoire Souterrain de Modane. The combined use of thermal phonon
sensors and charge collection electrodes with an interleaved geometry enables
the efficient rejection of gamma-induced radioactivity as well as near-surface
interactions. A total effective exposure of 384 kg.d has been achieved, mostly
coming from fourteen months of continuous operation. Five nuclear recoil
candidates are observed above 20 keV, while the estimated background is 3.0
events. The result is interpreted in terms of limits on the cross-section of
spin-independent interactions of WIMPs and nucleons. A cross-section of
4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints
are also set on models where the WIMP-nucleon scattering is inelastic.
[16]
oai:arXiv.org:1105.3377 [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS;
Collaborations, EDELWEISS;
:;
Ahmed, Z.;
Akerib, D. S.;
Armengaud, E.;
Arrenberg, S.;
Augier, C.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Brink, P. L.;
Broniatowski, A.;
Bruch, T.;
Brudanin, V.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Censier, B.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Cooley, J.;
Coulter, P.;
Cox, G. A.;
Cushman, P.;
Daal, M.;
Defay, X.;
De Jesus, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Dragowsky, M. R.;
Eitel, K.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Filosofov, D.;
Fourches, N.;
Fox, J.;
Fritts, M.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Golwala, S. R.;
Gros, M.;
Hall, J.;
Hennings-Yeomans, R.;
Henry, S.;
Hertel, S. A.;
Hervé, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Juillard, A.;
Kamaev, O.;
Kiveni, M.;
Kluck, H.;
Kos, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Leman, S. W.;
Liu, S.;
Loaiza, P.;
Mahapatra, R.;
Mandic, V.;
Marnieros, S.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nadeau, P.;
Navick, X-F.;
Nelson, H.;
Nones, C.;
Ogburn, R. W.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Robinson, M.;
Rozov, S.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sanglard, V.;
Schmidt, B.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Semikh, S.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M. -A.;
Walker, R. J.;
Wikus, P.;
Yakushev, E.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.
[17]
oai:arXiv.org:1006.3098 [pdf] - 190656
A detection system to measure muon-induced neutrons for direct Dark
Matter searches
Kozlov, V. Yu.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X. -F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.
Submitted: 2010-06-15
Muon-induced neutrons constitute a prominent background component in a number
of low count rate experiments, namely direct searches for Dark Matter. In this
work we describe a neutron detector to measure this background in an
underground laboratory, the Laboratoire Souterrain de Modane. The system is
based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of
the EDELWEISS-II experiment for coincident muon detection. The system was
installed in autumn 2008 and passed since then a number of commissioning tests
proving its full functionality. The data-taking is continuously ongoing and a
count rate of the order of 1 muon-induced neutron per day has been achieved.
[18]
oai:arXiv.org:1001.4383 [pdf] - 33100
Monitoring of the thermal neutron flux in the LSM underground laboratory
Rozov, S.;
Armengaud, E.;
Augier, C.;
Bergé, L.;
Benoit, A.;
Besida, O.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Defay, X.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrach, C.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M-A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2010-01-25
This paper describes precise measurements of the thermal neutron flux in the
LSM underground laboratory in proximity of the EDELWEISS-II dark matter search
experiment together with short measurements at various other locations.
Monitoring of the flux of thermal neutrons is accomplished using a mobile
detection system with low background proportional counter filled with $^3$He.
On average 75 neutrons per day are detected with a background level below 1
count per day (cpd). This provides a unique possibility of a day by day study
of variations of the neutron field in a deep underground site. The measured
average 4$\pi$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is
$\Phi_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We
report the first experimental observation that the point-to-point thermal
neutron flux at LSM varies by more than a factor two.
[19]
oai:arXiv.org:0912.0805 [pdf] - 157860
First results of the EDELWEISS-II WIMP search using Ge cryogenic
detectors with interleaved electrodes
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X-F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.;
Collaboration, the EDELWEISS
Submitted: 2009-12-04
The EDELWEISS-II collaboration has performed a direct search for WIMP dark
matter with an array of ten 400 g heat-and-ionization cryogenic detectors
equipped with interleaved electrodes for the rejection of near-surface events.
Six months of continuous operation at the Laboratoire Souterrain de Modane have
been achieved. The observation of one nuclear recoil candidate above 20 keV in
an effective exposure of 144 kgd is interpreted in terms of limits on the
cross-section of spin-independent interactions of WIMPs and nucleons. A
cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80
GeV/c2. This result demonstrates for the first time the very high background
rejection capabilities of these simple and robust detectors in an actual WIMP
search experiment.
[20]
oai:arXiv.org:0905.0753 [pdf] - 369040
A new high-background-rejection dark matter Ge cryogenic detector
Broniatowski, A.;
Defay, X.;
Armengaud, E.;
Berge, L.;
Benoit, A.;
Besida, O.;
Blumer, J.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrache, C.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M. -A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2009-05-06
A new design of a cryogenic germanium detector for dark matter search is
presented, taking advantage of the coplanar grid technique of event
localisation for improved background discrimination. Experiments performed with
prototype devices in the EDELWEISS II setup at the Modane underground facility
demonstrate the remarkably high efficiency of these devices for the rejection
of low-energy $\beta$, approaching 10$^5$ . This opens the road to investigate
the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as
proposed in the EURECA project of a one-ton cryogenic detector mass.
[21]
oai:arXiv.org:astro-ph/0610821 [pdf] - 86245
Identification of backgrounds in the EDELWEISS-I dark matter search
experiment
Fiorucci, S.;
Benoit, A.;
Berge, L.;
Blumer, J.;
Broniatowski, A.;
Censier, B.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Deschamps, H.;
Di Stefano, P.;
Dolgorouky, Y.;
Dumoulin, L.;
Eitel, K.;
Fesquet, M.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Gros, M.;
Horn, M.;
Juillard, A.;
Lemrani, R.;
De Lesquen, A.;
Lubashevskiy, A.;
Luca, M.;
Marnieros, S.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Olivieri, O.;
Pari, P.;
Sanglard, V.;
Schoeffel, L.;
Schwamm, F.;
Stern, M.;
Yakushev, E.
Submitted: 2006-10-27, last modified: 2007-05-10
This paper presents our interpretation and understanding of the different
backgrounds in the EDELWEISS-I data sets. We analyze in detail the several
populations observed, which include gammas, alphas, neutrons, thermal sensor
events and surface events, and try to combine all data sets to provide a
coherent picture of the nature and localisation of the background sources. In
light of this interpretation, we draw conclusions regarding the background
suppression scheme for the EDELWEISS-II phase.
[22]
oai:arXiv.org:astro-ph/0607502 [pdf] - 83705
Measurement of the response of heat-and-ionization germanium detectors
to nuclear recoils
Benoit, A.;
Berge, L.;
Blumer, J.;
Broniatowski, A.;
Censier, B.;
Chantelauze, A.;
/Chapellier, M.;
Chardin, G.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Deschamps, H.;
Di Stefano, P.;
Dolgorouky, Y.;
Dumoulin, L.;
Eitel, K.;
Fesquet, M.;
Fiorucci, S.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Gros, M.;
Horn, M.;
Juillard, A.;
Lemrani, R.;
de Lesquen, A.;
Luca, M.;
Marnieros, S.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Olivieri, E.;
Pari, P.;
Sanglard, V.;
Schoeffel, L.;
Schwamm, F.;
Stern, M.
Submitted: 2006-07-21
The heat quenching factor Q' (the ratio of the heat signals produced by
nuclear and electron recoils of equal energy) of the heat-and-ionization
germanium bolometers used by the EDELWEISS collaboration has been measured. It
is explained how this factor affects the energy scale and the effective
quenching factor observed in calibrations with neutron sources. This effective
quenching effect is found to be equal to Q/Q', where Q is the quenching factor
of the ionization yield. To measure Q', a precise EDELWEISS measurement of Q/Q'
is combined with values of Q obtained from a review of all available
measurements of this quantity in tagged neutron beam experiments. The
systematic uncertainties associated with this method to evaluate Q' are
discussed in detail. For recoil energies between 20 and 100 keV, the resulting
heat quenching factor is Q' = 0.91+-0.03+-0.04, where the two errors are the
contributions from the Q and Q/Q' measurements, respectively. The present
compilation of Q values and evaluation of Q' represent one of the most precise
determinations of the absolute energy scale for any detector used in direct
searches for dark matter.