sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Dedhia, Dhiraj

Normalized to: Dedhia, D.

9 article(s) in total. 37 co-authors, from 1 to 9 common article(s). Median position in authors list is 8,0.

[1]  oai:arXiv.org:1901.09382  [pdf] - 1830671
LAXPC / AstroSat Study of ~ 1 and ~ 2 mHz Quasi-periodic Oscillations in the Be/X-ray Binary 4U 0115+63 During its 2015 Outburst
Comments: Accepted for publication in ApJ
Submitted: 2019-01-27
The Be X-ray Binary 4U 0115+63 was observed by Large Area X-ray Proportional Counter (LAXPC) instrument on AstroSat on 2015 October 24 during the peak of a giant Type II outburst. Prominent intensity oscillations at ~ 1 and ~ 2 mHz frequency were detected during the outburst. Nuclear Spectroscopic Telescope Array (NuSTAR) observations made during the same outburst also show mHz quasi periodic oscillations (QPOs). Details of the oscillations and their characteristics deduced from LAXPC/AstroSat and NuSTAR observations are reported in this paper. Analysis of the archival Rossi X-ray Timing Explorer (RXTE)/Proportional Counter Array (PCA) data during 2001-11 also show presence of mHz QPOs during some of the outbursts and details of these QPOs are also reported. Possible models to explain the origin of the mHz oscillations are examined. Similar QPOs, albeit at higher frequencies, have been reported from other neutron star and black hole sources and both may have a common origin. Current models to explain the instability in the inner accretion disk causing the intense oscillations are discussed.
[2]  oai:arXiv.org:1811.10030  [pdf] - 1791546
Thermonuclear X-ray bursts in rapid succession in 4U 1636-536 with AstroSat-LAXPC
Comments: Accepted for publication in MNRAS
Submitted: 2018-11-25
We present results from an observation of the Low Mass X-ray Binary 4U 1636-536 obtained with the LAXPC instrument aboard AstroSat. The observations of 4U 1636-536 made during the performance verification phase of AstroSat showed seven thermonuclear X-ray bursts in a total exposure of ~ 65 ks over a period of about two consecutive days. Moreover, the light curve of 4U 1636-536 revealed the presence of a rare triplet of X-ray bursts, having a wait time of about 5.5 minutes between second and the third bursts. We also present results from time-resolved spectroscopy performed during these seven X-ray bursts. In addition, we have also detected a transient Quasi-periodic oscillation (QPO) at ~ 5 Hz. However, we did not find any evidence of kilo-hertz QPOs and/or X-ray burst oscillations, perhaps due to the hard spectral state of the source during this observation.
[3]  oai:arXiv.org:1709.06353  [pdf] - 1588543
X-ray timing analysis of Cyg X-3 using AstroSat/LAXPC: Detection of milli-hertz quasi-periodic oscillations during the flaring hard X-ray state
Comments: 16 pages, 10 figures, 3 tables, accepted for publication in ApJ
Submitted: 2017-09-19
We present here results from the X-ray timing and spectral analysis of the X-ray binary Cyg X-3 using observations from Large Area X-ray Proportional Counter (LAXPC) on-board AstroSat. Consecutive lightcurves observed over a period of one year show the binary orbital period of 17253.56 +/- 0.19 sec. Another low-amplitude, slow periodicity of the order of 35.8 +/- 1.4 days is observed which may be due to the orbital precession as suggested earlier by Molteni et al. (1980). During the rising binary phase, power density spectra from different observations during flaring hard X-ray state show quasi-periodic oscillations (QPOs) at ~5-8 mHz, ~12-14 mHz, ~18-24 mHz frequencies at the minimum confidence of 99%. However, during the consecutive binary decay phase, no QPO is detected up to 2-sigma significance. Energy-dependent time-lag spectra show soft lag (soft photons lag hard photons) at the mHz QPO frequency and the fractional rms of the QPO increases with the photon energy. During the binary motion, the observation of mHz QPOs during the rising phase of the flaring hard state may be linked to the increase in the supply of the accreting material in the disk and corona via stellar wind from the companion star. During the decay phase, the compact source moves in the outer wind region causing the decrease in the supply of material for accretion. This may cause weakening of the mHz QPOs below the detection limit. This is also consistent with the preliminary analysis of the orbital phase-resolved energy spectra presented in this paper.
[4]  oai:arXiv.org:1702.08624  [pdf] - 1581666
Calibration of the Large Area X-ray Proportional Counter (LAXPC) instrument on-board AstroSat
Comments: Accepted for publication in ApJS
Submitted: 2017-02-27, last modified: 2017-06-18
We present the calibration and background model for the Large Area X-ray Proportional Counter (LAXPC) detectors on-board AstroSat. LAXPC instrument has three nominally identical detectors to achieve large collecting area. These detectors are independent of each other and in the event analysis mode, they record the arrival time and energy of each photon that is detected. The detectors have a time-resolution of 10 $\mu$s and a dead-time of about 42 $\mu$s. This makes LAXPC ideal for timing studies. The energy resolution and peak channel to energy mapping were obtained from calibration on ground using radioactive sources coupled with GEANT4 simulations of the detectors. The response matrix was further refined from observations of the Crab X-ray source after launch. At around 20 keV the energy resolution of detector is about 10--15\%, while the combined effective area of the 3 detectors is about 6000 cm$^2$.
[5]  oai:arXiv.org:1705.06446  [pdf] - 1583573
Large Area X-ray Proportional Counter (LAXPC) Instrument on AstroSat and Some Preliminary Results from its performance in the orbit
Comments: 11 pages, 15 Figures, Accepted for publication in Journal of Astronomy and Astrophysics
Submitted: 2017-05-18, last modified: 2017-05-25
Large Area X-ray Propositional Counter (LAXPC) instrument on AstroSat is aimed at providing high time resolution X-ray observations in 3 to 80 keV energy band with moderate energy resolution. To achieve large collecting area, a cluster of three co-aligned identical LAXPC detectors, is used to realize an effective area in access of about 6000 cm2 at 15 keV. The large detection volume of the LAXPC detectors, filled with xenon gas at about 2 atmosphere pressure, results in detection efficiency greater than 50%, above 30 keV. In this article, we present salient features of the LAXPC detectors, their testing and characterization in the laboratory prior to launch and calibration in the orbit. Some preliminary results on timing and spectral characteristics of a few X-ray binaries and other type of sources, are briefly discussed to demonstrate that the LAXPC instrument is performing as planned in the orbit.
[6]  oai:arXiv.org:1704.04931  [pdf] - 1582592
AstroSat/LAXPC detection of milli-second phenomena in 4U 1728-34
Comments: Accepted for publication in Astrophysical Journal, 6 figures, five pages
Submitted: 2017-04-17
The low mass X-ray binary 4U 1728-24 was observed with AstroSat/LAXPC on 8th March 2016. Data from a randomly chosen one orbit of over 3 ks was analyzed for detection of rapid intensity variations. We found that the source intensity was nearly steady but towards the end of the observation a typical Type-1 burst was detected. Dynamical power spectrum of the data {in the 3 to 20 keV band, reveals presence of a kHz Quasi-Periodic Oscillation (QPO) whose frequency drifted from around 815 Hz at the beginning of the observation to about 850 Hz just before the burst. The QPO is also detected in the 10 to 20 keV band, which was not obtainable by earlier RXTE observations of this source. Even for such a short observation with a drifting QPO frequency, the time-lag between the 5 to 10 and 10 to 20 keV bands can be constrained to be less than 100 microseconds. The Type-1 burst that lasted for about 20 secs had a typical profile. During the first four secondsdynamic power spectra reveal a burst oscillation whose frequency increased from 361.5 to 363.5Hz. This is consistent with the earlier results obtained with RXTE/PCA, showing the same spin frequency of the neutron star. The present results demonstrate the capability of LAXPC instrument for detecting millisecond variability even from short observations. After RXTE ceased operation, LAXPC on AstroSat is the only instrument at present with capability of detecting kHz QPOs and other kind of rapid variations from 3 keV to 20 keV and possibly at higher energies also.
[7]  oai:arXiv.org:1612.08793  [pdf] - 1533886
AstroSat/LAXPC observation of Cygnus X-1 in the hard state
Comments: 6 pages, 8 figures
Submitted: 2016-12-27
We report the first analysis of data from AstroSat/LAXPC observations of Cygnus X-1 in January 2016. LAXPC spectra reveals that the source was in the canonical hard state, represented by a prominent thermal Comptonization component having a photon index of 1.8 and high temperature kT of electron > 60 keV along with weak reflection and possible disk emission. The power spectrum can be characterized by two broad lorentzian functions centered at 0.4 and 3 Hz. The r.m.s of the low frequency component decreases from 15% at around 4 keV to 10% at around 50 keV, while that of the high frequency one varies less rapidly from 13.5% to 11.5% in the same energy range. The time lag between the hard (20 to 40 keV) and soft (5 to 10 keV) bands varies in a step-like manner being nearly constant at 50 Milli-seconds from 0.3 to 0.9 Hz, decreasing to 8 Milli-seconds from 2 to 5 Hz and finally dropping to 2 Milli-seconds for higher frequencies. The time lags increase with energy for both the low and high frequency components. The event mode LAXPC data allows for flux resolved spectral analysis on a time-scale of 1 second, which clearly shows that the photon index increased from 1.72 to 1.80 as the flux increased by nearly a factor of two. We discuss the results in the framework of the fluctuation propagation model.
[8]  oai:arXiv.org:1609.03531  [pdf] - 1478997
Performance of Large Area X-ray Proportional Counters in a Balloon Experiment
Comments: 23 pages, 14 figures in Experimental Astronomy Astrophysical Instrumentation and Methods August 2016,Vol 42, ISSN 0922-6435
Submitted: 2016-09-12
ASTROSAT is India's first satellite fully devoted to astronomical observations covering a wide spectral band from optical to hard X-rays by a complement of 4 co-aligned instruments and a Scanning Sky X-ray Monitor. One of the instruments is Large Area X-ray Proportional Counter with 3 identical detectors. In order to assess the performance of this instrument, a balloon experiment with two prototype Large Area X-ray Proportional Counters (LAXPC) was carried out on 2008 April 14. The design of these LAXPCs was similar to those on the ASTROSAT except that their field of view (FOV) was 3$^{\circ}$ $\times$ 3$^{\circ}$ versus FOV of 1$^{\circ}$ $\times$ 1$^{\circ}$ for the LAXPCs on the ASTROSAT. The LAXPCs are aimed at the timing and spectral studies of X-ray sources in 3-80 keV region. In the balloon experiment, the LAXPC, associated electronics and support systems were mounted on an oriented platform which could be pre-programmed to track any source in the sky. A brief description of the LAXPC design, laboratory tests, calibration and the detector characteristics is presented here. The details of the experiment and background counting rates of the 2 LAXPCs at the float altitude of about 41 km are presented in different energy bands. The bright black hole X-ray binary Cygnus X-1 (Cyg X-1) was observed in the experiment for $\sim$ 3 hours. Details of Cyg X-1 observations, count rates measured from it in different energy intervals and the intensity variations of Cyg X-1 detected during the observations are presented and briefly discussed.
[9]  oai:arXiv.org:1608.07023  [pdf] - 1531353
AstroSat/LAXPC reveals the high energy variability of GRS 1915+105 in the chi class
Comments: 9 pages, 11 figures
Submitted: 2016-08-25
We present the first quick look analysis of data from nine {\it AstroSat}'s LAXPC observations of GRS 1915+105 during March 2016 when the source had the characteristics of being in Radio-quiet $\chi$ class. We find that a simple empirical model of a disk blackbody emission, with Comptonization and a broad Gaussian Iron line can fit the time averaged 3--80 keV spectrum with a systematic uncertainty of 1.5\% and a background flux uncertainty of 4\%. A simple deadtime-corrected Poisson noise level spectrum matches well with the observed high frequency power spectra till 50 kHz and as expected the data show no significant high frequency ($> 20$ Hz) features. Energy dependent power spectra reveal a strong low frequency (2 - 8 Hz) Quasi-periodic oscillation (LFQPO) and its harmonic along with broad band noise. The QPO frequency changes rapidly with flux (nearly 4 Hz in ~ 5 hours). With increasing QPO frequency, an excess noise component appears significantly in the high energy regime (> 8 keV). At the QPO frequencies, the time-lag as a function of energy has a non-monotonic behavior such that the lags decrease with energy till about 15 -20 keV and then increase for higher energies. These first look results benchmark the performance of LAXPC at high energies and confirms that its data can be used for more sophisticated analysis such as flux or frequency-resolved spectro-timing studies.