sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

de Solorzano, A. Ortiz

Normalized to: De Solorzano, A.

21 article(s) in total. 61 co-authors, from 1 to 20 common article(s). Median position in authors list is 10,0.

[1]  oai:arXiv.org:1812.04519  [pdf] - 1983798
Background assessment for the TREX Dark Matter experiment
Comments: Final version, as accepted in Eur. Phys. J. C
Submitted: 2018-12-11, last modified: 2019-09-22
TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30 kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered acquisition, allowing for thresholds below 0.4 keV (electron equivalent). A low background level in the lowest energy region is another essential requirement. To assess the expected background, all the relevant sources have been considered, including the measured fluxes of gamma radiation, muons and neutrons at the Canfranc Laboratory, together with the activity of most of the components used in the detector and ancillary systems, obtained in a complete assay program. The background contributions have been simulated by means of a dedicated application based on Geant4 and a custom-made code for the detector response. The background model developed for the detector presently installed in Canfranc points to levels from 1 to 10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive in the search for low-mass WIMPs. A roadmap to further decrease it down to 0.1 counts keV-1 kg-1 d-1 is underway.
[2]  oai:arXiv.org:1812.01377  [pdf] - 1890304
Analysis of backgrounds for the ANAIS-112 dark matter experiment
Comments: Final version for publication
Submitted: 2018-12-04, last modified: 2019-05-28
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation or refutation of theDAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique, at the Canfranc Underground Laboratory (LSC) in Spain. ANAIS-112, consisting of nine 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc. in a 3x3matrix configuration, is taking data smoothly in "dark matter search" mode since August, 2017, after a commissioning phase and operation of the first detectors during the last years in various setups. A large effort has been carried out withinANAIS to characterize the background of sodium iodide detectors, before unblinding the data and performing the first annual modulation analysis. Here, the background models developed for all the nine ANAIS-112 detectors are presented. Measured spectra from threshold to high energy in different conditions are well described by the models based on quantified activities independently estimated following several approaches. In the region from 1 to 6 keVee the measured, efficiency corrected background level is 3.58+-0.02 keV-1 kg-1 day-1; NaI crystal bulk contamination is the dominant background source being 210Pb, 40K, 22Na and 3H contributions the most relevant ones. This background level, added to the achieved 1 keVee analysis threshold (thanks to the outstanding light collection and robust filtering procedures developed), allow ANAIS-112 to be sensitive to the modulation amplitude measured by DAMA/LIBRA, and able to explore at three sigma level in 5 years the WIMP parameter region singled out by this experiment.
[3]  oai:arXiv.org:1706.05818  [pdf] - 1598065
Cosmogenic production of tritium in dark matter detectors
Comments: Final version as published
Submitted: 2017-06-19, last modified: 2017-11-24
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and long half-life) when induced in the detector medium, and because it can be generated in any material as a spallation product. Quantification of cosmogenic production of tritium is not straightforward, neither experimentally nor by calculations. In this work, a method for the calculation of production rates at sea level has been developed and applied to some of the materials typically used as targets in dark matter detectors (germanium, sodium iodide, argon and neon); it is based on a selected description of tritium production cross sections over the entire energy range of cosmic nucleons. Results have been compared to available data in the literature, either based on other calculations or from measurements. The obtained tritium production rates, ranging from a few tens to a few hundreds of nuclei per kg and per day at sea level, point to a significant contribution to the background in dark matter experiments, requiring the application of specific protocols for target material purification, material storing underground and limiting the time the detector is on surface during the building process in order to minimize the exposure to the most dangerous cosmic ray components.
[4]  oai:arXiv.org:1710.03837  [pdf] - 1589559
The ANAIS-112 experiment at the Canfranc Underground Laboratory
Comments: To appear in the Proceedings of the XV International Conference on Topics in Astroparticle and Underground Physics (TAUP2017) at Journal of Physics: Conference Series (JPCS)
Submitted: 2017-10-10
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal at the Canfranc Underground Laboratory (LSC). Several 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc. have been operated there during the last years in various set-ups; an outstanding light collection at the level of 15 photoelectrons per keV, which allows triggering at 1 keV of visible energy, has been measured for all of them and a complete characterization of their background has been achieved. In the first months of 2017, the full ANAIS-112 set-up consisting of nine Alpha Spectra detectors with a total mass of 112.5 kg was commissioned at LSC and the first dark matter run started in August, 2017. Here, the latest results on the detectors performance and measured background from the commissioning run will be presented and the sensitivity prospects of the ANAIS-112 experiment will be discussed.
[5]  oai:arXiv.org:1709.10062  [pdf] - 1589033
Status of the TREX-DM experiment at the Canfranc Underground Laboratory
Comments: To appear in the Proceedings of the XV International Conference on Topics in Astroparticle and Underground Physics (TAUP2017) at Journal of Physics: Conference Series (JPCS)
Submitted: 2017-09-28
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a gas time projection chamber equipped with novel micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg of Ne. The micromegas will be read with a self-triggered acquisition, allowing for effective thresholds below 0.4 keV (electron equivalent). The preliminary background model, following a complete material screening program, points to levels of the order of 1-10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive. The status of the commissioning, description of the background model and the corresponding WIMP sensitivity will be presented here.
[6]  oai:arXiv.org:1604.05587  [pdf] - 1460860
Assessment of backgrounds of the ANAIS experiment for dark matter direct detection
Comments: Version as accepted for publication in Eur. Phys. J. C
Submitted: 2016-04-19, last modified: 2016-07-22
A large effort has been carried out to characterize the background of sodium iodide crystals within the ANAIS (Annual modulation with NaI Scintillators) project. In this paper, the background models developed for three 12.5-kg NaI(Tl) scintillators produced by Alpha Spectra Inc. and operated at the Canfranc Underground Laboratory are presented together with an evaluation of the background prospects for the full experiment. Measured spectra from threshold to high energy in different conditions are well described by the models based on quantified activities. At the region of interest, crystal bulk contamination is the dominant background source. Contributions from 210Pb, 40K, 22Na and 3H are the most relevant. Those from 40K and 22Na could be efficiently suppressed thanks to anticoincidence operation in a crystals matrix or inside a Liquid Scintillator Veto (LSV), while that from 210Pb has been reduced by improving crystal production methods and 3H production could be reduced by shielding against cosmic rays during production. Assuming the activities of the last characterized detector, for nine crystals with a total mass of 112.5 kg the expected background rate is 2.5 counts/(keV kg d) in the region from 1 to 4 keV, which could be reduced at 1.4 counts/(keV kg d) by using a LSV.
[7]  oai:arXiv.org:1508.07213  [pdf] - 1268010
Status of the ANAIS Dark Matter Project at the Canfranc Underground Laboratory
Comments: Contributed to the 11th Patras Workshop on Axions, WIMPs and WISPs, Zaragoza, June 22 to 26, 2015
Submitted: 2015-08-28
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal. A detailed analysis of two NaI(Tl) crystals of 12.5 kg each grown by Alpha Spectra will be shown: effective threshold at 1 keVee is at reach thanks to outstanding light collection and robust PMT noise filtering protocols and the measured background is well understood down to 3 keVee, having quantified K, U and Th content and cosmogenic activation in the crystals. A new detector was installed in Canfranc in March 2015 together with the two previous modules and preliminary characterization results will be presented. Finally, the status and expected sensitivity of the full experiment with 112 kg will be reviewed.
[8]  oai:arXiv.org:1410.5949  [pdf] - 886494
ANAIS: Status and prospects
Comments: 7 pages, 3 figures, proceedings of ICHEP2014 conference
Submitted: 2014-10-22
ANAIS (Annual modulation with NAI Scintillators) experiment aims to look for dark matter annual modulation with 250 kg of ultrapure NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC), in order to confirm the DAMA/LIBRA positive signal in a model-independent way. The detector will consist in an array of close-packed single modules, each of them coupled to two high efficiency Hamamatsu photomultipliers. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra are currently taking data at the LSC. These modules have shown an outstanding light collection efficiency (12-16 phe/keV), about the double of that from DAMA/LIBRA phase 1 detectors, which could enable reducing the energy threshold down to 1 keVee. ANAIS crystal radiopurity goals are fulfilled for 232Th and 238U chains, assuming equilibrium, and in the case of 40K, present crystals activity (although not at the required 20 ppb level) could be acceptable. However, a 210Pb contamination out-of-equilibrium has been identified and its origin traced back, so we expect it will be avoided in next prototypes. Finally, current status and prospects of the experiment considering several exposure and background scenarios are presented.
[9]  oai:arXiv.org:astro-ph/0211535  [pdf] - 1591945
Status of IGEX dark matter search at Canfranc Underground Laboratory
Comments: 6 pages, 3 figures, talk given at 4th International Workshop on the Identification of Dark Matter, York, September 2002
Submitted: 2002-11-25
One IGEX 76Ge double-beta decay detector is currently operating in the Canfranc Underground Laboratory in a search for dark matter WIMPs, through the Ge nuclear recoil produced by the WIMP elastic scattering. In this talk we report on the on-going efforts to understand and eventually reject the background at low energy. These efforts have led to the improvement of the neutron shielding and to partial reduction of the background, but still the remaining events are not totally identified. A tritium contamination or muon-induced neutrons are considered as possible sources, simulations and experimental test being still under progress. According to the success of this study we comment the prospects of the experiment as well as those of its future extension, the GEDEON dark matter experiment.
[10]  oai:arXiv.org:astro-ph/0112272  [pdf] - 1232796
The ROSEBUD experiment at Canfranc: 2001 report
Comments: 3 pages, 6 figures, Proceedings of the TAUP2001 Workshop. Submitted to Nucl. Phys. B (Proc. Suppl) Related information can be found on http://www.unizar.es/lfnae/
Submitted: 2001-12-12, last modified: 2002-01-03
The ROSEBUD experiment for Direct Dark Matter detection settled in 1999 in the Canfranc Underground Laboratory. The first phase of the experiment was dedicated to the understanding and reduction of the radioactive background following successive removals of the radioimpure materials. Sapphire (25g, 50g) and germanium (67g) absorbers were used. Thresholds respectively lower than 1keV and 450 eV were achieved on these detectors. The second phase of the experiment plans to use scintillating bolometers to discriminate between recoiling nuclei and electrons. Prototypes using commercial CaWO4 (54g) and BGO (46g) were designed for this purpose. While internal contamination was found and identified in both targets, neutron calibrations revealed their high discrimination power. A 6 keV threshold on the heat channel of the BGO bolometer points out the interest of such a novel material, for Dark Matter research on neutralinos having spin-dependent or spin-independent interactions.
[11]  oai:arXiv.org:hep-ex/0101037  [pdf] - 113338
Particle Dark Matter and Solar Axion Searches with a small germanium detector at the Canfranc Underground Laboratory
Comments: LaTeX, 11 pages, 4 figures, submitted to Astropart. Phys
Submitted: 2001-01-22
A small, natural abundance, germanium detector (COSME) has been operating recently at the Canfranc Underground Laboratory (Spanish Pyrenees) in improved conditions of shielding and overburden with respect to a previous operation of the same detector. An exposure of 72.7 kg day in these conditions has at present a background improvement of about one order of magnitude compared to the former operation of the detector. These new data have been applied to a direct search for WIMPs and solar axions. New WIMP exclusion plots improving the current bounds for low masses are reported. The paper also presents a limit on the axion-photon coupling obtained from the analysis of the data looking for a Primakoff axion-to-photon conversion and Bragg scattering inside the crystal.
[12]  oai:arXiv.org:hep-ph/0011318  [pdf] - 1507915
Recent results from the canfranc dark matter search with germanium detectors
Comments: 6 pages, talk given at IDM2000, York, September 2000
Submitted: 2000-11-27
Two germanium detectors are currently operating in the Canfranc Underground Laboratory at 2450 m.w.e looking for WIMP dark matter. One is a 2 kg 76Ge IGEX detector (RG-2) which has an energy threshold of 4 keV and a low-energy background rate of about 0.3 c/keV/kg/day. The other is a small (234 g) natural abundance Ge detector (COSME), of low energy threshold (2.5 keV) and an energy resolution of 0.4 keV at 10 keV which is looking for WIMPs and for solar axions. The analysis of 73 kg-days of data taken by COSME in a search for solar axions via their photon Primakoff conversion and Bragg scattering in the Ge crystal yields a 95% C.L. limit for the axion-photon coupling g < 2.8 10^-9 GeV^-1. These data, analyzed for WIMP searches provide an exclusion plot for WIMP-nucleon spin-independent interaction which improves previous plots in the low mass region. On the other hand, the exclusion plot derived from the 60 kg-days of data from the RG-2 IGEX detector improves the exclusion limits derived from other ionization (non thermal) germanium detector experiments in the region of WIMP masses from 30 to 100 GeV recently singled out by the reported DAMA annual modulation effect.
[13]  oai:arXiv.org:astro-ph/0004292  [pdf] - 362880
First results of the ROSEBUD Dark Matter experiment
Comments: 14 pages, 8 figures, submitted to Astroparticle Physics
Submitted: 2000-04-20
Rare Objects SEarch with Bolometers UndergrounD) is an experiment which attempts to detect low mass Weak Interacting Massive Particles (WIMPs) through their elastic scattering off Al and O nuclei. It consists of three small sapphire bolometers (of a total mass of 100 g) with NTD-Ge sensors in a dilution refrigerator operating at 20 mK in the Canfranc Underground Laboratory. We report in this paper the results of several runs (of about 10 days each) with successively improved energy thresholds, and the progressive background reduction obtained by improvement of the radiopurity of the components and subsequent modifications in the experimental assembly, including the addition of old lead shields. Mid-term plans and perspectives of the experiment are also presented.
[14]  oai:arXiv.org:hep-ex/0002053  [pdf] - 113328
New constraints on WIMPs from the Canfranc IGEX dark matter search
Comments: 7 pages, 2 figures, submitted to Physics Letters
Submitted: 2000-02-21
The IGEX Collaboration enriched 76Ge double-beta decay detectors are currently operating in the Canfranc Underground Laboratory with an overburden of 2450 m.w.e. A recent upgrade has made it possible to use them in a search for WIMPs. A new exclusion plot has been derived for WIMP-nucleon spin-independent interaction. To obtain this result, 30 days of data from one IGEX detector, which has an energy threshold of ~4 keV, have been considered. These data improve the exclusion limits derived from other germanium diode experiments in the ~50 GeV DAMA region, and show that with a moderate improvement of the background below 10 keV, the DAMA region may be tested with an additional 1 kg-year of exposure.
[15]  oai:arXiv.org:hep-ph/9912522  [pdf] - 116658
Sensitivity plots for WIMP modulation searches
Comments: 3 pages, 2 figures, talk given at TAUP'99, september 1999
Submitted: 1999-12-28
Prospects of WIMP searches using the annual modulation signature are discussed on statistical grounds, introducing sensitivity plots for the WIMP-nucleon scalar cross section.
[16]  oai:arXiv.org:astro-ph/9912491  [pdf] - 110154
Prospects for solar axions searches with crystals via Bragg scattering
Comments: 3 pages, 2 figures, talk given at TAUP'99, Paris, september 1999
Submitted: 1999-12-23
A calculation of the expected signal due to Primakov coherent conversion of solar axions into photons via Bragg scattering in several solid-state detectors is presented and compared with present and future experimental sensitivities. The axion window m_a > 0.03 eV (not accessible at present by other techniques) could be explored in the foreseeable future with crystal detectors to constrain the axion-photon coupling constant below the latest bounds coming from helioseismology. On the contrary a positive signal in the sensitivity region of such devices would imply revisiting other more stringent astrophysical limits derived for the same range of the axion mass. The application of this technique to the COSME germanium detector which is taking data at the Canfranc Underground Laboratory leads to a 95% C.L. limit g_a < 2.8 10^-9 GeV^-1.
[17]  oai:arXiv.org:hep-ph/9912394  [pdf] - 899146
Sensitivity plots for WIMP direct detection using the annual modulation signature
Comments: 24 pages, ReVTeX, 9 figures, submitted to Astroparticle Physics
Submitted: 1999-12-17
Annual modulation due to the Earth's motion around the Sun is a well known signature of the expected WIMP signal induced in a solid state underground detector. In the present letter we discuss the prospects of this technique on statistical grounds, introducing annual-modulation sensitivity plots for the WIMP-nucleon scalar cross section for different materials and experimental conditions. The highest sensitivity to modulation is found in the WIMP mass interval 10 GeV< m_W < 130 GeV, the actual upper limit depending from the choice of the astrophysical parameters, while the lowest values of the explorable WIMP-nucleon elastic cross-sections fall in most cases within one order of magnitude of the sensitivities of present direct detection WIMP searches.
[18]  oai:arXiv.org:astro-ph/9811359  [pdf] - 103985
Prospects of solar axion searches with crystal detectors
Comments: 12 pages, ReVTeX, 2 figures (included as PS files), submitted to Astroparticle Physics
Submitted: 1998-11-23
A calculation of the expected signal due to Primakoff coherent conversion of solar axions into photons via Bragg scattering in several crystal detectors is presented. The results are confronted with the experimental sensitivities of present and future experiments concluding that the sensitivity of crystal detectors does not challenge the globular cluster limit on the axion-photon coupling g_a. In particular, in the axion mass window m_a ~> 0.03 eV explored with this technique (not accessible at present by other methods) g_a might be constrained down to 10^-9 GeV^-1 (the recent helioseismological bound) provided that significant improvements in the parameters and performances of these detectors be achieved and large statistics accumulated. This bound should be considered as a minimal goal for the sensitivity of future crystal experiments. Consequently, finding a positive signal at this level of sensitivity would necessarily imply revisiting other more stringent astrophysical limits derived for the same range of m_a values.
[19]  oai:arXiv.org:astro-ph/9810308  [pdf] - 103424
Theoretical expectations and experimental prospects for solar axions searches with crystal detectors
Comments: 8 pages, 1 figure, To be published in the proceedings of the 2nd International Workshop on the Identification of Dark Matter (IDM98), Buxton, England, 7-11 September 1998
Submitted: 1998-10-20
A calculation of the expected signal due to Primakov coherent conversion of solar axions into photons via Bragg scattering in several solid--state detectors is presented and compared with present and future experimental sensitivities. The axion window m_a>~0.03 eV (not accessible at present by other techniques) could be explored in the foreseeable future with crystal detectors to constrain the axion--photon coupling constant below the latest bounds coming from helioseismology. On the contrary a positive signal in the sensitivity region of such devices would imply revisiting other more stringent astrophysical limits derived for the same range of the axion mass.
[20]  oai:arXiv.org:astro-ph/9809018  [pdf] - 102722
Search for an annual modulation of dark-matter signals with a germanium spectrometer at the Sierra Grande Laboratory
Comments: New version accepted by Astroparticle Physics. Changes suggested by the referee about the theoretical prediction of rates are included. Conclusions remain unaffected. 14 pages, LaTeX, 7 figures. Uses epsfig macro
Submitted: 1998-09-02, last modified: 1998-09-14
Data collected during three years with a germanium spectrometer at the Sierra Grande underground laboratory have been analyzed for distinctive features of annual modulation of the signal induced by WIMP dark matter candidates. The main motivation for this analysis was the recent suggestion by the DAMA/NaI Collaboration that a yearly modulation signal could not be rejected at the 90% confidence level when analyzing data obtained with a high-mass low-background scintillator detector. We performed two different analyses of the data: First, the statistical distribution of modulation-significance variables (expected from an experiment running under the conditions of Sierra Grande) was compared with the same variables obtained from the data. Second, the data were analyzed in energy bins as an independent check of the first result and to allow for the possibility of a crossover in the expected signal. In both cases no statistically significant deviation from the null result was found, which could support the hypothesis that the data contain a modulated component. A plot is also presented to enable the comparison of these results to those of the DAMA collaboration.
[21]  oai:arXiv.org:astro-ph/9708008  [pdf] - 98186
Experimental Search for Solar Axions via Coherent Primakoff Conversion in a Germanium Spectrometer
Comments: RevTeX, 11 pages, figures can be obtained by fax from Juan.Collar@cern.ch. Submitted to Phys. Lett. B
Submitted: 1997-08-01
Results are reported of an experimental search for the unique, rapidly varying temporal pattern of solar axions coherently converting into photons via the Primakoff effect in a single crystal germanium detector. This conversion is predicted when axions are incident at a Bragg angle with a crystalline plane. The analysis of approximately 1.94 kg.yr of data from the 1 kg DEMOS detector in Sierra Grande, Argentina, yields a new laboratory bound on axion-photon coupling of $g_{a\gamma \gamma} < 2.7\cdot 10^{-9}$ GeV$^{-1}$, independent of axion mass up to ~ 1 keV.