oai:arXiv.org:1004.2595 [pdf] - 1026328
Planck pre-launch status: High Frequency Instrument polarization
calibration
Rosset, C.;
Tristram, M.;
Ponthieu, N.;
Ade, P.;
Catalano, A.;
Conversi, L.;
Couchot, F.;
Crill, B. P.;
Désert, F. -X.;
Ganga, K.;
Giard, M.;
Giraud-Héraud, Y.;
Haïssinski, J.;
Henrot-Versillé, S.;
Holmes, W.;
Jones, W. C.;
Lamarre, J. -M.;
Lange, A.;
Leroy, C.;
Macías-Pérez, J.;
Maffei, B.;
de Marcillac, P.;
Miville-Deschênes, M. -A.;
Montier, L.;
Noviello, F.;
Pajot, F.;
Perdereau, O.;
Piacentini, F.;
Piat, M.;
Plaszczynski, S.;
Pointecouteau, E.;
Puget, J. -L.;
Ristorcelli, I.;
Savini, G.;
Sudiwala, R.;
Veneziani, M.;
Yvon, D.
Submitted: 2010-04-15
The High Frequency Instrument of Planck will map the entire sky in the
millimeter and sub-millimeter domain from 100 to 857 GHz with unprecedented
sensitivity to polarization ($\Delta P/T_{\tiny cmb} \sim 4\cdot 10^{-6}$) at
100, 143, 217 and 353 GHz. It will lead to major improvements in our
understanding of the Cosmic Microwave Background anisotropies and polarized
foreground signals. Planck will make high resolution measurements of the
$E$-mode spectrum (up to $\ell \sim 1500$) and will also play a prominent role
in the search for the faint imprint of primordial gravitational waves on the
CMB polarization. This paper addresses the effects of calibration of both
temperature (gain) and polarization (polarization efficiency and detector
orientation) on polarization measurements. The specific requirements on the
polarization parameters of the instrument are set and we report on their
pre-flight measurement on HFI bolometers. We present a semi-analytical method
that exactly accounts for the scanning strategy of the instrument as well as
the combination of different detectors. We use this method to propagate errors
through to the CMB angular power spectra in the particular case of Planck-HFI,
and to derive constraints on polarization parameters. We show that in order to
limit the systematic error to 10% of the cosmic variance of the $E$-mode power
spectrum, uncertainties in gain, polarization efficiency and detector
orientation must be below 0.15%, 0.3% and 1\deg\ respectively. Pre-launch
ground measurements reported in this paper already fulfill these requirements.
[2]
oai:arXiv.org:astro-ph/0112272 [pdf] - 1232796
The ROSEBUD experiment at Canfranc: 2001 report
Cebrian, S.;
Coron, N.;
Dambier, G.;
Garcia, E.;
Irastorza, I. G.;
Leblanc, J.;
de Marcillac, P.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Sarsa, M. L.;
Villar, J. A.
Submitted: 2001-12-12, last modified: 2002-01-03
The ROSEBUD experiment for Direct Dark Matter detection settled in 1999 in
the Canfranc Underground Laboratory. The first phase of the experiment was
dedicated to the understanding and reduction of the radioactive background
following successive removals of the radioimpure materials. Sapphire (25g, 50g)
and germanium (67g) absorbers were used. Thresholds respectively lower than
1keV and 450 eV were achieved on these detectors. The second phase of the
experiment plans to use scintillating bolometers to discriminate between
recoiling nuclei and electrons. Prototypes using commercial CaWO4 (54g) and BGO
(46g) were designed for this purpose. While internal contamination was found
and identified in both targets, neutron calibrations revealed their high
discrimination power. A 6 keV threshold on the heat channel of the BGO
bolometer points out the interest of such a novel material, for Dark Matter
research on neutralinos having spin-dependent or spin-independent interactions.
[3]
oai:arXiv.org:astro-ph/0004292 [pdf] - 362880
First results of the ROSEBUD Dark Matter experiment
Cebrian, S.;
Coron, N.;
Dambier, G.;
Garcia, E.;
Gonzalez, D.;
Irastorza, I. G.;
Leblanc, J.;
de Marcillac, P.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Peruzzi, A.;
Puimedon, J.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 2000-04-20
Rare Objects SEarch with Bolometers UndergrounD) is an experiment which
attempts to detect low mass Weak Interacting Massive Particles (WIMPs) through
their elastic scattering off Al and O nuclei. It consists of three small
sapphire bolometers (of a total mass of 100 g) with NTD-Ge sensors in a
dilution refrigerator operating at 20 mK in the Canfranc Underground
Laboratory. We report in this paper the results of several runs (of about 10
days each) with successively improved energy thresholds, and the progressive
background reduction obtained by improvement of the radiopurity of the
components and subsequent modifications in the experimental assembly, including
the addition of old lead shields. Mid-term plans and perspectives of the
experiment are also presented.
[4]
oai:arXiv.org:astro-ph/9912385 [pdf] - 110048
Calibration and First light of the Diabolo photometer at the Millimetre
and Infrared Testa Grigia Observatory
Benoit, A.;
Zagury, F.;
Coron, N.;
De Petris, M.;
Desert, F. -X.;
Giard, M.;
Bernard, J. -P.;
Crussaire, J. -P.;
Dambier, G.;
de Bernardis, P.;
Delabrouille, J.;
De Luca, A.;
de Marcillac, P.;
Jegoudez, G.;
Lamarre, J. -M.;
Leblanc, J.;
Lepeltier, J. -P.;
Leriche, B.;
Mainella, G.;
Narbonne, J.;
Pajot, F.;
Pons, R.;
Puget, J. -L.;
Pujol, S.;
Recouvreur, G.;
Serra, G.;
Soglasnova, V.;
Torre, J. -P.;
Vozzi, B.
Submitted: 1999-12-17
We have designed and built a large-throughput dual channel photometer,
Diabolo. This photometer is dedicated to the observation of millimetre
continuum diffuse sources, and in particular, of the Sunyaev-Zel'dovich effect
and of anisotropies of the 3K background. We describe the optical layout and
filtering system of the instrument, which uses two bolometric detectors for
simultaneous observations in two frequency channels at 1.2 and 2.1 mm. The
bolometers are cooled to a working temperature of 0.1 K provided by a compact
dilution cryostat. The photometric and angular responses of the instrument are
measured in the laboratory. First astronomical light was detected in March 1995
at the focus of the new Millimetre and Infrared Testa Grigia Observatory (MITO)
Telescope. The established sensitivity of the system is of 7 mK_RJ s^1/2$. For
a typical map of at least 10 beams, with one hour of integration per beam, one
can achieve the rms values of y_SZ ~ 7 10^-5 and the 3K background anisotropy
Delta T/T ~ 7 10^-5, in winter conditions. We also report on a novel bolometer
AC readout circuit which allows for the first time total power measurements on
the sky. This technique alleviates (but does not forbid) the use of chopping
with a secondary mirror. This technique and the dilution fridge concept will be
used in future scan--modulated space instrument like the ESA Planck mission
project.
[5]
oai:arXiv.org:astro-ph/9808270 [pdf] - 102614
Observations of the Sunyaev-Zel'dovich effect at high angular resolution
towards the galaxy clusters A665, A2163 and CL0016+16
Desert, F. -X.;
Benoit, A.;
Gaertner, S.;
Bernard, J. -P.;
Coron, N.;
Delabrouille, J.;
de Marcillac, P.;
Giard, M.;
Lamarre, J. -M.;
Lefloch, B.;
Puget, J. -L.;
Sirbi, A.
Submitted: 1998-08-24
We report on the first observation of the Sunyaev-Zel'dovich effect with the
Diabolo experiment at the IRAM 30 metre telescope. A significant brightness
decrement is detected in the direction of three clusters (Abell 665, Abell 2163
and CL0016+16). With a 30 arcsecond beam and 3 arcminute beamthrow, this is the
highest angular resolution observation to date of the SZ effect.