Normalized to: De la Roche, D.
[1]
oai:arXiv.org:1911.04814 [pdf] - 1998101
New constraints on the HR 8799 planetary system from mid-infrared direct
imaging
Submitted: 2019-11-12, last modified: 2019-11-13
Direct imaging is a tried and tested method of detecting exoplanets in the
near infrared, but has so far not been extended to longer wavelengths. New data
at mid-IR wavelengths (8-20{\mu}m) canprovide additional constraints on
planetary atmospheric models. We use the VISIR instrumenton the VLT to detect
or set stringent limits on the 8.7{\mu}m flux of the four planets surrounding
HR8799, and to search for additional companions. We use a novel circularised
PSF subtractiontechnique to reduce the stellar signal and obtain instrument
limited background levels andobtain optimal flux limits. The BT SETTL
isochrones are then used to determine the resultingmass limits. We find flux
limits between 0.7 and 3.3 mJy for the J8.9 flux of the differentplanets at
better than5{\sigma}level and derive a new mass limit of 30 MJupfor any objects
beyond40 AU. While this work has not detected planets in the HR 8799 system at
8.7{\mu}m, it has foundthat an instrument with the sensitivity of VISIR is
sufficient to detect at least 4 known hotplanets around close stars,
including\b{eta}Pictoris b (1700 K, 19 pc), with more than5{\sigma}certaintyin
10 hours of observing time in the mid-IR.
[2]
oai:arXiv.org:1808.10790 [pdf] - 1742208
Molecule mapping of HR8799b using OSIRIS on Keck: Strong detection of
water and carbon monoxide, but no methane
Submitted: 2018-08-31
Context. In 2015, Barman et al. (ApJ, 804, 61) presented detections of
absorption from water, carbon monoxide, and methane in the atmosphere of the
directly imaged exoplanet HR8799b using integral field spectroscopy (IFS) with
OSIRIS on the Keck II telescope. We recently devised a new method to analyse
IFU data, called molecule mapping, searching for high-frequency signatures of
particular molecules in an IFU data cube.
Aims. The aim of this paper is to use the molecule mapping technique to
search for the previously detected spectral signatures in HR8799b using the
same data, allowing a comparison of molecule mapping with previous methods.
Methods. The medium-resolution H- and K-band pipeline-reduced archival data
were retrieved from the Keck archive facility. Telluric and stellar lines were
removed from each spectrum in the data cube, after which the residuals were
cross-correlated with model spectra of carbon monoxide, water, and methane.
Results. Both carbon monoxide and water are clearly detected at high
signal-to-noise, however, methane is not retrieved.
Conclusions. Molecule mapping works very well on the OSIRIS data of exoplanet
HR8799b. However, it is not evident why methane is detected in the original
analysis, but not with the molecule mapping technique. Possible causes could be
the presence of telluric residuals, different spectral filtering techniques, or
the use of different methane models. We do note that in the original analysis
methane was only detected in the K-band, while the H-band methane signal could
be expected to be comparably strong. More sensitive observations with the JWST
will be capable of confirming or disproving the presence of methane in this
planet at high confidence.