Normalized to: De Geronimo, G.
[1]
oai:arXiv.org:1701.04536 [pdf] - 1534638
Design of the telescope truss and gondola for the balloon-borne X-ray
polarimeter X-Calibur
Kislat, Fabian;
Beheshtipour, Banafsheh;
Dowkontt, Paul;
Guarino, Victor;
Lanzi, R. James;
Okajima, Takashi;
Braun, Dana;
Cannon, Scott;
De Geronimo, Gialuigi;
Heatwole, Scott;
Hoorman, Janie;
Li, Shaorui;
Mori, Hideyuki;
Shreves, Christopher M.;
Stuchlik, David;
Krawczynski, Henric
Submitted: 2017-01-17
X-ray polarimetry has seen a growing interest in recent years. Improvements
in detector technology and focusing X-ray optics now enable sensitive
astrophysical X-ray polarization measurements. These measurements will provide
new insights into the processes at work in accreting black holes, the emission
of X-rays from neutron stars and magnetars, and the structure of AGN jets.
X-Calibur is a balloon-borne hard X-ray scattering polarimeter. An X-ray mirror
with a focal length of 8 m focuses X-rays onto the detector, which consists of
a plastic scattering element surrounded by Cadmium-Zinc-Telluride detectors,
which absorb and record the scattered X-rays. Since X-rays preferentially
scatter perpendicular to their polarization direction, the polarization
properties of an X-ray beam can be inferred from the azimuthal distribution of
scattered X-rays. A close alignment of the X-ray focal spot with the center of
the detector is required in order to reduce systematic uncertainties and to
maintain a high photon detection efficiency. This places stringent requirements
on the mechanical and thermal stability of the telescope structure. During the
flight on a stratospheric balloon, X-Calibur makes use of the Wallops
Arc-Second Pointer (WASP) to point the telescope at astrophysical sources. In
this paper, we describe the design, construction, and test of the telescope
structure, as well as its performance during a 25-hour flight from Ft. Sumner,
New Mexico. The carbon fiber-aluminum composite structure met the requirements
set by X-Calibur and its design can easily be adapted for other types of
experiments, such as X-ray imaging or spectroscopic telescopes.
[2]
oai:arXiv.org:1501.03433 [pdf] - 921585
Optimization of <= 200 um pitch CZT detectors for future high-resolution
X-ray instrumentation in astrophysics
Submitted: 2015-01-14
Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of
choice for the detection of X-rays in the X-ray energy band E >= 5keV with
excellent spatial and spectral resolution and without cryogenic cooling. Owing
to recent breakthroughs in grazing incidence mirror technology, next-generation
hard X-ray telescopes will achieve angular resolution between 5 and 10 arc
seconds - about an order of magnitude better than that of the NuSTAR hard X-ray
telescope. As a consequence, the next generation of X-ray telescopes will
require pixelated X-ray detectors with pixels on a grid with a lattice constant
of <= 250um. Additional detector requirements include a low energy threshold of
less than 5keV and an energy resolution of less than one keV. The science
drivers for a high angular-resolution X-ray mission include studies and
measurements of black hole spins, the cosmic evolution of super-massive black
holes, active galactic nuclei feedback, and the behaviour of matter at very
high densities. In this contribution, we report on our R&D studies with the
goal to optimise small-pixel Cadmium Zinc Telluride and Cadmium Telluride
detectors.
[3]
oai:arXiv.org:1412.6457 [pdf] - 911181
Design and Performance of the X-ray polarimeter X-Calibur
Beilicke, Matthias;
Kislat, F.;
Zajczyk, A.;
Guo, Q.;
Endsley, R.;
Stork, M.;
Cowsik, R.;
Dowkontt, P.;
Barthelmy, S.;
Hams, T.;
Okajima, T.;
Sasaki, M.;
Zeiger, B.;
De Geronimo, G.;
Baring, M. G.;
Krawczynski, H.
Submitted: 2014-12-19
X-ray polarimetry promises to give qualitatively new information about
high-energy astrophysical sources, such as binary black hole systems,
micro-quasars, active galactic nuclei, neutron stars, and gamma-ray bursts. We
designed, built and tested a X-ray polarimeter, X-Calibur, to be used in the
focal plane of the balloon-borne InFOCuS grazing incidence X-ray telescope.
X-Calibur combines a low-Z scatterer with a CZT detector assembly to measure
the polarization of 20-80keV X-rays making use of the fact that polarized
photons scatter preferentially perpendicular to the electric field orientation.
X-Calibur achieves a high detection efficiency of ~80%. The X-Calibur detector
assembly is completed, tested, and fully calibrated. The response to a
polarized X-ray beam was measured successfully at the Cornell High Energy
Synchrotron Source. This paper describes the design, calibration and
performance of the X-Calibur polarimeter. In principle, a similar space-borne
scattering polarimeter could operate over the broader 2-100keV energy band.
[4]
oai:arXiv.org:1102.1514 [pdf] - 302116
Study of Thick CZT Detectors for X-ray and Gamma-Ray Astronomy
Li, Qiang;
Beilicke, M.;
Lee, Kuen;
Garson, Alfred;
Guo, Q.;
Martin, Jerrad;
Yin, Y.;
Dowkontt, P.;
De Geronimo, G.;
Jung, I.;
Krawczynski, H.
Submitted: 2011-02-08
CdZnTe (CZT) is a wide bandgap II-VI semiconductor developed for the
spectroscopic detection of X-rays and {\gamma}-rays at room temperature. The
Swift Burst Alert Telescope is using an 5240 cm2 array of 2 mm thick CZT
detectors for the detection of 15-150 keV X-rays from Gamma-Ray Bursts. We
report on the systematic tests of thicker (\geq 0.5 cm) CZT detectors with
volumes between 2 cm3 and 4 cm3 which are potential detector choices for a
number of future X-ray telescopes that operate in the 10 keV to a few MeV
energy range. The detectors contacted in our laboratory achieve Full Width Half
Maximum energy resolutions of 2.7 keV (4.5%) at 59 keV, 3 keV (2.5%) at 122 keV
and 4 keV (0.6%) at 662 keV. The 59 keV and 122 keV energy resolutions are
among the world-best results for \geq 0.5 cm thick CZT detectors. We use the
data set to study trends of how the energy resolution depends on the detector
thickness and on the pixel pitch. Unfortunately, we do not find clear trends,
indicating that even for the extremely good energy resolutions reported here,
the achievable energy resolutions are largely determined by the properties of
individual crystals. Somewhat surprisingly, we achieve the reported results
without applying a correction of the anode signals for the depth of the
interaction. Measuring the interaction depths thus does not seem to be a
pre-requisite for achieving sub-1% energy resolutions at 662 keV.
[5]
oai:arXiv.org:1007.0988 [pdf] - 1033531
AXTAR: Mission Design Concept
Ray, Paul S.;
Chakrabarty, Deepto;
Wilson-Hodge, Colleen A.;
Phlips, Bernard F.;
Remillard, Ronald A.;
Levine, Alan M.;
Wood, Kent S.;
Wolff, Michael T.;
Gwon, Chul S.;
Strohmayer, Tod E.;
Baysinger, Michael;
Briggs, Michael S.;
Capizzo, Peter;
Fabisinski, Leo;
Hopkins, Randall C.;
Hornsby, Linda S.;
Johnson, Les;
Maples, C. Dauphne;
Miernik, Janie H.;
Thomas, Dan;
De Geronimo, Gianluigi
Submitted: 2010-07-06
The Advanced X-ray Timing Array (AXTAR) is a mission concept for X-ray timing
of compact objects that combines very large collecting area, broadband spectral
coverage, high time resolution, highly flexible scheduling, and an ability to
respond promptly to time-critical targets of opportunity. It is optimized for
submillisecond timing of bright Galactic X-ray sources in order to study
phenomena at the natural time scales of neutron star surfaces and black hole
event horizons, thus probing the physics of ultradense matter, strongly curved
spacetimes, and intense magnetic fields. AXTAR's main instrument, the Large
Area Timing Array (LATA) is a collimated instrument with 2-50 keV coverage and
over 3 square meters effective area. The LATA is made up of an array of
supermodules that house 2-mm thick silicon pixel detectors. AXTAR will provide
a significant improvement in effective area (a factor of 7 at 4 keV and a
factor of 36 at 30 keV) over the RXTE PCA. AXTAR will also carry a sensitive
Sky Monitor (SM) that acts as a trigger for pointed observations of X-ray
transients in addition to providing high duty cycle monitoring of the X-ray
sky. We review the science goals and technical concept for AXTAR and present
results from a preliminary mission design study.
[6]
oai:arXiv.org:0812.1809 [pdf] - 177276
HX-POL - A Balloon-Borne Hard X-Ray Polarimeter
Krawczynski, H.;
Garson, A.;
Li, Q.;
Beilicke, M.;
Dowkontt, P.;
Wulf, E.;
Kurfess, J.;
Novikova, E.;
De Geronimo, G.;
Baring, M. G.;
Harding, A. K.;
Grindlay, J.;
Hong, J. S.
Submitted: 2008-12-09, last modified: 2010-06-03
We report on the design and estimated performance of a balloon-borne hard
X-ray polarimeter called HX-POL. The experiment uses a combination of Si and
Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV
X-rays from cosmic sources through the dependence of the angular distribution
of Compton scattered photons on the polarization direction. On a one-day
balloon flight, HX-POL would allow us to measure the polarization of bright
Crab-like sources for polarization degrees well below 10%. On a longer (15-30
day) flight from Australia or Antarctica, HX-POL would be be able to measure
the polarization of bright galactic X-ray sources down to polarization degrees
of a few percent. Hard X-ray polarization measurements provide unique venues
for the study of particle acceleration processes by compact objects and
relativistic outflows. In this paper, we discuss the overall instrument design
and performance. Furthermore, we present results from laboratory tests of the
Si and CZT detectors.
[7]
oai:arXiv.org:0811.3201 [pdf] - 18703
Fabrication and Test of Pixelated CZT Detectors with Different Pixel
Pitches and Thicknesses
Li, Q.;
Garson, A.;
Dowkontt, P.;
Martin, J.;
Beilicke, M.;
Jung, I.;
Groza, M.;
Burger, A.;
De Geronimo, G.;
Krawczynski, H.;
.;
.;
.;
.
Submitted: 2008-11-19
The main methods grown Cadmium Zinc Telluride (CZT) crystals with high yield
and excellent homogeneity are Modified Horizontal Bridgman (MHB) and High
Pressure Bridgman (HPB) processes, respectively. In this contribution, the
readout system based on two 32-channel NCI-ASICs for pixellated CZT detector
arrays has been developed and tested. The CZT detectors supplied by Orbotech
(MHB) and eV products (HPB) are tested by NCI-ASIC readout system. The CZT
detectors have an array of 8x8 or 11x11 pixel anodes fabricated on the anode
surface with the area up to 2 cm x2 cm and the thickness of CZT detectors
ranges from 0.5 cm to 1 cm. Energy spectra resolution and electron
mobility-lifetime products of 8x8 pixels CZT detector with different
thicknesses have been investigated.