oai:arXiv.org:2001.08106 [pdf] - 2080977
Design and construction of a new detector to measure ultra-low
radioactive-isotope contamination of argon
The DarkSide Collaboration;
Aalseth, C. E.;
Abdelhakim, S.;
Acerbi, F.;
Agnes, P.;
Ajaj, R.;
Albuquerque, I. F. M.;
Alexander, T.;
Alici, A.;
Alton, A. K.;
Amaudruz, P.;
Ameli, F.;
Anstey, J.;
Antonioli, P.;
Arba, M.;
Arcelli, S.;
Ardito, R.;
Arnquist, I. J.;
Arpaia, P.;
Asner, D. M.;
Asunskis, A.;
Ave, M.;
Back, H. O.;
Olmedo, A. Barrado;
Batignani, G.;
Bisogni, M. G.;
Bocci, V.;
Bondar, A.;
Bonfini, G.;
Bonivento, W.;
Borisova, E.;
Bottino, B.;
Boulay, M. G.;
Bunker, R.;
Bussino, S.;
Buzulutskov, A.;
Cadeddu, M.;
Cadoni, M.;
Caminata, A.;
Canci, N.;
Candela, A.;
Cantini, C.;
Caravati, M.;
Cariello, M.;
Carnesecchi, F.;
Carpinelli, M.;
Castellani, A.;
Castello, P.;
Catalanotti, S.;
Cataudella, V.;
Cavalcante, P.;
Cavazza, D.;
Cavuoti, S.;
Cebrian, S.;
Ruiz, J. M. Cela;
Celano, B.;
Cereseto, R.;
Cheng, W.;
Chepurnov, A.;
Cicalò, C.;
Cifarelli, L.;
Citterio, M.;
Cocco, A. G.;
Cocco, V.;
Colocci, M.;
Consiglio, L.;
Cossio, F.;
Covone, G.;
Crivelli, P.;
D'Antone, I.;
D'Incecco, M.;
D'Urso, D.;
Rolo, M. D. Da Rocha;
Dadoun, O.;
Daniel, M.;
Davini, S.;
De Candia, A.;
De Cecco, S.;
De Deo, M.;
De Falco, A.;
De Filippis, G.;
De Gruttola, D.;
De Guido, G.;
De Rosa, G.;
Dellacasa, G.;
Demontis, P.;
DePaquale, S.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Noto, L.;
Di Pietro, G.;
Di Stefano, P.;
Dionisi, C.;
Dolganov, G.;
Dordei, F.;
Downing, M.;
Edalatfar, F.;
Empl, A.;
Diaz, M. Fernandez;
Ferri, A.;
Filip, C.;
Fiorillo, G.;
Fomenko, K.;
Franceschi, A.;
Franco, D.;
Froudakis, G. E.;
Gabriele, F.;
Gabrieli, A.;
Galbiati, C.;
Abia, P. Garcia;
Fora, D. Gascón;
Gendotti, A.;
Ghiano, C.;
Ghisi, A.;
Giagu, S.;
Giampa, P.;
Giampaolo, R. A.;
Giganti, C.;
Giorgi, M. A.;
Giovanetti, G. K.;
Gligan, M. L.;
Gola, A.;
Gorchakov, O.;
Grab, M.;
Diaz, R. Graciani;
Granato, F.;
Grassi, M.;
Grate, J. W.;
Grigoriev, G. Y.;
Grobov, A.;
Gromov, M.;
Guan, M.;
Guerra, M. B. B.;
Guerzoni, M.;
Gulino, M.;
Haaland, R. K.;
Hackett, B. R.;
Hallin, A.;
Harrop, B.;
Hoppe, E. W.;
Horikawa, S.;
Hosseini, B.;
Hubaut, F.;
Humble, P.;
Hungerford, E. V.;
Ianni, An.;
Ilyasov, A.;
Ippolito, V.;
Jillings, C.;
Keeter, K.;
Kendziora, C. L.;
Kim, S.;
Kochanek, I.;
Kondo, K.;
Kopp, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kugathasan, R.;
Kuss, M.;
Kuźniak, M.;
La Commara, M.;
La Delfa, L.;
Lai, M.;
Langrock, S.;
Lebois, M.;
Lehnert, B.;
Levashko, N.;
Li, X.;
Liqiang, Q.;
Lissia, M.;
Lodi, G. U.;
Longo, G.;
Manzano, R. López;
Lussana, R.;
Luzzi, L.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Mapelli, L.;
Marcante, M.;
Margotti, A.;
Mari, S. M.;
Mariani, M.;
Maricic, J.;
Marinelli, M.;
Marras, D.;
Martínez, M.;
Morales, J. J. Martínez;
Rojas, A. D. Martinez;
Martoff, C. J.;
Mascia, M.;
Mason, J.;
Masoni, A.;
Mazzi, A.;
McDonald, A. B.;
Messina, A.;
Meyers, P. D.;
Miletic, T.;
Milincic, R.;
Moggi, A.;
Moioli, S.;
Monroe, J.;
Morrocchi, M.;
Mroz, T.;
Mu, W.;
Muratova, V. N.;
Murphy, S.;
Muscas, C.;
Musico, P.;
Nania, R.;
Napolitano, T.;
Agasson, A. Navrer;
Nessi, M.;
Nikulin, I.;
Oleinik, A.;
Oleynikov, V.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Palmas, S.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Paternoster, G.;
Pavletcov, V.;
Pazzona, F.;
Peeters, S.;
Pegoraro, P. A.;
Pelczar, K.;
Pellegrini, L. A.;
Pellegrino, C.;
Pelliccia, N.;
Perotti, F.;
Pesudo, V.;
Picciau, E.;
Piemonte, C.;
Pietropaolo, F.;
Pocar, A.;
Pollman, T.;
Portaluppi, D.;
Poudel, S. S.;
Pralavorio, P.;
Price, D.;
Radics, B.;
Raffaelli, F.;
Ragusa, F.;
Razeti, M.;
Razeto, A.;
Regazzoni, V.;
Regenfus, C.;
Renshaw, A. L.;
Rescia, S.;
Rescigno, M.;
Retiere, F.;
Rignanese, L. P.;
Rivetti, A.;
Romani, A.;
Romero, L.;
Rossi, N.;
Rubbia, A.;
Sablone, D.;
Sala, P.;
Salatino, P.;
Samoylov, O.;
García, E. Sánchez;
Sanfilippo, S.;
Sant, M.;
Santone, D.;
Santorelli, R.;
Savarese, C.;
Scapparone, E.;
Schlitzer, B.;
Scioli, G.;
Segreto, E.;
Seifert, A.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Siddhanta, S.;
Simeone, M.;
Singh, P. N.;
Skensved, P.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sobrero, G.;
Sokolov, A.;
Sotnikov, A.;
Stainforth, R.;
Steri, A.;
Stracka, S.;
Strickland, V.;
Suffritti, G. B.;
Sulis, S.;
Suvorov, Y.;
Szelc, A. M.;
Tartaglia, R.;
Testera, G.;
Thorpe, T.;
Tonazzo, A.;
Tosi, A.;
Tuveri, M.;
Unzhakov, E. V.;
Usai, G.;
Vacca, A.;
Vázquez-Jáuregui, E.;
Verducci, M.;
Viant, T.;
Viel, S.;
Villa, F.;
Vishneva, A.;
Vogelaar, R. B.;
Wada, M.;
Wahl, J.;
Walding, J. J.;
Wang, H.;
Wang, Y.;
Westerdale, S.;
Wheadon, R. J.;
Williams, R.;
Wilson, J.;
Wojcik, Marcin;
Wojcik, Mariusz;
Wu, S.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zuffa, M.;
Zuzel, G.
Submitted: 2020-01-22
Large liquid argon detectors offer one of the best avenues for the detection
of galactic weakly interacting massive particles (WIMPs) via their scattering
on atomic nuclei. The liquid argon target allows exquisite discrimination
between nuclear and electron recoil signals via pulse-shape discrimination of
the scintillation signals. Atmospheric argon (AAr), however, has a naturally
occurring radioactive isotope, $^{39}$Ar, a $\beta$ emitter of cosmogenic
origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up
concerns. The use of argon extracted from underground wells, deprived of
$^{39}$Ar, is key to the physics potential of these experiments. The
DarkSide-20k dark matter search experiment will operate a dual-phase time
projection chamber with 50 tonnes of radio-pure underground argon (UAr), that
was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger
than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is
crucial for the success of DarkSide-20k, as well as for future experiments of
the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by
the DArT in ArDM experiment, a small chamber made with extremely radio-pure
materials that will be placed at the centre of the ArDM detector, in the
Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an
active veto for background radioactivity, mostly $\gamma$-rays from the ArDM
detector materials and the surrounding rock. This article describes the DArT in
ArDM project, including the chamber design and construction, and reviews the
background required to achieve the expected performance of the detector.
[2]
oai:arXiv.org:1907.09332 [pdf] - 1998536
Measurement of the ion fraction and mobility of $^{218}$Po produced in
$^{222}$Rn decays in liquid argon
Agnes, P.;
Albuquerque, I. F. M.;
Alexander, T.;
Alton, A. K.;
Ave, M.;
Back, H. O.;
Batignani, G.;
Biery, K.;
Bocci, V.;
Bonfini, G.;
Bonivento, W. M.;
Bottino, B.;
Bussino, S.;
Cadeddu, M.;
Cadoni, M.;
Calaprice, F.;
Caminata, A.;
Canci, N.;
Candela, A.;
Caravati, M.;
Cariello, M.;
Carlini, M.;
Carpinelli, M.;
Catalanotti, S.;
Cataudella, V.;
Cavalcante, P.;
Cavuoti, S.;
Chepurnov, A.;
Cicalo, C.;
Cocco, A. G.;
Covone, G.;
D'Angelo, D.;
Davini, S.;
De Candia, A.;
De Cecco, S.;
De Deo, M.;
De Filippis, G.;
De Rosa, G.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
D'Incecco, M.;
Di Pietro, G.;
Dionisi, C.;
Downing, M.;
D'Urso, D.;
Edkins, E.;
Empl, A.;
Fiorillo, G.;
Fomenko, K.;
Franco, D.;
Gabriele, F.;
Galbiati, C.;
Ghiano, C.;
Giagu, S.;
Giganti, C.;
Giovanetti, G. K.;
Gorchakov, O.;
Goretti, A. M.;
Granato, F.;
Grobov, A.;
Gromov, M.;
Guan, M.;
Guardincerri, Y.;
Gulino, M.;
Hackett, B. R.;
Herner, K.;
Hosseini, B.;
Hughes, D.;
Humble, P.;
Hungerford, E. V.;
Ianni, Al.;
Ianni, An.;
Ippolito, V.;
Johnson, T. N.;
Keeter, K.;
Kendziora, C. L.;
Kochanek, I.;
Koh, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kuss, M.;
La Commara, M.;
Lai, M.;
Li, X.;
Lissia, M.;
Longo, G.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Mapelli, L.;
Mari, S. M.;
Maricic, J.;
Martoff, C. J.;
Messina, A.;
Meyers, P. D.;
Milincic, R.;
Monte, A.;
Morrocchi, M.;
Muratova, V. N.;
Musico, P.;
Agasson, A. Navrer;
Nozdrina, A. O.;
Oleinik, A.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Pelczar, K.;
Pelliccia, N.;
Picciau, E.;
Pocar, A.;
Pordes, S.;
Poudel, S. S.;
Qian, H.;
Ragusa, F.;
Razeti, M.;
Razeto, A.;
Renshaw, A. L.;
Rescigno, M.;
Riffard, Q.;
Romani, A.;
Rossi, B.;
Rossi, N.;
Sablone, D.;
Samoylov, O.;
Sands, W.;
Sanfilippo, S.;
Savarese, C.;
Schlitzer, B.;
Segreto, E.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Singh, P. N.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sotnikov, A.;
Stanford, C.;
Stracka, S.;
Suvorov, Y.;
Tartaglia, R.;
Testera, G.;
Tonazzo, A.;
Trinchese, P.;
Unzhakov, E. V.;
Verducci, M.;
Vishneva, A.;
Vogelaar, R. B.;
Wada, M.;
Waldrop, T. J.;
Wang, H.;
Wang, Y.;
Watson, A. W.;
Westerdale, S.;
Wojcik, M. M.;
Xiang, X.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zhu, C.;
Zuzel, G.
Submitted: 2019-07-22, last modified: 2019-10-28
We report measurements of the charged daughter fraction of $^{218}$Po as a
result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions,
using radon-polonium coincidences from the $^{238}$U chain identified in 532
live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is
charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is
(8.6$\pm$0.1)$\times$10$^{-4}$$\frac{\text{cm}^2}{\text{Vs}}$.
[3]
oai:arXiv.org:1704.03741 [pdf] - 1813965
Directional dark matter detection sensitivity of a two-phase liquid
argon detector
Cadeddu, M.;
Lissia, M.;
Agnes, P.;
Batignani, G.;
Bonivento, W. M.;
Bottino, B.;
Caravati, M.;
Cocco, A.;
Covone, G.;
de Candia, A.;
Catalanotti, S.;
Cataudella, V.;
Cicalo', C.;
De Filippis, G.;
De Rosa, G.;
Davini, S.;
Devoto, A.;
Dionisi, C.;
Franco, D.;
Giganti, C.;
Galbiati, C.;
Giagu, S.;
Gulino, M.;
Kuss, M.;
Lista, L.;
Longo, G.;
Navrer-Agasson, A.;
Pallavicini, M.;
Pandola, L.;
Paoloni, E.;
Picciau, E.;
Razeti, M.;
Rescigno, M.;
Riffard, Q.;
Rossi, B.;
Rossi, N.;
Testera, G.;
Trinchese, P.;
Tonazzo, A.;
Walker, S.;
Fiorillo, G.
Submitted: 2017-04-11, last modified: 2019-01-14
We examine the sensitivity of a large scale two-phase liquid argon detector
to the directionality of the dark matter signal. This study was performed under
the assumption that, above 50 keV of recoil energy, one can determine (with
some resolution) the direction of the recoil nucleus without head-tail
discrimination, as suggested by past studies that proposed to exploit the
dependence of columnar recombination on the angle between the recoil nucleus
direction and the electric field. In this paper we study the differential
interaction recoil rate as a function of the recoil direction angle with
respect to the zenith for a detector located at the Laboratori Nazionali del
Gran Sasso and we determine its diurnal and seasonal modulation. Using a
likelihood-ratio based approach we show that, with the angular information
alone, 100 events are enough to reject the isotropic hypothesis at three
standard deviation level. For an exposure of 100 tonne years this would
correspond to a spin independent WIMP-nucleon cross section of about 10^-46
cm^2 at 200 GeV WIMP mass. The results presented in this paper provide strong
motivation for the experimental determination of directional recoil effects in
two-phase liquid argon detectors.
[4]
oai:arXiv.org:1802.07198 [pdf] - 1789406
DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon
The DarkSide Collaboration;
Agnes, P.;
Albuquerque, I. F. M.;
Alexander, T.;
Alton, A. K.;
Araujo, G. R.;
Ave, M.;
Back, H. O.;
Baldin, B.;
Batignani, G.;
Biery, K.;
Bocci, V.;
Bonfini, G.;
Bonivento, W.;
Bottino, B.;
Budano, F.;
Bussino, S.;
Cadeddu, M.;
Cadoni, M.;
Calaprice, F.;
Caminata, A.;
Canci, N.;
Candela, A.;
Caravati, M.;
Cariello, M.;
Carlini, M.;
Carpinelli, M.;
Catalanotti, S.;
Cataudella, V.;
Cavalcante, P.;
Cavuoti, S.;
Chepurnov, A.;
Cicalò, C.;
Cocco, A. G.;
Covone, G.;
D'Angelo, D.;
D'Incecco, M.;
D'Urso, D.;
Davini, S.;
De Candia, A.;
De Cecco, S.;
De Deo, M.;
De Filippis, G.;
De Rosa, G.;
De Vincenzi, M.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Pietro, G.;
Dionisi, C.;
Downing, M.;
Edkins, E.;
Empl, A.;
Fan, A.;
Fiorillo, G.;
Fitzpatrick, R. S.;
Fomenko, K.;
Franco, D.;
Gabriele, F.;
Galbiati, C.;
Ghiano, C.;
Giagu, S.;
Giganti, C.;
Giovanetti, G. K.;
Gorchakov, O.;
Goretti, A. M.;
Granato, F.;
Gromov, M.;
Guan, M.;
Guardincerri, Y.;
Gulino, M.;
Hackett, B. R.;
Herner, K.;
Hosseini, B.;
Hughes, D.;
Humble, P.;
Hungerford, E. V.;
Ianni, An.;
Ippolito, V.;
James, I.;
Johnson, T. N.;
Keeter, K.;
Kendziora, C. L.;
Kochanek, I.;
Koh, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kuss, M.;
La Commara, M.;
Lai, M.;
Li, X.;
Lissia, M.;
Longo, G.;
Ma, Y.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Mapelli, L.;
Mari, S. M.;
Maricic, J.;
Martoff, C. J.;
Messina, A.;
Meyers, P. D.;
Milincic, R.;
Monte, A.;
Morrocchi, M.;
Mount, B. J.;
Muratova, V. N.;
Musico, P.;
Agasson, A. Navrer;
Nozdrina, A. O.;
Oleinik, A.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Pelczar, K.;
Pelliccia, N.;
Pocar, A.;
Pordes, S.;
Poudel, S. S.;
Pugachev, D. A.;
Qian, H.;
Ragusa, F.;
Razeti, M.;
Razeto, A.;
Reinhold, B.;
Renshaw, A. L.;
Rescigno, M.;
Riffard, Q.;
Romani, A.;
Rossi, B.;
Rossi, N.;
Sablone, D.;
Samoylov, O.;
Sands, W.;
Sanfilippo, S.;
Savarese, C.;
Schlitzer, B.;
Segreto, E.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Singh, P. N.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sotnikov, A.;
Stanford, C.;
Stracka, S.;
Suvorov, Y.;
Tartaglia, R.;
Testera, G.;
Tonazzo, A.;
Trinchese, P.;
Unzhakov, E. V.;
Verducci, M.;
Vishneva, A.;
Vogelaar, B.;
Wada, M.;
Waldrop, T. J.;
Wang, H.;
Wang, Y.;
Watson, A. W.;
Westerdale, S.;
Wojcik, M. M.;
Xiang, X.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zhu, C.;
Zuzel, G.
Submitted: 2018-02-20, last modified: 2018-11-19
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon
time projection chamber operating at Laboratori Nazionali del Gran Sasso. This
paper reports on the blind analysis of a (16,660+-270) kg d exposure using a
target of low-radioactivity argon extracted from underground sources. We find
no events in the dark matter selection box and set a 90% C.L. upper limit on
the dark matter-nucleon spin-independent cross section of 1.14E-44 cm^2
(3.78E-44 cm^2, 3.43E-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2, 10
TeV/c^2).
[6]
oai:arXiv.org:1802.06994 [pdf] - 1739878
Low-Mass Dark Matter Search with the DarkSide-50 Experiment
The DarkSide Collaboration;
Agnes, P.;
Albuquerque, I. F. M.;
Alexander, T.;
Alton, A. K.;
Araujo, G. R.;
Asner, D. M.;
Ave, M.;
Back, H. O.;
Baldin, B.;
Batignani, G.;
Biery, K.;
Bocci, V.;
Bonfini, G.;
Bonivento, W.;
Bottino, B.;
Budano, F.;
Bussino, S.;
Cadeddu, M.;
Cadoni, M.;
Calaprice, F.;
Caminata, A.;
Canci, N.;
Candela, A.;
Caravati, M.;
Cariello, M.;
Carlini, M.;
Carpinelli, M.;
Catalanotti, S.;
Cataudella, V.;
Cavalcante, P.;
Cavuoti, S.;
Cereseto, R.;
Chepurnov, A.;
Cicalò, C.;
Cifarelli, L.;
Cocco, A. G.;
Covone, G.;
D'Angelo, D.;
D'Incecco, M.;
D'Urso, D.;
Davini, S.;
De Candia, A.;
De Cecco, S.;
De Deo, M.;
De Filippis, G.;
De Rosa, G.;
De Vincenzi, M.;
Demontis, P.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Pietro, G.;
Dionisi, C.;
Downing, M.;
Edkins, E.;
Empl, A.;
Fan, A.;
Fiorillo, G.;
Fomenko, K.;
Franco, D.;
Gabriele, F.;
Gabrieli, A.;
Galbiati, C.;
Abia, P. Garcia;
Ghiano, C.;
Giagu, S.;
Giganti, C.;
Giovanetti, G. K.;
Gorchakov, O.;
Goretti, A. M.;
Granato, F.;
Gromov, M.;
Guan, M.;
Guardincerri, Y.;
Gulino, M.;
Hackett, B. R.;
Hassanshahi, M. H.;
Herner, K.;
Hosseini, B.;
Hughes, D.;
Humble, P.;
Hungerford, E. V.;
Ianni, Al.;
Ianni, An.;
Ippolito, V.;
James, I.;
Johnson, T. N.;
Kahn, Y.;
Keeter, K.;
Kendziora, C. L.;
Kochanek, I.;
Koh, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kuss, M.;
La Commara, M.;
Lai, M.;
Li, X.;
Lisanti, M.;
Lissia, M.;
Loer, B.;
Longo, G.;
Ma, Y.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Mapelli, L.;
Mari, S. M.;
Maricic, J.;
Martoff, C. J.;
Messina, A.;
Meyers, P. D.;
Milincic, R.;
Mishra-Sharma, S.;
Monte, A.;
Morrocchi, M.;
Mount, B. J.;
Muratova, V. N.;
Musico, P.;
Nania, R.;
Agasson, A. Navrer;
Nozdrina, A. O.;
Oleinik, A.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Pazzona, F.;
Pelczar, K.;
Pelliccia, N.;
Pesudo, V.;
Pocar, A.;
Pordes, S.;
Poudel, S. S.;
Pugachev, D. A.;
Qian, H.;
Ragusa, F.;
Razeti, M.;
Razeto, A.;
Reinhold, B.;
Renshaw, A. L.;
Rescigno, M.;
Riffard, Q.;
Romani, A.;
Rossi, B.;
Rossi, N.;
Sablone, D.;
Samoylov, O.;
Sands, W.;
Sanfilippo, S.;
Sant, M.;
Santorelli, R.;
Savarese, C.;
Scapparone, E.;
Schlitzer, B.;
Segreto, E.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Singh, P. N.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sotnikov, A.;
Stanford, C.;
Stracka, S.;
Suffritti, G. B.;
Suvorov, Y.;
Tartaglia, R.;
Testera, G.;
Tonazzo, A.;
Trinchese, P.;
Unzhakov, E. V.;
Verducci, M.;
Vishneva, A.;
Vogelaar, B.;
Wada, M.;
Waldrop, T. J.;
Wang, H.;
Wang, Y.;
Watson, A. W.;
Westerdale, S.;
Wojcik, M. M.;
Wojcik, M.;
Xiang, X.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zhu, C.;
Zichichi, A.;
Zuzel, G.
Submitted: 2018-02-20, last modified: 2018-08-28
We present the results of a search for dark matter WIMPs in the mass range
below 20 GeV/c^2 using a target of low-radioactivity argon. The data were
obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso
(LNGS). The analysis is based on the ionization signal, for which the
DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The
observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and
is almost entirely accounted for by known background sources. We obtain a 90%
C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section
of dark matter WIMPs on nucleons, extending the exclusion region for dark
matter below previous limits in the range 1.8-6 GeV/c^2.