Normalized to: Daum, A.
[1]
oai:arXiv.org:astro-ph/0107174 [pdf] - 43545
Search for point sources and diffuse emission from the Galactic plane
with the HEGRA-IACT-system
Submitted: 2001-07-10
The HEGRA-IACT-system with a FoV of ~1.5 deg radius has been used for
surveying one quater of the Galactic disc in respect to point sources,
moderately extended sources and for diffuse emission in the energy range above
1 TeV. In total 140 h of good observation time were accumulated.
No new source has been discoverd. Limits on the level of 20% or lower of the
Crab flux on about 87 potential sources like SNR, Pulsars and EGRET sources are
derived. A limit on the diffuse emission is given on the level of dPhi/dE(E=1
TeV) = 6.1 10^-15 ph cm-2 s-1 sr-1 Mev-1 resulting in a lower limit of 2.5 on
the spectral index for the extrapolation of the meassured EGRET flux for the
diffuse emission.
[2]
oai:arXiv.org:astro-ph/9801092 [pdf] - 99941
Locating TeV Gamma-Ray Sources with Sub-Arcminute Precision: the
Pointing Calibration of the HEGRA System of Imaging Atmospheric Cherenkov
Telescopes
Submitted: 1998-01-12
Stereoscopic viewing of TeV gamma-ray air showers with systems of Imaging
Atmospheric Cherenkov Telescopes (IACTs) allows to reconstruct the origin of
individual primary particles with an accuracy of 0.1 degree or better. The
shower impact point can be determined within 15 meters. To actually achieve
this resolution, the pointing of the telescopes of an IACT system needs to be
controlled with high precision. For the HEGRA IACT system, a procedure to
calibrate telescope pointing was established, using bright stars distributed
over the sky as references. On the basis of these measurements, one determines
parameters of a correction function which is valid for the complete hemisphere.
After correction a pointing accuracy of 0.01 degree is achieved.
[3]
oai:arXiv.org:astro-ph/9712063 [pdf] - 99552
Characteristics of the Multi-Telescope Coincidence Trigger of the HEGRA
IACT System
Bulian, N.;
Daum, A.;
Hermann, G.;
Hess, M.;
Hofmann, W.;
Lampeitl, H.;
Puehlhofer, G.;
Koehler, C.;
Panter, M.;
Stein, M.;
Boerst, G.;
Rauterberg, G.;
Samorski, M.;
Sauerland, C.;
Stamm, W.
Submitted: 1997-12-04
The HEGRA--collaboration is operating a system of imaging atmospheric
Cherenkov telescopes to search for sources of TeV-gamma-rays. Air showers are
observed in stereoscopic mode with several telescopes simultaneously. To
trigger the telescope system a versatile two-level trigger scheme has been
implemented, which allows a significant reduction of the energy threshold with
respect to single telescopes. The technical implementation of this trigger
scheme and the performance of the trigger system are described. Results include
the dependence of single- and multi-telescope trigger rates on the trigger
thresholds, on the orientation of the telescopes, and on the type of the
primary particle.
[4]
oai:arXiv.org:astro-ph/9708003 [pdf] - 98181
An improved technique of image analysis for IACTs and IACT Systems
Submitted: 1997-08-01
In order to better utilize the information contained in the shower images
generated by imaging Cherenkov telescopes (IACTs) equipped with cameras with
small pixels, images are fit to a parametrization of image shapes gained from
Monte Carlo simulations, treating the shower direction, impact point, and
energy as free parameters. Monte Carlo studies for a system of IACTs predict an
improvement of order 1.5 in the angular resolution. The fitting technique can
also be applied to single-telescope images; simulations indicate that the
shower direction in space can be reconstructed event-by-event with a resolution
of 0.16 deg. to 0.20 deg., allowing to generate genuine source maps. Data from
Crab observations with a single HEGRA telescope confirm this prediction.