sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Dastgheibi-Fard, Ali

Normalized to: Dastgheibi-Fard, A.

4 article(s) in total. 55 co-authors, from 1 to 3 common article(s). Median position in authors list is 5,5.

[1]  oai:arXiv.org:1904.01944  [pdf] - 2065154
Development of Spherical Proportional Counter for light WIMP search within NEWS-G collaboration
Comments:
Submitted: 2019-04-03, last modified: 2019-05-03
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) has a broad range of applications. In this work, we will focus on the light WIMP Dark Matter particle search, that is, below a few GeV. The NEWS-G collaboration operates a 60 cm diameter detector at Modane underground laboratory (LSM). Running the detector at 3 b of Neon gas, some competitive limits have been set down to 0.5 GeV WIMP mass thanks to an energy threshold of around 100 eV. To reach better performances, the next generation of SPC (140cm), NEWS-G SNO, is under construction. We will focus here on the fabrication method, the different low energy calibration methods using 37Ar, neutron and UV laser, on the cleaning methods to remove the surface contamination and mitigation of 210Pb bulk contamination.
[2]  oai:arXiv.org:1902.08960  [pdf] - 1890376
Precision laser-based measurements of the single electron response of SPCs for the NEWS-G light dark matter search experiment
Comments: 12 pages, 8 figures, submitted to Phys. Rev. D
Submitted: 2019-02-24
Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and analysis methodology are presented along with various direct applications for the upcoming next phase of the experiment at SNOLAB. These include the continuous monitoring of the detector response and electron drift properties during dark matter search runs, as well as the experimental measurement of the trigger threshold efficiency. We measure a mean ionization energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$ for 2.8 keV X-rays, and demonstrate the feasibility of performing similar precision measurements at sub-keV energies for future gas mixtures to be used for dark matter searches at SNOLAB.
[3]  oai:arXiv.org:1706.04934  [pdf] - 1604802
First results from the NEWS-G direct dark matter search experiment at the LSM
Comments: 18 pages, 10 figures, acknowledgments section updated
Submitted: 2017-06-15, last modified: 2017-09-07
New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection experiment using Spherical Proportional Counters (SPCs) with light noble gases to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report the results from the first physics run taken at the Laboratoire Souterrain de Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the spin-independent WIMP-nucleon scattering cross-section in the sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times \mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5 $\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to be installed at SNOLAB by summer 2018.
[4]  oai:arXiv.org:1412.0161  [pdf] - 904473
Background optimization for a new spherical gas detector for very light WIMP detection
Comments: 5 pages, 3 figures
Submitted: 2014-11-29
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) is a novel type of par- ticle detector, with a broad range of applications. Its main features include a very low energy threshold independent of the volume (due to its very low capacitance), a good energy resolution, robustness and a single detection readout channel, in its simplest version. Applications range from radon emanation gas monitoring, neutron flux and gamma counting and spectroscopy to dark matter searches, in particular low mass WIMPs and coherent neutrino scattering measure- ment. Laboratories interested in these various applications share expertise within the NEWS (New Experiments With Sphere) network. SEDINE, a low background prototype installed at underground site of Laboratoire Souterrain de Modane is currently being operated and aims at measuring events at very low energy threshold, around 100 eV. We will present the energy cali- bration with 37Ar, the surface background reduction, the measurement of detector background at sub-keV energies, and show anticipated sensitivities for light dark matter search.