Normalized to: Dastgheibi-Fard, A.
[1]
oai:arXiv.org:1904.01944 [pdf] - 2065154
Development of Spherical Proportional Counter for light WIMP search
within NEWS-G collaboration
Submitted: 2019-04-03, last modified: 2019-05-03
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) has a
broad range of applications. In this work, we will focus on the light WIMP Dark
Matter particle search, that is, below a few GeV. The NEWS-G collaboration
operates a 60 cm diameter detector at Modane underground laboratory (LSM).
Running the detector at 3 b of Neon gas, some competitive limits have been set
down to 0.5 GeV WIMP mass thanks to an energy threshold of around 100 eV. To
reach better performances, the next generation of SPC (140cm), NEWS-G SNO, is
under construction. We will focus here on the fabrication method, the different
low energy calibration methods using 37Ar, neutron and UV laser, on the
cleaning methods to remove the surface contamination and mitigation of 210Pb
bulk contamination.
[2]
oai:arXiv.org:1902.08960 [pdf] - 1890376
Precision laser-based measurements of the single electron response of
SPCs for the NEWS-G light dark matter search experiment
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Bard, J. -P.;
Brossard, A.;
Chapellier, M.;
Clark, M.;
Crawford, S.;
Corcoran, E. C.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Giroux, G.;
Gorel, P.;
Gros, M.;
Gros, P.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Knights, P.;
Langrock, S.;
Lautridou, P.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Nikolopoulos, K.;
Piquemal, F.;
Piro, M. -C.;
Santos, D.;
Savvidis, G.;
Savvidis, I.;
Fernandez, F. Vazquez de Sola;
Vidal, M.;
Zampaolo, M.
Submitted: 2019-02-24
Spherical Proportional Counters (SPCs) are a novel gaseous detector
technology employed by the NEWS-G low-mass dark matter search experiment for
their high sensitivity to single electrons from ionization. In this paper, we
report on the first characterization of the single electron response of SPCs
with unprecedented precision, using a UV-laser calibration system. The
experimental approach and analysis methodology are presented along with various
direct applications for the upcoming next phase of the experiment at SNOLAB.
These include the continuous monitoring of the detector response and electron
drift properties during dark matter search runs, as well as the experimental
measurement of the trigger threshold efficiency. We measure a mean ionization
energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$
for 2.8 keV X-rays, and demonstrate the feasibility of performing similar
precision measurements at sub-keV energies for future gas mixtures to be used
for dark matter searches at SNOLAB.
[3]
oai:arXiv.org:1706.04934 [pdf] - 1604802
First results from the NEWS-G direct dark matter search experiment at
the LSM
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Asner, D.;
Bard, J. -P.;
Brossard, A.;
Cai, B.;
Chapellier, M.;
Clark, M.;
Corcoran, E. C.;
Dandl, T.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Gorel, P.;
Gros, M.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Navick, X. -F.;
Papaevangelou, T.;
Piquemal, F.;
Roth, S.;
Santos, D.;
Savvidis, I.;
Ulrich, A.;
Fernandez, F. Vazquez de Sola;
Zampaolo, M.
Submitted: 2017-06-15, last modified: 2017-09-07
New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection
experiment using Spherical Proportional Counters (SPCs) with light noble gases
to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report
the results from the first physics run taken at the Laboratoire Souterrain de
Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a
mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total
exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the
spin-independent WIMP-nucleon scattering cross-section in the
sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times
\mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5
$\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are
promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to
be installed at SNOLAB by summer 2018.
[4]
oai:arXiv.org:1412.0161 [pdf] - 904473
Background optimization for a new spherical gas detector for very light
WIMP detection
Dastgheibi-Fard, Ali;
Giomataris, I.;
Gerbierb, G.;
Derree, J.;
Gros, M.;
Magnier, P.;
Jourde, D.;
Bougamont, E .;
Navick, X-F.;
Papaevangelou, T.;
Galan, J.;
Tsiledakis, G.;
Piquemal, F.;
Zampaolo, M.;
Loaiza, P.;
Savvidis, I.
Submitted: 2014-11-29
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) is a
novel type of par- ticle detector, with a broad range of applications. Its main
features include a very low energy threshold independent of the volume (due to
its very low capacitance), a good energy resolution, robustness and a single
detection readout channel, in its simplest version. Applications range from
radon emanation gas monitoring, neutron flux and gamma counting and
spectroscopy to dark matter searches, in particular low mass WIMPs and coherent
neutrino scattering measure- ment. Laboratories interested in these various
applications share expertise within the NEWS (New Experiments With Sphere)
network. SEDINE, a low background prototype installed at underground site of
Laboratoire Souterrain de Modane is currently being operated and aims at
measuring events at very low energy threshold, around 100 eV. We will present
the energy cali- bration with 37Ar, the surface background reduction, the
measurement of detector background at sub-keV energies, and show anticipated
sensitivities for light dark matter search.