Normalized to: Daley, S.
[1]
oai:arXiv.org:1510.07754 [pdf] - 1382070
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Amole, C.;
Ardid, M.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Daley, S.;
Das, M.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Grandison, A.;
Hai, M.;
Hall, J.;
Harris, O.;
Jin, M.;
Krauss, C. B.;
Fallows, S.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Maurya, D.;
Mitra, P.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Ramberg, E.;
Robinson, A. E.;
Rucinski, R.;
Ruschman, M.;
Scallon, O.;
Seth, S.;
Simon, P.;
Sonnenschein, A.;
Štekl, I.;
Vàzquez-Jàuregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.;
Shkrob, I. A.
Submitted: 2015-10-26, last modified: 2016-03-03
New data are reported from the operation of the PICO-60 dark matter detector,
a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB
underground laboratory. PICO-60 is the largest bubble chamber to search for
dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60
exhibits the same excellent background rejection observed in smaller bubble
chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic
calorimetry, similar but not identical to that reported recently in a
C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown
background events, exhibiting acoustic, spatial, and timing behaviors
inconsistent with those expected from a dark matter signal. These behaviors
allow for analysis cuts to remove all background events while retaining
$48.2\%$ of the exposure. Stringent limits on weakly interacting massive
particles interacting via spin-dependent proton and spin-independent processes
are set, and most interpretations of the DAMA/LIBRA modulation signal as dark
matter interacting with iodine nuclei are ruled out.
[2]
oai:arXiv.org:1503.00008 [pdf] - 1238863
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Daley, S.;
Das, M.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Felis, I.;
Filgas, R.;
Fines-Neuschild, M.;
Girard, F.;
Giroux, G.;
Hai, M.;
Hall, J.;
Harris, O.;
Jackson, C. M.;
Jin, M.;
Krauss, C. B.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Martin, J. P.;
Maurya, D.;
Mitra, P.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Robinson, A. E.;
Ruschman, M.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Vàzquez-Jaùregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.
Submitted: 2015-02-27, last modified: 2015-06-29
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble
chamber in the 2100 meter deep SNOLAB underground laboratory, with a total
exposure of 211.5 kg-days at four different recoil energy thresholds ranging
from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron
recoil and alpha rejection capabilities at very low thresholds, including the
first observation of a dependence of acoustic signal on alpha energy. Twelve
single nuclear recoil event candidates were observed during the run. The
candidate events exhibit timing characteristics that are not consistent with
the hypothesis of a uniform time distribution, and no evidence for a dark
matter signal is claimed. These data provide the most sensitive direct
detection constraints on WIMP-proton spin-dependent scattering to date, with
significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon
scattering.