Normalized to: Dahl, C.
[1]
oai:arXiv.org:1907.12509 [pdf] - 2100293
Velocity independent constraints on spin-dependent DM-nucleon
interactions from IceCube and PICO
IceCube Collaboration;
Aartsen, M. G.;
Ackermann, M.;
Adams, J.;
Aguilar, J. A.;
Ahlers, M.;
Ahrens, M.;
Alispach, C.;
Andeen, K.;
Anderson, T.;
Ansseau, I.;
Anton, G.;
Argüelles, C.;
Auffenberg, J.;
Axani, S.;
Backes, P.;
Bagherpour, H.;
Bai, X.;
V., A. Balagopal;
Barbano, A.;
Barwick, S. W.;
Bastian, B.;
Baum, V.;
Baur, S.;
Bay, R.;
Beatty, J. J.;
Becker, K. -H.;
Tjus, J. Becker;
BenZvi, S.;
Berley, D.;
Bernardini, E.;
Besson, D. Z.;
Binder, G.;
Bindig, D.;
Blaufuss, E.;
Blot, S.;
Bohm, C.;
Börner, M.;
Böser, S.;
Botner, O.;
Böttcher, J.;
Bourbeau, E.;
Bourbeau, J.;
Bradascio, F.;
Braun, J.;
Bron, S.;
Brostean-Kaiser, J.;
Burgman, A.;
Buscher, J.;
Busse, R. S.;
Carver, T.;
Chen, C.;
Cheung, E.;
Chirkin, D.;
Choi, S.;
Classen, L.;
Coleman, A.;
Collin, G. H.;
Conrad, J. M.;
Coppin, P.;
Correa, P.;
Cowen, D. F.;
Cross, R.;
Dave, P.;
De Clercq, C.;
DeLaunay, J. J.;
Dembinski, H.;
Deoskar, K.;
De Ridder, S.;
Desiati, P.;
de Vries, K. D.;
de Wasseige, G.;
de With, M.;
DeYoung, T.;
Diaz, A.;
Díaz-Vélez, J. C.;
Dujmovic, H.;
Dunkman, M.;
Dvorak, E.;
Eberhardt, B.;
Ehrhardt, T.;
Eller, P.;
Engel, R.;
Evenson, P. A.;
Fahey, S.;
Fazely, A. R.;
Felde, J.;
Filimonov, K.;
Finley, C.;
Franckowiak, A.;
Friedman, E.;
Fritz, A.;
Gaisser, T. K.;
Gallagher, J.;
Ganster, E.;
Garrappa, S.;
Gerhardt, L.;
Ghorbani, K.;
Glauch, T.;
Glüsenkamp, T.;
Goldschmidt, A.;
Gonzalez, J. G.;
Grant, D.;
Griffith, Z.;
Griswold, S.;
Günder, M.;
Gündüz, M.;
Haack, C.;
Hallgren, A.;
Halve, L.;
Halzen, F.;
Hanson, K.;
Haungs, A.;
Hebecker, D.;
Heereman, D.;
Heix, P.;
Helbing, K.;
Hellauer, R.;
Henningsen, F.;
Hickford, S.;
Hignight, J.;
Hill, G. C.;
Hoffman, K. D.;
Hoffmann, R.;
Hoinka, T.;
Hokanson-Fasig, B.;
Hoshina, K.;
Huang, F.;
Huber, M.;
Huber, T.;
Hultqvist, K.;
Hünnefeld, M.;
Hussain, R.;
In, S.;
Iovine, N.;
Ishihara, A.;
Japaridze, G. S.;
Jeong, M.;
Jero, K.;
Jones, B. J. P.;
Jonske, F.;
Joppe, R.;
Kang, D.;
Kang, W.;
Kappes, A.;
Kappesser, D.;
Karg, T.;
Karl, M.;
Karle, A.;
Katz, U.;
Kauer, M.;
Kelley, J. L.;
Kheirandish, A.;
Kim, J.;
Kintscher, T.;
Kiryluk, J.;
Kittler, T.;
Klein, S. R.;
Koirala, R.;
Kolanoski, H.;
Köpke, L.;
Kopper, C.;
Kopper, S.;
Koskinen, D. J.;
Kowalski, M.;
Krings, K.;
Krückl, G.;
Kulacz, N.;
Kurahashi, N.;
Kyriacou, A.;
Labare, M.;
Lanfranchi, J. L.;
Larson, M. J.;
Lauber, F.;
Lazar, J. P.;
Leonard, K.;
Leszczyńska, A.;
Leuermann, M.;
Liu, Q. R.;
Lohfink, E.;
Mariscal, C. J. Lozano;
Lu, L.;
Lucarelli, F.;
Lünemann, J.;
Luszczak, W.;
Lyu, Y.;
Ma, W. Y.;
Madsen, J.;
Maggi, G.;
Mahn, K. B. M.;
Makino, Y.;
Mallik, P.;
Mallot, K.;
Mancina, S.;
Mariş, I. C.;
Maruyama, R.;
Mase, K.;
Maunu, R.;
McNally, F.;
Meagher, K.;
Medici, M.;
Medina, A.;
Meier, M.;
Meighen-Berger, S.;
Menne, T.;
Merino, G.;
Meures, T.;
Micallef, J.;
Mockler, D.;
Momenté, G.;
Montaruli, T.;
Moore, R. W.;
Morse, R.;
Moulai, M.;
Muth, P.;
Nagai, R.;
Naumann, U.;
Neer, G.;
Niederhausen, H.;
Nowicki, S. C.;
Nygren, D. R.;
Pollmann, A. Obertacke;
Oehler, M.;
Olivas, A.;
O'Murchadha, A.;
O'Sullivan, E.;
Palczewski, T.;
Pandya, H.;
Pankova, D. V.;
Park, N.;
Peiffer, P.;
Heros, C. Pérez de los;
Philippen, S.;
Pieloth, D.;
Pinat, E.;
Pizzuto, A.;
Plum, M.;
Porcelli, A.;
Price, P. B.;
Przybylski, G. T.;
Raab, C.;
Raissi, A.;
Rameez, M.;
Rauch, L.;
Rawlins, K.;
Rea, I. C.;
Reimann, R.;
Relethford, B.;
Renschler, M.;
Renzi, G.;
Resconi, E.;
Rhode, W.;
Richman, M.;
Robertson, S.;
Rongen, M.;
Rott, C.;
Ruhe, T.;
Ryckbosch, D.;
Rysewyk, D.;
Safa, I.;
Herrera, S. E. Sanchez;
Sandrock, A.;
Sandroos, J.;
Santander, M.;
Sarkar, S.;
Sarkar, S.;
Satalecka, K.;
Schaufel, M.;
Schieler, H.;
Schlunder, P.;
Schmidt, T.;
Schneider, A.;
Schneider, J.;
Schröder, F. G.;
Schumacher, L.;
Sclafani, S.;
Seckel, D.;
Seunarine, S.;
Shefali, S.;
Silva, M.;
Snihur, R.;
Soedingrekso, J.;
Soldin, D.;
Song, M.;
Spiczak, G. M.;
Spiering, C.;
Stachurska, J.;
Stamatikos, M.;
Stanev, T.;
Stein, R.;
Steinmüller, P.;
Stettner, J.;
Steuer, A.;
Stezelberger, T.;
Stokstad, R. G.;
Stößl, A.;
Strotjohann, N. L.;
Stürwald, T.;
Stuttard, T.;
Sullivan, G. W.;
Taboada, I.;
Tenholt, F.;
Ter-Antonyan, S.;
Terliuk, A.;
Tilav, S.;
Tomankova, L.;
Tönnis, C.;
Toscano, S.;
Tosi, D.;
Trettin, A.;
Tselengidou, M.;
Tung, C. F.;
Turcati, A.;
Turcotte, R.;
Turley, C. F.;
Ty, B.;
Unger, E.;
Elorrieta, M. A. Unland;
Usner, M.;
Vandenbroucke, J.;
Van Driessche, W.;
van Eijk, D.;
van Eijndhoven, N.;
Vanheule, S.;
van Santen, J.;
Vraeghe, M.;
Walck, C.;
Wallace, A.;
Wallraff, M.;
Wandkowsky, N.;
Watson, T. B.;
Weaver, C.;
Weindl, A.;
Weiss, M. J.;
Weldert, J.;
Wendt, C.;
Werthebach, J.;
Whelan, B. J.;
Whitehorn, N.;
Wiebe, K.;
Wiebusch, C. H.;
Wille, L.;
Williams, D. R.;
Wills, L.;
Wolf, M.;
Wood, J.;
Wood, T. R.;
Woschnagg, K.;
Wrede, G.;
Xu, D. L.;
Xu, X. W.;
Xu, Y.;
Yanez, J. P.;
Yodh, G.;
Yoshida, S.;
Yuan, T.;
Collaboration, M. Zöcklein. PICO;
:;
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hoppe, E. W.;
Jin, M.;
Klopfenstein, L.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mamedov, F.;
Maurya, D.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Piro, M. -C.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Walkowski, N.;
Wichoski, U.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-07-29, last modified: 2020-05-25
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity
distribution for dark matter (DM) particles in the Galaxy, the most stringent
current constraints on their spin-dependent scattering cross-section with
nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$
superheated bubble chamber experiments. The former is sensitive to high energy
neutrinos from the self-annihilation of DM particles captured in the Sun, while
the latter looks for nuclear recoil events from DM scattering off nucleons.
Although slower DM particles are more likely to be captured by the Sun, the
faster ones are more likely to be detected by PICO. Recent N-body simulations
suggest significant deviations from the SHM for the smooth halo component of
the DM, while observations hint at a dominant fraction of the local DM being in
substructures. We use the method of Ferrer et al. (2015) to exploit the
complementarity between the two approaches and derive conservative constraints
on DM-nucleon scattering. Our results constrain $\sigma_{\mathrm{SD}} \lesssim
3 \times 10^{-39} \mathrm{cm}^2$ (6 $ \times 10^{-38} \mathrm{cm}^2$) at
$\gtrsim 90\%$ C.L. for a DM particle of mass 1~TeV annihilating into $\tau^+
\tau^-$ ($b\bar{b}$) with a local density of $\rho_{\mathrm{DM}} = 0.3~\mathrm{
GeV/cm}^3$. The constraints scale inversely with $\rho_{\mathrm{DM}}$ and are
independent of the DM velocity distribution.
[2]
oai:arXiv.org:1802.06039 [pdf] - 2061504
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Akerib, D. S.;
Akerlof, C. W.;
Alsum, S. K.;
Araújo, H. M.;
Arthurs, M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Bauer, D.;
Belle, J.;
Beltrame, P.;
Benson, T.;
Bernard, E. P.;
Biesiadzinski, T. P.;
Boast, K. E.;
Boxer, B.;
Brás, P.;
Buckley, J. H.;
Bugaev, V. V.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Chan, C.;
Cherwinka, J. J.;
Cole, A.;
Cottle, A.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
Dahl, C. E.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, W. R.;
Fan, A.;
Fayer, S.;
Fiorucci, S.;
Fruth, T.;
Gaitskell, R. J.;
Genovesi, J.;
Ghag, C.;
Gilchriese, M. G. D.;
van der Grinten, M. G. D.;
Hall, C. R.;
Hans, S.;
Hanzel, K.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hillbrand, S.;
Hjemfelt, C.;
Hoff, M. D.;
Hor, J. Y-K.;
Huang, D. Q.;
Ignarra, C. M.;
Ji, W.;
Kaboth, A. C.;
Kamdin, K.;
Keefner, J.;
Khaitan, D.;
Khazov, A.;
Kim, Y. D.;
Kocher, C. D.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kreczko, L.;
Krikler, B.;
Kudryavtsev, V. A.;
Kyre, S.;
Lee, J.;
Lenardo, B. G.;
Leonard, D. S.;
Lesko, K. T.;
Levy, C.;
Li, J.;
Liao, J.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Linehan, R.;
Lippincott, W. H.;
Liu, X.;
Lopes, M. I.;
Paredes, B. López;
Lorenzon, W.;
Luitz, S.;
Lyle, J. M.;
Majewski, P.;
Manalaysay, A.;
Mannino, R. L.;
Maupin, C.;
McKinsey, D. N.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Morrison, E.;
Mount, B. J.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikoleyczik, J.;
O'Sullivan, K.;
Olcina, I.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Patton, S. J.;
Pease, E. K.;
Penning, B.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Rhyne, C. A.;
Richards, A.;
Rodrigues, J. P.;
Rosero, R.;
Rossiter, P.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silk, J. J.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stancu, I.;
Stark, M. R.;
Stiegler, T. M.;
Stifter, K.;
Szydagis, M.;
Taylor, W. C.;
Taylor, R.;
Taylor, D. J.;
Temples, D.;
Terman, P. A.;
Thomas, K. J.;
Timalsina, M.;
To, W. H.;
Tomás, A.;
Tope, T. E.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Utku, U.;
Va'vra, J.;
Vacheret, A.;
Verbus, J. R.;
Voirin, E.;
Waldron, W. L.;
Watson, J. R.;
Webb, R. C.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, I.
Submitted: 2018-02-16, last modified: 2019-12-02
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment
that will operate 4850 feet underground at the Sanford Underground Research
Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector
with an active mass of 7 tonnes, LZ will search primarily for low-energy
interactions with Weakly Interacting Massive Particles (WIMPs), which are
hypothesized to make up the dark matter in our galactic halo. In this paper,
the projected WIMP sensitivity of LZ is presented based on the latest
background estimates and simulations of the detector. For a 1000 live day run
using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence
level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$
cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$
discovery potential is projected reaching cross sections below the existing and
projected exclusion limits of similar experiments that are currently operating.
For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7
\times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40
$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well
underway, LZ is on track for commissioning at SURF in 2020.
[3]
oai:arXiv.org:1905.12522 [pdf] - 1995410
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$
Bubble Chambers
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chen, S.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Filgas, R.;
Fuentes, J.;
Girard, F.;
Giroux, G.;
Hackett, B.;
Hagen, A.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Kozynets, T.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Pal, S.;
Piro, M. -C.;
Plante, A.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Tiwari, D.;
Vázquez-Jáuregui, E.;
Wagner, J. M.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Woodley, W.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-05-29, last modified: 2019-11-06
The primary advantage of moderately superheated bubble chamber detectors is
their simultaneous sensitivity to nuclear recoils from WIMP dark matter and
insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO
gamma calibration data demonstrates for the first time that electron recoils in
C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one
driven by a hot-spike as previously supposed. Using this semi-empirical model,
bubble chamber nucleation thresholds may be tuned to be sensitive to lower
energy nuclear recoils while maintaining excellent electron recoil rejection.
The PICO-40L detector will exploit this model to achieve thermodynamic
thresholds as low as 2.8 keV while being dominated by single-scatter events
from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one
year of operation, PICO-40L can improve existing leading limits from PICO on
spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP
masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all
existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP
masses from 3 to 40 GeV c$^{-2}$.
[5]
oai:arXiv.org:1910.07450 [pdf] - 1981331
Proceedings of The Magnificent CE$\nu$NS Workshop 2018
Sierra, D. Aristizabal;
Balantekin, A. B.;
Caratelli, D.;
Cogswell, B.;
Collar, J. I.;
Dahl, C. E.;
Dent, J.;
Dutta, B.;
Engel, J.;
Estrada, J.;
Formaggio, J.;
Gariazzo, S.;
Han, R.;
Hedges, S.;
Huber, P.;
Konovalov, A.;
Lang, R. F.;
Liao, S.;
Lindner, M.;
Machado, P.;
Mahapatra, R.;
Marfatia, D.;
Martinez-Soler, I.;
Miranda, O.;
Misiak, D.;
Naumov, D. V.;
Newby, J.;
Newstead, J.;
Papoulias, D.;
Patton, K.;
Pereverzev, S.;
Pospelov, M.;
Scholberg, K.;
Sinev, G.;
Strauss, R.;
Strigari, L.;
Tayloe, R.;
Tiffenberg, J.;
Vidal, M.;
Vignati, M.;
Wagner, V.;
Walker, J.;
Yu, T. -T.;
Zettlemoyer, J.;
Rich, G. C.
Submitted: 2019-10-16
The Magnificent CE$\nu$NS Workshop (2018) was held November 2 & 3 of 2018 on
the University of Chicago campus and brought together theorists,
phenomenologists, and experimentalists working in numerous areas but sharing a
common interest in the process of coherent elastic neutrino-nucleus scattering
(CE$\nu$NS). This is a collection of abstract-like summaries of the talks given
at the meeting, including links to the slides presented. This document and the
slides from the meeting provide an overview of the field and a snapshot of the
robust CE$\nu$NS-related efforts both planned and underway.
[6]
oai:arXiv.org:1907.00104 [pdf] - 1920124
On orbit performance of the GRACE Follow-On Laser Ranging Interferometer
Abich, Klaus;
Braxmaier, Claus;
Gohlke, Martin;
Sanjuan, Josep;
Abramovici, Alexander;
Okihiro, Brian Bachman;
Barr, David C.;
Bize, Maxime P.;
Burke, Michael J.;
Clark, Ken C.;
de Vine, Glenn;
Dickson, Jeffrey A.;
Dubovitsky, Serge;
Folkner, William M.;
Francis, Samuel;
Gilbert, Martin S.;
Katsumura, Mark;
Klipstein, William;
Larsen, Kameron;
Liebe, Carl Christian;
Liu, Jehhal;
McKenzie, Kirk;
Morton, Phillip R.;
Murray, Alexander T.;
Nguyen, Don J.;
Ravich, Joshua A.;
Shaddock, Daniel;
Spero, Robert;
Spiers, Gary;
Sutton, Andrew;
Trinh, Joseph;
Wang, Duo;
Wang, Rabi T.;
Ware, Brent;
Woodruff, Christopher;
Amparan, Bengie;
Davis, Mike A.;
Howell, James;
Kruger, Micah;
Lobmeyer, Lynette;
Pierce, Robert;
Reavis, Gretchen;
Sileo, Michael;
Stephens, Michelle;
Baatzsch, Andreas;
Dahl, Christian;
Dahl, Katrin;
Gilles, Frank;
Hager, Philipp;
Herding, Mark;
Kaufer, Marina;
Nicklaus, Kolja;
Voss, Kai;
Bogan, Christina;
Danzmann, Karsten;
Barranco, Germán Fernández;
Heinzel, Gerhard;
Koch, Alexander;
Mahrdt, Christoph;
Misfeldt, Malte;
Müller, Vitali;
Reiche, Jens;
Schütze, Daniel;
Sheard, Benjamin;
Stede, Gunnar;
Wegener, Henry;
Eckardt, Andreas;
Guenther, Burghardt;
Mangoldt, Thomas;
Zender, Bernd;
Ester, Thomas;
Heine, Frank;
Seiter, Christoph;
Windisch, Steve;
Flatscher, Reinhold;
Flechtner, Frank;
Grossard, Nicolas;
Hauden, Jerome;
Hinz, Martin;
Leikert, Thomas;
Zimmermann, Marcus;
Lebeda, Anton;
Lebeda, Arnold
Submitted: 2019-06-28
The Laser Ranging Interferometer (LRI) instrument on the Gravity Recovery and
Climate Experiment (GRACE) Follow-On mission has provided the first laser
interferometric range measurements between remote spacecraft, separated by
approximately 220 km. Autonomous controls that lock the laser frequency to a
cavity reference and establish the 5 degree of freedom two-way laser link
between remote spacecraft succeeded on the first attempt. Active beam pointing
based on differential wavefront sensing compensates spacecraft attitude
fluctuations. The LRI has operated continuously without breaks in phase
tracking for more than 50 days, and has shown biased range measurements similar
to the primary ranging instrument based on microwaves, but with much less noise
at a level of $1\,{\rm nm}/\sqrt{\rm Hz}$ at Fourier frequencies above 100 mHz.
[7]
oai:arXiv.org:1902.04031 [pdf] - 1916812
Dark Matter Search Results from the Complete Exposure of the PICO-60
C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Piro, M. -C.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-02-11
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark
matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in
the SNOLAB underground laboratory. The chamber was operated at thermodynamic
thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day
exposure at 2.45 keV threshold was acquired with approximately the same
expected total background rate as the previous 1167-kg-day exposure at 3.3 keV.
This increased exposure is enabled in part by a new optical tracking analysis
to better identify events near detector walls, permitting a larger fiducial
volume. These results set the most stringent direct-detection constraint to
date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$
cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV
WIMPs by an order of magnitude.
[8]
oai:arXiv.org:1702.07666 [pdf] - 1581621
Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Campion, P.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Crowder, G.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Harris, O.;
Hoppe, E. W.;
Jin, M.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mamedov, F.;
Maurya, D.;
Mitra, P.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Olson, S.;
Ortega, A.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Roeder, A.;
Rucinski, R.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Wells, J.;
Wichoski, U.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2017-02-24, last modified: 2017-08-02
New results are reported from the operation of the PICO-60 dark matter
detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the
SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60
C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and
the observed multiple-scattering neutron rate indicates a single-scatter
neutron background of less than 1 event per month. A blind analysis of an
efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold
reveals no single-scattering nuclear recoil candidates, consistent with the
predicted background. These results set the most stringent direct-detection
constraint to date on the WIMP-proton spin-dependent cross section at 3.4
$\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one
order of magnitude improvement from previous PICO results.
[9]
oai:arXiv.org:1702.08861 [pdf] - 1581679
First Demonstration of a Scintillating Xenon Bubble Chamber for
Detecting Dark Matter and Coherent Elastic Neutrino-Nucleus Scattering
Baxter, D.;
Chen, C. J.;
Crisler, M.;
Cwiok, T.;
Dahl, C. E.;
Grimsted, A.;
Gupta, J.;
Jin, M.;
Puig, R.;
Temples, D.;
Zhang, J.
Submitted: 2017-02-28, last modified: 2017-06-08
A 30-g xenon bubble chamber, operated at Northwestern University in June and
November 2016, has for the first time observed simultaneous bubble nucleation
and scintillation by nuclear recoils in a superheated liquid. This chamber is
instrumented with a CCD camera for near-IR bubble imaging, a solar-blind
photomultiplier tube to detect 175-nm xenon scintillation light, and a
piezoelectric acoustic transducer to detect the ultrasonic emission from a
growing bubble. The time of nucleation determined from the acoustic signal is
used to correlate specific scintillation pulses with bubble-nucleating events.
We report on data from this chamber for thermodynamic "Seitz" thresholds from
4.2 to 15.0 keV. The observed single- and multiple-bubble rates when exposed to
a $^{252}$Cf neutron source indicate that, for an 8.3-keV thermodynamic
threshold, the minimum nuclear recoil energy required to nucleate a bubble is
$19\pm6$ keV (1$\sigma$ uncertainty). This is consistent with the observed
scintillation spectrum for bubble-nucleating events. We see no evidence for
bubble nucleation by gamma rays at any of the thresholds studied, setting a 90%
C.L. upper limit of $6.3\times10^{-7}$ bubbles per gamma interaction at a
4.2-keV thermodynamic threshold. This indicates stronger gamma discrimination
than in CF$_3$I bubble chambers, supporting the hypothesis that scintillation
production suppresses bubble nucleation by electron recoils while nuclear
recoils nucleate bubbles as usual. These measurements establish the
noble-liquid bubble chamber as a promising new technology for the detection of
weakly interacting massive particle dark matter and coherent elastic
neutrino-nucleus scattering.
[11]
oai:arXiv.org:1601.03729 [pdf] - 1382109
Improved dark matter search results from PICO-2L Run 2
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Das, M.;
Debris, F.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Fines-Neuschild, M.;
Girard, F.;
Giroux, G.;
Hall, J.;
Harris, O.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Krauss, C. B.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Martin, J. P.;
Maurya, D.;
Mitra, P.;
Olson, S.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Robinson, A. E.;
Ruschman, M.;
Scallon, O.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Vázquez-Jáuregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.
Submitted: 2016-01-14, last modified: 2016-03-25
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$
bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic
threshold energy of 3.3$\,$keV. These data show that measures taken to control
particulate contamination in the superheated fluid resulted in the absence of
the anomalous background events observed in the first run of this bubble
chamber. One single nuclear-recoil event was observed in the data, consistent
both with the predicted background rate from neutrons and with the observed
rate of unambiguous multiple-bubble neutron scattering events. The chamber
exhibits the same excellent electron-recoil and alpha decay rejection as was
previously reported. These data provide the most stringent direct detection
constraints on weakly interacting massive particle (WIMP)-proton spin-dependent
scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.
[12]
oai:arXiv.org:1510.07754 [pdf] - 1382070
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Amole, C.;
Ardid, M.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Daley, S.;
Das, M.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Grandison, A.;
Hai, M.;
Hall, J.;
Harris, O.;
Jin, M.;
Krauss, C. B.;
Fallows, S.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Maurya, D.;
Mitra, P.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Ramberg, E.;
Robinson, A. E.;
Rucinski, R.;
Ruschman, M.;
Scallon, O.;
Seth, S.;
Simon, P.;
Sonnenschein, A.;
Štekl, I.;
Vàzquez-Jàuregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.;
Shkrob, I. A.
Submitted: 2015-10-26, last modified: 2016-03-03
New data are reported from the operation of the PICO-60 dark matter detector,
a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB
underground laboratory. PICO-60 is the largest bubble chamber to search for
dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60
exhibits the same excellent background rejection observed in smaller bubble
chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic
calorimetry, similar but not identical to that reported recently in a
C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown
background events, exhibiting acoustic, spatial, and timing behaviors
inconsistent with those expected from a dark matter signal. These behaviors
allow for analysis cuts to remove all background events while retaining
$48.2\%$ of the exposure. Stringent limits on weakly interacting massive
particles interacting via spin-dependent proton and spin-independent processes
are set, and most interpretations of the DAMA/LIBRA modulation signal as dark
matter interacting with iodine nuclei are ruled out.
[13]
oai:arXiv.org:1509.02910 [pdf] - 1286987
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration;
Akerib, D. S.;
Akerlof, C. W.;
Akimov, D. Yu.;
Alsum, S. K.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Barry, M. J.;
Bauer, P.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boast, K. E.;
Bolozdynya, A. I.;
Boulton, E. M.;
Bramante, R.;
Buckley, J. H.;
Bugaev, V. V.;
Bunker, R.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Cascella, M.;
Chan, C.;
Cherwinka, J. J.;
Chiller, A. A.;
Chiller, C.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
da Cunha, J. P.;
Dahl, C. E.;
Dasu, S.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, B. N.;
Edwards, W. R.;
Elnimr, M. M.;
Emmet, W. T.;
Faham, C. H.;
Fiorucci, S.;
Ford, P.;
Francis, V. B.;
Fu, C.;
Gaitskell, R. J.;
Gantos, N. J.;
Gehman, V. M.;
Gerhard, R. M.;
Ghag, C.;
Gilchriese, M. G. D.;
Gomber, B.;
Hall, C. R.;
Harris, A.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hoff, M. D.;
Holbrook, B.;
Holtom, E.;
Huang, D. Q.;
Hurteau, T. W.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Ji, X.;
Johnson, M.;
Ju, Y.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Khazov, A.;
Khromov, A. V.;
Konovalov, A. M.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kudryavtsev, V. A.;
Kumpan, A. V.;
Kyre, S.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Lippincott, W. H.;
Liu, J.;
Liu, X.;
Lopes, M. I.;
Lorenzon, W.;
Luitz, S.;
Majewski, P.;
Malling, D. C.;
Manalaysay, A. G.;
Manenti, L.;
Mannino, R. L.;
Markley, D. J.;
Martin, T. J.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. -M.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikkel, J. A.;
O'Neill, F. G.;
O'Dell, J.;
O'Sullivan, K.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pangilinan, M.;
Patton, S. J.;
Pease, E. K.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Reichhart, L.;
Rhyne, C.;
Rodrigues, J. P.;
Rose, H. J.;
Rosero, R.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M. S. G.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Sosnovtsev, V. V.;
Stancu, I.;
Stark, M. R.;
Stephenson, S.;
Stiegler, T. M.;
Sumner, T. J.;
Sundarnath, K.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W.;
Tennyson, B. P.;
Terman, P. A.;
Thomas, K. J.;
Thomson, J. A.;
Tiedt, D. R.;
To, W. H.;
Tomás, A.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Uvarov, S.;
Va'vra, J.;
van der Grinten, M. G. D.;
Verbus, J. R.;
Vuosalo, C. O.;
Waldron, W. L.;
Wang, L.;
Webb, R. C.;
Wei, W. -Z.;
While, M.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, E.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, S. K.;
Zhang, C.
Submitted: 2015-09-09, last modified: 2015-09-23
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.
[14]
oai:arXiv.org:1503.00008 [pdf] - 1238863
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Daley, S.;
Das, M.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Felis, I.;
Filgas, R.;
Fines-Neuschild, M.;
Girard, F.;
Giroux, G.;
Hai, M.;
Hall, J.;
Harris, O.;
Jackson, C. M.;
Jin, M.;
Krauss, C. B.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Martin, J. P.;
Maurya, D.;
Mitra, P.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Robinson, A. E.;
Ruschman, M.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Vàzquez-Jaùregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.
Submitted: 2015-02-27, last modified: 2015-06-29
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble
chamber in the 2100 meter deep SNOLAB underground laboratory, with a total
exposure of 211.5 kg-days at four different recoil energy thresholds ranging
from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron
recoil and alpha rejection capabilities at very low thresholds, including the
first observation of a dependence of acoustic signal on alpha energy. Twelve
single nuclear recoil event candidates were observed during the run. The
candidate events exhibit timing characteristics that are not consistent with
the hypothesis of a uniform time distribution, and no evidence for a dark
matter signal is claimed. These data provide the most sensitive direct
detection constraints on WIMP-proton spin-dependent scattering to date, with
significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon
scattering.
[15]
oai:arXiv.org:1304.6001 [pdf] - 778562
Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I
Bubble Chamber
COUPP Collaboration;
Behnke, E.;
Benjamin, T.;
Brice, S. J.;
Broemmelsiek, D.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Fustin, D.;
Hall, J.;
Harnish, C.;
Levine, I.;
Lippincott, W. H.;
Moan, T.;
Nania, T.;
Neilson, R.;
Ramberg, E.;
Robinson, A. E.;
Sonnenschein, A.;
Vázquez-Jáuregui, E.;
Rivera, R. A.;
Uplegger, L.
Submitted: 2013-04-22, last modified: 2014-01-31
We have directly measured the energy threshold and efficiency for bubble
nucleation from iodine recoils in a CF3I bubble chamber in the energy range of
interest for a dark matter search. These interactions cannot be probed by
standard neutron calibration methods, so we develop a new technique by
observing the elastic scattering of 12 GeV/c negative pions. The pions are
tracked with a silicon pixel telescope and the reconstructed scattering angle
provides a measure of the nuclear recoil kinetic energy. The bubble chamber was
operated with a nominal threshold of (13.6+-0.6) keV. Interpretation of the
results depends on the response to fluorine and carbon recoils, but in general
we find agreement with the predictions of the classical bubble nucleation
theory. This measurement confirms the applicability of CF3I as a target for
spin-independent dark matter interactions and represents a novel technique for
calibration of superheated fluid detectors.
[16]
oai:arXiv.org:1104.3088 [pdf] - 661239
A search for light dark matter in XENON10 data
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2011-04-15, last modified: 2013-05-07
We report results of a search for light (<10 GeV) particle dark matter with
the XENON10 detector. The event trigger was sensitive to a single electron,
with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear
recoil energy. Considering spin-independent dark matter-nucleon scattering, we
exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle
mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic
dark matter interpretations of excess low-energy events observed by CoGeNT and
CRESST-II, as well as the DAMA annual modulation signal.
[17]
oai:arXiv.org:1207.3665 [pdf] - 1124847
The LUX Prototype Detector: Heat Exchanger Development
Akerib, D. S.;
Bai, X.;
Bedikian, S.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Cahn, S.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Curioni, A.;
Dahl, C. E.;
Dazeley, S.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Fiorucci, S.;
Gaitskell, R. J.;
Hall, C.;
Faham, C.;
Holbrook, B.;
Kastens, L.;
Kazkaz, K.;
Kwong, J.;
Lander, R.;
Leonard, D.;
Malling, D.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Morii, M.;
Nikkel, J.;
Phelps, P.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Steigler, T.;
Svoboda, R.;
Sweany, M.;
Thomson, J.;
Tripathi, M.;
Walsh, N.;
Webb, R.;
White, J.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-07-16, last modified: 2013-01-20
The LUX (Large Underground Xenon) detector is a two-phase xenon Time
Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter
interactions. As with all noble element detectors, continuous purification of
the detector medium is essential to produce a large ($>$1ms) electron lifetime;
this is necessary for efficient measurement of the electron signal which in
turn is essential for achieving robust discrimination of signal from background
events. In this paper we describe the development of a novel purification
system deployed in a prototype detector. The results from the operation of this
prototype indicated heat exchange with an efficiency above 94% up to a flow
rate of 42 slpm, allowing for an electron drift length greater than 1 meter to
be achieved in approximately two days and sustained for the duration of the
testing period.
[18]
oai:arXiv.org:1204.3094 [pdf] - 565655
First dark matter search results from a 4-kg CF$_3$I bubble chamber
operated in a deep underground site
Behnke, E.;
Behnke, J.;
Brice, S. J.;
Broemmelsiek, D.;
Collar, J. I.;
Conner, A.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Fustin, D.;
Grace, E.;
Hall, J.;
Hu, M.;
Levine, I.;
Lippincott, W. H.;
Moan, T.;
Nania, T.;
Ramberg, E.;
Robinson, A. E.;
Sonnenschein, A.;
Szydagis, M.;
Vázquez-Jáuregui, E.
Submitted: 2012-04-13, last modified: 2012-09-19
New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber
in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of
ultrasound analysis in discriminating alpha-decay background events from single
nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of
alpha-decay events. Twenty single nuclear recoil event candidates and three
multiple bubble events were observed during a total exposure of 553 kg-days
distributed over three different bubble nucleation thresholds. The effective
exposure for single bubble recoil-like events was 437.4 kg-days. A neutron
background internal to the apparatus, of known origin, is estimated to account
for five single nuclear recoil events and is consistent with the observed rate
of multiple bubble events. This observation provides world best direct
detection constraints on WIMP-proton spin-dependent scattering for WIMP masses
$>$20 GeV/c$^{2}$ and demonstrates significant sensitivity for spin-independent
interactions.
[19]
oai:arXiv.org:1111.6192 [pdf] - 530964
Comments on "First Results of the Phase II SIMPLE Dark Matter Search"
Submitted: 2011-11-26
The SIMPLE Collaboration has reported results from their superheated C2ClF5
droplet detectors, including a description of acoustic discrimination between
\alpha decays and nuclear recoils. Our concern is that the events in the
neutron calibration data and the events identified as neutrons in the physics
data are not drawn from the same parent distribution. This fact calls into
question the identification of the background events as neutrons, the use of
the calibration data to define the acceptance of WIMP-induced nuclear recoils,
and the observation of discrimination against \alpha's.
[20]
oai:arXiv.org:1008.3518 [pdf] - 326586
Improved Limits on Spin-Dependent WIMP-Proton Interactions from a Two
Liter CF$_3$I Bubble Chamber
Behnke, E.;
Behnke, J.;
Brice, S. J.;
Broemmelsiek, D.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Fustin, D.;
Hall, J.;
Hinnefeld, J. H.;
Hu, M.;
Levine, I.;
Ramberg, E.;
Shepherd, T.;
Sonnenschein, A.;
Szydagis, M.
Submitted: 2010-08-20, last modified: 2011-03-07
Data from the operation of a bubble chamber filled with 3.5 kg of CF$_{3}$I
in a shallow underground site are reported. An analysis of ultrasound signals
accompanying bubble nucleations confirms that alpha decays generate a
significantly louder acoustic emission than single nuclear recoils, leading to
an efficient background discrimination. Three dark matter candidate events were
observed during an effective exposure of 28.1 kg-day, consistent with a neutron
background. This observation provides the strongest direct detection constraint
to date on WIMP-proton spin-dependent scattering for WIMP masses $>20$
GeV/c$^{2}$.
[21]
oai:arXiv.org:1101.6080 [pdf] - 332996
Nuclear recoil energy scale in liquid xenon with application to the
direct detection of dark matter
Submitted: 2011-01-31
We show for the first time that the quenching of electronic excitation from
nuclear recoils in liquid xenon is well-described by Lindhard theory, if the
nuclear recoil energy is reconstructed using the combined (scintillation and
ionization) energy scale proposed by Shutt {\it et al.}. We argue for the
adoption of this perspective in favor of the existing preference for
reconstructing nuclear recoil energy solely from primary scintillation. We show
that signal partitioning into scintillation and ionization is well-described by
the Thomas-Imel box model. We discuss the implications for liquid xenon
detectors aimed at the direct detection of dark matter.
[22]
oai:arXiv.org:0910.3698 [pdf] - 270011
Constraints on inelastic dark matter from XENON10
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2009-10-19, last modified: 2010-11-30
It has been suggested that dark matter particles which scatter inelastically
from detector target nuclei could explain the apparent incompatibility of the
DAMA modulation signal (interpreted as evidence for particle dark matter) with
the null results from CDMS-II and XENON10. Among the predictions of
inelastically interacting dark matter are a suppression of low-energy events,
and a population of nuclear recoil events at higher nuclear recoil equivalent
energies. This is in stark contrast to the well-known expectation of a falling
exponential spectrum for the case of elastic interactions. We present a new
analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV
nuclear recoil equivalent energy. Our results exclude a significant region of
previously allowed parameter space in the model of inelastically interacting
dark matter. In particular, it is found that dark matter particle masses
$m_{\chi}\gtrsim150$ GeV are disfavored.
[23]
oai:arXiv.org:1011.6439 [pdf] - 270289
Lowering the low-energy threshold of xenon detectors
Sorensen, P.;
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2010-11-29
We show that the energy threshold for nuclear recoils in the XENON10 dark
matter search data can be lowered to ~1 keV, by using only the ionization
signal. In other words, we make no requirement that a valid event contain a
primary scintillation signal. We therefore relinquish incident particle type
discrimination, which is based on the ratio of ionization to scintillation in
liquid xenon. This method compromises the detector's ability to precisely
determine the z coordinate of a particle interaction. However, we show for the
first time that it is possible to discriminate bulk events from surface events
based solely on the ionization signal.
[24]
oai:arXiv.org:1001.2834 [pdf] - 348097
Design and Performance of the XENON10 Dark Matter Experiment
Aprile, E.;
Angle, J.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Orlandi, D.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Tatananni, E.;
Winant, C.;
Yamashita, M.
Submitted: 2010-01-16
XENON10 is the first two-phase xenon time projection chamber (TPC) developed
within the XENON dark matter search program. The TPC, with an active liquid
xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground
laboratory (LNGS) in Italy, and operated for more than one year, with excellent
stability and performance. Results from a dark matter search with XENON10 have
been published elsewhere. In this paper, we summarize the design and
performance of the detector and its subsystems, based on calibration data using
sources of gamma-rays and neutrons as well as background and Monte Carlo
simulations data. The results on the detector's energy threshold, energy and
position resolution, and overall efficiency show a performance that exceeds
design specifications, in view of the very low energy threshold achieved (<10
keVr) and the excellent energy resolution achieved by combining the ionization
and scintillation signals, detected simultaneously.
[25]
oai:arXiv.org:0908.0790 [pdf] - 1003308
Scintillation Pulse Shape Discrimination in a Two-Phase Xenon Time
Projection Chamber
Submitted: 2009-08-06
The energy and electric field dependence of pulse shape discrimination in
liquid xenon have been measured in a 10 gm two-phase xenon time projection
chamber. We have demonstrated the use of the pulse shape and charge-to-light
ratio simultaneously to obtain a leakage below that achievable by either
discriminant alone. A Monte Carlo is used to show that the dominant fluctuation
in the pulse shape quantity is statistical in nature, and project the
performance of these techniques in larger detectors. Although the performance
is generally weak at low energies relevant to elastic WIMP recoil searches, the
pulse shape can be used in probing for higher energy inelastic WIMP recoils.
[26]
oai:arXiv.org:0807.0459 [pdf] - 1937508
The scintillation and ionization yield of liquid xenon for nuclear
recoils
Sorensen, P.;
Manzur, A.;
Dahl, C. E.;
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2008-07-03, last modified: 2008-12-30
XENON10 is an experiment designed to directly detect particle dark matter. It
is a dual phase (liquid/gas) xenon time-projection chamber with 3D position
imaging. Particle interactions generate a primary scintillation signal (S1) and
ionization signal (S2), which are both functions of the deposited recoil energy
and the incident particle type. We present a new precision measurement of the
relative scintillation yield \leff and the absolute ionization yield Q_y, for
nuclear recoils in xenon. A dark matter particle is expected to deposit energy
by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for
establishing the energy threshold of the experiment; this in turn determines
the sensitivity to particle dark matter. Our \leff measurement is in agreement
with recent theoretical predictions above 15 keV nuclear recoil energy, and the
energy threshold of the measurement is 4 keV. A knowledge of the ionization
yield \Qy is necessary to establish the trigger threshold of the experiment.
The ionization yield \Qy is measured in two ways, both in agreement with
previous measurements and with a factor of 10 lower energy threshold.
[27]
oai:arXiv.org:0805.2939 [pdf] - 1937505
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10
experiment
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2008-05-19, last modified: 2008-09-10
XENON10 is an experiment to directly detect weakly interacting massive
particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter
in our Universe. We report new results for spin-dependent WIMP-nucleon
interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the
Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a
WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously
unexplored regions in the theoretically allowed parameter space for
neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range
of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its
density and distribution in the galactic halo.
[28]
oai:arXiv.org:0706.0039 [pdf] - 1934124
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso
National Laboratory
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2007-05-31, last modified: 2007-12-03
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg
xenon dual phase time projection chamber (XeTPC) to search for dark matter
weakly interacting massive particles (WIMPs). The detector measures
simultaneously the scintillation and the ionization produced by radiation in
pure liquid xenon, to discriminate signal from background down to 4.5 keV
nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired
between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4
kg, excludes previously unexplored parameter space, setting a new 90% C.L.
upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x
10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a
WIMP mass of 30 GeV/c^2. This result further constrains predictions of
supersymmetric models.
[29]
oai:arXiv.org:astro-ph/0608137 [pdf] - 84014
Performance and Fundamental Processes at Low Energy in a Two-Phase
Liquid Xenon Dark Matter Detector
Submitted: 2006-08-06, last modified: 2006-09-29
We extend the study of the performance of a prototype two-phase liquid xenon
WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new
method for obtaining the best estimate of the energies of events using a
calibrated sum of charge and light signals and introduce the corresponding
discrimination parameter, giving its mean value at 4 kV/cm for electron and
nuclear recoils up to 300 and 100 keV, respectively. We show that fluctuations
in recombination limit discrimination for most energies, and reveal an
improvement in discrimination below 20 keV due to a surprising increase in
ionization yield for low energy electron recoils. This improvement is crucial
for a high-sensitivity dark matter search.
[30]
oai:arXiv.org:astro-ph/0601552 [pdf] - 79410
Simultaneous Measurement of Ionization and Scintillation from Nuclear
Recoils in Liquid Xenon as Target for a Dark Matter Experiment
Aprile, E.;
Dahl, C. E.;
DeViveiros, L.;
Gaitskell, R.;
Giboni, K. L.;
Kwong, J.;
Majewski, P.;
Ni, K.;
Shutt, T.;
Yamashita, M.
Submitted: 2006-01-24
We report the first measurements of the absolute ionization yield of nuclear
recoils in liquid xenon, as a function of energy and electric-field.
Independent experiments were carried out with two dual-phase time projection
chamber prototypes, developed for the XENON Dark Matter project. We find that
the charge yield increases with decreasing recoil energy, and exhibits only a
weak field dependence. These results are a first demonstration of the
capability of dual phase xenon detectors to discriminate between electron and
nuclear recoils, a key requirement for a sensitive dark matter search at recoil
energies down to 20 keV.