sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Dafni, T.

Normalized to: Dafni, T.

25 article(s) in total. 383 co-authors, from 1 to 20 common article(s). Median position in authors list is 5,0.

[1]  oai:arXiv.org:1910.13957  [pdf] - 2097246
The TREX-DM experiment at the Canfranc Underground Laboratory
Comments: TAUP2019 proceedings
Submitted: 2019-10-30, last modified: 2020-03-22
TREX-DM (TPC Rare Event eXperiment for Dark Matter) is intended to look for low mass WIMPs in the Canfranc Underground Laboratory (LSC) in Spain, using light elements (Ne, Ar) as target in a high pressure TPC equipped with Micromegas readouts. Here, a description of the detector, the first results from commissioning data and the expected sensitivity from the developed background model are briefly presented.
[2]  oai:arXiv.org:1812.04519  [pdf] - 1983798
Background assessment for the TREX Dark Matter experiment
Comments: Final version, as accepted in Eur. Phys. J. C
Submitted: 2018-12-11, last modified: 2019-09-22
TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30 kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered acquisition, allowing for thresholds below 0.4 keV (electron equivalent). A low background level in the lowest energy region is another essential requirement. To assess the expected background, all the relevant sources have been considered, including the measured fluxes of gamma radiation, muons and neutrons at the Canfranc Laboratory, together with the activity of most of the components used in the detector and ancillary systems, obtained in a complete assay program. The background contributions have been simulated by means of a dedicated application based on Geant4 and a custom-made code for the detector response. The background model developed for the detector presently installed in Canfranc points to levels from 1 to 10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive in the search for low-mass WIMPs. A roadmap to further decrease it down to 0.1 counts keV-1 kg-1 d-1 is underway.
[3]  oai:arXiv.org:1906.01084  [pdf] - 1894436
First Results on the Search for Chameleons with the KWISP Detector at CAST
Comments: 21 pages, 12 figures
Submitted: 2019-06-03
We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of solar chameleons. The displacements are detected by a Michelson interferometer with a homodyne readout scheme. The sensor benefits from the focusing action of the ABRIXAS X-ray telescope installed at CAST, which increases the chameleon flux on the membrane. A mechanical chopper placed between the telescope output and the detector modulates the incoming chameleon stream. We present the results of the solar chameleon measurements taken at CAST in July 2017, setting an upper bound on the force acting on the membrane of $80$~pN at 95\% confidence level. The detector is sensitive for direct coupling to matter $10^4 \leq\beta_m \leq 10^8$, where the coupling to photons is locally bound to $\beta_\gamma \leq 10^{11}$.
[4]  oai:arXiv.org:1811.09290  [pdf] - 1842424
Weighing the Solar Axion
Comments: 13 pages, 7 figures, matches published version, code available at http://cajohare.github.io/IAXOmass
Submitted: 2018-11-22, last modified: 2019-02-20
Axion helioscopes search for solar axions and axion-like particles via inverse Primakoff conversion in strong laboratory magnets pointed at the Sun. While helioscopes can always measure the axion coupling to photons, the conversion signal is independent of the mass for axions lighter than around 0.02 eV. Masses above this value on the other hand have suppressed signals due to axion-photon oscillations which destroy the coherence of the conversion along the magnet. However, the spectral oscillations present in the axion conversion signal between these two regimes are highly dependent on the axion mass. We show that these oscillations are observable given realistic energy resolutions and can be used to determine the axion mass to within percent level accuracies. Using projections for the upcoming helioscope IAXO, we demonstrate that $>3\sigma$ sensitivity to a non-zero axion mass is possible between $3 \times 10^{-3}$ and $10^{-1}$ eV for both the Primakoff and axion-electron solar fluxes.
[5]  oai:arXiv.org:1706.05818  [pdf] - 1598065
Cosmogenic production of tritium in dark matter detectors
Comments: Final version as published
Submitted: 2017-06-19, last modified: 2017-11-24
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and long half-life) when induced in the detector medium, and because it can be generated in any material as a spallation product. Quantification of cosmogenic production of tritium is not straightforward, neither experimentally nor by calculations. In this work, a method for the calculation of production rates at sea level has been developed and applied to some of the materials typically used as targets in dark matter detectors (germanium, sodium iodide, argon and neon); it is based on a selected description of tritium production cross sections over the entire energy range of cosmic nucleons. Results have been compared to available data in the literature, either based on other calculations or from measurements. The obtained tritium production rates, ranging from a few tens to a few hundreds of nuclei per kg and per day at sea level, point to a significant contribution to the background in dark matter experiments, requiring the application of specific protocols for target material purification, material storing underground and limiting the time the detector is on surface during the building process in order to minimize the exposure to the most dangerous cosmic ray components.
[6]  oai:arXiv.org:1709.10062  [pdf] - 1589033
Status of the TREX-DM experiment at the Canfranc Underground Laboratory
Comments: To appear in the Proceedings of the XV International Conference on Topics in Astroparticle and Underground Physics (TAUP2017) at Journal of Physics: Conference Series (JPCS)
Submitted: 2017-09-28
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a gas time projection chamber equipped with novel micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg of Ne. The micromegas will be read with a self-triggered acquisition, allowing for effective thresholds below 0.4 keV (electron equivalent). The preliminary background model, following a complete material screening program, points to levels of the order of 1-10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive. The status of the commissioning, description of the background model and the corresponding WIMP sensitivity will be presented here.
[7]  oai:arXiv.org:1610.02396  [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Comments: 58 pages, 26 figures, accepted by Physics Reports
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
[8]  oai:arXiv.org:1503.04561  [pdf] - 1376478
Search for chameleons with CAST
Comments: 8 pages, 12 figures
Submitted: 2015-03-16, last modified: 2016-03-18
In this work we present a search for (solar) chameleons with the CERN Axion Solar Telescope (CAST). This novel experimental technique, in the field of dark energy research, exploits both the chameleon coupling to matter ($\beta_{\rm m}$) and to photons ($\beta_{\gamma}$) via the Primakoff effect. By reducing the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV CAST became sensitive to the converted solar chameleon spectrum which peaks around 600$\,$eV. Even though we have not observed any excess above background, we can provide a 95% C.L. limit for the coupling strength of chameleons to photons of $\beta_{\gamma}\!\lesssim\!10^{11}$ for $1<\beta_{\rm m}<10^6$.
[9]  oai:arXiv.org:1509.06190  [pdf] - 1323484
A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research
Comments: 21 pages, 16 figures
Submitted: 2015-09-21
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed (or "slumped") glass substrates deposited with multilayer coatings. The system has been conceived as a technological pathfinder for the future International Axion Observatory (IAXO), as it combines two of the techniques (optic and detector) proposed in the conceptual design of the project. It is innovative for two reasons: it is the first time an x-ray optic has been designed and fabricated specifically for axion research, and the first time a Micromegas detector has been operated with an x-ray optic. The line has been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and is currently looking for solar axions. The combination of the XRT and Micromegas detector provides the best signal-to-noise ratio obtained so far by any detection system of the CAST experiment with a background rate of 5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and signal spot area.
[10]  oai:arXiv.org:1508.03006  [pdf] - 1330987
Exploring 0.1-10$\,$eV axions with a new helioscope concept
Comments: prepared for submission to JCAP
Submitted: 2015-08-12, last modified: 2015-09-07
We explore the possibility to develop a new axion helioscope type, sensitive to the higher axion mass region favored by axion models. We propose to use a low background large volume TPC immersed in an intense magnetic field. Contrary to traditional tracking helioscopes, this detection technique takes advantage of the capability to directly detect the photons converted on the buffer gas which defines the axion mass sensitivity region, and does not require pointing the magnet to the Sun. The operation flexibility of a TPC to be used with different gas mixtures (He, Ne, Xe, etc) and pressures (from 10 mbar to 10 bar) will allow to enhance sensitivity for axion masses from few meV to several eV. We present different helioscope data taking scenarios, considering detection efficiency and axion absorption probability, and show the sensitivities reachable with this technique to be few $\times$ 10$^{-11}\,$GeV$^{-1}$ for a 5$\,$T$\,$m$^3$ scale TPC. We show that a few years program taking data with such setup would allow to probe the KSVZ axion model for axion masses above 100 meV.
[11]  oai:arXiv.org:1501.01466  [pdf] - 918435
Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches
Comments: Proceedings of 3rd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2014)
Submitted: 2015-01-07
Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. In this work, we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Observatory (IAXO). The actual setup in CAST has achieved background levels below 10$^{-6}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$, a factor 100 lower than the first generation of Micromegas detectors. This reduction is based on active and passive shielding techniques, the selection of radiopure materials, offline discrimination techniques and the high granularity of the readout. We describe in detail the background model of the detector, based on its operation at CAST site and at the Canfranc Underground Laboratory (LSC), as well as on Geant4 simulations. The best levels currently achieved at LSC are low than 10$^{-7}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$ and show good prospects for the application of this technology in IAXO. Finally, we present some ideas and results for reducing the energy threshold of these detectors below 1 keV, using high-transparent windows, autotrigger electronics and studying the cluster shape at different energies. As a high flux of axion-like-particles is expected in this energy range, a sub-keV threshold detector could enlarge the physics case of axion helioscopes.
[12]  oai:arXiv.org:1501.01456  [pdf] - 1937998
Axion helioscopes update: the status of CAST and IAXO
Comments: Proceedings of 3rd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2014)
Submitted: 2015-01-07
Almost 35 years since their suggestion as a good solution to the strong CP-problem, axions remain one of the few viable candidates for the Dark Matter, although still eluding detection. Most of the methods for their detection are based on their coupling to photons, one of the most sensitive ones being the helioscope technique. We report on the current status of the CERN Axion Solar Telescope and the future International Axion Observatory (IAXO). Recent results from the second part of CAST phase II, where the magnet bores were filled with 3He gas at variable pressure achieving sensibilities on the axion mass up to 1.2 eV, are presented. Currently, CAST is expecting to improve its sensitivity to solar axions with rest mass below 0.02 eV/c^2 after the upgrade of the X-ray detectors and with the implementation of a second X-ray optic. At the same time, it is exploring other possibilities at the low energy physics frontier. On the other hand IAXO, the fourth generation axion helioscope, aims to improve CAST's performance in terms of axion-photon coupling by 1-1.5 orders of magnitude. The details of the project building a dedicated magnet, optics and X-ray detectors are given.
[13]  oai:arXiv.org:1307.1985  [pdf] - 867037
CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap
Comments: 5 pages, 2 figures. Last version uploaded
Submitted: 2013-07-08, last modified: 2014-09-15
The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on the pressure setting. Future direct solar axion searches will focus on increasing the sensitivity to smaller values of g_a, for example by the currently discussed next generation helioscope IAXO.
[14]  oai:arXiv.org:1211.4508  [pdf] - 1157898
Ionization and scintillation response of high-pressure xenon gas to alpha particles
Comments: 36 pages, 19 figures, 5 tables. Version accepted for publication in JINST
Submitted: 2012-11-19, last modified: 2013-05-21
High-pressure xenon gas is an attractive detection medium for a variety of applications in fundamental and applied physics. In this paper we study the ionization and scintillation detection properties of xenon gas at 10 bar pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO time projection chamber, the large scale prototype of the NEXT-100 neutrinoless double beta decay experiment, in three different drift electric field configurations. We measure the ionization electron drift velocity and longitudinal diffusion, and compare our results to expectations based on available electron scattering cross sections on pure xenon. In addition, two types of measurements addressing the connection between the ionization and scintillation yields are performed. On the one hand we observe, for the first time in xenon gas, large event-by-event correlated fluctuations between the ionization and scintillation signals, similar to that already observed in liquid xenon. On the other hand, we study the field dependence of the average scintillation and ionization yields. Both types of measurements may shed light on the mechanism of electron-ion recombination in xenon gas for highly-ionizing particles. Finally, by comparing the response of alpha particles and electrons in NEXT-DEMO, we find no evidence for quenching of the primary scintillation light produced by alpha particles in the xenon gas.
[15]  oai:arXiv.org:1302.6283  [pdf] - 928601
CAST constraints on the axion-electron coupling
Comments:
Submitted: 2013-02-25, last modified: 2013-04-19
In non-hadronic axion models, which have a tree-level axion-electron interaction, the Sun produces a strong axion flux by bremsstrahlung, Compton scattering, and axio-recombination, the "BCA processes." Based on a new calculation of this flux, including for the first time axio-recombination, we derive limits on the axion-electron Yukawa coupling g_ae and axion-photon interaction strength g_ag using the CAST phase-I data (vacuum phase). For m_a < 10 meV/c2 we find g_ag x g_ae< 8.1 x 10^-23 GeV^-1 at 95% CL. We stress that a next-generation axion helioscope such as the proposed IAXO could push this sensitivity into a range beyond stellar energy-loss limits and test the hypothesis that white-dwarf cooling is dominated by axion emission.
[16]  oai:arXiv.org:1210.3287  [pdf] - 1152052
Micromegas-TPC operation at high pressure in xenon-trimethylamine mixtures
Comments:
Submitted: 2012-10-11, last modified: 2012-11-23
In this work we present a systematic study of Micromegas detectors in high pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains and energy resolutions for 22.1 keV X-rays are measured for pressures between 1 and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We observe stable operation at all pressures, and a strongly enhanced gas gain, suggestive of Penning-like energy-transfer processes. The effect is present at all pressures and it is strongest at TMA concentrations ranging from 1.5 % to 3 %. Operating in this concentration range, the maximum gain reached values as high as x10^3 (x10^2) at 1 (10) bar. Besides, the energy resolution achievable for 22.1 keV X-rays is substantially better than the one previously obtained in pure Xe, going down to 7.3 % (9.6 %) FWHM for 1 (10) bar. These results are of interest for calorimetric applications of high pressure gas Xe TPCs, in particular for the search of the neutrinoless double beta decay of Xe-136. The resolutions achieved would extrapolate into 0.7 % (0.9 %) FWHM at the Qbb value of Xe-136 for 1 (10) bar.
[17]  oai:arXiv.org:1209.6347  [pdf] - 1453905
Results and perspectives of the solar axion search with the CAST experiment
Comments: 4 pages, 2 pages, to appear in the proceedings of the 24th Rencontres de Blois V2 A few affiliations were not corrected in previous version V3 Author added
Submitted: 2012-09-27, last modified: 2012-10-30
The status of the solar axion search with the CERN Axion Solar Telescope (CAST) will be presented. Recent results obtained by the use of $^3$He as a buffer gas has allowed us to extend our sensitivity to higher axion masses than our previous measurements with $^4$He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV$ \le m_{a} \le $ 0.64 eV. From the absence of an excess of x rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g$_{a\gamma} \le 2.3\times 10^{-10}$ GeV$^{-1}$ at 95% C.L., the exact value depending on the pressure setting. CAST published results represent the best experimental limit on the photon couplings to axions and other similar exotic particles dubbed WISPs (Weakly Interacting Slim Particles) in the considered mass range and for the first time the limit enters the region favored by QCD axion models. Preliminary sensitivities for axion masses up to 1.16 eV will also be shown reaching mean upper limits on the axion-photon coupling of g$_{a\gamma} \le 3.5\times 10^{-10}$ GeV$^{-1}$ at 95% C.L. Expected sensibilities for the extension of the CAST program up to 2014 will be presented. Moreover long term options for a new helioscope experiment will be evoked.
[18]  oai:arXiv.org:1208.5690  [pdf] - 771411
CAST microbulk micromegas in the Canfranc Underground Laboratory
Comments: 6 pages, 8 figures. To appear in the proceedings of the 2nd International Conference on Technology and Instrumentation for Particle Physics (TIPP 2011)
Submitted: 2012-08-28
During the last taking data campaigns of the CAST experiment, the micromegas detectors have achieved background levels of $\approx 5 \times 10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has been possible thanks to the introduction of the microbulk technology, the implementation of a shielding and the development of discrimination algorithms. It has motivated new studies towards a deeper understanding of CAST detectors background. One of the working lines includes the construction of a replica of the set-up used in CAST by micromegas detectors and its installation in the Canfranc Underground Laboratory. Thanks to the comparison between the performance of the detectors underground and at surface, shielding upgrades, etc, different contributions to the detectors background have been evaluated. In particular, an upper limit $< 2 \times 10^{-7}$keV$^{-1}$cm$^{-2}$s$^{-1}$ for the intrinsic background of the detector has been obtained. This work means a first evaluation of the potential of the newest micromegas technology in an underground laboratory, the most suitable environment for Rare Event Searches.
[19]  oai:arXiv.org:1112.4329  [pdf] - 453283
Solar flares as harbinger of new physics
Comments: 6 pages, 3 figures. To appear in the proceedings of the 7th Patras Workshop on Axions, WIMPs and WISPs, 2011
Submitted: 2011-12-19
This work provides additional evidence on the involvement of exotic particles like axions and/or other WISPs, following recent measurements during the quietest Sun and flaring Sun. Thus, SPHINX mission observed a minimum basal soft X-rays emission in the extreme solar minimum in 2009. The same scenario (with ~17 meV axions) fits also the dynamical behaviour of white-light solar flares, like the measured spectral components in the visible and in soft X-rays, and, the timing between them. Solar chameleons remain a viable candidate, since they may preferentially convert to photons in outer space.
[20]  oai:arXiv.org:1110.2608  [pdf] - 1084811
Low X-ray bakground measurements at the Underground Canfranc Laboratory
Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011
Submitted: 2011-10-12, last modified: 2011-10-25
Micromegas detectors, thanks to the good spatial and temporal discrimination capabilities, are good candidates for rare event search experiments. Recent X-ray background levels achieved by these detectors in the CAST experiment have motivated further studies in the nature of the background levels measured. In particular, different shielding configurations have been tested at the Canfranc Underground Laboratory, using a microbulk type detector which was previously running at the CAST experiment. The first results underground show that this technology, which is made of low radiative materials, is able to reach background levels up to $2 \times 10^{-7}$keV$^{-1}$s$^{-1}$cm$^{-2}$ with a proper shielding. Moreover, the experimental background measurements are complemented with Geant4 simulations which allow to understand the origin of the background, and to optimize future shielding set-ups.
[21]  oai:arXiv.org:1011.0629  [pdf] - 251428
Signatures for Solar Axions/WISPs
Comments: To appear in the proceedings of the 6th Patras Workshop, Zurich 5-9 July 2010
Submitted: 2010-11-02
Standard solar physics cannot account for the X-ray emission and other puzzles, the most striking example being the solar corona mystery. The corona temperature rise above the non-flaring magnetized sunspots, while the photosphere just underneath becomes cooler, makes this mystery more intriguing. The paradoxical Sun is suggestive of some sort of exotic solution, axions being the (only?) choice for the missing ingredient. We present atypical axion signatures, which depict solar axions with a rest mass max ~17 meV/c2. Then, the Sun has been for decades the overlooked harbinger of new particle physics.
[22]  oai:arXiv.org:1009.1827  [pdf] - 261761
Micromegas readouts for double beta decay searches
Comments: 15 pages, 11 figures. Accepted for publication in JCAP
Submitted: 2010-09-09
Double beta $\beta\beta$ decay experiments are one of the most active research topics in Neutrino Physics. The measurement of the neutrinoless mode $0\nu\beta\beta$ could give unique information on the neutrino mass scale and nature. The current generation of experiments aims at detector target masses at the 100 kg scale, while the next generation will need to go to the ton scale in order to completely explore the inverse hierarchy models of neutrino mass. Very good energy resolutions and ultra-low background levels are the two main experimental requirements for a successful experiment. The topological information of the $\beta\beta$ events offered by gaseous detectors like gas Time Projection Chambers (TPC) could provide a very powerful tool of signal identification and background rejection. However only recent advances in TPC readouts may assure the competitiveness of a high pressure gas TPCs for $\beta\beta$ searches, especially regarding the required energy resolution. In this paper we present first results on energy resolution with state-of-the-art microbulk Micromesh Gas Amplification Structure (Micromegas) using a 5.5 MeV alpha source in high pressure pure xenon. Resolutions down to 2 % FWHM have been achieved for pressures up to 5 bar. These results, together with their recently measured radiopurity , prove that Micromegas readouts are not only a viable option but a very competitive one for $\beta\beta$ searches.
[23]  oai:arXiv.org:1003.2181  [pdf] - 129063
Solar X-rays from Axions: Rest-Mass Dependent Signatures
Comments: To appear in Proceedings of the 5th Patras Axion Workshop, Durham 2009
Submitted: 2010-03-10
The spectral shape of solar X-rays is a power law. The more active the Sun is, the less steep the distribution. This behaviour can be explained by axion regeneration to X-rays occurring ~400km deep into the photosphere. Their down-comptonization reproduces the measured spectral shape, pointing at axions with rest mass m_a~17 meV/c2, without contradicting astrophysical-laboratory limits. Directly measured soft X-ray spectra from the extremely quiet Sun during 2009 (SphinX mission), though hitherto overlooked, fitt the axion scenario.
[24]  oai:arXiv.org:0911.0323  [pdf] - 902277
The case for a directional dark matter detector and the status of current experimental efforts
Comments: 48 pages, 37 figures, whitepaper on direct dark matter detection with directional sensitivity
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.
[25]  oai:arXiv.org:0903.1807  [pdf] - 900649
Axion Searches with Helioscopes and astrophysical signatures for axion(-like) particles
Comments: 31 pages, 18 figures. Aded 1 author, updated references. Accepted for the special issue of NJP on dark matter (July 2009)
Submitted: 2009-03-10, last modified: 2009-05-27
The first part reviews the working mechanisms, capabilities and performance of axion helioscopes, including the achieved results so far. The 2nd part is observationally driven. New simulation results obtained with the Geant4 code reconstruct spectral shape of solar X-ray spectra, and their isotropic emission and lateral size. The derived rst mass of the axion(-like) particles is ~10meV. The axion interaction with magnetic field gradient is a generic theoretical suggestion that could reconcile present limits with relevant solar X-ray activity. A short outlook of the experimentally expanding solar axion field is given.