Normalized to: D'Arcangelo, O.
[1]
oai:arXiv.org:1208.5483 [pdf] - 1150922
Planck Intermediate Results. IX. Detection of the Galactic haze with
Planck
Planck Collaboration;
Ade, P. A. R.;
Aghanim, N.;
Arnaud, M.;
Ashdown, M.;
Atrio-Barandela, F.;
Aumont, J.;
Baccigalupi, C.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Battaner, E.;
Benabed, K.;
Benoît, A.;
Bernard, J. -P.;
Bersanelli, M.;
Bonaldi, A.;
Bond, J. R.;
Borrill, J.;
Bouchet, F. R.;
Burigana, C.;
Cabella, P.;
Cardoso, J. -F.;
Catalano, A.;
Cayón, L.;
Chary, R. -R.;
Chiang, L. -Y;
Christensen, P. R.;
Clements, D. L.;
Colombo, L. P. L.;
Coulais, A.;
Crill, B. P.;
Cuttaia, F.;
Danese, L.;
D'Arcangelo, O.;
Davis, R. J.;
de Bernardis, P.;
de Gasperis, G.;
de Rosa, A.;
de Zotti, G.;
Delabrouille, J.;
Dickinson, C.;
Diego, J. M.;
Dobler, G.;
Dole, H.;
Donzelli, S.;
Doré, O.;
Dörl, U.;
Douspis, M.;
Dupac, X.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Finelli, F.;
Forni, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Ganga, K.;
Giard, M.;
Giardino, G.;
González-Nuevo, J.;
Górski, K. M.;
Gratton, S.;
Gregorio, A.;
Gruppuso, A.;
Hansen, F. K.;
Harrison, D.;
Helou, G.;
Henrot-Versillé, S.;
Hernández-Monteagudo, C.;
Hildebrandt, S. R.;
Hivon, E.;
Hobson, M.;
Holmes, W. A.;
Hornstrup, A.;
Hovest, W.;
Huffenberger, K. M.;
Jaffe, T. R.;
Jagemann, T.;
Jones, W. C.;
Juvela, M.;
Keihänen, E.;
Knoche, J.;
Knox, L.;
Kunz, M.;
Kurki-Suonio, H.;
Lagache, G.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Lasenby, A.;
Lawrence, C. R.;
Leach, S.;
Leonardi, R.;
Lilje, P. B.;
Linden-Vørnle, M.;
López-Caniego, M.;
Lubin, P. M.;
Macías-Pérez, J. F.;
Maffei, B.;
Maino, D.;
Mandolesi, N.;
Maris, M.;
Martin, P. G.;
Martínez-González, E.;
Masi, S.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Mazzotta, P.;
Meinhold, P. R.;
Melchiorri, A.;
Mendes, L.;
Mennella, A.;
Mitra, S.;
Miville-Deschênes, M. -A.;
Moneti, A.;
Montier, L.;
Morgante, G.;
Munshi, D.;
Murphy, J. A.;
Naselsky, P.;
Natoli, P.;
Nørgaard-Nielsen, H. U.;
Noviello, F.;
Osborne, S.;
Pajot, F.;
Paladini, R.;
Paoletti, D.;
Partridge, B.;
Pearson, T. J.;
Perdereau, O.;
Perrotta, F.;
Piacentini, F.;
Piat, M.;
Pierpaoli, E.;
Pietrobon, D.;
Plaszczynski, S.;
Pointecouteau, E.;
Polenta, G.;
Ponthieu, N.;
Popa, L.;
Poutanen, T.;
Pratt, G. W.;
Prunet, S.;
Puget, J. -L.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Renault, C.;
Ricciardi, S.;
Riller, T.;
Rocha, G.;
Rosset, C.;
Rubiño-Martín, J. A.;
Rusholme, B.;
Sandri, M.;
Savini, G.;
Schaefer, B. M.;
Scott, D.;
Smoot, G. F.;
Stivoli, F.;
Sudiwala, R.;
Suur-Uski, A. -S.;
Sygnet, J. -F.;
Tauber, J. A.;
Terenzi, L.;
Toffolatti, L.;
Tomasi, M.;
Tristram, M.;
Türler, M.;
Umana, G.;
Valenziano, L.;
Van Tent, B.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L. A.;
Wandelt, B. D.;
White, M.;
Yvon, D.;
Zacchei, A.;
Zonca, A.
Submitted: 2012-08-27
Using precise full-sky observations from Planck, and applying several methods
of component separation, we identify and characterize the emission from the
Galactic "haze" at microwave wavelengths. The haze is a distinct component of
diffuse Galactic emission, roughly centered on the Galactic centre, and extends
to |b| ~35 deg in Galactic latitude and |l| ~15 deg in longitude. By combining
the Planck data with observations from the WMAP we are able to determine the
spectrum of this emission to high accuracy, unhindered by the large systematic
biases present in previous analyses. The derived spectrum is consistent with
power-law emission with a spectral index of -2.55 +/- 0.05, thus excluding
free-free emission as the source and instead favouring hard-spectrum
synchrotron radiation from an electron population with a spectrum (number
density per energy) dN/dE ~ E^-2.1. At Galactic latitudes |b|<30 deg, the
microwave haze morphology is consistent with that of the Fermi gamma-ray "haze"
or "bubbles," indicating that we have a multi-wavelength view of a distinct
component of our Galaxy. Given both the very hard spectrum and the extended
nature of the emission, it is highly unlikely that the haze electrons result
from supernova shocks in the Galactic disk. Instead, a new mechanism for
cosmic-ray acceleration in the centre of our Galaxy is implied.
[2]
oai:arXiv.org:1101.2038 [pdf] - 955981
Planck early results. III. First assessment of the Low Frequency
Instrument in-flight performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Curto, A.;
Cuttaia, F.;
Davis, R. J.;
Dick, J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Kurki-Suonio, H.;
Lawrence, C. R.;
Leach, S.;
Leahy, J. P.;
Lowe, S.;
Maino, D.;
Mandolesi, N.;
Maris, M.;
Martínez-González, E.;
Meinhold, P. R.;
Morgante, G.;
Pearson, D.;
Perrotta, F.;
Polenta, G.;
Poutanen, T.;
Sandri, M.;
Seiffert, M. D.;
Suur-Uski, A. -S.;
Tavagnacco, D.;
Terenzi, L.;
Tomasi, M.;
Valiviita, J.;
Villa, F.;
Watson, R.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Baccigalupi, C.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Bartolo, N.;
Battaglia, P.;
Bennett, K.;
Bonaldi, A.;
Bonavera, L.;
Borrill, J.;
Bouchet, F. R.;
Burigana, C.;
Cabella, P.;
Cappellini, B.;
Chen, X.;
Colombo, L.;
Cruz, M.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
de Gasperis, G.;
de Rosa, A.;
de Zotti, G.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Foley, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T. C.;
Génova-Santos, R. T.;
George, D.;
Gómez, F.;
González-Nuevo, J.;
Górski, K. M.;
Gruppuso, A.;
Hansen, F. K.;
Herranz, D.;
Herreros, J. M.;
Hoyland, R. J.;
Hughes, N.;
Jewell, J.;
Jukkala, P.;
Juvela, M.;
Kangaslahti, P.;
Keihänen, E.;
Keskitalo, R.;
Kilpia, V. -H.;
Kisner, T. S.;
Knoche, J.;
Knox, L.;
Laaninen, M.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Leonardi, R.;
León-Tavares, J.;
Leutenegger, P.;
Lilje, P. B.;
López-Caniego, M.;
Lubin, P. M.;
Malaspina, M.;
Marinucci, D.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Melchiorri, A.;
Mendes, L.;
Miccolis, M.;
Migliaccio, M.;
Mitra, S.;
Moss, A.;
Natoli, P.;
Nesti, R.;
Nørgaard-Nielsen, H. U.;
Pagano, L.;
Paladini, R.;
Paoletti, D.;
Partridge, B.;
Pasian, F.;
Pettorino, V.;
Pietrobon, D.;
Pospieszalski, M.;
Prézeau, G.;
Prina, M.;
Procopio, P.;
Puget, J. -L.;
Quercellini, C.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Robbers, G.;
Rocha, G.;
Roddis, N.;
Rubiño-Martín, J. A.;
Savelainen, M.;
Scott, D.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Tauber, J. A.;
Tofani, G.;
Toffolatti, L.;
Tuovinen, J.;
Türler, M.;
Umana, G.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Vittorio, N.;
Wade, L. A.;
Watson, C.;
White, S. D. M.;
Winder, F.
Submitted: 2011-01-11, last modified: 2011-12-19
The scientific performance of the Planck Low Frequency Instrument (LFI) after
one year of in-orbit operation is presented. We describe the main optical
parameters and discuss photometric calibration, white noise sensitivity, and
noise properties. A preliminary evaluation of the impact of the main systematic
effects is presented. For each of the performance parameters, we outline the
methods used to obtain them from the flight data and provide a comparison with
pre-launch ground assessments, which are essentially confirmed in flight.
[3]
oai:arXiv.org:1106.1376 [pdf] - 1077123
Planck Early Results XXVI: Detection with Planck and confirmation by
XMM-Newton of PLCK G266.6-27.3, an exceptionally X-ray luminous and massive
galaxy cluster at z~1
Planck Collaboration;
Aghanim, N.;
Arnaud, M.;
Ashdown, M.;
Atrio-Barandela, F.;
Aumont, J.;
Baccigalupi, C.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Battaner, E.;
Benabed, K.;
Benoît, A.;
Bernard, J. -P.;
Bersanelli, M.;
Bhatia, R.;
Böhringer, H.;
Bonaldi, A.;
Bond, J. R.;
Borgani, S.;
Borrill, J.;
Bouchet, F. R.;
Brown, M. L.;
Burigana, C.;
Cabella, P.;
Cantalupo, C. M.;
Cappellini, B.;
Carvalho, P.;
Catalano, A.;
Cayón, L.;
Chiang, L. -Y;
Chiang, C.;
Chon, G.;
Christensen, P. R.;
Churazov, E.;
Clements, D. L.;
Colafrancesco, S.;
Colombi, S.;
Crill, B. P.;
Cuttaia, F.;
Da Silva, A.;
Dahle, H.;
Danese, L.;
D'Arcangelo, O.;
Davis, R. J.;
de Bernardis, P.;
de Gasperis, G.;
de Zotti, G.;
Delabrouille, J.;
Delouis, J. -M.;
Démoclès, J.;
Désert, F. -X.;
Dickinson, C.;
Diego, J. M.;
Dole, H.;
Donzelli, S.;
Doré, O.;
Douspis, M.;
Dupac, X.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Finelli, F.;
Flores-Cacho, I.;
Forni, O.;
Fosalba, P.;
Frailis, M.;
Franceschi, E.;
Fromenteau, S.;
Galeotta, S.;
Ganga, K.;
Génova-Santos, R. T.;
Giard, M.;
González-Nuevo, J.;
González-Riestra, R.;
Górski, K. M.;
Gregorio, A.;
Gruppuso, A.;
Hansen, F. K.;
Harrison, D.;
Heinämäki, P.;
Hernández-Monteagudo, C.;
Hildebrandt, S. R.;
Hivon, E.;
Hobson, M.;
Hurier, G.;
Jaffe, A. H.;
Jones, W. C.;
Juvela, M.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T. S.;
Kneissl, R.;
Kurki-Suonio, H.;
Lagache, G.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Lasenby, A.;
Lawrence, C. R.;
Jeune, M. Le;
Leach, S.;
Leonardi, R.;
Leroy, C.;
Liddle, A.;
Lilje, P. B.;
López-Caniego, M.;
Luzzi, G.;
Macías-Pérez, J. F.;
Maino, D.;
Mandolesi, N.;
Marleau, F.;
Martínez-González, E.;
Masi, S.;
Matarrese, S.;
Mazzotta, P.;
Meinhold, P. R.;
Melchiorri, A.;
Melin, J. -B.;
Mendes, L.;
Mennella, A.;
Miville-Deschênes, M. -A.;
Moneti, A.;
Montier, L.;
Morgante, G.;
Mortlock, D.;
Munshi, D.;
Naselsky, P.;
Natoli, P.;
Nevalainen, J.;
Nørgaard-Nielsen, H. U.;
Noviello, F.;
Novikov, D.;
Novikov, I.;
O'Dwyer, I. J.;
Osborne, S.;
Paladini, R.;
Pasian, F.;
Patanchon, G.;
Pearson, T. J.;
Perdereau, O.;
Perotto, L.;
Perrotta, F.;
Piacentini, F.;
Pierpaoli, E.;
Piffaretti, R.;
Platania, P.;
Pointecouteau, E.;
Polenta, G.;
Ponthieu, N.;
Popa, L.;
Poutanen, T.;
Pratt, G. W.;
Prézeau, G.;
Prunet, S.;
Puget, J. -L.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Renault, C.;
Ricciardi, S.;
Riller, T.;
Ristorcelli, I.;
Rocha, G.;
Rubiño-Martín, J. A.;
Saar, E.;
Sandri, M.;
Savini, G.;
Schaefer, B. M.;
Scott, D.;
Smoot, G. F.;
Starck, J. -L.;
Sutton, D.;
Sygnet, J. -F.;
Tauber, J. A.;
Terenzi, L.;
Toffolatti, L.;
Tomasi, M.;
Tristram, M.;
Türler, M.;
Valenziano, L.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L. A.;
Wandelt, B. D.;
Weller, J.;
White, S. D. M.;
White, M.;
Yvon, D.;
Zacchei, A.;
Zonca, A.
Submitted: 2011-06-07, last modified: 2011-07-27
We present first results on PLCK G266.6-27.3, a galaxy cluster candidate
detected at a signal-to-noise ratio of 5 in the Planck All Sky survey. An
XMM-Newton validation observation has allowed us to confirm that the candidate
is a bona fide galaxy cluster. With these X-ray data we measure an accurate
redshift, z = 0.94 +/- 0.02, and estimate the cluster mass to be M_500 = (7.8
+/- 0.8)e+14 solar masses. PLCK G266.6-27.3 is an exceptional system: its
luminosity of L_X(0.5-2.0 keV)=(1.4 +/- 0.05)e+45 erg/s, equals that of the two
most luminous known clusters in the z > 0.5 universe, and it is one of the most
massive clusters at z~1. Moreover, unlike the majority of high-redshift
clusters, PLCK G266.6-27.3 appears to be highly relaxed. This observation
confirms Planck's capability of detecting high-redshift, high-mass clusters,
and opens the way to the systematic study of population evolution in the
exponential tail of the mass function.
[4]
oai:arXiv.org:1107.1157 [pdf] - 382247
W-band prototype of platelet feed-horn array for CMB polarisation
measurements
Del Torto, Francesco;
Bersanelli, Marco;
Cavaliere, Francesco;
De Rosa, Adriano;
D'Arcangelo, Ocleto;
Franceschet, Cristian;
Gervasi, Massimo;
Mennella, Aniello;
Pagana, Enrico;
Simonetto, Alessandro;
Tartari, Andrea;
Villa, Fabrizio;
Zannoni, Mario
Submitted: 2011-07-06
We present the design and performance of a 2x2 prototype array of corrugated
feed-horns in W-band. The module is fabricated using a so-called "platelet"
technique by milling Aluminum plates. This technique is suitable for low-cost
and scalable high performance applications. Room temperature Return Loss
measurements show a low (<-30 dB) reflection over a 30% bandwidth with a
maximum matching of -42 dB at 100 GHz for all four antennas. Beam pattern
measurements indicate good repeatability and a low (-25 dB) sidelobe and
crosspolarisation levels. This work is particularly relevant for future Cosmic
Microwave Background polarisation measurements, which require large microwave
cryogenic detector arrays coupled to high performance corrugated feed horns.
[5]
oai:arXiv.org:1101.2022 [pdf] - 1521890
Planck Early Results: The Planck mission
Planck Collaboration;
Ade, P. A. R.;
Aghanim, N.;
Arnaud, M.;
Ashdown, M.;
Aumont, J.;
Baccigalupi, C.;
Baker, M.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Battaner, E.;
Benabed, K.;
Bennett, K.;
Benoît, A.;
Bernard, J. -P.;
Bersanelli, M.;
Bhatia, R.;
Bock, J. J.;
Bonaldi, A.;
Bond, J. R.;
Borrill, J.;
Bouchet, F. R.;
Bradshaw, T.;
Bremer, M.;
Bucher, M.;
Burigana, C.;
Butler, R. C.;
Cabella, P.;
Cantalupo, C. M.;
Cappellini, B.;
Cardoso, J. -F.;
Carr, R.;
Casale, M.;
Catalano, A.;
Cayón, L.;
Challinor, A.;
Chamballu, A.;
Charra, J.;
Chary, R. -R.;
Chiang, L. -Y;
Chiang, C.;
Christensen, P. R.;
Clements, D. L.;
Colombi, S.;
Couchot, F.;
Coulais, A.;
Crill, B. P.;
Crone, G.;
Crook, M.;
Cuttaia, F.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
Davis, R. J.;
de Bernardis, P.;
de Bruin, J.;
de Gasperis, G.;
de Rosa, A.;
de Zotti, G.;
Delabrouille, J.;
Delouis, J. -M.;
Dèsert, F. -X.;
Dick, J.;
Dickinson, C.;
Dolag, K.;
Dole, H.;
Donzelli, S.;
Dorè, O.;
Dörl, U.;
Douspis, M.;
Dupac, X.;
Efstathiou, G.;
Enfllin, T. A.;
Eriksen, H. K.;
Finelli, F.;
Foley, S.;
Forni, O.;
Fosalba, P.;
Frailis, M.;
Franceschi, E.;
Freschi, M.;
Gaier, T. C.;
Galeotta, S.;
Gallegos, J.;
Gandolfo, B.;
Ganga, K.;
Giard, M.;
Giardino, G.;
Gienger, G.;
Giraud-Hèraud, Y.;
González, J.;
González-Nuevo, J.;
Górski, K. M.;
Gratton, S.;
Gregorio, A.;
Gruppuso, A.;
Guyot, G.;
Haissinski, J.;
Hansen, F. K.;
Harrison, D.;
Helou, G.;
Henrot-Versillè, S.;
Hernández-Monteagudo, C.;
Herranz, D.;
Hildebrandt, S. R.;
Hivon, E.;
Hobson, M.;
Holmes, W. A.;
Hornstrup, A.;
Hovest, W.;
Hoyland, R. J.;
Huffenberger, K. M.;
Jaffe, A. H.;
Jagemann, T.;
Jones, W. C.;
Juillet, J. J.;
Juvela, M.;
Kangaslahti, P.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T. S.;
Kneissl, R.;
Knox, L.;
Krassenburg, M.;
Kurki-Suonio, H.;
Lagache, G.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Lange, A. E.;
Lasenby, A.;
Laureijs, R. J.;
Lawrence, C. R.;
Leach, S.;
Leahy, J. P.;
Leonardi, R.;
Leroy, C.;
Lilje, P. B.;
Linden-Vørnle, M.;
López-Caniego, M.;
Lowe, S.;
Lubin, P. M.;
Macìas-Pèrez, J. F.;
Maciaszek, T.;
MacTavish, C. J.;
Maffei, B.;
Maino, D.;
Mandolesi, N.;
Mann, R.;
Maris, M.;
Martìnez-González, E.;
Masi, S.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Mazzotta, P.;
McDonald, A.;
McGehee, P.;
Meinhold, P. R.;
Melchiorri, A.;
Melin, J. -B.;
Mendes, L.;
Mennella, A.;
Mevi, C.;
Miniscalco, R.;
Mitra, S.;
Miville-Deschínes, M. -A.;
Moneti, A.;
Montier, L.;
Morgante, G.;
Morisset, N.;
Mortlock, D.;
Munshi, D.;
Murphy, A.;
Naselsky, P.;
Natoli, P.;
Netterfield, C. B.;
Nørgaard-Nielsen, H. U.;
Noviello, F.;
Novikov, D.;
Novikov, I.;
O'Dwyer, I. J.;
Ortiz, I.;
Osborne, S.;
Osuna, P.;
Oxborrow, C. A.;
Pajot, F.;
Paladini, R.;
Partridge, B.;
Pasian, F.;
Passvogel, T.;
Patanchon, G.;
Pearson, D.;
Pearson, T. J.;
Perdereau, O.;
Perotto, L.;
Perrotta, F.;
Piacentini, F.;
Piat, M.;
Pierpaoli, E.;
Plaszczynski, S.;
Platania, P.;
Pointecouteau, E.;
Polenta, G.;
Ponthieu, N.;
Popa, L.;
Poutanen, T.;
Prèzeau, G.;
Prunet, S.;
Puget, J. -L.;
Rachen, J. P.;
Reach, W. T.;
Rebolo, R.;
Reinecke, M.;
Reix, J. -M.;
Renault, C.;
Ricciardi, S.;
Riller, T.;
Ristorcelli, I.;
Rocha, G.;
Rosset, C.;
Rowan-Robinson, M.;
Rubiñ-Martìn, J. A.;
Rusholme, B.;
Salerno, E.;
Sandri, M.;
Santos, D.;
Savini, G.;
Schaefer, B. M.;
Scott, D.;
Seiffert, M. D.;
Shellard, P.;
Simonetto, A.;
Smoot, G. F.;
Sozzi, C.;
Starck, J. -L.;
Sternberg, J.;
Stivoli, F.;
Stolyarov, V.;
Stompor, R.;
Stringhetti, L.;
Sudiwala, R.;
Sunyaev, R.;
Sygnet, J. -F.;
Tapiador, D.;
Tauber, J. A.;
Tavagnacco, D.;
Taylor, D.;
Terenzi, L.;
Texier, D.;
Toffolatti, L.;
Tomasi, M.;
Torre, J. -P.;
Tristram, M.;
Tuovinen, J.;
Türler, M.;
Tuttlebee, M.;
Umana, G.;
Valenziano, L.;
Valiviita, J.;
Varis, J.;
Vibert, L.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L. A.;
Wandelt, B. D.;
Watson, C.;
White, S. D. M.;
White, M.;
Wilkinson, A.;
Yvon, D.;
Zacchei, A.;
Zonca, A.
Submitted: 2011-01-11, last modified: 2011-06-16
The European Space Agency's Planck satellite was launched on 14 May 2009, and
has been surveying the sky stably and continuously since 13 August 2009. Its
performance is well in line with expectations, and it will continue to gather
scientific data until the end of its cryogenic lifetime. We give an overview of
the history of Planck in its first year of operations, and describe some of the
key performance aspects of the satellite. This paper is part of a package
submitted in conjunction with Planck's Early Release Compact Source Catalogue,
the first data product based on Planck to be released publicly. The package
describes the scientific performance of the Planck payload, and presents
results on a variety of astrophysical topics related to the sources included in
the Catalogue, as well as selected topics on diffuse emission.
[6]
oai:arXiv.org:1011.6363 [pdf] - 280786
Modeling the frequency response of microwave radiometers with QUCS
Zonca, Andrea;
Roucaries, Bastien;
Williams, Brian;
Rubin, Ishai;
D'Arcangelo, Ocleto;
Meinhold, Peter;
Lubin, Philip;
Franceschet, Cristian;
Jahn, Stefan;
Mennella, Aniello;
Bersanelli, Marco
Submitted: 2010-11-29, last modified: 2010-12-20
Characterization of the frequency response of coherent radiometric receivers
is a key element in estimating the flux of astrophysical emissions, since the
measured signal depends on the convolution of the source spectral emission with
the instrument band shape.
Laboratory Radio Frequency (RF) measurements of the instrument bandpass often
require complex test setups and are subject to a number of systematic effects
driven by thermal issues and impedance matching, particularly if cryogenic
operation is involved.
In this paper we present an approach to modeling radiometers bandpasses by
integrating simulations and RF measurements of individual components. This
method is based on QUCS (Quasi Universal Circuit Simulator), an open-source
circuit simulator, which gives the flexibility of choosing among the available
devices, implementing new analytical software models or using measured
S-parameters. Therefore an independent estimate of the instrument bandpass is
achieved using standard individual component measurements and validated
analytical simulations.
In order to automate the process of preparing input data, running simulations
and exporting results we developed the Python package python-qucs and released
it under GNU Public License.
We discuss, as working cases, bandpass response modeling of the COFE and
Planck Low Frequency Instrument (LFI) radiometers and compare results obtained
with QUCS and with a commercial circuit simulator software. The main purpose of
bandpass modeling in COFE is to optimize component matching, while in LFI they
represent the best estimation of frequency response, since end-to-end
measurements were strongly affected by systematic effects.
[7]
oai:arXiv.org:1005.2541 [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument
flight model radiometers
Villa, F.;
Terenzi, L.;
Sandri, M.;
Meinhold, P.;
Poutanen, T.;
Battaglia, P.;
Franceschet, C.;
Hughes, N.;
Laaninen, M.;
Lapolla, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Balasini, M.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Cappellini, B.;
Cavaliere, F.;
Colin, A.;
Colombo, F.;
Davis, R. J.;
De La Fuente, L.;
Edgeley, J.;
Gaier, T.;
Galtress, A.;
Hoyland, R.;
Jukkala, P.;
Kettle, D.;
Kilpia, V-H.;
Lawrence, C. R.;
Lawson, D.;
Leahy, J. P.;
Leutenegger, P.;
Levin, S.;
Maino, D.;
Malaspina, M.;
Mediavilla, A.;
Miccolis, M.;
Pagan, L.;
Pascual, J. P.;
Pasian, F.;
Pecora, M.;
Pospieszalski, M.;
Roddis, N.;
Salmon, M. J.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Sozzi, C.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
[8]
oai:arXiv.org:1001.4653 [pdf] - 33163
Thermal susceptibility of the Planck-LFI receivers
Terenzi, L;
Salmon, M J;
Colin, A;
Mennella, A;
Morgante, G;
Tomasi, M;
Battaglia, P;
Lapolla, M;
Bersanelli, M;
Butler, R C;
Cuttaia, F;
D'Arcangelo, O;
Davis, R;
Franceschet, C;
Galeotta, S;
Gregorio, A;
Hughes, N;
Jukkala, P;
Kettle, D;
Laaninen, M;
Leutenegger, P;
Leonardi, R;
Mandolesi, N;
Maris, M;
Meinhold, P;
Miccolis, M;
Roddis, N;
Sambo, L;
Sandri, M;
Silvestri, R;
Tuovinen, J;
Valenziano, L;
Varis, J;
Villa, F;
Wilkinson, A;
Zonca, A
Submitted: 2010-01-26
This paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst .
This paper describes the impact of the Planck Low Frequency Instrument front
end physical temperature fluctuations on the output signal. The origin of
thermal instabilities in the instrument are discussed, and an analytical model
of their propagation and impact on the receivers signal is described. The
experimental test setup dedicated to evaluate these effects during the
instrument ground calibration is reported together with data analysis methods.
Finally, main results obtained are discussed and compared to the requirements.
[9]
oai:arXiv.org:1001.4659 [pdf] - 33164
Advanced modelling of the Planck-LFI radiometers
Battaglia, P.;
Franceschet, C.;
Zonca, A .;
Bersanelli, M.;
Butler, R. C.;
D'Arcangelo, O.;
Davis, R. J.;
Galeotta, S.;
Guzzi, P.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Leonardi, R.;
Maino, D.;
Mandolesi, N.;
Meinhold, P.;
Mennella, A.;
Platania, P.;
Terenzi, L.;
Tuovinen, J.;
Varis, J.;
Villa, F.;
Wilkinson, A.
Submitted: 2010-01-26
The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70
GHz spectral range on-board the ESA Planck satellite, launched on May 14th,
2009 to observe the cosmic microwave background (CMB) with unprecedented
precision. In this paper we describe the development and validation of a
software model of the LFI pseudo-correlation receivers which enables to
reproduce and predict all the main system parameters of interest as measured at
each of the 44 LFI detectors. These include system total gain, noise
temperature, band-pass response, non-linear response. The LFI Advanced RF Model
(LARFM) has been constructed by using commercial software tools and data of
each radiometer component as measured at single unit level. The LARFM has been
successfully used to reproduce the LFI behavior observed during the LFI
ground-test campaign. The model is an essential element in the database of LFI
data processing center and will be available for any detailed study of
radiometer behaviour during the survey.
[10]
oai:arXiv.org:1001.4711 [pdf] - 33175
The Planck-LFI flight model composite waveguides
D'Arcangelo, O.;
Figini, L.;
Simonetto, A.;
Villa, F.;
Pecora, M.;
Battaglia, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
Garavaglia, S.;
Guzzi, P.;
Mandolesi, N.;
Mennella, A.;
Morgante, G.;
Pagan, L.;
Valenziano, L.
Submitted: 2010-01-26
The Low Frequency Instrument on board the PLANCK satellite is designed to
give the most accurate map ever of the CMB anisotropy of the whole sky over a
broad frequency band spanning 27 to 77 GHz. It is made of an array of 22
pseudo-correlation radiometers, composed of 11 actively cooled (20 K) Front End
Modules (FEMs), and 11 Back End Modules (BEMs) at 300K. The connection between
the two parts is made with rectangular Wave Guides. Considerations of different
nature (thermal, electromagnetic and mechanical), imposed stringent
requirements on the WGs characteristics and drove their design. From the
thermal point of view, the WG should guarantee good insulation between the FEM
and the BEM sections to avoid overloading the cryocooler. On the other hand it
is essential that the signals do not undergo excessive attenuation through the
WG. Finally, given the different positions of the FEM modules behind the focal
surface and the mechanical constraints given by the surrounding structures,
different mechanical designs were necessary. A composite configuration of
Stainless Steel and Copper was selected to satisfy all the requirements. Given
the complex shape and the considerable length (about 1.5-2 m), manufacturing
and testing the WGs was a challenge. This work deals with the development of
the LFI WGs, including the choice of the final configuration and of the
fabrication process. It also describes the testing procedure adopted to fully
characterize these components from the electromagnetic point of view and the
space qualification process they underwent. Results obtained during the test
campaign are reported and compared with the stringent requirements. The
performance of the LFI WGs is in line with requirements, and the WGs were
successfully space qualified.
[11]
oai:arXiv.org:1001.4730 [pdf] - 33178
Level 1 on-ground telemetry handling in Planck LFI
Zacchei, A.;
Frailis, M.;
Maris, M.;
Morisset, N.;
Rohlfs, R.;
Meharga, M.;
Binko, P.;
Turler, M.;
Galeotta, S.;
Gasparo, F.;
Franceschi, E.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Fogliani, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Maino, D.;
Maggio, G.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meinhold, P.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Pasian, F.;
Perrotta, F.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave
Background (CMB) by covering the frequency range 30-70 GHz in three bands. The
primary instrument data source are the temperature samples acquired by the 22
radiometers mounted on the Planck focal plane. Such samples represent the
scientific data of LFI. In addition, the LFI instrument generates the so called
housekeeping data by sampling regularly the on-board sensors and registers. The
housekeeping data provides information on the overall health status of the
instrument and on the scientific data quality. The scientific and housekeeping
data are collected on-board into telemetry packets compliant with the ESA
Packet Telemetry standards. They represent the primary input to the first
processing level of the LFI Data Processing Centre. In this work we show the
software systems which build the LFI Level 1. A real-time assessment system,
based on the ESA SCOS 2000 generic mission control system, has the main purpose
of monitoring the housekeeping parameters of LFI and detect possible anomalies.
A telemetry handler system processes the housekeeping and scientific telemetry
of LFI, generating timelines for each acquisition chain and each housekeeping
parameter. Such timelines represent the main input to the subsequent processing
levels of the LFI DPC. A telemetry quick-look system allows the real-time
visualization of the LFI scientific and housekeeping data, by also calculating
quick statistical functions and fast Fourier transforms. The LFI Level 1 has
been designed to support all the mission phases, from the instrument ground
tests and calibration to the flight operations, and developed according to the
ESA engineering standards.
[12]
oai:arXiv.org:1001.4743 [pdf] - 33184
Design, development and verification of the 30 and 44 GHz front-end
modules for the Planck Low Frequency Instrument
Davis, R. J.;
Wilkinson, A.;
Davies, R. D.;
Winder, W. F.;
Roddis, N.;
Blackhurst, E. J.;
Lawson, D.;
Lowe, S. R.;
Baines, C.;
Butlin, M.;
Galtress, A.;
Shepherd, D.;
Aja, B.;
Artal, E.;
Bersanelli, M.;
Butler, R. C.;
Castelli, C.;
Cuttaia, F.;
D'Arcangelo, O.;
Gaier, T.;
Hoyland, R.;
Kettle, D.;
Leonardi, R.;
Mandolesi, N.;
Mennella, A.;
Meinhold, P.;
Pospieszalski, M.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zonca, A.
Submitted: 2010-01-26
We give a description of the design, construction and testing of the 30 and
44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the
Planck mission to be launched in 2009. The scientific requirements of the
mission determine the performance parameters to be met by the FEMs, including
their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in
which the signal from the sky is compared with a 4-K blackbody load. The Low
Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High
Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel
phase-switch design which gives excellent amplitude and phase match across the
band.
The noise temperature requirements are met within the measurement errors at
the two frequencies. For the most sensitive LNAs, the noise temperature at the
band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively.
For some of the FEMs, the noise temperature is still falling as the ambient
temperature is reduced to 20 K. Stability tests of the FEMs, including a
measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all
critical aspects. The most sensitive LNAs have reached new limits of noise
temperature for HEMTs at their band centres. The FEMs have well-defined linear
polarization characteristcs.
[13]
oai:arXiv.org:1001.4778 [pdf] - 33192
Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit
Valenziano, Luca;
Cuttaia, Francesco;
De Rosa, Adriano;
Terenzi, Luca;
Brighenti, Alberto;
Cazzola, GianPaolo;
Garbesi, Anna;
Mariotti, Sergio;
Orsi, Giordano;
Pagan, Luca;
Cavaliere, Francesco;
Lapini, Roberto;
Biggi, Matteo;
Panagin, Enzo;
Paola, Battaglia;
Butler, Chris;
Bersanelli, Marco;
D'Arcangelo, Ocleto;
Levin, Steve;
Mandolesi, Nazzareno;
Mennella, Aniello;
Morgante, Gianluca;
Morigi, Gabriele;
Sandri, Maura;
Simonetto, Alessandro;
Tomasi, Maurizio;
Villa, Fabrizio;
Frailis, Marco;
Galeotta, Samuele;
Gregorio, Anna;
Leonardi, Rodrigo;
Lowe, Stuart;
Maris, Michele;
Meinhold, Peter;
Mendes, Luis;
Stringhetti, Luca;
Zonca, Andrea;
Zacchei, Andrea
Submitted: 2010-01-26
The LFI radiometers use a pseudo-correlation design where the signal from the
sky is continuously compared with a stable reference signal, provided by a
cryogenic reference load system. The reference unit is composed by small
pyramidal horns, one for each radiometer, 22 in total, facing small absorbing
targets, made of a commercial resin ECCOSORB CR (TM), cooled to approximately
4.5 K. Horns and targets are separated by a small gap to allow thermal
decoupling. Target and horn design is optimized for each of the LFI bands,
centered at 70, 44 and 30 GHz. Pyramidal horns are either machined inside the
radiometer 20K module or connected via external electro-formed bended
waveguides. The requirement of high stability of the reference signal imposed a
careful design for the radiometric and thermal properties of the loads.
Materials used for the manufacturing have been characterized for thermal, RF
and mechanical properties. We describe in this paper the design and the
performance of the reference system.
[14]
oai:arXiv.org:1001.4787 [pdf] - 33194
LFI Radiometric Chain Assembly (RCA) data handling "Rachel"
Malaspina, M.;
Franceschi, E.;
Battaglia, P.;
Binko, P.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Frailis, M.;
Franceschet, C.;
Galeotta, S.;
Gasparo, F.;
Gregorio, A.;
Lapolla, M.;
Leonardi, R.;
Maggio, G.;
Mandolesi, N.;
Manzato, P.;
Maris, M.;
Meharga, M.;
Meinhold, P.;
Morisset, N.;
Pasian, F.;
Perrotta, F.;
Rohlfs, R.;
Sandri, M.;
Tomasi, M.;
Turler, M.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
This paper is part of the Prelaunch status LFI papers published on JINST
(http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221).
Planck's Low Frequency Instrument is an array of 22 pseudo-correlation
radiometers at 30, 44, and 70 GHz. Before integrating the overall array
assembly, a first set of tests has been performed for each radiometer chain
assembly (RCA), consisting of two radiometers. In this paper, we describe
Rachel, a software application which has been purposely developed and used
during the RCA test campaign to carry out both near-realtime on-line data
analysis and data storage (in FITS format) of the raw output from the
radiometric chains.
[15]
oai:arXiv.org:1001.4838 [pdf] - 33213
A systematic approach to the Planck LFI end-to-end test and its
application to the DPC Level 1 pipeline
Frailis, M.;
Maris, M.;
Zacchei, A.;
Morisset, N.;
Rohlfs, R.;
Meharga, M.;
Binko, P.;
Turler, M.;
Galeotta, S.;
Gasparo, F.;
Franceschi, E.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Gregorio, A.;
Lowe, S. R.;
Maggio, G.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Pasian, F.;
Perrotta, F.;
Sandri, M.;
Terenzi, L.;
Tomasi, M.;
Zonca, A.
Submitted: 2010-01-26
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the
handling of the scientific and housekeeping telemetry. It is a critical
component of the Planck ground segment which has to strictly commit to the
project schedule to be ready for the launch and flight operations. In order to
guarantee the quality necessary to achieve the objectives of the Planck
mission, the design and development of the Level 1 software has followed the
ESA Software Engineering Standards. A fundamental step in the software life
cycle is the Verification and Validation of the software. The purpose of this
work is to show an example of procedures, test development and analysis
successfully applied to a key software project of an ESA mission. We present
the end-to-end validation tests performed on the Level 1 of the LFI-DPC, by
detailing the methods used and the results obtained. Different approaches have
been used to test the scientific and housekeeping data processing. Scientific
data processing has been tested by injecting signals with known properties
directly into the acquisition electronics, in order to generate a test dataset
of real telemetry data and reproduce as much as possible nominal conditions.
For the HK telemetry processing, validation software have been developed to
inject known parameter values into a set of real housekeeping packets and
perform a comparison with the corresponding timelines generated by the Level 1.
With the proposed validation and verification procedure, where the on-board and
ground processing are viewed as a single pipeline, we demonstrated that the
scientific and housekeeping processing of the Planck-LFI raw data is correct
and meets the project requirements.
[16]
oai:arXiv.org:1001.4686 [pdf] - 1477095
The PLANCK LFI flight model ortho-mode transducers
D'Arcangelo, O.;
Simonetto, A.;
Figini, L.;
Pagana, E.;
Villa, F.;
Pecora, M.;
Battaglia, P.;
Bersanelli, M.;
Butler, R. C.;
Garavaglia, S.;
Guzzi, P.;
Mandolesi, N.;
Sozzi, C.
Submitted: 2010-01-26
The Low Frequency Instrument (LFI) of the ESA Planck CMB mission is an array
of 22 ultra sensitive pseudocorrelation radiometers working at 30, 44, and 70
GHz. LFI has been calibrated and delivered for integration with the satellite
to the European Space Agency on November 2006. The aim of Planck is to measure
the anisotropy and polarization of the Cosmic Background Radiation with a
sensitivity and angular resolution never reached before over the full sky. LFI
is intrinsically sensitive to polarization thanks to the use of Ortho-Mode
Transducers (OMT) located between the feedhorns and the pseudo-correlation
radiometers. The OMTs are microwave passive components that divide the incoming
radiation into two linear orthogonal components. A set of 11 OMTs (2 at 30 GHz,
3 at 44 GHz, and 6 at 70 GHz) were produced and tested. This work describes the
design, development and performance of the eleven Flight Model OMTs of LFI. The
final design was reached after several years of development. At first, Elegant
Bread Board OMTs were produced to investigate the manufacturing technology and
design requirements. Then, a set of 3 Qualification Model (QM) OMTs were
designed, manufactured and tested in order to freeze the design and the
manufacturing technology for the flight units. Finally, the Flight Models were
produced and tested. It is shown that all the OMT units have been accepted for
flight and the electromagnetic performance is at least marginally compliant
with the requirements. Mechanically, the units passed all the thermoelastic
qualification tests after a reworking necessary after the QM campaign.
[17]
oai:arXiv.org:1001.4737 [pdf] - 1937606
Optimization of Planck/LFI on--board data handling
Maris, M.;
Tomasi, M.;
Galeotta, S.;
Miccolis, M.;
Hildebrandt, S.;
Frailis, M.;
Rohlfs, R.;
Morisset, N.;
Zacchei, A.;
Bersanelli, M.;
Binko, P.;
Burigana, C.;
Butler, R. C.;
Cuttaia, F.;
Chulani, H.;
D'Arcangelo, O.;
Fogliani, S.;
Franceschi, E.;
Gasparo, F.;
Gomez, F.;
Gregorio, A.;
Herreros, J. M.;
Leonardi, R.;
Leutenegger, P.;
Maggio, G.;
Maino, D.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meharga, M.;
Meinhold, P.;
Mennella, A.;
Pasian, F.;
Perrotta, F.;
Rebolo, R.;
Turler, M.;
Zonca, A.
Submitted: 2010-01-26
To asses stability against 1/f noise, the Low Frequency Instrument (LFI)
onboard the Planck mission will acquire data at a rate much higher than the
data rate allowed by its telemetry bandwith of 35.5 kbps. The data are
processed by an onboard pipeline, followed onground by a reversing step. This
paper illustrates the LFI scientific onboard processing to fit the allowed
datarate. This is a lossy process tuned by using a set of 5 parameters Naver,
r1, r2, q, O for each of the 44 LFI detectors. The paper quantifies the level
of distortion introduced by the onboard processing, EpsilonQ, as a function of
these parameters. It describes the method of optimizing the onboard processing
chain. The tuning procedure is based on a optimization algorithm applied to
unprocessed and uncompressed raw data provided either by simulations, prelaunch
tests or data taken from LFI operating in diagnostic mode. All the needed
optimization steps are performed by an automated tool, OCA2, which ends with
optimized parameters and produces a set of statistical indicators, among them
the compression rate Cr and EpsilonQ. For Planck/LFI the requirements are Cr =
2.4 and EpsilonQ <= 10% of the rms of the instrumental white noise. To speedup
the process an analytical model is developed that is able to extract most of
the relevant information on EpsilonQ and Cr as a function of the signal
statistics and the processing parameters. This model will be of interest for
the instrument data analysis. The method was applied during ground tests when
the instrument was operating in conditions representative of flight. Optimized
parameters were obtained and the performance has been verified, the required
data rate of 35.5 Kbps has been achieved while keeping EpsilonQ at a level of
3.8% of white noise rms well within the requirements.
[18]
oai:arXiv.org:1001.4589 [pdf] - 33143
Planck-LFI radiometers' spectral response
Zonca, A;
Franceschet, C;
Battaglia, P;
Villa, F;
Mennella, A;
D'Arcangelo, O;
Silvestri, R;
Bersanelli, M;
Artal, E;
Butler, R C;
Cuttaia, F;
Davis, R J;
Galeotta, S;
Hughes, N;
Jukkala, P;
Kilpia, V-H;
Laaninen, M;
Mandolesi, N;
Maris, M;
Mendes, L;
Sandri, M;
Terenzi, L;
Tuovinen, J;
Varis, J;
Wilkinson, A
Submitted: 2010-01-26
The Low Frequency Instrument (LFI) is an array of pseudo-correlation
radiometers on board the Planck satellite, the ESA mission dedicated to
precision measurements of the Cosmic Microwave Background. The LFI covers three
bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central
frequency.
The characterization of the broadband frequency response of each radiometer
is necessary to understand and correct for systematic effects, particularly
those related to foreground residuals and polarization measurements. In this
paper we present the measured band shape of all the LFI channels and discuss
the methods adopted for their estimation. The spectral characterization of each
radiometer was obtained by combining the measured spectral response of
individual units through a dedicated RF model of the LFI receiver scheme.
As a consistency check, we also attempted end-to-end spectral measurements of
the integrated radiometer chain in a cryogenic chamber. However, due to
systematic effects in the measurement setup, only qualitative results were
obtained from these tests. The measured LFI bandpasses exhibit a moderate level
of ripple, compatible with the instrument scientific requirements.
[19]
oai:arXiv.org:1001.4608 [pdf] - 33147
Noise Properties of the Planck-LFI Receivers
Meinhold, P.;
Leonardi, R.;
Aja, B.;
Artal, E.;
Battaglia, P.;
Bersanelli, M.;
Blackhurst, E.;
Butler, C. R.;
Cuevas, L. P.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R.;
de la Fuente, M. L.;
Frailis, M.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gregorio, A.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Leutenegger, P.;
Lowe, S. R.;
Malaspina, M.;
Mandolesi, R.;
Maris, M.;
Martínez-González, E.;
Mendes, L.;
Mennella, A.;
Miccolis, M.;
Morgante, G.;
Roddis, N.;
Sandri, M.;
Seiffert, M.;
Salmón, M.;
Stringhetti, L.;
Poutanen, T.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Varis, J.;
Valenziano, L.;
Villa, F.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) radiometers have been tested
extensively during several dedicated campaigns. The present paper reports the
principal noise properties of the LFI radiometers.
[20]
oai:arXiv.org:1001.4610 [pdf] - 33148
The linearity response of the Planck-LFI flight model receivers
Mennella, A.;
Villa, F.;
Terenzi, L.;
Cuttaia, F.;
Battaglia, P.;
Bersanelli, M.;
Butler, R. C.;
D'Arcangelo, O.;
Artal, E.;
Davis, R.;
Frailis, M.;
Franceschet, C.;
Galeotta, S.;
Gregorio, A.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Kilpiä, V. -H.;
Laaninen, M.;
Lapolla, P. M.;
Leonardi, R.;
Leutenegger, P.;
Lowe, S.;
Mandolesi, N.;
Maris, M.;
Meinhold, P.;
Mendes, L.;
Miccolis, M.;
Morgante, G.;
Roddis, N.;
Sandri, M.;
Silvestri, R.;
Stringhetti, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Zacchei, A.;
Varis, J.;
Wilkinson, A.;
Zonca, A.
Submitted: 2010-01-26
In this paper we discuss the linearity response of the Planck-LFI receivers,
with particular reference to signal compression measured on the 30 and 44 GHz
channels. In the article we discuss the various sources of compression and
present a model that accurately describes data measured during tests performed
with individual radiomeric chains. After discussing test results we present the
best parameter set representing the receiver response and discuss the impact of
non linearity on in-flight calibration, which is shown to be negligible.
[21]
oai:arXiv.org:1001.4633 [pdf] - 33153
Planck LFI flight model feed horns
Villa, F.;
D'Arcangelo, O.;
Pecora, M.;
Figini, L.;
Nesti, R.;
Simonetto, A.;
Sozzi, C.;
Sandri, M.;
Battaglia, P.;
Guzzi, P.;
Bersanelli, M.;
Butler, R. C.;
Mandolesi, N.
Submitted: 2010-01-26
this paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency
Instrument is optically interfaced with the ESA Planck telescope through 11
corrugated feed horns each connected to the Radiometer Chain Assembly (RCA).
This paper describes the design, the manufacturing and the testing of the
flight model feed horns. They have been designed to optimize the LFI optical
interfaces taking into account the tight mechanical requirements imposed by the
Planck focal plane layout. All the eleven units have been successfully tested
and integrated with the Ortho Mode transducers.
[22]
oai:arXiv.org:1001.4642 [pdf] - 33158
Off-line radiometric analysis of Planck/LFI data
Tomasi, M.;
Mennella, A.;
Galeotta, S.;
Lowe, S. R.;
Mendes, L.;
Leonardi, R.;
Villa, F.;
Cappellini, B.;
Gregorio, A.;
Meinhold, P.;
Sandri, M.;
Cuttaia, F.;
Terenzi, L.;
Maris, M.;
Valenziano, L.;
Salmon, M. J.;
Bersanelli, M.;
Binko, P.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Frailis, M.;
Franceschi, E.;
Gasparo, F.;
Maggio, G.;
Maino, D.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meharga, M.;
Morgante, G.;
Morisset, N.;
Pasian, F.;
Perrotta, F.;
Rohlfs, R.;
Turler, M.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) is an array of 22
pseudo-correlation radiometers on-board the Planck satellite to measure
temperature and polarization anisotropies in the Cosmic Microwave Background
(CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the
performances of the LFI, a software suite named LIFE has been developed. Its
aims are to provide a common platform to use for analyzing the results of the
tests performed on the single components of the instrument (RCAs, Radiometric
Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA).
Moreover, its analysis tools are designed to be used during the flight as well
to produce periodic reports on the status of the instrument. The LIFE suite has
been developed using a multi-layered, cross-platform approach. It implements a
number of analysis modules written in RSI IDL, each accessing the data through
a portable and heavily optimized library of functions written in C and C++. One
of the most important features of LIFE is its ability to run the same data
analysis codes both using ground test data and real flight data as input. The
LIFE software suite has been successfully used during the RCA/RAA tests and the
Planck Integrated System Tests. Moreover, the software has also passed the
verification for its in-flight use during the System Operations Verification
Tests, held in October 2008.
[23]
oai:arXiv.org:1001.4648 [pdf] - 33162
Planck-LFI radiometers tuning
Cuttaia, Francesco;
Mennella, Aniello;
Stringhetti, Luca;
Maris, Michele;
Terenzi, Luca;
Tomasi, Maurizio;
Villa, Fabrizio;
Bersanelli, Marco;
Butler, Christopher Reginald;
Cappellini, Benedetta;
Cuevas, Leticia Perez;
D'Arcangelo, Ocleto;
Davis, Richard;
Frailis, Marco;
Franceschet, Cristian;
Franceschi, Enrico;
Gregorio, Anna;
Hoyland, Roger;
Leonardi, Rodrigo;
Lowe, Stuart;
Mandolesi, Nazzareno;
Meinhold, Peter;
Mendes, Luis;
Roddis, Neil;
Sandri, Maura;
Valenziano, Luca;
Wilkinson, Althea;
Zacchei, Andrea;
Zonca, Andrea;
Battaglia, Paola;
De Nardo, Stefania;
Grassi, Stefano;
Lapolla, Marco;
Leutenegger, Paolo;
Miccolis, Maurizio;
Silvestri, Roberto
Submitted: 2010-01-26
"This paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst"
This paper describes the Planck Low Frequency Instrument tuning activities
performed through the ground test campaigns, from Unit to Satellite Levels.
Tuning is key to achieve the best possible instrument performance and tuning
parameters strongly depend on thermal and electrical conditions. For this
reason tuning has been repeated several times during ground tests and it has
been repeated in flight before starting nominal operations. The paper discusses
the tuning philosophy, the activities and the obtained results, highlighting
developments and changes occurred during test campaigns. The paper concludes
with an overview of tuning performed during the satellite cryogenic test
campaign (Summer 2008) and of the plans for the just started in-flight
calibration.
[24]
oai:arXiv.org:1001.4562 [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and
expected scientific performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R. J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Lawrence, C. R.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Meinhold, P.;
Mendes, L.;
Morgante, G.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Valenziano, L.;
Villa, F.;
Zacchei, A.;
Zonca, A.;
Balasini, M.;
Franceschet, C.;
Battaglia, P.;
Lapolla, P. M.;
Leutenegger, P.;
Miccolis, M.;
Pagan, L.;
Silvestri, R.;
Aja, B.;
Artal, E.;
Baldan, G.;
Bastia, P.;
Bernardino, T.;
Boschini, L.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
de La Fuente, L.;
Edgeley, J.;
Falvella, M. C.;
Ferrari, F.;
Fogliani, S.;
Franceschi, E.;
Gaier, T.;
Gomez, F.;
Herreros, J. M.;
Hildebrandt, S.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Lawson, D.;
Leahy, P.;
Levin, S.;
Lilje, P. B.;
Maino, D.;
Malaspina, M.;
Manzato, P.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Pasian, F.;
Pascual, J. P.;
Pecora, M.;
Peres-Cuevas, L.;
Platania, P.;
Pospieszalsky, M.;
Poutanen, T.;
Rebolo, R.;
Roddis, N.;
Salmon, M.;
Seiffert, M.;
Simonetto, A.;
Sozzi, C.;
Tauber, J.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck
Low Frequency Instrument (LFI) measured during the ground cryogenic test
campaign. These parameters characterise the instrument response and constitute
our best pre-launch knowledge of the LFI scientific performance. The LFI shows
excellent $1/f$ stability and rejection of instrumental systematic effects;
measured noise performance shows that LFI is the most sensitive instrument of
its kind. The set of measured calibration parameters will be updated during
flight operations through the end of the mission.
[25]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.
[26]
oai:arXiv.org:1001.2657 [pdf] - 1024642
Planck pre-launch status: the Planck-LFI programme
Mandolesi, N.;
Bersanelli, M.;
Butler, R. C.;
Artal, E.;
Baccigalupi, C.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartelmann, M.;
Bennett, K.;
Bhandari, P.;
Bonaldi, A.;
Borrill, J.;
Bremer, M.;
Burigana, C.;
Bowman, R. C.;
Cabella, P.;
Cantalupo, C.;
Cappellini, B.;
Courvoisier, T.;
Crone, G.;
Cuttaia, F.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
de Gasperis, G.;
De Rosa, A.;
De Troia, G.;
de Zotti, G.;
Dick, J.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Dörl, U.;
Dupac, X.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Frailis, M.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gasparo, F.;
Giardino, G.;
Gomez, F.;
Gonzalez-Nuevo, J.;
Górski, K. M.;
Gregorio, A.;
Gruppuso, A.;
Hansen, F.;
Hell, R.;
Herranz, D.;
Herreros, J. M.;
Hildebrandt, S.;
Hovest, W.;
Hoyland, R.;
Huffenberger, K.;
Janssen, M.;
Jaffe, T.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T.;
Kurki-Suonio, H.;
Lähteenmäki, A.;
Lawrence, C. R.;
Leach, S. M.;
Leahy, J. P.;
Leonardi, R.;
Levin, S.;
Lilje, P. B.;
López-Caniego, M.;
Lowe, S. R.;
Lubin, P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Meinhold, P.;
Melchiorri, A.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Morigi, G.;
Morisset, N.;
Moss, A.;
Nash, A.;
Natoli, P.;
Nesti, R.;
Paine, C.;
Partridge, B.;
Pasian, F.;
Passvogel, T.;
Pearson, D.;
Pérez-Cuevas, L.;
Perrotta, F.;
Polenta, G.;
Popa, L. A.;
Poutanen, T.;
Prezeau, G.;
Prina, M.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Riller, T.;
Rocha, G.;
Roddis, N.;
Rohlfs, R.;
Rubiño-Martin, J. A.;
Salerno, E.;
Sandri, M.;
Scott, D.;
Seiffert, M.;
Silk, J.;
Simonetto, A.;
Smoot, G. F.;
Sozzi, C.;
Sternberg, J.;
Stivoli, F.;
Stringhetti, L.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Türler, M.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L.;
White, M.;
White, S.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-15
This paper provides an overview of the Low Frequency Instrument (LFI)
programme within the ESA Planck mission. The LFI instrument has been developed
to produce high precision maps of the microwave sky at frequencies in the range
27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation
spectrum. The scientific goals are described, ranging from fundamental
cosmology to Galactic and extragalactic astrophysics. The instrument design and
development are outlined, together with the model philosophy and testing
strategy. The instrument is presented in the context of the Planck mission. The
LFI approach to ground and inflight calibration is described. We also describe
the LFI ground segment. We present the results of a number of tests
demonstrating the capability of the LFI data processing centre (DPC) to
properly reduce and analyse LFI flight data, from telemetry information to
calibrated and cleaned time ordered data, sky maps at each frequency (in
temperature and polarization), component emission maps (CMB and diffuse
foregrounds), catalogs for various classes of sources (the Early Release
Compact Source Catalogue and the Final Compact Source Catalogue). The
organization of the LFI consortium is briefly presented as well as the role of
the core team in data analysis and scientific exploitation. All tests carried
out on the LFI flight model demonstrate the excellent performance of the
instrument and its various subunits. The data analysis pipeline has been tested
and its main steps verified. In the first three months after launch, the
commissioning, calibration, performance, and verification phases will be
completed, after which Planck will begin its operational life, in which LFI
will have an integral part.
[27]
oai:arXiv.org:0804.3634 [pdf] - 12010
The White Mountain Polarimeter Telescope and an Upper Limit on CMB
Polarization
Levy, Alan R.;
Leonardi, Rodrigo;
Ansmann, Markus;
Bersanelli, Marco;
Childers, Jeffery;
Cole, Terrence D.;
D'Arcangelo, Ocleto;
Davis, G. Vietor;
Lubin, Philip M.;
Marvil, Joshua;
Meinhold, Peter R.;
Miller, Gerald;
O`Neill, Hugh;
Stavola, Fabrizio;
Stebor, Nathan C.;
Timbie, Peter T.;
van der Heide, Maarten;
Villa, Fabrizio;
Villela, Thyrso;
Williams, Brian D.;
Wuensche, Carlos A.
Submitted: 2008-04-22
The White Mountain Polarimeter (WMPol) is a dedicated ground-based microwave
telescope and receiver system for observing polarization of the Cosmic
Microwave Background. WMPol is located at an altitude of 3880 meters on a
plateau in the White Mountains of Eastern California, USA, at the Barcroft
Facility of the University of California White Mountain Research Station.
Presented here is a description of the instrument and the data collected during
April through October 2004. We set an upper limit on $E$-mode polarization of
14 $\mu\mathrm{K}$ (95% confidence limit) in the multipole range
$170<\ell<240$. This result was obtained with 422 hours of observations of a 3
$\mathrm{deg}^2$ sky area about the North Celestial Pole, using a 42 GHz
polarimeter. This upper limit is consistent with $EE$ polarization predicted
from a standard $\Lambda$-CDM concordance model.
[28]
oai:arXiv.org:astro-ph/0310058 [pdf] - 59721
The Low Frequency Instrument in the ESA Planck mission
Mennella, A.;
Bersanelli, M.;
Cappellini, B.;
Maino, D.;
Platania, P.;
Garavaglia, S.;
Butler, R. C.;
Pasian, N. Mandolesi F.;
D'arcangelo, O.;
Simonetto, A.;
Sozzi, C.
Submitted: 2003-10-02
Measurements of the cosmic microwave background (CMB) allow high precision
observation of the cosmic plasma at redshift z~1100. After the success of the
NASA satellite COBE, that in 1992 provided the first detection of the CMB
anisotropy, results from many ground-based and balloon-borne experiments have
showed a remarkable consistency between different results and provided
quantitative estimates of fundamental cosmological properties. During the
current year the team of the NASA WMAP satellite has released the first
improved full-sky maps of the CMB since COBE, leading to a deeper insight in
the origin and evolution of the Universe. The ESA satellite Planck, scheduled
for launch in 2007, is designed to provide the ultimate measurement of the CMB
temperature anisotropy over the full sky, with an accuracy that will be limited
only by astrophysical foregrounds, and robust detection of polarisation
anisotropy. Planck will observe the sky with two instruments over a wide
spectral band (the Low Frequency Instrument, based on coherent radiometers,
from 30 to 70 GHz and the High Frequency Instrument, based on bolometric
detectors, from 100 to 857 GHz). The mission performances will improve
dramatically the scientific return compared to WMAP. Furthermore the LFI
radiometers (as well as some of the HFI bolometers) are intrinsically sensitive
to polarisation so that by combining the data from different receivers it will
be possible to measure accurately the E mode and to detect the B mode of the
polarisation power spectrum. Planck sensitivity will offer also the possibility
to detect the non-Gaussianities imprinted in the CMB.
[29]
oai:arXiv.org:astro-ph/0307309 [pdf] - 58022
High Performances Corrugated Feed Horns for Space Applications at
Millimetre Wavelengths
Villa, F.;
Sandri, M.;
Mandolesi, N.;
Nesti, R.;
Bersanelli, M.;
Simonetto, A.;
Sozzi, C.;
D'Arcangelo, O.;
Muzzini, V.;
Mennella, A.;
Guzzi, P.;
Radaelli, P.;
Fusi, R.;
Alippi, E.
Submitted: 2003-07-16
We report on the design, fabrication and testing of a set of high performance
corrugated feed horns at 30 GHz, 70 GHz and 100 GHz, built as advanced
prototypes for the Low Frequency Instrument (LFI) of the ESA Planck mission.
The electromagnetic designs include linear (100 GHz) and dual shaped (30 and 70
GHz) profiles. Fabrication has been achieved by direct machining at 30 GHz, and
by electro-formation at higher frequencies. The measured performances on side
lobes and return loss meet the stringent Planck requirements over the large
(20%) instrument bandwidth. Moreover, the advantage in terms of main lobe shape
and side lobes levels of the dual profiled designs has been demonstrated.