Normalized to: D'Andrea, M.
[1]
oai:arXiv.org:1912.06390 [pdf] - 2014523
The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence
Detector
D'Andrea, Matteo;
Macculi, Claudio;
Torrioli, Guido;
Argan, Andrea;
Brienza, Daniele;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Barusso, Lorenzo Ferrari;
Gatti, Flavio;
Rigano, Manuela;
Volpe, Angela;
Battistelli, Elia Stefano
Submitted: 2019-12-13
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed
to reduce the particle background of the instrument and to enable the mission
science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES
network. We have developed the CryoAC Demonstration Model, a prototype aimed to
probe the critical technologies of the detector, i.e. the suspended absorber
with an active area of 1 cm2; the low energy threshold of 20 keV; and the
operation connected to a 50 mK thermal bath with a power dissipation less than
40 nW. Here we report the test performed on the first CryoAC DM sample (namely
the AC-S10 prototype), showing that it is fully compliant with its
requirements.
[2]
oai:arXiv.org:1904.03307 [pdf] - 1863163
Opening the low-background and high-spectral-resolution domain with the
ATHENA large X-ray observatory: Development of the Cryogenic AntiCoincidence
Detector for the X-ray Integral Field Unit
Submitted: 2019-04-05
ATHENA is a large-class ESA mission selected for launch in 2031. It is
designed to address the science theme "The Hot and Energetic Universe",
performing X-ray observations (0.2-12 keV) at the L2 Sun-Earth Lagrangian
point. The X-IFU is one of the two instruments of the payload. It is a
cryogenic spectrometer providing spatially resolved high-resolution
spectroscopy. The core of the instrument is a large array of TES
microcalorimeters, operated at a 50 mK thermal bath. The X-IFU performances
would be strongly degraded by the particle background expected in the L2
environment, thus advanced reduction techniques have been adopted to reduce
this contribution by a factor $\sim$50. This is needed to enable many core
science objectives of the mission. Most of the background reduction ($\sim
80\%$) is achieved thanks to the Cryogenic AntiCoincidence detector (CryoAC), a
4 pixels TES microcalorimeter which will be placed less than 1 mm below the TES
array. The CryoAC is a sort of instrument-inside-the-instrument, with
independent cold and warm electronics and a dedicated data processing chain. To
reach the required particle rejection efficiency ($\sim 98 \%$) it will have a
wide energy band (from 20 keV to $\sim$ 1 MeV) and a low deadtime ($< \sim
2\%$), while respecting several constraints to ensure mechanical, thermal and
electromagnetic compatibility with the TES array. Here I will report my PhD
research activity, which has been focused on the development of the CryoAC
Demonstration Model (DM), a single pixel detector requested by ESA before the
mission adoption. The thesis is divided in two main parts. In the first one I
will mainly present the astrophysical framework of my research, and in the
second one I will focus on the experimental activities carried out towards the
CryoAC DM development.
[3]
oai:arXiv.org:1807.08561 [pdf] - 1720395
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: assessing the
role of the athermal phonons collectors in the AC-S8 prototype
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Corsini, Dario;
Gatti, Flavio;
Torrioli, Guido
Submitted: 2018-07-23
The ATHENA X-ray Observatory is the second large-class mission in the ESA
Cosmic Vision 2015-2025 science programme. One of the two on-board instruments
is the X-IFU, an imaging spectrometer based on a large array of TES
microcalorimeters. To reduce the particle-induced background, the spectrometer
works in combination with a Cryogenic Anticoincidence detector (CryoAC), placed
less than 1 mm below the TES array. The last CryoAC single-pixel prototypes,
namely AC-S7 and AC-S8, are based on large area (1 cm2) Silicon absorbers
sensed by 65 parallel-connected iridium TES. This design has been adopted to
improve the response generated by the athermal phonons, which will be used as
fast anticoincidence flag. The latter sample is featured also with a network of
Aluminum fingers directly connected to the TES, designed to further improve the
athermals collection efficiency. In this paper we will report the main results
obtained with AC-S8, showing that the additional fingers network is able to
increase the energy collected from the athermal part of the pulses (from the 6%
of AC-S7 up to the 26 % with AC-S8). Furthermore, the finger design is able to
prevent the quasiparticle recombination in the aluminum, assuring a fast pulse
rising front (L/R limited). In our road map, the AC-S8 prototype is the last
step before the development of the CryoAC Demonstration Model (DM), which will
be the detector able to demonstrate the critical technologies expected in the
CryoAC development programme.
[4]
oai:arXiv.org:1807.08565 [pdf] - 1720396
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: improvement of
the test setup towards the Demonstration Model
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Corsini, Dario;
Gatti, Flavio;
Torrioli, Guido;
Volpe, Angela
Submitted: 2018-07-23
The ATHENA X-IFU development program foresees to build and characterize an
instrument Demonstration Model (DM), in order to probe the system critical
technologies before the mission adoption. In this respect, we are now
developing the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC),
which will be delivered to the Focal Plane Assembly (FPA) development team for
the integration with the TES array. Before the delivery, we will characterize
and test the CryoAC DM in our CryoLab at INAF/IAPS. In this paper we report the
main results of the activities performed to improve our cryogenic test setup,
making it suitable for the DM integration. These activities mainly consist in
the development of a mechanichal setup and a cryogenic magnetic shielding
system, whose effectiveness has been assessed by FEM simulations and a
measurement at warm. The preliminary performance test has been performed by
means of the last CryoAC single pixel prototype, the AC-S8 pre-DM sample.
[5]
oai:arXiv.org:1807.02344 [pdf] - 1714361
The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary
test of AC-S9 towards the Demonstration Model
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Ceriale, Valentina;
Gallucci, Giovanni;
Gatti, Flavio;
Torrioli, Guido;
Volpe, Angela
Submitted: 2018-07-06, last modified: 2018-07-11
Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the
ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector,
which will be placed less than 1 mm below the main TES array detector. We are
now producing the CryoAC Demonstration Model (DM): a single pixel prototype
able to probe the detector critical technologies, i.e. the operation at 50 mK
thermal bath, the threshold energy at 20 keV and the reproducibility of the
thermal conductance between the suspended absorber and the thermal bath. This
detector will be integrated and tested in our cryogenic setup at INAF/IAPS, and
then delivered to SRON for the integration in the X-IFU Focal Plane Assemby
(FPA) DM.
In this paper we report the status of the CryoAC DM development, showing the
main result obtained with the last developed prototype, namely AC-S9. This is a
DM-like sample, which we have preliminary integrated and tested before
performing the final etching process to suspend the silicon absorber. The
results are promising for the DM, since despite the limitations due to the
absence of the final etching (high thermal capacity, high thermal conductance,
partial TES surface coverage), we have been able to operate the detector with
TB = 50 mK and to detect 6 keV photons, thus having a low energy threshold
fully compatible with our requirement (20 keV).
[6]
oai:arXiv.org:1705.07004 [pdf] - 1583644
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: a scientific
assessment of the observational capabilities in the hard X-ray band
Submitted: 2017-05-19
ATHENA is a large X-ray observatory, planned to be launched by ESA in 2028
towards an L2 orbit. One of the two instruments of the payload is the X-IFU: a
cryogenic spectrometer based on a large array of TES microcalorimeters, able to
perform integral field spectrography in the 0.2-12 keV band (2.5 eV FWHM at 6
keV). The X-IFU sensitivity is highly degraded by the particle background
expected in the L2 orbit, which is induced by primary protons of both galactic
and solar origin, and mostly by secondary electrons. To reduce the particle
background level and enable the mission science goals, the instrument
incorporates a Cryogenic AntiCoincidence detector (CryoAC). It is a 4 pixel TES
based detector, placed <1 mm below the main array. In this paper we report a
scientific assessment of the CryoAC observational capabilities in the hard
X-ray band (E>10 keV). The aim of the study has been to understand if the
present detector design can be improved in order to enlarge the X-IFU
scientific capability on an energy band wider than the TES array. This is
beyond the CryoAC baseline, being this instrument aimed to operate as
anticoincidence particle detector and not conceived to perform X-ray
observations.
[7]
oai:arXiv.org:1705.04076 [pdf] - 1583329
The particle background of the X-IFU instrument
Submitted: 2017-05-11
In this paper we are going to review the latest estimates for the particle
background expected on the X-IFU instrument onboard of the ATHENA mission. The
particle background is induced by two different particle populations: the so
called "soft protons" and the Cosmic rays. The first component is composed of
low energy particles (< 100s keV) that get funnelled by the mirrors towards the
focal plane, losing part of their energy inside the filters and inducing
background counts inside the instrument sensitivity band. The latter component
is induced by high energy particles (> 100 MeV) that possess enough energy to
cross the spacecraft and reach the detector from any direction, depositing a
small fraction of their energy inside the instrument. Both these components are
estimated using Monte Carlo simulations and the latest results are presented
here.
[8]
oai:arXiv.org:1704.08498 [pdf] - 1569386
Updates on the background estimates for the X-IFU instrument onboard of
the ATHENA mission
Lotti, Simone;
Macculi, Claudio;
D'Andrea, Matteo;
Piro, Luigi;
Molendi, Silvano;
Gastaldello, Fabio;
Mineo, Teresa;
D'Ai, Antonino;
Bulgarelli, Andrea;
Fioretti, Valentina;
Jacquey, Christian;
Laurenza, Monica;
Laurent, Philippe
Submitted: 2017-04-27
ATHENA, with a launch foreseen in 2028 towards the L2 orbit, addresses the
science theme "The Hot and Energetic Universe", coupling a high-performance
X-ray Telescope with two complementary focal-plane instruments. One of these,
the X-ray Integral Field Unit (X-IFU) is a TES based kilo-pixel array providing
spatially resolved high-resolution spectroscopy (2.5 eV at 6 keV) over a 5
arcmin FoV. The background for this kind of detectors accounts for several
components: the diffuse Cosmic X-ray Background, the low energy particles
(<~100 keV) focalized by the mirrors and reaching the detector from inside the
field of view, and the high energy particles (>~100 MeV) crossing the
spacecraft and reaching the focal plane from every direction. Each one of these
components is under study to reduce their impact on the instrumental
performances. This task is particularly challenging, given the lack of data on
the background of X-ray detectors in L2, the uncertainties on the particle
environment to be expected in such orbit, and the reliability of the models
used in the Monte Carlo background computations. As a consequence, the
activities addressed by the group range from the reanalysis of the data of
previous missions like XMM-Newton, to the characterization of the L2
environment by data analysis of the particle monitors onboard of satellites
present in the Earth magnetotail, to the characterization of solar events and
their occurrence, and to the validation of the physical models involved in the
Monte Carlo simulations. All these activities will allow to develop a set of
reliable simulations to predict, analyze and find effective solutions to reduce
the particle background experienced by the X-IFU, ultimately satisfying the
scientific requirement that enables the science of ATHENA. While the activities
are still ongoing, we present here some preliminary results already obtained by
the group.
[9]
oai:arXiv.org:astro-ph/0001463 [pdf] - 34260
Gravitational waves emitted by extrasolar planetary systems
Submitted: 2000-01-26, last modified: 2000-11-30
In this paper we consider the Extra-solar Planetary Systems recently
discovered in our Galaxy as potential sources of gravitational waves. We
estimate the frequency and characteristic amplitude of the radiation they emit
due to the orbital motion, using the quadrupole formalism. In addition, we
check whether the conditions needed for the resonant excitation of the f- and
g-modes of the central star can be fulfilled. By a Roche-lobe analysis, we show
that there could exist systems in which the low-order g-modes could be excited,
although this does not happen in the systems discovered up to now.