sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Curioni, A.

Normalized to: Curioni, A.

19 article(s) in total. 302 co-authors, from 1 to 10 common article(s). Median position in authors list is 3,0.

[1]  oai:arXiv.org:1310.8214  [pdf] - 795009
First results from the LUX dark matter experiment at the Sanford Underground Research Facility
Comments: Accepted by Phys. Rev. Lett. Appendix A included as supplementary material with PRL article
Submitted: 2013-10-30, last modified: 2014-02-05
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33 GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.
[2]  oai:arXiv.org:1207.3665  [pdf] - 1124847
The LUX Prototype Detector: Heat Exchanger Development
Comments: 12 pages, 9 figures
Submitted: 2012-07-16, last modified: 2013-01-20
The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for achieving robust discrimination of signal from background events. In this paper we describe the development of a novel purification system deployed in a prototype detector. The results from the operation of this prototype indicated heat exchange with an efficiency above 94% up to a flow rate of 42 slpm, allowing for an electron drift length greater than 1 meter to be achieved in approximately two days and sustained for the duration of the testing period.
[3]  oai:arXiv.org:1110.0103  [pdf] - 967104
After LUX: The LZ Program
Comments: Conference proceedings from APS DPF 2011. 9 pages, 6 figures
Submitted: 2011-10-01, last modified: 2011-10-13
The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In particular, the technology used for cryogenics and electrical feedthroughs, circulation and purification, low-background materials and shielding techniques, electronics, calibrations, and automated control and recovery systems are all directly scalable from LUX to the LZ detectors. Extensive searches for potential background sources have been performed, with an emphasis on previously undiscovered background sources that may have a significant impact on tonne-scale detectors. The LZ detectors will probe spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV WIMPs, which represents the ultimate limit for dark matter detection with liquid xenon technology.
[4]  oai:arXiv.org:1108.1836  [pdf] - 1083296
Data Acquisition and Readout System for the LUX Dark Matter Experiment
Comments:
Submitted: 2011-08-08, last modified: 2011-08-09
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX experiment. Data acquisition systems in rare-event searches must accommodate high rate and large dynamic range during precision calibrations involving radioactive sources, while also delivering low threshold for maximum sensitivity. The LUX DAQ meets these challenges using real-time baseline sup- pression that allows for a maximum event acquisition rate in excess of 1.5 kHz with virtually no deadtime. This paper describes the LUX DAQ and the novel acquisition techniques employed in the LUX experiment.
[5]  oai:arXiv.org:1006.5335  [pdf] - 297292
The ArDM experiment
Comments: Proceedings of the Epiphany 2010 Conference, to be published in Acta Physica Polonica B
Submitted: 2010-06-28
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, including a 3 l prototype developed to test the charge readout system.
[6]  oai:arXiv.org:0909.1063  [pdf] - 142221
Scintillation efficiency and ionization yield of liquid xenon for mono-energetic nuclear recoils down to 4 keV
Comments: 10 pages, 15 figures On version v4 we describe in more detail the trigger setup and have edited several figure to help the reader understand them
Submitted: 2009-09-05, last modified: 2010-01-18
Liquid Xenon (LXe) is an excellent material for experiments designed to detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs). A low energy detection threshold is essential for a sensitive WIMP search. The understanding of the relative scintillation efficiency (Leff) and ionization yield of low energy nuclear recoils in LXe is limited for energies below 10 keV. In this paper, we present new measurements that extend the energy down to 4 keV, finding that Leff decreases with decreasing energy. We also measure the quenching of scintillation efficiency due to the electric field in LXe, finding no significant field dependence.
[7]  oai:arXiv.org:1001.0077  [pdf] - 32338
The LAGUNA design study- towards giant liquid based underground detectors for neutrino physics and astrophysics and proton decay searches
LAGUNA Collaboration; Angus, D.; Ariga, A.; Autiero, D.; Apostu, A.; Badertscher, A.; Bennet, T.; Bertola, G.; Bertola, P. F.; Besida, O.; Bettini, A.; Booth, C.; Borne, J. L.; Brancus, I.; Bujakowsky, W.; Campagne, J. E.; Danil, G. Cata; Chipesiu, F.; Chorowski, M.; Cripps, J.; Curioni, A.; Davidson, S.; Declais, Y.; Drost, U.; Duliu, O.; Dumarchez, J.; Enqvist, T.; Ereditato, A.; von Feilitzsch, F.; Fynbo, H.; Gamble, T.; Galvanin, G.; Gendotti, A.; Gizicki, W.; Goger-Neff, M.; Grasslin, U.; Gurney, D.; Hakala, M.; Hannestad, S.; Haworth, M.; Horikawa, S.; Jipa, A.; Juget, F.; Kalliokoski, T.; Katsanevas, S.; Keen, M.; Kisiel, J.; Kreslo, I.; Kudryastev, V.; Kuusiniemi, P.; Labarga, L.; Lachenmaier, T.; Lanfranchi, J. C.; Lazanu, I.; Lewke, T.; Loo, K.; Lightfoot, P.; Lindner, M.; Longhin, A.; Maalampi, J.; Marafini, M.; Marchionni, A.; Margineanu, R. M.; Markiewicz, A.; Marrodan-Undagoita, T.; Marteau, J. E.; Matikainen, R.; Meindl, Q.; Messina, M.; Mietelski, J. W.; Mitrica, B.; Mordasini, A.; Mosca, L.; Moser, U.; Nuijten, G.; Oberauer, L.; Oprina, A.; Paling, S.; Pascoli, S.; Patzak, T.; Pectu, M.; Pilecki, Z.; Piquemal, F.; Potzel, W.; Pytel, W.; Raczynski, M.; Rafflet, G.; Ristaino, G.; Robinson, M.; Rogers, R.; Roinisto, J.; Romana, M.; Rondio, E.; Rossi, B.; Rubbia, A.; Sadecki, Z.; Saenz, C.; Saftoiu, A.; Salmelainen, J.; Sima, O.; Slizowski, J.; Slizowski, K.; Sobczyk, J.; Spooner, N.; Stoica, S.; Suhonen, J.; Sulej, R.; Szarska, M.; Szeglowski, T.; Temussi, M.; Thompson, J.; Thompson, L.; Trzaska, W. H.; Tippmann, M.; Tonazzo, A.; Urbanczyk, K.; Vasseur, G.; Williams, A.; Winter, J.; Wojutszewska, K.; Wurm, M.; Zalewska, A.; Zampaolo, M.; Zito, M.
Comments: 5 pages, contribution to the Workshop "European Strategy for Future Neutrino Physics", CERN, Oct. 2009
Submitted: 2009-12-30
The feasibility of a next generation neutrino observatory in Europe is being considered within the LAGUNA design study. To accommodate giant neutrino detectors and shield them from cosmic rays, a new very large underground infrastructure is required. Seven potential candidate sites in different parts of Europe and at several distances from CERN are being studied: Boulby (UK), Canfranc (Spain), Fr\'ejus (France/Italy), Pyh\"asalmi (Finland), Polkowice-Sieroszowice (Poland), Slanic (Romania) and Umbria (Italy). The design study aims at the comprehensive and coordinated technical assessment of each site, at a coherent cost estimation, and at a prioritization of the sites within the summer 2010.
[8]  oai:arXiv.org:0912.0482  [pdf] - 902613
Status of the LUX Dark Matter Search
Comments: 4 pages, in proceedings of the SUSY09 conference
Submitted: 2009-12-02
The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within various timeframes ranging from 1 year to 5 years or more.
[9]  oai:arXiv.org:physics/0702078  [pdf] - 119207
A Study of the LXeGRIT Detection Efficiency for MeV Gamma-Rays during the 2000 Balloon Flight Campaign
Comments: 20 pages, 15 figures; submitted to NIMA
Submitted: 2007-02-09
LXeGRIT - Liquid Xenon Gamma-Ray Imaging Telescope - is the first prototype of a Compton telescope for \MeV \g-ray astrophysics based on a LXe time projection chamber. One of the most relevant figures of merit for a Compton telescope is the detection efficiency for \g-rays, which depends on diverse contributions such as detector geometry and passive materials, trigger efficiency, dead time, etc. A detailed study of the efficiency of the LXeGRIT instrument, based both on laboratory measurements and Monte Carlo simulations, is presented in this paper.
[10]  oai:arXiv.org:astro-ph/0402596  [pdf] - 63110
Can a simple instrument measure polarization in gamma-ray bursts?
Comments: 13 pages, 3 figures
Submitted: 2004-02-25
The recent claim of a high degree of linear polarization in the prompt gamma-ray burst (GRB) emission of GRB 021206 might have important implications for the underlying mechanism ultimately responsible for the GRB radiation. While the claim itself remains controversial, a full characterization of the GRB polarization has become a scientific imperative. A review of past and present polarimetry missions motivates a set of guidelines for future dedicated GRB polarization experiments. It is also argued that polarization in GRBs could be measured by a relatively simple instrument using readily available technology.
[11]  oai:arXiv.org:hep-ex/0306040  [pdf] - 113355
Detection of partial polarization in Compton scattered photons
Comments: 7 pages, 3 figures
Submitted: 2003-06-18
It has been recently proposed (Boggs, Nucl. Instr. and Meth. A 503 (2003) 562), to use polarization of Compton scattered gamma-rays to improve the imaging performance of Compton telescopes. Building upon that work, we detected the aforementioned polarization in a sample of 1.836 MeV gamma-rays from the LXeGRIT Compton telescope. Here we present the measurement, together with detector oriented considerations on the application of the principle to a realistic Compton telescope.
[12]  oai:arXiv.org:astro-ph/0212005  [pdf] - 53395
The LXeGRIT Compton Telescope Prototype: Current Status and Future Prospects
Comments: 13 pages, 11 figures, SPIE 2002 Proceedings, Conf. Vol. 4851 - 140; corrected references
Submitted: 2002-11-30, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel concept of Compton telescope, based on the complete 3-dimensional reconstruction of the sequence of interactions of individual gamma rays in one position sensitive detector. This balloon-borne telescope consists of an unshielded time projection chamber with an active volume of 400 cm$^2 \times 7$ cm filled with high purity liquid xenon. Four VUV PMTs detect the fast xenon scintillation light signal, providing the event trigger. 124 wires and 4 anodes detect the ionization signals, providing the event spatial coordinates and total energy. In the period 1999 -- 2001, LXeGRIT has been extensively tested both in the laboratory and at balloon altitude, and its response in the MeV region has been thoroughly characterized. Here we summarize some of the results on pre-flight calibration, event reconstruction techniques, and performance during a 27 hour balloon flight on October 4 -- 5. We further present briefly the on-going efforts directed to improve the performance of this prototype towards the requirements for a base module of a next-generation Compton telescope.
[13]  oai:arXiv.org:astro-ph/0211584  [pdf] - 53319
On the Background Rate in the LXeGRIT Instrument during the 2000 Balloon Flight
Comments: 13 pages, 12 figures, SPIE 2002 Proceedings, Conf. Vol. 4851 - 151; corrected references
Submitted: 2002-11-26, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel Compton telescope for MeV gamma-ray astrophysics based on a Liquid Xenon Time Projection Chamber (LXeTPC), sensitive in the energy band of 0.15-10 MeV. In this homogeneous, 3D position sensitive detector, gamma rays with at least two interactions in the sensitive volume of 2800 cm$^{3}$, are imaged as in a standard Compton telescope. Gamma-rays with a single interaction cannot be imaged and constitute a background which can be easily identified and rejected. Charged particles and localized beta-particles background is also easily suppressed based on the TPC localization capability with millimeter resolution. A measurement of the total gamma-ray background rate in near space conditions and the background rejection power of the LXeTPC was a primary goal of the LXeGRIT balloon flight program. We present here a preliminary analysis addressing this question, based on balloon flight data acquired during the Oct 4-5, 2000 LXeGRIT balloon flight from Ft. Sumner, NM. In this long duration (27 hr) balloon experiment, the LXeGRIT TPC was not surrounded by any gamma-ray or charged particle shield. Single site events and charged particles were mostly rejected on-line at the first and second trigger level. The remaining count rate of single-site \g-ray events, at an average atmospheric depth of 3.2 g cm$^{-2}$, is consistent with that expected from atmospheric and diffuse gamma-ray background, taking into account the instrument mass model and response.
[14]  oai:arXiv.org:astro-ph/0207670  [pdf] - 1591929
XENON: a 1 tonne Liquid Xenon Experiment for a Sensitive Dark Matter Search
Comments: 14 pages, 6 figures, submitted to proceedings of the International Workshop on Techniques and Applications of Xenon Detectors (Xenon01), ICRR, Univ. of Tokyo, Kashiwa, Japan, held December 2001 (World Scientific)
Submitted: 2002-07-31
XENON is a novel liquid xenon experiment concept for a sensitive dark matter search using a 1-tonne active target, distributed in an array of ten independent time projection chambers. The design relies on the simultaneous detection of ionization and scintillation signals in liquid xenon, with the goal of extracting as much information as possible on an event-by-event basis, while maintaining most of the target active. XENON is expected to have effective and redundant background identification and discrimination power, higher than 99.5%, and to achieve a very low threshold, on the order of 4 keV visible recoil energy. Based on this expectation and the 1-tonne mass of active xenon, we project a sensitivity of 0.0001 events/kg/day, after 3 yr operation in an appropriate underground location. The XENON experiment has been recently proposed to the National Science Foundation (NSF) for an initial development phase leading to the development of the 100 kg unit module.
[15]  oai:arXiv.org:astro-ph/0012398  [pdf] - 1232610
Preliminary Results from the 1999 Balloon Flight of the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)
Comments: 16 pages, 15 figures; To appear in: X-Ray and Gamma-Ray Instrumentation for Astronomy XI, 2000; Proc. SPIE, vol. 4140; K.A. Flanagan & O.H. Siegmund, eds
Submitted: 2000-12-18
LXeGRIT is a balloon-borne Compton telescope employing a large volume liquid xenon time projection chamber (LXeTPC) as the central gamma-ray detector. It is designed to image gamma rays in the energy range of 200 keV to 20 MeV, with an angular resolution of about 3 degrees (1 sigma) at 2 MeV, within a field-of-view (FOV) of about 1 sr. The detector's energy and three-dimensional spatial resolution as measured during pre-flight calibration experiments, are $\Delta E_\mathrm{lxe}/E=8.8% : \sqrt{1\MeV /E}$ and < 1mm RMS, respectively. The detection efficiency for Compton events varies between 1.5% and 4% depending on energy and event selection. We describe the instrument as flown on May 7, 1999 and review its overall performance at balloon altitude. The launch occurred at 13:26:54 UT from Ft. Sumner, New Mexico and the flight was terminated about 9 hours later. The Crab was in the instrument FOV for a few hours. Analysis of these data is in progress.
[16]  oai:arXiv.org:astro-ph/0012395  [pdf] - 39984
Performance of the Light Trigger System in the Liquid Xenon Gamma-Ray Telescope LXeGRIT
Comments: Submitted to IEEE Trans. on Nuc. Sci., 7 pages, 11 figures
Submitted: 2000-12-18
LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics, based on a liquid xenon time projection chamber with charge and light readout. The energy and direction of an incident gamma-ray is reconstructed from the three-dimensional locations and energy deposits of individual interactions taking place in the homogeneous detector volume. While the charge signals provide energy information and X-Y positions, the fast xenon scintillation light signal is used to trigger the detector. The drift time measurement, referred to the time of the trigger signal, gives the Z-position with the known drift velocity. The light is detected by four UV-sensitive photomultiplier tubes (PMTs). The logical OR of the PMT signals triggers the data acquisition system with an efficiency which depends on the event energy and location, as well as on the discriminator thresholds used on the individual PMTs. Results from experiments with a tagged 22Na source give the spatial distribution of the light trigger efficiency for 511 keV gamma-rays. When averaged over the whole sensitive volume amd all PMTs, the trigger efficiency is 47% or 40% for two discriminator windows used during the LXeGRIT balloon flight of 1999. These values are strongly affected by the different sensitivity of each PMT. The corresponding average efficiency at 511 keV for the best of the four PMTs is in fact 63%, and approaches 100% for interactions taking place in a small volume right above the PMT.
[17]  oai:arXiv.org:astro-ph/0012276  [pdf] - 39865
An Upgraded Data Acquisition System for the Balloon-Borne Liquid Xenon Gamma-Ray Telescope LXeGRIT
Comments: Submitted to IEEE Trans. on Nuc. Sci., 6 pages, 3 figures
Submitted: 2000-12-12, last modified: 2000-12-14
LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics, based on a liquid xenon time projection chamber (LXe-TPC) with charge and light readout. The first balloon flights in 1997 revealed limitations of the trigger electronics and the data acquisition (DAQ) system, leading to their upgrade. New electronics was developed to handle the xenon scintillation light trigger. The original processor module was replaced by a commercial VME processor. The telemetry rate was doubled to 2 x 500 kbps and onboard data storage on hard disks was implemented. Relying on a robust real-time operating system, the new DAQ software adopts an object oriented design to implement the diverse tasks of trigger handling, data selection, transmission, and storage, as well as DAQ control and monitor functions. The new systems performed well during two flights in Spring 1999 and Fall 2000. In the 2000 flight, the DAQ system was able to handle 300-350 triggers/s out of a total of about 650 Hz, including charged particles.
[18]  oai:arXiv.org:astro-ph/0012297  [pdf] - 1232606
Spectroscopy and Imaging Performance of the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)
Comments: To appear in: Hard X-Ray, Gamma-Ray and Neutron Detector Physics XI, 2000; Proc. SPIE, vol. 4140; K.A. Flanagan & O.H. Siegmund, eds
Submitted: 2000-12-13
LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time projection chamber (LXeTPC) for imaging cosmic \g-rays in the energy band of 0.2-20 MeV. The detector, with 400 cm$^2$ area and 7 cm drift gap, is filled with high purity LXe. Both ionization and scintillation light signals are detected to measure the energy deposits and the three spatial coordinates of individual \g -ray interactions within the sensitive volume. The TPC has been characterized with repeated measurements of its spectral and Compton imaging response to \g -rays from radioactive sources such as \na, \cs, \yt and Am-Be. The detector shows a linear response to \g -rays in the energy range 511 keV -4.4 MeV, with an energy resolution (FWHM) of $ \Delta E/E=8.8% \: \sqrt{1\MeV /E}$. Compton imaging of \yt \g -ray events with two detected interactions is consistent with an angular resolution of $\sim$ 3 degrees (RMS) at 1.8 MeV.
[19]  oai:arXiv.org:astro-ph/0012296  [pdf] - 1232605
Compton scattering sequence reconstruction algorithm for the liquid xenon gamma-ray imaging telescope (LXeGRIT)
Comments: To appear in: Hard X-Ray, Gamma-Ray, and Neutron Detector Physics II, 2000; Proc. SPIE, vol. 4141; R.B. James & R.C. Schirato, eds
Submitted: 2000-12-13
The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is a balloon born experiment sensitive to \g -rays in the energy band of 0.2-20 MeV. The main detector is a time projection chamber filled with high purity liquid xenon (LXeTPC), in which the three-dimensional location and energy deposit of individual \g -ray interactions are accurately measured in one homogeneous volume. To determine the \g -ray initial direction (Compton imaging), as well as to reject background, the correct sequence of interactions has to be determined. Here we report the development and optimization of an algorithm to reconstruct the Compton scattering sequence and show its performance on Monte Carlo events and LXeGRIT data.