Normalized to: Curioni, A.
[1]
oai:arXiv.org:1310.8214 [pdf] - 795009
First results from the LUX dark matter experiment at the Sanford
Underground Research Facility
LUX Collaboration;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Clark, K.;
Coffey, T.;
Currie, A.;
Curioni, A.;
Dazeley, S.;
de Viveiros, L.;
Dobi, A.;
Dobson, J.;
Dragowsky, E. M.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Flores, C.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C.;
Hanhardt, M.;
Hertel, S. A.;
Horn, M.;
Huang, D. Q.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Knoche, R.;
Kyre, S.;
Lander, R.;
Larsen, N. A.;
Lee, C.;
Leonard, D. S.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Moongweluwan, M.;
Morad, J.;
Morii, M.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Ott, R. A.;
Pangilinan, M.;
Parker, P. D.;
Pease, E. K.;
Pech, K.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Sofka, C. J.;
Solovov, V. N.;
Sorensen, P.;
Stiegler, T.;
O`Sullivan, K.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Tennyson, B.;
Tiedt, D. R.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
White, D.;
Witherell, M. S.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2013-10-30, last modified: 2014-02-05
The Large Underground Xenon (LUX) experiment, a dual-phase xenon
time-projection chamber operating at the Sanford Underground Research Facility
(Lead, South Dakota), was cooled and filled in February 2013. We report results
of the first WIMP search dataset, taken during the period April to August 2013,
presenting the analysis of 85.3 live-days of data with a fiducial volume of 118
kg. A profile-likelihood analysis technique shows our data to be consistent
with the background-only hypothesis, allowing 90% confidence limits to be set
on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit
on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33
GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass
WIMP signal interpretations of the results from several recent direct detection
experiments.
[2]
oai:arXiv.org:1207.3665 [pdf] - 1124847
The LUX Prototype Detector: Heat Exchanger Development
Akerib, D. S.;
Bai, X.;
Bedikian, S.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Cahn, S.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Curioni, A.;
Dahl, C. E.;
Dazeley, S.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Fiorucci, S.;
Gaitskell, R. J.;
Hall, C.;
Faham, C.;
Holbrook, B.;
Kastens, L.;
Kazkaz, K.;
Kwong, J.;
Lander, R.;
Leonard, D.;
Malling, D.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Morii, M.;
Nikkel, J.;
Phelps, P.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Steigler, T.;
Svoboda, R.;
Sweany, M.;
Thomson, J.;
Tripathi, M.;
Walsh, N.;
Webb, R.;
White, J.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-07-16, last modified: 2013-01-20
The LUX (Large Underground Xenon) detector is a two-phase xenon Time
Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter
interactions. As with all noble element detectors, continuous purification of
the detector medium is essential to produce a large ($>$1ms) electron lifetime;
this is necessary for efficient measurement of the electron signal which in
turn is essential for achieving robust discrimination of signal from background
events. In this paper we describe the development of a novel purification
system deployed in a prototype detector. The results from the operation of this
prototype indicated heat exchange with an efficiency above 94% up to a flow
rate of 42 slpm, allowing for an electron drift length greater than 1 meter to
be achieved in approximately two days and sustained for the duration of the
testing period.
[3]
oai:arXiv.org:1110.0103 [pdf] - 967104
After LUX: The LZ Program
Malling, D. C.;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Coffey, T.;
Curioni, A.;
Currie, A.;
Dazeley, S.;
de Viveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Larsen, N.;
Lee, C.;
Leonard, D.;
Lesko, K.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Majewski, P.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Morii, M.;
Murphy, A. St J.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Thomson, J.;
Tripathi, M.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2011-10-01, last modified: 2011-10-13
The LZ program consists of two stages of direct dark matter searches using
liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the
last stage will be a 20 tonne detector. Both devices will benefit tremendously
from research and development performed for the LUX experiment, a 350 kg liquid
Xe dark matter detector currently operating at the Sanford Underground
Laboratory. In particular, the technology used for cryogenics and electrical
feedthroughs, circulation and purification, low-background materials and
shielding techniques, electronics, calibrations, and automated control and
recovery systems are all directly scalable from LUX to the LZ detectors.
Extensive searches for potential background sources have been performed, with
an emphasis on previously undiscovered background sources that may have a
significant impact on tonne-scale detectors. The LZ detectors will probe
spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV
WIMPs, which represents the ultimate limit for dark matter detection with
liquid xenon technology.
[4]
oai:arXiv.org:1108.1836 [pdf] - 1083296
Data Acquisition and Readout System for the LUX Dark Matter Experiment
Akerib, D. S.;
Bai, X.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Coffey, T.;
Curioni, A.;
Dazeley, S.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Larsen, N.;
Lee, C.;
Leonard, D.;
Lesko, K.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Morii, M.;
Nelson, H.;
Nikkel, J. A.;
Pangilinan, M.;
Phelps, P.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Thomson, J.;
Tripathi, M.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2011-08-08, last modified: 2011-08-09
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to
detect nuclear recoils from interactions with dark matter particles. Signals
from the LUX detector are processed by custom-built analog electronics which
provide properly shaped signals for the trigger and data acquisition (DAQ)
systems. The DAQ is comprised of commercial digitizers with firmware customized
for the LUX experiment. Data acquisition systems in rare-event searches must
accommodate high rate and large dynamic range during precision calibrations
involving radioactive sources, while also delivering low threshold for maximum
sensitivity. The LUX DAQ meets these challenges using real-time baseline sup-
pression that allows for a maximum event acquisition rate in excess of 1.5 kHz
with virtually no deadtime. This paper describes the LUX DAQ and the novel
acquisition techniques employed in the LUX experiment.
[5]
oai:arXiv.org:1006.5335 [pdf] - 297292
The ArDM experiment
ArDM Collaboration;
Amsler, C.;
Badertscher, A.;
Boccone, V.;
Bourgeois, N.;
Bueno, A.;
Carmona-Benitez, M. C.;
Chorowski, M.;
Creus, W.;
Curioni, A.;
Daw, E.;
Degunda, U.;
Dell'Antone, A.;
Droge, M.;
Epprecht, L.;
Haller, C.;
Haranczyk, M.;
Horikawa, S.;
Kaufmann, L.;
Kisiel, J.;
Knecht, L.;
Laffranchi, M.;
Lagoda, J.;
Lazzaro, C.;
Lightfoot, P.;
Lozano, J.;
Lussi, D.;
Maire, G.;
Mania, S.;
Marchionni, A.;
Mavrokoridis, K.;
Melgarejo, A.;
Mijakowski, P.;
Natterer, G.;
Navas-Concha, S.;
Otiougova, P.;
Piotrowska, A.;
Polinski, J.;
de Prado, M.;
Przewlocki, P.;
Ravat, S.;
Regenfus, C.;
Resnati, F.;
Robinson, M.;
Rochet, J.;
Romero, L.;
Rondio, E.;
Rubbia, A.;
Scotto-Lavina, L.;
Spooner, N.;
Viant, T.;
Trawinski, A.;
Ulbricht, J.;
Zalewska, A.
Submitted: 2010-06-28
The aim of the ArDM project is the development and operation of a one ton
double-phase liquid argon detector for direct Dark Matter searches. The
detector measures both the scintillation light and the ionization charge from
ionizing radiation using two independent readout systems. This paper briefly
describes the detector concept and presents preliminary results from the ArDM
R&D program, including a 3 l prototype developed to test the charge readout
system.
[6]
oai:arXiv.org:0909.1063 [pdf] - 142221
Scintillation efficiency and ionization yield of liquid xenon for
mono-energetic nuclear recoils down to 4 keV
Submitted: 2009-09-05, last modified: 2010-01-18
Liquid Xenon (LXe) is an excellent material for experiments designed to
detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs).
A low energy detection threshold is essential for a sensitive WIMP search. The
understanding of the relative scintillation efficiency (Leff) and ionization
yield of low energy nuclear recoils in LXe is limited for energies below 10
keV. In this paper, we present new measurements that extend the energy down to
4 keV, finding that Leff decreases with decreasing energy. We also measure the
quenching of scintillation efficiency due to the electric field in LXe, finding
no significant field dependence.
[7]
oai:arXiv.org:1001.0077 [pdf] - 32338
The LAGUNA design study- towards giant liquid based underground
detectors for neutrino physics and astrophysics and proton decay searches
LAGUNA Collaboration;
Angus, D.;
Ariga, A.;
Autiero, D.;
Apostu, A.;
Badertscher, A.;
Bennet, T.;
Bertola, G.;
Bertola, P. F.;
Besida, O.;
Bettini, A.;
Booth, C.;
Borne, J. L.;
Brancus, I.;
Bujakowsky, W.;
Campagne, J. E.;
Danil, G. Cata;
Chipesiu, F.;
Chorowski, M.;
Cripps, J.;
Curioni, A.;
Davidson, S.;
Declais, Y.;
Drost, U.;
Duliu, O.;
Dumarchez, J.;
Enqvist, T.;
Ereditato, A.;
von Feilitzsch, F.;
Fynbo, H.;
Gamble, T.;
Galvanin, G.;
Gendotti, A.;
Gizicki, W.;
Goger-Neff, M.;
Grasslin, U.;
Gurney, D.;
Hakala, M.;
Hannestad, S.;
Haworth, M.;
Horikawa, S.;
Jipa, A.;
Juget, F.;
Kalliokoski, T.;
Katsanevas, S.;
Keen, M.;
Kisiel, J.;
Kreslo, I.;
Kudryastev, V.;
Kuusiniemi, P.;
Labarga, L.;
Lachenmaier, T.;
Lanfranchi, J. C.;
Lazanu, I.;
Lewke, T.;
Loo, K.;
Lightfoot, P.;
Lindner, M.;
Longhin, A.;
Maalampi, J.;
Marafini, M.;
Marchionni, A.;
Margineanu, R. M.;
Markiewicz, A.;
Marrodan-Undagoita, T.;
Marteau, J. E.;
Matikainen, R.;
Meindl, Q.;
Messina, M.;
Mietelski, J. W.;
Mitrica, B.;
Mordasini, A.;
Mosca, L.;
Moser, U.;
Nuijten, G.;
Oberauer, L.;
Oprina, A.;
Paling, S.;
Pascoli, S.;
Patzak, T.;
Pectu, M.;
Pilecki, Z.;
Piquemal, F.;
Potzel, W.;
Pytel, W.;
Raczynski, M.;
Rafflet, G.;
Ristaino, G.;
Robinson, M.;
Rogers, R.;
Roinisto, J.;
Romana, M.;
Rondio, E.;
Rossi, B.;
Rubbia, A.;
Sadecki, Z.;
Saenz, C.;
Saftoiu, A.;
Salmelainen, J.;
Sima, O.;
Slizowski, J.;
Slizowski, K.;
Sobczyk, J.;
Spooner, N.;
Stoica, S.;
Suhonen, J.;
Sulej, R.;
Szarska, M.;
Szeglowski, T.;
Temussi, M.;
Thompson, J.;
Thompson, L.;
Trzaska, W. H.;
Tippmann, M.;
Tonazzo, A.;
Urbanczyk, K.;
Vasseur, G.;
Williams, A.;
Winter, J.;
Wojutszewska, K.;
Wurm, M.;
Zalewska, A.;
Zampaolo, M.;
Zito, M.
Submitted: 2009-12-30
The feasibility of a next generation neutrino observatory in Europe is being
considered within the LAGUNA design study. To accommodate giant neutrino
detectors and shield them from cosmic rays, a new very large underground
infrastructure is required. Seven potential candidate sites in different parts
of Europe and at several distances from CERN are being studied: Boulby (UK),
Canfranc (Spain), Fr\'ejus (France/Italy), Pyh\"asalmi (Finland),
Polkowice-Sieroszowice (Poland), Slanic (Romania) and Umbria (Italy). The
design study aims at the comprehensive and coordinated technical assessment of
each site, at a coherent cost estimation, and at a prioritization of the sites
within the summer 2010.
[8]
oai:arXiv.org:0912.0482 [pdf] - 902613
Status of the LUX Dark Matter Search
Fiorucci, S.;
Akerib, D. S.;
Bedikian, S.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Carr, D.;
Chapman, J.;
Clark, K.;
Classen, T.;
Curioni, A.;
Dahl, E.;
Dazeley, S.;
de Viveiros, L.;
Druszkiewicz, E.;
Gaitskell, R.;
Hall, C.;
Faham, C. Hernandez;
Holbrook, B.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Lesko, K.;
Malling, D.;
Mannino, R.;
McKinsey, D.;
Mei, D.;
Mock, J.;
Nikkel, J.;
Phelps, P.;
Schroeder, U.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Svoboda, R.;
Sweany, M.;
Thomson, J.;
Toke, J.;
Tripathi, M.;
Walsh, N.;
Webb, R.;
White, J.;
Wolfs, F.;
Woods, M.;
Zhang, C.
Submitted: 2009-12-02
The Large Underground Xenon (LUX) dark matter search experiment is currently
being deployed at the Homestake Laboratory in South Dakota. We will highlight
the main elements of design which make the experiment a very strong competitor
in the field of direct detection, as well as an easily scalable concept. We
will also present its potential reach for supersymmetric dark matter detection,
within various timeframes ranging from 1 year to 5 years or more.
[9]
oai:arXiv.org:physics/0702078 [pdf] - 119207
A Study of the LXeGRIT Detection Efficiency for MeV Gamma-Rays during
the 2000 Balloon Flight Campaign
Submitted: 2007-02-09
LXeGRIT - Liquid Xenon Gamma-Ray Imaging Telescope - is the first prototype
of a Compton telescope for \MeV \g-ray astrophysics based on a LXe time
projection chamber. One of the most relevant figures of merit for a Compton
telescope is the detection efficiency for \g-rays, which depends on diverse
contributions such as detector geometry and passive materials, trigger
efficiency, dead time, etc. A detailed study of the efficiency of the LXeGRIT
instrument, based both on laboratory measurements and Monte Carlo simulations,
is presented in this paper.
[10]
oai:arXiv.org:astro-ph/0402596 [pdf] - 63110
Can a simple instrument measure polarization in gamma-ray bursts?
Submitted: 2004-02-25
The recent claim of a high degree of linear polarization in the prompt
gamma-ray burst (GRB) emission of GRB 021206 might have important implications
for the underlying mechanism ultimately responsible for the GRB radiation.
While the claim itself remains controversial, a full characterization of the
GRB polarization has become a scientific imperative. A review of past and
present polarimetry missions motivates a set of guidelines for future dedicated
GRB polarization experiments. It is also argued that polarization in GRBs could
be measured by a relatively simple instrument using readily available
technology.
[11]
oai:arXiv.org:hep-ex/0306040 [pdf] - 113355
Detection of partial polarization in Compton scattered photons
Submitted: 2003-06-18
It has been recently proposed (Boggs, Nucl. Instr. and Meth. A 503 (2003)
562), to use polarization of Compton scattered gamma-rays to improve the
imaging performance of Compton telescopes. Building upon that work, we detected
the aforementioned polarization in a sample of 1.836 MeV gamma-rays from the
LXeGRIT Compton telescope. Here we present the measurement, together with
detector oriented considerations on the application of the principle to a
realistic Compton telescope.
[12]
oai:arXiv.org:astro-ph/0212005 [pdf] - 53395
The LXeGRIT Compton Telescope Prototype: Current Status and Future
Prospects
Aprile, E.;
Curioni, A.;
Giboni, K. L.;
Kobayashi, M.;
Oberlack, U. G.;
Chupp, E. L.;
Dunphy, P. P.;
Doke, T.;
Kikuchi, J.;
Ventura, S.
Submitted: 2002-11-30, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel concept of Compton telescope, based
on the complete 3-dimensional reconstruction of the sequence of interactions of
individual gamma rays in one position sensitive detector. This balloon-borne
telescope consists of an unshielded time projection chamber with an active
volume of 400 cm$^2 \times 7$ cm filled with high purity liquid xenon. Four VUV
PMTs detect the fast xenon scintillation light signal, providing the event
trigger. 124 wires and 4 anodes detect the ionization signals, providing the
event spatial coordinates and total energy. In the period 1999 -- 2001, LXeGRIT
has been extensively tested both in the laboratory and at balloon altitude, and
its response in the MeV region has been thoroughly characterized. Here we
summarize some of the results on pre-flight calibration, event reconstruction
techniques, and performance during a 27 hour balloon flight on October 4 -- 5.
We further present briefly the on-going efforts directed to improve the
performance of this prototype towards the requirements for a base module of a
next-generation Compton telescope.
[13]
oai:arXiv.org:astro-ph/0211584 [pdf] - 53319
On the Background Rate in the LXeGRIT Instrument during the 2000 Balloon
Flight
Curioni, A.;
Aprile, E.;
Giboni, K. L.;
Kobayashi, M.;
Oberlack, U. G.;
Chupp, E. L.;
Dunphy, P. P.;
Doke, T.;
Kikuchi, J.;
Ventura, S.
Submitted: 2002-11-26, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel Compton telescope for MeV gamma-ray
astrophysics based on a Liquid Xenon Time Projection Chamber (LXeTPC),
sensitive in the energy band of 0.15-10 MeV. In this homogeneous, 3D position
sensitive detector, gamma rays with at least two interactions in the sensitive
volume of 2800 cm$^{3}$, are imaged as in a standard Compton telescope.
Gamma-rays with a single interaction cannot be imaged and constitute a
background which can be easily identified and rejected. Charged particles and
localized beta-particles background is also easily suppressed based on the TPC
localization capability with millimeter resolution. A measurement of the total
gamma-ray background rate in near space conditions and the background rejection
power of the LXeTPC was a primary goal of the LXeGRIT balloon flight program.
We present here a preliminary analysis addressing this question, based on
balloon flight data acquired during the Oct 4-5, 2000 LXeGRIT balloon flight
from Ft. Sumner, NM. In this long duration (27 hr) balloon experiment, the
LXeGRIT TPC was not surrounded by any gamma-ray or charged particle shield.
Single site events and charged particles were mostly rejected on-line at the
first and second trigger level. The remaining count rate of single-site \g-ray
events, at an average atmospheric depth of 3.2 g cm$^{-2}$, is consistent with
that expected from atmospheric and diffuse gamma-ray background, taking into
account the instrument mass model and response.
[14]
oai:arXiv.org:astro-ph/0207670 [pdf] - 1591929
XENON: a 1 tonne Liquid Xenon Experiment for a Sensitive Dark Matter
Search
Aprile, E.;
Baltz, E. A.;
Curioni, A.;
Giboni, K-L.;
Hailey, C. J.;
Hui, L.;
Kobayashi, M.;
Ni, K.;
Craig, W. W.;
Gaitskell, R. J.;
Oberlack, U.;
Shutt, T.
Submitted: 2002-07-31
XENON is a novel liquid xenon experiment concept for a sensitive dark matter
search using a 1-tonne active target, distributed in an array of ten
independent time projection chambers. The design relies on the simultaneous
detection of ionization and scintillation signals in liquid xenon, with the
goal of extracting as much information as possible on an event-by-event basis,
while maintaining most of the target active. XENON is expected to have
effective and redundant background identification and discrimination power,
higher than 99.5%, and to achieve a very low threshold, on the order of 4 keV
visible recoil energy.
Based on this expectation and the 1-tonne mass of active xenon, we project a
sensitivity of 0.0001 events/kg/day, after 3 yr operation in an appropriate
underground location. The XENON experiment has been recently proposed to the
National Science Foundation (NSF) for an initial development phase leading to
the development of the 100 kg unit module.
[15]
oai:arXiv.org:astro-ph/0012398 [pdf] - 1232610
Preliminary Results from the 1999 Balloon Flight of the Liquid Xenon
Gamma-Ray Imaging Telescope (LXeGRIT)
Aprile, E.;
Oberlack, U. G.;
Curioni, A.;
Egorov, V.;
Giboni, K. -L.;
Ventura, ;
S.;
Doke, ;
T.;
Kikuchi, J.;
Takizawa, K.;
Chupp, ;
E. L.;
Dunphy, P. P.
Submitted: 2000-12-18
LXeGRIT is a balloon-borne Compton telescope employing a large volume liquid
xenon time projection chamber (LXeTPC) as the central gamma-ray detector. It is
designed to image gamma rays in the energy range of 200 keV to 20 MeV, with an
angular resolution of about 3 degrees (1 sigma) at 2 MeV, within a
field-of-view (FOV) of about 1 sr. The detector's energy and three-dimensional
spatial resolution as measured during pre-flight calibration experiments, are
$\Delta E_\mathrm{lxe}/E=8.8% : \sqrt{1\MeV /E}$ and < 1mm RMS, respectively.
The detection efficiency for Compton events varies between 1.5% and 4%
depending on energy and event selection. We describe the instrument as flown on
May 7, 1999 and review its overall performance at balloon altitude. The launch
occurred at 13:26:54 UT from Ft. Sumner, New Mexico and the flight was
terminated about 9 hours later. The Crab was in the instrument FOV for a few
hours. Analysis of these data is in progress.
[16]
oai:arXiv.org:astro-ph/0012395 [pdf] - 39984
Performance of the Light Trigger System in the Liquid Xenon Gamma-Ray
Telescope LXeGRIT
Submitted: 2000-12-18
LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics,
based on a liquid xenon time projection chamber with charge and light readout.
The energy and direction of an incident gamma-ray is reconstructed from the
three-dimensional locations and energy deposits of individual interactions
taking place in the homogeneous detector volume. While the charge signals
provide energy information and X-Y positions, the fast xenon scintillation
light signal is used to trigger the detector. The drift time measurement,
referred to the time of the trigger signal, gives the Z-position with the known
drift velocity. The light is detected by four UV-sensitive photomultiplier
tubes (PMTs). The logical OR of the PMT signals triggers the data acquisition
system with an efficiency which depends on the event energy and location, as
well as on the discriminator thresholds used on the individual PMTs. Results
from experiments with a tagged 22Na source give the spatial distribution of the
light trigger efficiency for 511 keV gamma-rays. When averaged over the whole
sensitive volume amd all PMTs, the trigger efficiency is 47% or 40% for two
discriminator windows used during the LXeGRIT balloon flight of 1999. These
values are strongly affected by the different sensitivity of each PMT. The
corresponding average efficiency at 511 keV for the best of the four PMTs is in
fact 63%, and approaches 100% for interactions taking place in a small volume
right above the PMT.
[17]
oai:arXiv.org:astro-ph/0012276 [pdf] - 39865
An Upgraded Data Acquisition System for the Balloon-Borne Liquid Xenon
Gamma-Ray Telescope LXeGRIT
Submitted: 2000-12-12, last modified: 2000-12-14
LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics,
based on a liquid xenon time projection chamber (LXe-TPC) with charge and light
readout. The first balloon flights in 1997 revealed limitations of the trigger
electronics and the data acquisition (DAQ) system, leading to their upgrade.
New electronics was developed to handle the xenon scintillation light trigger.
The original processor module was replaced by a commercial VME processor. The
telemetry rate was doubled to 2 x 500 kbps and onboard data storage on hard
disks was implemented. Relying on a robust real-time operating system, the new
DAQ software adopts an object oriented design to implement the diverse tasks of
trigger handling, data selection, transmission, and storage, as well as DAQ
control and monitor functions. The new systems performed well during two
flights in Spring 1999 and Fall 2000. In the 2000 flight, the DAQ system was
able to handle 300-350 triggers/s out of a total of about 650 Hz, including
charged particles.
[18]
oai:arXiv.org:astro-ph/0012297 [pdf] - 1232606
Spectroscopy and Imaging Performance of the Liquid Xenon Gamma-Ray
Imaging Telescope (LXeGRIT)
Aprile, E.;
Curioni, A.;
Egorov, V.;
Giboni, K. -L.;
Oberlack, U. G.;
Ventura, ;
S.;
Doke, ;
T.;
Kikuchi, J.;
Takizawa, K.;
Chupp, ;
E. L.;
Dunphy, P. P.
Submitted: 2000-12-13
LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time
projection chamber (LXeTPC) for imaging cosmic \g-rays in the energy band of
0.2-20 MeV. The detector, with 400 cm$^2$ area and 7 cm drift gap, is filled
with high purity LXe. Both ionization and scintillation light signals are
detected to measure the energy deposits and the three spatial coordinates of
individual \g -ray interactions within the sensitive volume. The TPC has been
characterized with repeated measurements of its spectral and Compton imaging
response to \g -rays from radioactive sources such as \na, \cs, \yt and Am-Be.
The detector shows a linear response to \g -rays in the energy range 511 keV
-4.4 MeV, with an energy resolution (FWHM) of $ \Delta E/E=8.8% \: \sqrt{1\MeV
/E}$. Compton imaging of \yt \g -ray events with two detected interactions is
consistent with an angular resolution of $\sim$ 3 degrees (RMS) at 1.8 MeV.
[19]
oai:arXiv.org:astro-ph/0012296 [pdf] - 1232605
Compton scattering sequence reconstruction algorithm for the liquid
xenon gamma-ray imaging telescope (LXeGRIT)
Submitted: 2000-12-13
The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is a balloon born
experiment sensitive to \g -rays in the energy band of 0.2-20 MeV. The main
detector is a time projection chamber filled with high purity liquid xenon
(LXeTPC), in which the three-dimensional location and energy deposit of
individual \g -ray interactions are accurately measured in one homogeneous
volume. To determine the \g -ray initial direction (Compton imaging), as well
as to reject background, the correct sequence of interactions has to be
determined. Here we report the development and optimization of an algorithm to
reconstruct the Compton scattering sequence and show its performance on Monte
Carlo events and LXeGRIT data.