Normalized to: Cucchetti, E.
[1]
oai:arXiv.org:1908.00781 [pdf] - 1966924
SIXTE -- The Generic X-ray Instrument Simulation Toolkit
Dauser, Thomas;
Falkner, Sebastian;
Lorenz, Maximilian;
Kirsch, Christian;
Peille, Philippe;
Cucchetti, Edoardo;
Schmid, Christian;
Brand, Thorsten;
Oertel, Mirjam;
Smith, Randall;
Wilms, Jörn
Submitted: 2019-08-02, last modified: 2019-08-08
We give an overview of the SImulation of X-ray TElescopes (SIXTE) software
package, a generic, mission-independent Monte Carlo simulation toolkit for
X-ray astronomical instrumentation. The package is based on a modular approach
for the source definition, the description of the optics, and the detector type
such that new missions can be easily implemented. The targets to be simulated
are stored in a flexible input format called SIMPUT. Based on this source
definition, a sample of photons is produced and then propagated through the
optics. In order to model the detection process, the software toolkit contains
modules for various detector types, ranging from proportional counter and
Si-based detectors, to more complex descriptions like transition edge sensor
(TES) devices. The implementation of characteristic detector effects and a
detailed modeling of the read-out process allow for representative simulations
and therefore enable the analysis of characteristic features, such as for
example pile-up, and their impact on observations. We present an overview of
the implementation of SIXTE from the input source, the imaging, and the
detection process, highlighting the modular approach taken by the SIXTE
software package. In order to demonstrate the capabilities of the simulation
software, we present a selection of representative applications, including the
all-sky survey of eROSITA and a study of pile-up effects comparing the
currently operating XMM-Newton with the planned Athena-WFI instrument. A
simulation of a galaxy cluster with the Athena- X-IFU shows the capability of
SIXTE to predict the expected performance of an observation for a complex
source with a spatially varying spectrum and our current knowledge of the
future instrument.
[2]
oai:arXiv.org:1904.06248 [pdf] - 1966705
Towards mapping turbulence in the intra-cluster medium -- I. Sample
variance in spatially-resolved X-ray line diagnostics
Submitted: 2019-04-12, last modified: 2019-07-24
X-ray observations of galaxy clusters provide insights on the nature of
gaseous turbulent motions, their physical scales and on the fundamental
processes they are related to. Spatially-resolved, high-resolution spectral
measurements of X-ray emission lines provide diagnostics on the nature of
turbulent motions in emitting atmospheres. Since they are acting on scales
comparable to the size of the objects, the uncertainty on these physical
parameters is limited by the number of observational measurements, through
sample variance. We propose a different and complementary approach for the
computation of sample variance to repeating numerical simulations (i.e.
Monte-Carlo sampling) by introducing new analytical developments for lines
diagnosis. We consider the model of a "turbulent gas cloud", consisting in
isotropic and uniform turbulence described by a universal Kolmogorov
power-spectrum with random amplitudes and phases in an optically thin medium.
Following a simple prescription for the 4-term correlation of Fourier
coefficients, we derive generic expressions for the sample mean and variance of
line centroid shift, line broadening and projected velocity structure function.
We perform a numerical validation based on Monte-Carlo simulations for two
popular models of gas emissivity based on the beta-model. Generic expressions
for the sample variance of line centroid shifts and broadening in arbitrary
apertures are derived and match the simulations within their range of
applicability. Generic expressions for the mean and variance of the structure
function are provided and verified against simulations. An application to the
Athena/X-IFU and XRISM/Resolve instruments forecasts the potential of
sensitive, spatially-resolved spectroscopy to probe the inertial range of
turbulent velocity cascades in a Coma-like galaxy cluster.
[3]
oai:arXiv.org:1904.06249 [pdf] - 1966706
Towards mapping turbulence in the intra-cluster medium -- II.
Measurement uncertainties in the estimation of structure functions
Submitted: 2019-04-12, last modified: 2019-06-26
X-ray observations of the hot gas filling the intra-cluster medium provide a
wealth of information on the dynamics of clusters of galaxies. The global
equilibrium of the ICM is believed to be partially ensured by non-thermal
pressure support, notably the dissipation of energy through turbulent motions.
Accurate mapping of turbulence using X-ray emission lines is challenging due to
the lack of spatially-resolved spectroscopy. Only future instruments such as
the X-ray Integral Field Unit (X-IFU) on Athena will have the spatial and
spectral resolution to quantitatively investigate the ICM turbulence at all
scales. Powerful diagnostics for these studies are line shift and the line
broadening maps, and the second-order structure function. When estimating these
quantities, instruments will be limited by uncertainties of their measurements,
and by the sample variance (aka cosmic variance) of the observation. We extend
here the formalism started in our companion paper I to include the effect of
statistical uncertainties in the estimation of these line diagnostics, in
particular for structure functions. We demonstrate that statistics contribute
to the total variance through different terms, which depend on the geometry of
the detector, the spatial binning and the nature of the turbulent field. These
terms are important when probing the small scales of the turbulence. An
application of these equations is performed for the X-IFU, using synthetic
turbulent velocity maps of a Coma-like cluster of galaxies. Results are in
excellent agreement with the formulas both for the structure function
estimation (<3%) and its variance (<10%). The expressions derived here and in
paper I are generic, and ensure an estimation of the total errors in any X-ray
measurement of turbulent structure functions. They also open the way for
optimisations in the upcoming instrumentation and in observational strategies.
[4]
oai:arXiv.org:1903.04597 [pdf] - 1849247
Probing Macro-Scale Gas Motions and Turbulence in Diffuse Cosmic Plasmas
Bulbul, Esra;
Gaspari, Massimo;
Alvarez, Gabriella;
Avestruz, Camille;
Bautz, Mark;
Benson, Brad;
Biffi, Veronica;
Burke, Douglas;
Clerc, Nicolas;
Chadayammuri, Urmila;
Churazov, Eugene;
Cucchetti, Edoardo;
Eckert, Dominique;
Ettori, Stefano;
Forman, Bill;
Gastaldello, Fabio;
Ghirardini, Vittorio;
Kraft, Ralph;
Markevitch, Maxim;
McDonald, Mike;
Miller, Eric;
Mroczkowski, Tony;
Nagai, Daisuke;
Nulsen, Paul;
Pratt, Gabriel W.;
Randall, Scott;
Reiprich, Thomas;
Roncarelli, Mauro;
Simionescu, Aurora;
Smith, Randall;
Tremblay, Grant;
Walker, Stephen;
Zhuravleva, Irina;
ZuHone, John
Submitted: 2019-03-11, last modified: 2019-03-13
Clusters of galaxies, the largest collapsed structures in the Universe, are
located at the intersection of extended filaments of baryons and dark matter.
Cosmological accretion onto clusters through large scale filaments adds
material at cluster outskirts. Kinetic energy in the form of bulk motions and
turbulence due to this accretion provides a form of pressure support against
gravity, supplemental to thermal pressure. Significant amount of non-thermal
pressure support could bias cluster masses derived assuming hydrostatic
equilibrium, the primary proxy for cluster cosmology studies. Sensitive
measurements of Doppler broadening and shift of astrophysical lines, and the
relative fluctuations in thermodynamical quantities (e.g., density, pressure,
and entropy) are primary diagnostic tools. Forthcoming planned and proposed
X-ray (with large etendue, throughput, and high spectral resolution) and SZ
observatories will provide crucial information on the assembly and
virialisation processes of clusters, involving turbulent eddies cascading at
various spatial scales and larger gas bulk motions in their external regions to
the depth or their potential wells.
[5]
oai:arXiv.org:1809.08903 [pdf] - 1799902
Athena X-IFU synthetic observations of galaxy clusters to probe the
chemical enrichment of the Universe
Cucchetti, E.;
Pointecouteau, E.;
Peille, P.;
Clerc, N.;
Rasia, E.;
Biffi, V.;
Borgani, S.;
Tornatore, L.;
Dolag, K.;
Roncarelli, M.;
Gaspari, M.;
Ettori, S.;
Bulbul, E.;
Dauser, T.;
Wilms, J.;
Pajot, F.;
Barret, D.
Submitted: 2018-09-24
Answers to the metal production of the Universe can be found in galaxy
clusters, notably within their Intra-Cluster Medium (ICM). The X-ray Integral
Field Unit (X-IFU) on board the next-generation European X-ray observatory
Athena (2030s) will provide the necessary leap forward in spatially-resolved
spectroscopy required to disentangle the intricate mechanisms responsible for
this chemical enrichment. In this paper, we investigate the future capabilities
of the X-IFU in probing the hot gas within galaxy clusters. From a test sample
of four clusters extracted from cosmological hydrodynamical simulations, we
present comprehensive synthetic observations of these clusters at different
redshifts (up to z = 2) and within the scaled radius R500 performed using the
instrument simulator SIXTE. Through 100 ks exposures, we demonstrate that the
X-IFU will provide spatially-resolved mapping of the ICM physical properties
with little to no biases (<5%) and well within statistical uncertainties. The
detailed study of abundance profiles and abundance ratios within R500 also
highlights the power of the X-IFU in providing constraints on the various
enrichment models. From synthetic observations out to z = 2, we also quantify
its ability to track the chemical elements across cosmic time with excellent
accuracy, and thereby to investigate the evolution of metal production
mechanisms as well as the link to the stellar initial mass-function. Our study
demonstrates the unprecedented capabilities of the X-IFU in unveiling the
properties of the ICM but also stresses the data analysis challenges faced by
future high-resolution X-ray missions such as Athena.
[6]
oai:arXiv.org:1805.02577 [pdf] - 1767421
Measuring turbulence and gas motions in galaxy clusters via synthetic
Athena X-IFU observations
Roncarelli, M.;
Gaspari, M.;
Ettori, S.;
Biffi, V.;
Brighenti, F.;
Bulbul, E.;
Clerc, N.;
Cucchetti, E.;
Pointecouteau, E.;
Rasia, E.
Submitted: 2018-05-07, last modified: 2018-07-18
The X-ray Integral Field Unit (X-IFU) that will be on board the Athena
telescope will provide an unprecedented view of the intracluster medium (ICM)
kinematics through the observation of gas velocity, $v$, and velocity
dispersion, $w$, via centroid-shift and broadening of emission lines,
respectively. The improvement of data quality and quantity requires an
assessment of the systematics associated with this new data analysis, namely
biases, statistical and systematic errors, and possible correlations between
the different measured quantities. We have developed an end-to-end X-IFU
simulator that mimics a full X-ray spectral fitting analysis on a set of mock
event lists, obtained using SIXTE. We have applied it to three hydrodynamical
simulations of a Coma-like cluster that include the injection of turbulence.
This allowed us to assess the ability of X-IFU to map five physical quantities
in the cluster core: emission measure, temperature, metal abundance, velocity
and velocity dispersion. Finally, starting from our measurements maps, we
computed the 2D structure function (SF) of emission measure fluctuations, $v$
and $w$ and compared them with those derived directly from the simulations. All
quantities match with the input projected values without bias; the systematic
errors were below 5%, except for velocity dispersion whose error reaches about
15%. Moreover, all measurements prove to be statistically independent,
indicating the robustness of the fitting method. Most importantly, we recover
the slope of the SFs in the inertial regime with excellent accuracy, but we
observe a systematic excess in the normalization of both SF$_v$ and SF$_w$
ascribed to the simplistic assumption of uniform and (bi-)Gaussian measurement
errors. Our work highlights the excellent capabilities of Athena X-IFU in
probing the thermodynamic and kinematic properties of the ICM. (abridged)
[7]
oai:arXiv.org:1807.06092 [pdf] - 1717296
The Athena X-ray Integral Field Unit
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Cappi, Massimo;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rozanska, Agata;
Wilms, Joern;
Bandler, Simon;
Barbera, Marco;
Barcons, Xavier;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Costantini, Elisa;
Decourchelle, Anne;
Hartog, Roland den;
Duband, Lionel;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Sato, Kosuke;
Schaye, Joop;
Shinozaki, Keisuke;
Thibert, Tanguy;
Valenziano, Luca;
Valette, Veronique;
Vink, Jacco;
Webb, Natalie;
Wise, Michael;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Mesnager, Jean-Michel;
Pontet, Bernard;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Bulbul, Esra;
Dadina, Mauro;
Ettori, Stefano;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Kaastra, Jelle;
Mazzotta, Pasquale;
Miller, Jon;
Miniutti, Giovanni;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Simionescu, Aurora;
Torrejon, Jose Miguel;
Frezouls, Benoît;
Geoffray, Hervé;
Peille, Philippe;
Aicardi, Corinne;
André, Jérôme;
Clénet, Antoine;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hervet, Gilles;
Jolly, Antoine;
Ledot, Aurélien;
Maussang, Irwin;
Paillet, Alexis;
Schmisser, Roseline;
Vella, Bruno;
Damery, Jean-Charles;
Boyce, Kevin;
DiPirro, Michael;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Clerc, Nicolas;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Kirsch, Christian;
Cucchetti, Edoardo;
Eckart, Megan;
Ferrando, Philippe;
Natalucci, Lorenzo
Submitted: 2018-07-16
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray
spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5'
equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a
spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is
based on a large format array of super-conducting molybdenum-gold Transition
Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold
and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector
located underneath the prime TES array enables the non X-ray background to be
reduced. A bath temperature of about 50 mK is obtained by a series of
mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers
which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with
an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing
enables to read out 40 pixels in one single channel. A photon interacting with
an absorber leads to a current pulse, amplified by the readout electronics and
whose shape is reconstructed on board to recover its energy with high accuracy.
The defocusing capability offered by the Athena movable mirror assembly enables
the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like
intensities) by spreading the telescope point spread function over hundreds of
pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and
typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10
or more better than Silicon based X-ray detectors. In this paper, the current
X-IFU baseline is presented, together with an assessment of its anticipated
performance in terms of spectral resolution, background, and count rate
capability. The X-IFU baseline configuration will be subject to a preliminary
requirement review that is scheduled at the end of 2018.
[8]
oai:arXiv.org:1807.01594 [pdf] - 1710734
Energy scale calibration and drift correction of the X-IFU
Submitted: 2018-07-04
The Athena X-Ray Integral Field Unit (X-IFU) will provide spatially resolved
high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV
energy band. It will comprise an array of 3840 superconducting Transition Edge
Sensors (TESs) operated at 90 mK, with an absolute energy scale accuracy of 0.4
eV. Slight changes in the TES operating environment can cause significant
variations in its energy response function, which may result in degradation of
the detector's energy resolution, and eventually in systematic errors in the
absolute energy scale if not properly corrected. These changes will be
monitored via an onboard Modulated X-ray Source (MXS) and the energy scale will
be corrected accordingly using a multi-parameter interpolation of gain curves
obtained during ground calibration. Assuming realistic MXS configurations and
using the instrument end-to-end simulator SIXTE, we investigate here both
statistical and systematic effects on the X-IFU energy scale, occurring either
during ground measurements or in-flight. The corresponding impacts on the
energy resolution and means of accounting for these errors are also addressed.
We notably demonstrate that a multi-parameter gain correction, using both the
pulse-height estimate and the baseline of a pulse, can accurately recover
systematic effects on the gain due to realistic changes in TES operating
conditions within 0.4 eV. Optimisations of this technique with respect to the
MXS line configuration and correction time, as well as to the energy scale
parametrization are also show promising results to improve the accuracy of the
correction.
[9]
oai:arXiv.org:1807.01582 [pdf] - 1710730
Testing the X-IFU calibration requirements: an example for quantum
efficiency and energy resolution
Cucchetti, Edoardo;
Pajot, François;
Pointecouteau, Etienne;
Peille, Philippe;
Betancourt-Martinez, Gabriele;
Smith, Stephen J.;
Barbera, Marco;
Eckart, Megan E.;
Bandler, Simon R.;
Kilbourne, Caroline A.;
Cappi, Massimo;
Barret, Didier
Submitted: 2018-07-04
With its array of 3840 Transition Edge Sensors (TESs) operated at 90 mK, the
X-Ray Integral Field Unit (X-IFU) on board the ESA L2 mission Athena will
provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7
keV) over the 0.2 to 12 keV bandpass. The in-flight performance of the X-IFU
will be strongly affected by the calibration of the instrument. Uncertainties
in the knowledge of the overall system, from the filter transmission to the
energy scale, may introduce systematic errors in the data, which could
potentially compromise science objectives - notably those involving line
characterisation e.g. turbulence velocity measurements - if not properly
accounted for. Defining and validating calibration requirements is therefore of
paramount importance. In this paper, we put forward a simulation tool based on
the most up-to-date configurations of the various subsystems (e.g. filters,
detector absorbers) which allows us to estimate systematic errors related to
uncertainties in the instrumental response. Notably, the effect of
uncertainties in the energy resolution and of the instrumental quantum
efficiency on X-IFU observations is assessed, by taking as a test case the
measurements of the iron K complex in the hot gas surrounding clusters of
galaxies. In-flight and ground calibration of the energy resolution and the
quantum efficiency is also addressed. We demonstrate that provided an accurate
calibration of the instrument, such effects should be low in both cases with
respect to statistics during observations.
[10]
oai:arXiv.org:1807.01573 [pdf] - 1710729
Reproducibility and monitoring of the instrumental particle background
for the X-Ray Integral Field Unit
Cucchetti, Edoardo;
Pointecouteau, Etienne;
Barret, Didier;
Lotti, Simone;
Macculi, Claudio;
Molendi, Silvano;
Pajot, François;
Peille, Philippe;
Piro, Luigi;
Pratt, Gabriel W.
Submitted: 2018-07-04
The X-ray Integral Field Unit (X-IFU) is the cryogenic imaging spectrometer
on board the future X-ray observatory \textsl{Athena}. With a hexagonal array
of 3840 AC-biased Transition Edge Sensors (TES), it will provide narrow-field
observations (5$^{\prime}$ equivalent diameter) with unprecedented high
spectral resolution (2.5 eV up to 7 keV) over the 0.2 - 12 keV bandpass.
Throughout its observations, the X-IFU will face various sources of X-ray
background. Specifically, the so-called Non-X-ray Background (NXB) caused by
the interaction of high-energy cosmic rays with the instrument, may lead to a
degradation of its sensitivity in the observation of faint extended sources
(e.g. galaxy clusters outskirts). To limit this effect, a cryogenic
anti-coincidence detector (CryoAC) will be placed below the detector plane to
lower the NXB level down to the required level of $5 \times 10^{-3}$
cts/s/cm$^{2}$/keV over 2 - 10 keV. In this contribution, we investigate ways
to accurately monitor the NXB and ensure the highest reproducibility in-flight.
Using the limiting science case of the background-dominated observation of
galaxy clusters outskirts, we demonstrate that a reproducibility of 2\% on the
absolute knowledge of the background is required to perform driving science
objectives, such as measuring abundances and turbulence in the outskirts.
Monitoring of the NXB in-flight through closed observations, the detector's
CryoAC or the companion instrument (Wide Field Imager) will be used to meet
this requirement.
[11]
oai:arXiv.org:1608.08105 [pdf] - 1467926
The Athena X-ray Integral Field Unit (X-IFU)
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Barcons, Xavier;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rożanska, Agata;
Wilms, Joern;
Barbera, Marco;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Decourchelle, Anne;
Hartog, Roland den;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Renotte, Etienne;
Schaye, Joop;
Shinozaki, Keisuke;
Valenziano, Luca;
Vink, Jacco;
Webb, Natalie;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Du, Michel Le;
Mesnager, Jean-Michel;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Dadina, Mauro;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Miller, Jon;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Torrejon, Jose Miguel;
Geoffray, Hervé;
Hernandez, Isabelle;
Luno, Laure;
Peille, Philippe;
André, Jérôme;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hassin, Jérémie;
Hervet, Gilles;
Maussang, Irwin;
Moueza, Jérôme;
Paillet, Alexis;
Vella, Bruno;
Garrido, Gonzalo Campos;
Damery, Jean-Charles;
Panem, Chantal;
Panh, Johan;
Bandler, Simon;
Biffi, Jean-Marc;
Boyce, Kevin;
Clénet, Antoine;
DiPirro, Michael;
Jamotton, Pierre;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Brand, Thorsten;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Cucchetti, Edoardo
Submitted: 2016-08-29
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for
High-ENergy Astrophysics (Athena) will provide spatially resolved
high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels
over a field of view of 5 arc minute equivalent diameter and a spectral
resolution of 2.5 eV up to 7 keV. In this paper, we first review the core
scientific objectives of Athena, driving the main performance parameters of the
X-IFU, namely the spectral resolution, the field of view, the effective area,
the count rate capabilities, the instrumental background. We also illustrate
the breakthrough potential of the X-IFU for some observatory science goals.
Then we briefly describe the X-IFU design as defined at the time of the mission
consolidation review concluded in May 2016, and report on its predicted
performance. Finally, we discuss some options to improve the instrument
performance while not increasing its complexity and resource demands (e.g.
count rate capability, spectral resolution).
The X-IFU will be provided by an international consortium led by France, The
Netherlands and Italy, with further ESA member state contributions from
Belgium, Finland, Germany, Poland, Spain, Switzerland and two international
partners from the United States and Japan.