sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Creswick, R. J.

Normalized to: Creswick, R.

13 article(s) in total. 221 co-authors, from 1 to 13 common article(s). Median position in authors list is 2,0.

[1]  oai:arXiv.org:2004.01642  [pdf] - 2104020
ALP Search Using a Fabry Perot Cavity
Comments:
Submitted: 2020-04-03, last modified: 2020-05-29
In this paper we outline an experiment to detect the conversion of photons to axion-like particles (ALPs) in a strong magnetic field. We show that by modulating the polarization of the light passing through a Fabry-Perot cavity so that it effectively precesses at the modulation frequency, a signal is produced that is proportional to the square as opposed to the fourth power of the ALP-photon coupling constant. Assuming shot noise to be the dominant source of noise, we estimate that this approach is sensitive ALP masses less than $10^{-4} eV$ and couplings on the order to $g_{a\gamma}\sim 10^{-11} \text{GeV}^{-1}$ with a 10m, 10 T magnet, and $g_{a\gamma}\sim 10^{-12} \text{GeV}^{-1}$ with a 100 m magnet as envisaged by ALPs-IIc. ALPs with these properties have been invoked to explain the apparent transparency of the extragalactic background light (EBL) to ultra high-energy gamma rays emitted by BLAZARs.
[2]  oai:arXiv.org:1512.01298  [pdf] - 1359023
Sensitivity of the CUORE detector to $14.4$ keV solar axions emitted by the M1 nuclear transition of$~^{57}$Fe
Comments:
Submitted: 2015-12-03, last modified: 2016-01-22
In this paper we present a calculation of the sensitivity of the CUORE detector to the monoenergetic $14.4$ keV solar axions emitted by the M1 nuclear transition of$~^{57}$Fe in the Sun and detected by inverse coherent Bragg-Primakoff conversion in single-crystal $TeO_2$ bolometers. The expected counting rate is calculated using density functional theory for the electron charge density of $TeO_2$ and realistic background and energy resolution of CUORE. Monte Carlo simulations for $5$ y $\times$ $741$ kg=$3705-$kg$\cdot$y of exposure are analyzed using time correlation of individual events with the theoretical time-dependent counting rate. We find an expected model-independent limit on the product of the axion-photon coupling and the axion-nucleon coupling $g_{a\gamma\gamma}g_{aN}^{\text{eff}}<1.105\times 10^{-16}$ /GeV for axion masses less than 500 eV with $95\%$ confidence level.
[3]  oai:arXiv.org:1507.00603  [pdf] - 1304017
Theoretical Estimate of the Sensitivity of the CUORE Detector to Solar Axions
Comments: Corrected typos and made the form of the references uniform
Submitted: 2015-07-02, last modified: 2015-09-29
In this paper we calculate the potential sensitivity of the CUORE detector to axions produced in the Sun through the Primakoff process and detected by the inverse coherent Bragg-Primakoff process. The conversion rate is calculated using density functional theory for the electron density and realistic expectations for the energy resolution and background of CUORE. Monte Carlo calculations for $5~$y$\times741~$kg=$3705~$kg y of exposure are analyzed using time correlation of individual events with the theoretical time-dependent counting rate and lead to an expected limit on the axion-photon coupling $g_{a\gamma\gamma}<3.83\times 10^{-10}~GeV^{-1}$ for axion masses less than $100$ eV.
[4]  oai:arXiv.org:1403.0475  [pdf] - 797476
A search for bremsstrahlung solar axions using the Majorana low-background BEGe detector at Kimballton (MALBEK)
Comments: This paper has been withdrawn by the authors. Recent results we were not aware of should be taken into account
Submitted: 2014-03-03, last modified: 2014-03-17
A low-background, high-purity germanium detector has been used to search for evidence of low-energy, bremsstrahlung-generated solar axions. An upper bound of $1.36\times 10^{-11}$ $(95% CL)$ is placed on the direct coupling of DFSZ model axions to electrons. The prospects for the sensitivity of the Majorana Demonstrator array of point-contact germanium detectors to solar axions are discussed in the context of the model-independent annual modulation due to the seasonal variation of the earth-sun distance.
[5]  oai:arXiv.org:1209.2519  [pdf] - 621874
The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments
Alessandria, F.; Ardito, R.; Artusa, D. R.; Avignone, F. T.; Azzolini, O.; Balata, M.; Banks, T. I.; Bari, G.; Beeman, J.; Bellini, F.; Bersani, A.; Biassoni, M.; Bloxham, T.; Brofferio, C.; Bucci, C.; Cai, X. Z.; Canonica, L.; Capelli, S.; Carbone, L.; Cardani, L.; Carrettoni, M.; Casali, N.; Chott, N.; Clemenza, M.; Cosmelli, C.; Cremonesi, O.; Creswick, R. J.; Dafinei, I.; Dally, A.; Datskov, V.; De Biasi, A.; Decowski, M. P.; Deninno, M. M.; Di Domizio, S.; di Vacri, M. L.; Ejzak, L.; Faccini, R.; Fang, D. Q.; Farach, H. A.; Ferri, E.; Ferroni, F.; Fiorini, E.; Franceschi, M. A.; Freedman, S. J.; Frossati, G.; Fujikawa, B. K.; Giachero, A.; Gironi, L.; Giuliani, A.; Goett, J. J.; Gorla, P.; Gotti, C.; Guardincerri, E.; Gutierrez, T. D.; Haller, E. E.; Han, K.; Heeger, K. M.; Huang, H. Z.; Kadel, R.; Kazkaz, K.; Keppel, G.; Kogler, L.; Kolomensky, Yu. G.; Lenz, D.; Li, Y. L.; Ligi, C.; Liu, X.; Ma, Y. G.; Maiano, C.; Maino, M.; Martinez, M.; Maruyama, R. H.; Moggi, N.; Morganti, S.; Napolitano, T.; Newman, S.; Nisi, S.; Nones, C.; Norman, E. B.; Nucciotti, A.; Orio, F.; Orlandi, D.; Ouellet, J. L.; Pallavicini, M.; Palmieri, V.; Pattavina, L.; Pavan, M.; Pedretti, M.; Pessina, G.; Pirro, S.; Previtali, E.; Rampazzo, V.; Rimondi, F.; Rosenfeld, C.; Rusconi, C.; Sangiorgio, S.; Scielzo, N. D.; Sisti, M.; Smith, A. R.; Stivanello, F.; Taffarello, L.; Tenconi, M.; Tian, W. D.; Tomei, C.; Trentalange, S.; Ventura, G.; Vignati, M.; Wang, B. S.; Wang, H. W.; Whitten, C. A.; Wise, y T.; Woodcraft, A.; Zanotti, L.; Zarra, C.; Zhu, B. X.; Zucchelli, S.
Comments: 9 pages, 10 figures
Submitted: 2012-09-12, last modified: 2013-02-01
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak is presently unknown, but its presence is confirmed by a reanalysis of 62.7 kg.days of data from the finished CUORICINO experiment. Finally, we report the expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers) experiments to a WIMP annual modulation signal.
[6]  oai:arXiv.org:1007.0214  [pdf] - 1033451
Directional Dependence and Diurnal Modulation in Dark Matter Detectors
Comments:
Submitted: 2010-07-01, last modified: 2011-05-17
In this paper we study the effect of the channeling of ions recoiling from collisions with weakly interacting massive particles (WIMPs) in single crystal detectors. In particular we investigate the possibility that channeling may give rise to diurnal modulations of the counting rate as the Earth rotates relative to the direction of the WIMP wind, and the effect that channeling has on the "quenching factor" of a detector.
[7]  oai:arXiv.org:1002.2718  [pdf] - 1025181
The experimental challenge of detecting solar axion-like particles to test cosmological ALP-photon oscillation hypothesis
Comments: 4 pages, no figures
Submitted: 2010-02-13, last modified: 2010-10-04
We consider possible experimental tests of recent hypotheses suggesting that TeV photons survive the pair production interaction with extragalactic background light over cosmological distances by converting to axion-like particles (ALPs) in galactic magnetic fields. We show that proposed giant ultra-low background scintillation detectors will even have a difficult time reaching the present CAST sensitivity, which is one to two orders of magnitude less sensitive than necessary for a meaningful test of the ALP-photon oscillation hypothesis. Potential alternative tests are briefly discussed.
[8]  oai:arXiv.org:0903.4451  [pdf] - 1001764
Can large scintillators be used for solar-axion searches to test the cosmological axion-photon oscillation proposal?
Comments: 7 pages and no figures
Submitted: 2009-03-25, last modified: 2009-07-19
Solar-axion interaction rates in NaI, CsI and Xe scintillators via the axio-electric effect were calculated. A table is presented with photoelectric and axioelectric cross sections, solar-axion fluxes, and the interaction rates from 2.0 to 10.0 keV. The results imply that annual-modulation data of large NaI and CsI arrays, and large Xe scintillation chambers, might be made sensitive enough to probe coupling to photons at levels required to explain axion-photon oscillation phenomena proposed to explain the survival of high-energy photons traveling cosmological distances. The DAMAA/LIBRA data are used to demonstrate the power of the model-independent annual modulation due to the seasonal variation in the earth sun distance.
[9]  oai:arXiv.org:0805.2142  [pdf] - 12634
Density Gradient and Absorption Effects in Gas-Filled Magnetic Axion Helioscopes
Comments: 8 pages, 2 figures
Submitted: 2008-05-14
The effects of absorption in the gas, and of density variations on the sensitivity of gas-filled solar-axion helioscopes are theoretically investigated. It is concluded that the 10-meter long CAST helioscope, the most sensitive experiment to date is near the limit of sensitivity in axion mass. Increasing the length, gas density, or tilt angle all have negative influences, and will not improve the sensitivity.
[10]  oai:arXiv.org:astro-ph/9801176  [pdf] - 100025
A Decommissioned LHC Model Magnet as an Axion Telescope
Comments: Final version, accepted for publication in Nucl. Instr. Meth. A. More information can be found at http://wwwinfo.cern.ch/~collar/SATAN/alvaro.html
Submitted: 1998-01-18, last modified: 1999-01-22
The 8.4 Tesla, 10 m long transverse magnetic field of a twin aperture LHC bending magnet can be utilized as a macroscopic coherent solar axion-to-photon converter. Numerical calculations show that the integrated time of alignment with the Sun would be 33 days per year with the magnet on a tracking table capable of $\pm 5^o$ in the vertical direction and $\pm 40^o$ in the horizontal direction. The existing lower bound on the axion-to-photon coupling constant can be improved by a factor between 50 and 100 in 3 years, i.e., $g_{a\gamma\gamma} \lesssim 9\cdot 10^{-11} GeV^{-1}$ for axion masses $\lesssim$ 1 eV. This value falls within the existing open axion mass window. The same set-up can simultaneously search for low- and high-energy celestial axions, or axion-like particles, scanning the sky as the Earth rotates and orbits the Sun.
[11]  oai:arXiv.org:astro-ph/9712308  [pdf] - 1235170
Experimental Search for Solar Axions
Comments: List of authors now complete. 5 pages (A4), LaTex, 4 PS figures, uses epsf and espcrc2(included) macros. Talk at the 5th International Workshop on ``Topics in Astroparticle and Underground Physics'' (TAUP97), Gran Sasso, Italy, 7-11 September, 1997, to appear in the Proceedings, Nucl. Phys. B(PS), A. Bottino, A. di Credico and P. Monacelli (eds.)
Submitted: 1997-12-23, last modified: 1997-12-26
A new technique has been used to search for solar axions using a single crystal germanium detector. It exploits the coherent conversion of axions into photons when their angle of incidence satisfies a Bragg condition with a crystalline plane. The analysis of approximately 1.94 kg.yr of data from the 1-kg DEMOS detector in Sierra Grande, Argentina, yields a new laboratory bound on axion-photon coupling of g_{a,\gamma\gamma}<2.7\times 10^{-9} GeV^{-1} independent of axion mass up to \sim 1 keV.
[12]  oai:arXiv.org:hep-ph/9708210  [pdf] - 116055
Theory for the Direct Detection of Solar Axions by Coherent Primakoff Conversion in Germanium Detectors
Comments: gzipped postscript file from Microsoft Word, 8 pages. Figures can be obtained by fax from Juan.Collar@cern.ch. Submitted to Phys. Lett. B
Submitted: 1997-08-01
It is assumed that axions exist and are created in the Sun by Primakoff conversion of photons in the Coulomb fields of nuclei. Detection rates are calculated in germanium detectors due to the coherent conversion of axions to photons in the lattice when the incident angle fulfills the Bragg condition for a given crystalline plane. The rates are correlated with the relative positions of the Sun and detector, yielding a characteristic recognizable sub-diurnal temporal pattern. A major experiment is proposed based on a large detector array.
[13]  oai:arXiv.org:astro-ph/9708008  [pdf] - 98186
Experimental Search for Solar Axions via Coherent Primakoff Conversion in a Germanium Spectrometer
Comments: RevTeX, 11 pages, figures can be obtained by fax from Juan.Collar@cern.ch. Submitted to Phys. Lett. B
Submitted: 1997-08-01
Results are reported of an experimental search for the unique, rapidly varying temporal pattern of solar axions coherently converting into photons via the Primakoff effect in a single crystal germanium detector. This conversion is predicted when axions are incident at a Bragg angle with a crystalline plane. The analysis of approximately 1.94 kg.yr of data from the 1 kg DEMOS detector in Sierra Grande, Argentina, yields a new laboratory bound on axion-photon coupling of $g_{a\gamma \gamma} < 2.7\cdot 10^{-9}$ GeV$^{-1}$, independent of axion mass up to ~ 1 keV.