Normalized to: Coutts, D.
[1]
oai:arXiv.org:2003.08205 [pdf] - 2066592
Rubidium transitions as wavelength reference for astronomical Doppler
spectrographs
Rogozin, Dmytro;
Feger, Tobias;
Schwab, Christian;
Gurevich, Yulia V.;
Raskin, Gert;
Coutts, David W.;
Stuermer, Julian;
Seifahrt, Andreas;
Fuehrer, Thorsten;
Legero, Thomas;
van Winckel, Hans;
Halverson, Sam;
Quirrenbach, Andreas
Submitted: 2020-03-17
Precise wavelength calibration is a critical issue for high-resolution
spectroscopic observations. The ideal calibration source should be able to
provide a very stable and dense grid of evenly distributed spectral lines of
constant intensity. A new method which satisfies all mentioned conditions has
been developed by our group. The approach is to actively measure the exact
position of a single spectral line of a Fabry-Perot etalon with very high
precision with a wavelength-tuneable laser and compare it to an extremely
stable wavelength standard. The ideal choice of standard is the D2 absorption
line of Rubidium, which has been used as an optical frequency standard for
decades. With this technique, the problem of stable wavelength calibration of
spectrographs becomes a problem of how reliably we can measure and anchor one
etalon line to the Rb transition. In this work we present our self-built module
for Rb saturated absorption spectroscopy and discuss its stability.
[2]
oai:arXiv.org:1911.08325 [pdf] - 2000368
Fiber modal noise mitigation by a rotating double scrambler
Submitted: 2019-11-16
Fiber modal noise is a performance limiting factor in high-precision radial
velocity measurements with multi-mode fiber-fed high-resolution spectrographs.
Traditionally, modal noise is mitigated by agitating the fiber, this way
redistributing the light that propagates in the fiber over many different
modes. However, in case of fibers with only a limited number of modes, e.g. at
near-infrared wavelengths or in adaptive-optics assisted systems, this method
becomes very inefficient. The strong agitation that would be needed stresses
the fiber and can lead to focal ratio degradation. As an alternative approach,
we propose to use a classic optical double scrambler and to rotate the
scrambler's first fiber end during each exposure. Because of the rotating
illumination pattern of the scrambler's second fiber, the modes that are
excited vary continuously. This leads to very efficient averaging of the modal
pattern at the fiber exit and to a strong reduction of modal noise. In this
contribution, we present a prototype design and first laboratory results of the
rotating double scrambler.
[3]
oai:arXiv.org:1901.07567 [pdf] - 1821202
The need for single-mode fiber-fed spectrographs
Crass, Jonathan;
Bechter, Andrew;
Bechter, Eric;
Beichman, Charles;
Blake, Cullen;
Coutts, David;
Feger, Tobias;
Halverson, Sam;
Harris, Robert J.;
Jovanovic, Nemanja;
Plavchan, Peter;
Schwab, Christian;
Vasisht, Gautam;
Wallace, James K.;
Wang, Ji
Submitted: 2019-01-22, last modified: 2019-01-24
Precise Doppler radial-velocity (RV) instruments will continue to play an
essential role in advancing our holistic understanding of exoplanetary systems.
The combination of orbital parameters from transit surveys and follow-up RV
measurements is vital to unlock mass and density estimates of detected planets,
giving us insight into their environment and structure. However, the exoplanet
field is reaching a critical juncture: the measurement sensitivity of existing
radial-velocity instruments is becoming the limiting factor in further
increasing our knowledge. Without improvement in delivered RV measurement
precision, we will not be able to provide dynamical mass and density estimates
for some of the most exciting (and consequently most challenging) discoveries
expected from new transit missions including the Transiting Exoplanet Survey
Satellite (TESS) (Plavchan et al. 2015, Ricker et al. 2014). RV precisions at
the 10cm/s level are required to fully confirm earth-like analogues, provide
masses and measure density to the 1-5% level from these missions. Additionally,
this RV capability will also be important to allow for efficient target
selection for facilities such as the James Webb Space Telescope (JWST). A
promising way forward to achieve this goal is to use single-mode fibers to
inject light to a spectrograph. This mitigates many of the error terms facing
current generation seeing-limited RV instruments while simultaneously offering
the capability of high resolution spectroscopy within a small optical footprint
(Schwab et al. 2012, Crepp 2014, Jovanovic et al. 2016a). We discuss the
benefits of this technique, its challenges, and the current status of
development.
[4]
oai:arXiv.org:1712.08584 [pdf] - 1607148
Pioneering high contrast science instruments for planet characterization
on giant segmented mirror telescopes
Jovanovic, N.;
Guyon, O.;
Lozi, J.;
Tamura, M.;
Norris, B.;
Tuthill, P.;
Huby, E.;
Perrin, G.;
Lacour, S.;
Marchis, F.;
Duchene, G.;
Gauchet, L.;
Ireland, M.;
Feger, T.;
Rains, A.;
Bento, J.;
Schwab, C.;
Coutts, D.;
Cvetojevic, N.;
Gross, S.;
Arriola, A.;
Lagadec, T.;
Goebel, S.;
Hall, D.;
Jacobson, S.;
Mazin, B.;
Walter, A.;
Massie, J.;
Groff, T.;
Chilcote, J.;
Kasdin, J.;
Brandt, T.;
Loomis, C.;
Galvin, M.;
Kotani, T.;
Kawahara, H.;
Martinache, F.;
Pathak, P.;
Males, J.
Submitted: 2017-12-22
A suite of science instruments is critical to any high contrast imaging
facility, as it defines the science capabilities and observing modes available.
SCExAO uses a modular approach which allows for state-of-the-art visitor
modules to be tested within an observatory environment on an 8-m class
telescope. This allows for rapid prototyping of new and innovative imaging
techniques that otherwise take much longer in traditional instrument design.
With the aim of maturing science modules for an advanced high contrast imager
on an giant segmented mirror telescopes (GSMTs) that will be capable of imaging
terrestrial planets, we offer an overview and status update on the various
science modules currently under test within the SCExAO instrument.