Normalized to: Cothard, N.
[1]
oai:arXiv.org:1908.10451 [pdf] - 2072556
Sensitivity of the Prime-Cam Instrument on the CCAT-prime Telescope
Choi, Steve K.;
Austermann, Jason;
Basu, Kaustuv;
Battaglia, Nicholas;
Bertoldi, Frank;
Chung, Dongwoo T.;
Cothard, Nicholas F.;
Duff, Shannon;
Duell, Cody J.;
Gallardo, Patricio A.;
Gao, Jiansong;
Herter, Terry;
Hubmayr, Johannes;
Niemack, Michael D.;
Nikola, Thomas;
Riechers, Dominik;
Rossi, Kayla;
Stacey, Gordon J.;
Stevens, Jason R.;
Vavagiakis, Eve M.;
Vissers, Michael;
Walker, Samantha
Submitted: 2019-08-27, last modified: 2020-03-31
CCAT-prime is a new 6 m crossed Dragone telescope designed to characterize
the Cosmic Microwave Background (CMB) polarization and foregrounds, measure the
Sunyaev-Zel'dovich effects of galaxy clusters, map the [CII] emission intensity
from the Epoch of Reionization (EoR), and monitor accretion luminosity over
multi-year timescales of hundreds of protostars in the Milky Way. CCAT-prime
will make observations from a 5,600 m altitude site on Cerro Chajnantor in the
Atacama Desert of northern Chile. The novel optical design of the telescope
combined with high surface accuracy ($<$10 $\mu$m) mirrors and the exceptional
atmospheric conditions of the site will enable sensitive broadband,
polarimetric, and spectroscopic surveys at sub-mm to mm wavelengths. Prime-Cam,
the first light instrument for CCAT-prime, consists of a 1.8 m diameter
cryostat that can house seven individual instrument modules. Each instrument
module, optimized for a specific science goal, will use state-of-the-art
kinetic inductance detector (KID) arrays operated at $\sim$100 mK, and
Fabry-Perot interferometers (FPI) for the EoR science. Prime-Cam will be
commissioned with staged deployments to populate the seven instrument modules.
The full instrument will consist of 60,000 polarimetric KIDs at a combination
of 220/280/350/410 GHz, 31,000 KIDS at 250/360 GHz coupled with FPIs, and
21,000 polarimetric KIDs at 850 GHz. Prime-Cam is currently being built, and
the CCAT-prime telescope is designed and under construction by Vertex
Antennentechnik GmbH to achieve first light in 2021. CCAT-prime is also a
potential telescope platform for the future CMB Stage-IV observations.
[2]
oai:arXiv.org:1912.00860 [pdf] - 2065329
Characterization of Transition Edge Sensors for the Simons Observatory
Stevens, Jason R.;
Cothard, Nicholas F.;
Vavagiakis, Eve M.;
Ali, Aamir;
Arnold, Kam;
Austermann, Jason E.;
Choi, Steve K.;
Dober, Bradley J.;
Duell, Cody;
Duff, Shannon M.;
Hilton, Gene C.;
Ho, Shuay-Pwu Patty;
Hoang, Thuong D.;
Hubmayr, Johannes;
Lee, Adrian T.;
Mangu, Aashrita;
Nati, Federico;
Niemack, Michael D.;
Raum, Christopher;
Renzullo, Mario;
Salatino, Maria;
Sasse, Trevor;
Simon, Sara M.;
Staggs, Suzanne;
Suzuki, Aritoki;
Truitt, Patrick;
Ullom, Joel;
Vivalda, John;
Vissers, Michael R.;
Walker, Samantha;
Westbrook, Benjamin;
Wollack, Edward J.;
Xu, Zhilei;
Yohannes, Daniel
Submitted: 2019-12-02, last modified: 2020-01-21
The Simons Observatory is building both large (6 m) and small (0.5 m)
aperture telescopes in the Atacama desert in Chile to observe the cosmic
microwave background (CMB) radiation with unprecedented sensitivity. Simons
Observatory telescopes in total will use over 60,000 transition edge sensor
(TES) detectors spanning center frequencies between 27 and 285 GHz and
operating near 100 mK. TES devices have been fabricated for the Simons
Observatory by NIST, Berkeley, and HYPRES/SeeQC corporation. Iterations of
these devices have been tested cryogenically in order to inform the fabrication
of further devices, which will culminate in the final TES designs to be
deployed in the field. The detailed design specifications have been
independently iterated at each fabrication facility for particular detector
frequencies.
We present test results for prototype devices, with emphasis on NIST high
frequency detectors. A dilution refrigerator was used to achieve the required
temperatures. Measurements were made both with 4-lead resistance measurements
and with a time domain Superconducting Quantum Interference Device (SQUID)
multiplexer system. The SQUID readout measurements include analysis of current
vs voltage (IV) curves at various temperatures, square wave bias step
measurements, and detector noise measurements. Normal resistance,
superconducting critical temperature, saturation power, thermal and natural
time constants, and thermal properties of the devices are extracted from these
measurements.
[3]
oai:arXiv.org:1912.12782 [pdf] - 2050328
Commercially fabricated antenna-coupled Transition Edge Sensor bolometer
detectors for next generation Cosmic Microwave Background polarimetry
experiment
Suzuki, Aritoki;
Cothard, Nicholas;
Lee, Adrian T.;
Niemack, Michael D.;
Raum, Christopher;
Renzullo, Mario;
Sasse, Trevor;
Stevens, Jason;
Truitt, Patrick;
Vavagiakis, Eve;
Vivalda, John;
Westrook, Benjamin;
Yohannes, Daniel
Submitted: 2019-12-29
We report on the development of commercially fabricated multi-chroic antenna
coupled Transition Edge Sensor (TES) bolometer arrays for Cosmic Microwave
Background (CMB) polarimetry experiments. The orders of magnitude increase in
detector count for next-generation CMB experiments requires a new approach in
detector wafer production to increase fabrication throughput.
We describe collaborative efforts with a commercial superconductor
electronics fabrication facility (SeeQC, Inc.) to fabricate antenna coupled TES
bolometer detectors. We have successfully fabricated an operational
dual-polarization, dichroic sinuous antenna-coupled TES detector array on a 150
mm diameter wafer. The fabricated detector arrays have average yield of 95\%
and excellent uniformity across the wafer. Both RF characteristics and TES
bolometer properties are suitable for CMB observations. We successfully
fabricated different types of TES bolometers optimized for
frequency-multiplexing readout, time-domain multiplexing readout, and microwave
SQUID multiplexing readout. We also demonstrated high production throughput. We
discuss the motivation, design considerations, fabrication processes, test
results, and how industrial detector fabrication could be a path to fabricate
hundreds of detector wafers for future CMB polarimetry experiments.
[4]
oai:arXiv.org:1912.02902 [pdf] - 2065335
Characterization of aliased noise in the Advanced ACTPol receiver
Gallardo, Patricio A.;
Niemack, Michael D.;
Austermann, Jason E.;
Beall, James A.;
Cothard, Nick F.;
Duell, Cody J.;
Duff, Shannon M.;
Henderson, Shawn W.;
Hilton, Gene C.;
Ho, Shuay-Pwu Patty;
Hubmayr, Johannes;
Reintsema, Carl D.;
Salatino, Maria;
Ullom, Joel;
Van Lanen, Jeff;
Vissers, Michael;
Wollack, Edward J.
Submitted: 2019-12-05
Advanced ACTPol is the second generation polarization-sensitive upgrade to
the $6\, \rm m$ aperture Atacama Cosmology Telescope (ACT), which increased
detector count and frequency coverage compared to the previous ACTPol receiver.
Advanced ACTPol utilizes a new two-stage time-division multiplexing readout
architecture based on superconducting quantum interference devices (SQUIDs) to
achieve a multiplexing factor as high as 64 (rows), fielding a 2,012 detector
camera at 150/220 GHz and two 90/150 GHz cameras containing 1,716 detectors
each. In a time domain system, aliasing introduces noise to the readout. In
this work we present a figure of merit to measure this noise contribution and
present measurements of the aliased noise fraction of the Advanced ACTPol
receiver as deployed.
[5]
oai:arXiv.org:1911.11687 [pdf] - 2038357
The Design of The CCAT-prime Epoch of Reionization Spectrometer
Instrument
Cothard, Nicholas F;
Choi, Steve K;
Duell, Cody J;
Herter, Terry;
Hubmayr, Johannes;
McMahon, Jeff;
Niemack, Michael D;
Nikola, Thomas;
Sierra, Carlos;
Stacey, Gordon J;
Vavagiakis, Eve M;
Wollack, Edward J;
Zou, Bugao
Submitted: 2019-11-26
The Epoch of Reionization Spectrometer (EoR-Spec) is an instrument module for
the Prime-Cam receiver of the 6 m aperture CCAT-prime Telescope at 5600 m in
Chile. EoR-Spec will perform 158 $\mu$m [CII] line intensity mapping of
star-forming regions at redshifts between 3.5 and 8 (420 - 210 GHz), tracing
the evolution of structure during early galaxy formation. At lower redshifts,
EoR-Spec will observe galaxies near the period of peak star formation - when
most stars in today's universe were formed. At higher redshifts, EoR-Spec will
trace the late stages of reionization, the early stages of galaxy assembly, and
the formation of large-scale, three-dimensional clustering of star-forming
galaxies. To achieve its science goals, EoR-Spec will utilize CCAT-prime's
exceptionally low water vapor site, large field of view ($\sim 5$ degrees at
210 GHz), and narrow beam widths ($\sim 1$ arcminute at 210 GHz). EoR-Spec will
be outfitted with a cryogenic, metamaterial, silicon substrate-based
Fabry-Perot Interferometer operating at a resolving power
($\lambda/\Delta\lambda$) of 100. Monolithic dichroic arrays of cryogenic,
feedhorn-coupled transition edge sensor bolometers provide approximately 6000
detectors, which are read out using a frequency division multiplexing system
based on microwave SQUIDs. The novel design allows the measurement of the [CII]
line at two redshifts simultaneously using dichroic pixels and two orders of
the Fabry-Perot. Here we present the design and science goals of EoR-Spec, with
emphasis on the spectrometer, detector array, and readout designs.
[6]
oai:arXiv.org:1910.10199 [pdf] - 2026098
Developing AlMn films for Argonne TES fabrication
Submitted: 2019-10-22
The reference design for the next-generation cosmic microwave background
(CMB) experiment, CMB-S4, relies on large arrays of transition edge sensor
(TES) bolometers coupled to Superconducting Quantum Interference Device
(SQUID)-based readout systems. Mapping the CMB to near cosmic variance limits
will enable the search for signatures of inflation and constrain dark energy
and neutrino physics. AlMn TESes provide simple film manufacturing and highly
uniform arrays over large areas to meet the requirements of the CMB-S4
experiment. TES parameters such as critical temperature and normal resistance
must be tuned to experiment specifications and can be varied based on geometry
and steps in the fabrication process such as deposition layering, geometry, and
baking time and temperature. Using four-terminal sensing, we measured $T_C$ and
$R_N$ of AlMn 2000 ppm films and devices of varying thicknesses fabricated at
Argonne National Laboratory to motivate device geometries and fabrication
processes to tune $T_C$ to 150-200 mK and $R_N$ to $\sim$10 mOhms. Measurements
of IV curves and time constants for the resulting devices of varying leg length
were made using time-division SQUID multiplexing, and determined $T_C$, $G$,
$k$, $f_{3db}$, and $R_N$. We present the results of these tests along with the
geometries and fabrication steps used to tune the device parameters to the
desired limits.
[7]
oai:arXiv.org:1909.02587 [pdf] - 1956586
The CCAT-Prime Submillimeter Observatory
Aravena, Manuel;
Austermann, Jason;
Basu, Kaustuv;
Battaglia, Nicholas;
Beringue, Benjamin;
Bertoldi, Frank;
Bond, J. Richard;
Breysse, Patrick;
Bustos, Ricardo;
Chapman, Scott;
Choi, Steve;
Chung, Dongwoo;
Cothard, Nicholas;
Dober, Bradley;
Duell, Cody;
Duff, Shannon;
Dunner, Rolando;
Erler, Jens;
Fich, Michel;
Fissel, Laura;
Foreman, Simon;
Gallardo, Patricio;
Gao, Jiansong;
Giovanelli, Riccardo;
Graf, Urs;
Haynes, Martha;
Herter, Terry;
Hilton, Gene;
Hlozek, Renee;
Hubmayr, Johannes;
Johnstone, Doug;
Keating, Laura;
Komatsu, Eiichiro;
Magnelli, Benjamin;
Mauskopf, Phil;
McMahon, Jeffrey;
Meerburg, P. Daniel;
Meyers, Joel;
Murray, Norm;
Niemack, Michael;
Nikola, Thomas;
Nolta, Michael;
Parshley, Stephen;
Puddu, Roberto;
Riechers, Dominik;
Rosolowsky, Erik;
Simon, Sara;
Stacey, Gordon;
Stevens, Jason;
Stutzki, Juergen;
Van Engelen, Alexander;
Vavagiakis, Eve;
Viero, Marco;
Vissers, Michael;
Walker, Samantha;
Zou, Bugao
Submitted: 2019-09-05
The Cerro Chajnantor Atacama Telescope-prime (CCAT-prime) is a new 6-m,
off-axis, low-emissivity, large field-of-view submillimeter telescope scheduled
for first light in the last quarter of 2021. In summary, (a) CCAT-prime
uniquely combines a large field-of-view (up to 8-deg), low emissivity telescope
(< 2%) and excellent atmospheric transmission (5600-m site) to achieve
unprecedented survey capability in the submillimeter. (b) Over five years,
CCAT-prime first generation science will address the physics of star formation,
galaxy evolution, and galaxy cluster formation; probe the re-ionization of the
Universe; improve constraints on new particle species; and provide for improved
removal of dust foregrounds to aid the search for primordial gravitational
waves. (c) The Observatory is being built with non-federal funds (~ \$40M in
private and international investments). Public funding is needed for
instrumentation (~ \$8M) and operations (\$1-2M/yr). In return, the community
will be able to participate in survey planning and gain access to curated data
sets. (d) For second generation science, CCAT-prime will be uniquely positioned
to contribute high-frequency capabilities to the next generation of CMB surveys
in partnership with the CMB-S4 and/or the Simons Observatory projects or
revolutionize wide-field, sub-millimetter line intensity mapping surveys.
[8]
oai:arXiv.org:1907.08284 [pdf] - 1976842
The Simons Observatory: Astro2020 Decadal Project Whitepaper
The Simons Observatory Collaboration;
Abitbol, Maximilian H.;
Adachi, Shunsuke;
Ade, Peter;
Aguirre, James;
Ahmed, Zeeshan;
Aiola, Simone;
Ali, Aamir;
Alonso, David;
Alvarez, Marcelo A.;
Arnold, Kam;
Ashton, Peter;
Atkins, Zachary;
Austermann, Jason;
Awan, Humna;
Baccigalupi, Carlo;
Baildon, Taylor;
Lizancos, Anton Baleato;
Barron, Darcy;
Battaglia, Nick;
Battye, Richard;
Baxter, Eric;
Bazarko, Andrew;
Beall, James A.;
Bean, Rachel;
Beck, Dominic;
Beckman, Shawn;
Beringue, Benjamin;
Bhandarkar, Tanay;
Bhimani, Sanah;
Bianchini, Federico;
Boada, Steven;
Boettger, David;
Bolliet, Boris;
Bond, J. Richard;
Borrill, Julian;
Brown, Michael L.;
Bruno, Sarah Marie;
Bryan, Sean;
Calabrese, Erminia;
Calafut, Victoria;
Calisse, Paolo;
Carron, Julien;
Carl, Fred. M;
Cayuso, Juan;
Challinor, Anthony;
Chesmore, Grace;
Chinone, Yuji;
Chluba, Jens;
Cho, Hsiao-Mei Sherry;
Choi, Steve;
Clark, Susan;
Clarke, Philip;
Contaldi, Carlo;
Coppi, Gabriele;
Cothard, Nicholas F.;
Coughlin, Kevin;
Coulton, Will;
Crichton, Devin;
Crowley, Kevin D.;
Crowley, Kevin T.;
Cukierman, Ari;
D'Ewart, John M.;
Dünner, Rolando;
de Haan, Tijmen;
Devlin, Mark;
Dicker, Simon;
Dober, Bradley;
Duell, Cody J.;
Duff, Shannon;
Duivenvoorden, Adri;
Dunkley, Jo;
Bouhargani, Hamza El;
Errard, Josquin;
Fabbian, Giulio;
Feeney, Stephen;
Fergusson, James;
Ferraro, Simone;
Fluxà, Pedro;
Freese, Katherine;
Frisch, Josef C.;
Frolov, Andrei;
Fuller, George;
Galitzki, Nicholas;
Gallardo, Patricio A.;
Ghersi, Jose Tomas Galvez;
Gao, Jiansong;
Gawiser, Eric;
Gerbino, Martina;
Gluscevic, Vera;
Goeckner-Wald, Neil;
Golec, Joseph;
Gordon, Sam;
Gralla, Megan;
Green, Daniel;
Grigorian, Arpi;
Groh, John;
Groppi, Chris;
Guan, Yilun;
Gudmundsson, Jon E.;
Halpern, Mark;
Han, Dongwon;
Hargrave, Peter;
Harrington, Kathleen;
Hasegawa, Masaya;
Hasselfield, Matthew;
Hattori, Makoto;
Haynes, Victor;
Hazumi, Masashi;
Healy, Erin;
Henderson, Shawn W.;
Hensley, Brandon;
Hervias-Caimapo, Carlos;
Hill, Charles A.;
Hill, J. Colin;
Hilton, Gene;
Hilton, Matt;
Hincks, Adam D.;
Hinshaw, Gary;
Hložek, Renée;
Ho, Shirley;
Ho, Shuay-Pwu Patty;
Hoang, Thuong D.;
Hoh, Jonathan;
Hotinli, Selim C.;
Huang, Zhiqi;
Hubmayr, Johannes;
Huffenberger, Kevin;
Hughes, John P.;
Ijjas, Anna;
Ikape, Margaret;
Irwin, Kent;
Jaffe, Andrew H.;
Jain, Bhuvnesh;
Jeong, Oliver;
Johnson, Matthew;
Kaneko, Daisuke;
Karpel, Ethan D.;
Katayama, Nobuhiko;
Keating, Brian;
Keskitalo, Reijo;
Kisner, Theodore;
Kiuchi, Kenji;
Klein, Jeff;
Knowles, Kenda;
Kofman, Anna;
Koopman, Brian;
Kosowsky, Arthur;
Krachmalnicoff, Nicoletta;
Kusaka, Akito;
LaPlante, Phil;
Lashner, Jacob;
Lee, Adrian;
Lee, Eunseong;
Lewis, Antony;
Li, Yaqiong;
Li, Zack;
Limon, Michele;
Linder, Eric;
Liu, Jia;
Lopez-Caraballo, Carlos;
Louis, Thibaut;
Lungu, Marius;
Madhavacheril, Mathew;
Mak, Daisy;
Maldonado, Felipe;
Mani, Hamdi;
Mates, Ben;
Matsuda, Frederick;
Maurin, Loïc;
Mauskopf, Phil;
May, Andrew;
McCallum, Nialh;
McCarrick, Heather;
McKenney, Chris;
McMahon, Jeff;
Meerburg, P. Daniel;
Mertens, James;
Meyers, Joel;
Miller, Amber;
Mirmelstein, Mark;
Moodley, Kavilan;
Moore, Jenna;
Munchmeyer, Moritz;
Munson, Charles;
Murata, Masaaki;
Naess, Sigurd;
Namikawa, Toshiya;
Nati, Federico;
Navaroli, Martin;
Newburgh, Laura;
Nguyen, Ho Nam;
Nicola, Andrina;
Niemack, Mike;
Nishino, Haruki;
Nishinomiya, Yume;
Orlowski-Scherer, John;
Pagano, Luca;
Partridge, Bruce;
Perrotta, Francesca;
Phakathi, Phumlani;
Piccirillo, Lucio;
Pierpaoli, Elena;
Pisano, Giampaolo;
Poletti, Davide;
Puddu, Roberto;
Puglisi, Giuseppe;
Raum, Chris;
Reichardt, Christian L.;
Remazeilles, Mathieu;
Rephaeli, Yoel;
Riechers, Dominik;
Rojas, Felipe;
Rotti, Aditya;
Roy, Anirban;
Sadeh, Sharon;
Sakurai, Yuki;
Salatino, Maria;
Rao, Mayuri Sathyanarayana;
Saunders, Lauren;
Schaan, Emmanuel;
Schmittfull, Marcel;
Sehgal, Neelima;
Seibert, Joseph;
Seljak, Uros;
Shellard, Paul;
Sherwin, Blake;
Shimon, Meir;
Sierra, Carlos;
Sievers, Jonathan;
Sifon, Cristobal;
Sikhosana, Precious;
Silva-Feaver, Maximiliano;
Simon, Sara M.;
Sinclair, Adrian;
Smith, Kendrick;
Sohn, Wuhyun;
Sonka, Rita;
Spergel, David;
Spisak, Jacob;
Staggs, Suzanne T.;
Stein, George;
Stevens, Jason R.;
Stompor, Radek;
Suzuki, Aritoki;
Tajima, Osamu;
Takakura, Satoru;
Teply, Grant;
Thomas, Daniel B.;
Thorne, Ben;
Thornton, Robert;
Trac, Hy;
Treu, Jesse;
Tsai, Calvin;
Tucker, Carole;
Ullom, Joel;
Vagnozzi, Sunny;
van Engelen, Alexander;
Van Lanen, Jeff;
Van Winkle, Daniel D.;
Vavagiakis, Eve M.;
Vergès, Clara;
Vissers, Michael;
Wagoner, Kasey;
Walker, Samantha;
Wang, Yuhan;
Ward, Jon;
Westbrook, Ben;
Whitehorn, Nathan;
Williams, Jason;
Williams, Joel;
Wollack, Edward;
Xu, Zhilei;
Yasini, Siavash;
Young, Edward;
Yu, Byeonghee;
Yu, Cyndia;
Zago, Fernando;
Zannoni, Mario;
Zhang, Hezi;
Zheng, Kaiwen;
Zhu, Ningfeng;
Zonca, Andrea
Submitted: 2019-07-16
The Simons Observatory (SO) is a ground-based cosmic microwave background
(CMB) experiment sited on Cerro Toco in the Atacama Desert in Chile that
promises to provide breakthrough discoveries in fundamental physics, cosmology,
and astrophysics. Supported by the Simons Foundation, the Heising-Simons
Foundation, and with contributions from collaborating institutions, SO will see
first light in 2021 and start a five year survey in 2022. SO has 287
collaborators from 12 countries and 53 institutions, including 85 students and
90 postdocs.
The SO experiment in its currently funded form ('SO-Nominal') consists of
three 0.4 m Small Aperture Telescopes (SATs) and one 6 m Large Aperture
Telescope (LAT). Optimized for minimizing systematic errors in polarization
measurements at large angular scales, the SATs will perform a deep,
degree-scale survey of 10% of the sky to search for the signature of primordial
gravitational waves. The LAT will survey 40% of the sky with arc-minute
resolution. These observations will measure (or limit) the sum of neutrino
masses, search for light relics, measure the early behavior of Dark Energy, and
refine our understanding of the intergalactic medium, clusters and the role of
feedback in galaxy formation.
With up to ten times the sensitivity and five times the angular resolution of
the Planck satellite, and roughly an order of magnitude increase in mapping
speed over currently operating ("Stage 3") experiments, SO will measure the CMB
temperature and polarization fluctuations to exquisite precision in six
frequency bands from 27 to 280 GHz. SO will rapidly advance CMB science while
informing the design of future observatories such as CMB-S4.
[9]
oai:arXiv.org:1903.04689 [pdf] - 1847062
Sidelobe analysis for the Atacama Cosmology Telescope: a novel method
for importing models in GRASP
Submitted: 2019-03-11
Telescopes for observing the Cosmic Microwave Background (CMB) usually have
shields and baffle structures in order to reduce the pickup from the ground.
These structures may introduce unwanted sidelobes. We present a method to
measure and model baffling structures of large aperture telescope optics to
predict the sidelobe pattern.
[10]
oai:arXiv.org:1808.07445 [pdf] - 1841339
The Simons Observatory: Science goals and forecasts
The Simons Observatory Collaboration;
Ade, Peter;
Aguirre, James;
Ahmed, Zeeshan;
Aiola, Simone;
Ali, Aamir;
Alonso, David;
Alvarez, Marcelo A.;
Arnold, Kam;
Ashton, Peter;
Austermann, Jason;
Awan, Humna;
Baccigalupi, Carlo;
Baildon, Taylor;
Barron, Darcy;
Battaglia, Nick;
Battye, Richard;
Baxter, Eric;
Bazarko, Andrew;
Beall, James A.;
Bean, Rachel;
Beck, Dominic;
Beckman, Shawn;
Beringue, Benjamin;
Bianchini, Federico;
Boada, Steven;
Boettger, David;
Bond, J. Richard;
Borrill, Julian;
Brown, Michael L.;
Bruno, Sarah Marie;
Bryan, Sean;
Calabrese, Erminia;
Calafut, Victoria;
Calisse, Paolo;
Carron, Julien;
Challinor, Anthony;
Chesmore, Grace;
Chinone, Yuji;
Chluba, Jens;
Cho, Hsiao-Mei Sherry;
Choi, Steve;
Coppi, Gabriele;
Cothard, Nicholas F.;
Coughlin, Kevin;
Crichton, Devin;
Crowley, Kevin D.;
Crowley, Kevin T.;
Cukierman, Ari;
D'Ewart, John M.;
Dünner, Rolando;
de Haan, Tijmen;
Devlin, Mark;
Dicker, Simon;
Didier, Joy;
Dobbs, Matt;
Dober, Bradley;
Duell, Cody J.;
Duff, Shannon;
Duivenvoorden, Adri;
Dunkley, Jo;
Dusatko, John;
Errard, Josquin;
Fabbian, Giulio;
Feeney, Stephen;
Ferraro, Simone;
Fluxà, Pedro;
Freese, Katherine;
Frisch, Josef C.;
Frolov, Andrei;
Fuller, George;
Fuzia, Brittany;
Galitzki, Nicholas;
Gallardo, Patricio A.;
Ghersi, Jose Tomas Galvez;
Gao, Jiansong;
Gawiser, Eric;
Gerbino, Martina;
Gluscevic, Vera;
Goeckner-Wald, Neil;
Golec, Joseph;
Gordon, Sam;
Gralla, Megan;
Green, Daniel;
Grigorian, Arpi;
Groh, John;
Groppi, Chris;
Guan, Yilun;
Gudmundsson, Jon E.;
Han, Dongwon;
Hargrave, Peter;
Hasegawa, Masaya;
Hasselfield, Matthew;
Hattori, Makoto;
Haynes, Victor;
Hazumi, Masashi;
He, Yizhou;
Healy, Erin;
Henderson, Shawn W.;
Hervias-Caimapo, Carlos;
Hill, Charles A.;
Hill, J. Colin;
Hilton, Gene;
Hilton, Matt;
Hincks, Adam D.;
Hinshaw, Gary;
Hložek, Renée;
Ho, Shirley;
Ho, Shuay-Pwu Patty;
Howe, Logan;
Huang, Zhiqi;
Hubmayr, Johannes;
Huffenberger, Kevin;
Hughes, John P.;
Ijjas, Anna;
Ikape, Margaret;
Irwin, Kent;
Jaffe, Andrew H.;
Jain, Bhuvnesh;
Jeong, Oliver;
Kaneko, Daisuke;
Karpel, Ethan D.;
Katayama, Nobuhiko;
Keating, Brian;
Kernasovskiy, Sarah S.;
Keskitalo, Reijo;
Kisner, Theodore;
Kiuchi, Kenji;
Klein, Jeff;
Knowles, Kenda;
Koopman, Brian;
Kosowsky, Arthur;
Krachmalnicoff, Nicoletta;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Kusaka, Akito;
Lashner, Jacob;
Lee, Adrian;
Lee, Eunseong;
Leon, David;
Leung, Jason S. -Y.;
Lewis, Antony;
Li, Yaqiong;
Li, Zack;
Limon, Michele;
Linder, Eric;
Lopez-Caraballo, Carlos;
Louis, Thibaut;
Lowry, Lindsay;
Lungu, Marius;
Madhavacheril, Mathew;
Mak, Daisy;
Maldonado, Felipe;
Mani, Hamdi;
Mates, Ben;
Matsuda, Frederick;
Maurin, Loïc;
Mauskopf, Phil;
May, Andrew;
McCallum, Nialh;
McKenney, Chris;
McMahon, Jeff;
Meerburg, P. Daniel;
Meyers, Joel;
Miller, Amber;
Mirmelstein, Mark;
Moodley, Kavilan;
Munchmeyer, Moritz;
Munson, Charles;
Naess, Sigurd;
Nati, Federico;
Navaroli, Martin;
Newburgh, Laura;
Nguyen, Ho Nam;
Niemack, Michael;
Nishino, Haruki;
Orlowski-Scherer, John;
Page, Lyman;
Partridge, Bruce;
Peloton, Julien;
Perrotta, Francesca;
Piccirillo, Lucio;
Pisano, Giampaolo;
Poletti, Davide;
Puddu, Roberto;
Puglisi, Giuseppe;
Raum, Chris;
Reichardt, Christian L.;
Remazeilles, Mathieu;
Rephaeli, Yoel;
Riechers, Dominik;
Rojas, Felipe;
Roy, Anirban;
Sadeh, Sharon;
Sakurai, Yuki;
Salatino, Maria;
Rao, Mayuri Sathyanarayana;
Schaan, Emmanuel;
Schmittfull, Marcel;
Sehgal, Neelima;
Seibert, Joseph;
Seljak, Uros;
Sherwin, Blake;
Shimon, Meir;
Sierra, Carlos;
Sievers, Jonathan;
Sikhosana, Precious;
Silva-Feaver, Maximiliano;
Simon, Sara M.;
Sinclair, Adrian;
Siritanasak, Praween;
Smith, Kendrick;
Smith, Stephen R.;
Spergel, David;
Staggs, Suzanne T.;
Stein, George;
Stevens, Jason R.;
Stompor, Radek;
Suzuki, Aritoki;
Tajima, Osamu;
Takakura, Satoru;
Teply, Grant;
Thomas, Daniel B.;
Thorne, Ben;
Thornton, Robert;
Trac, Hy;
Tsai, Calvin;
Tucker, Carole;
Ullom, Joel;
Vagnozzi, Sunny;
van Engelen, Alexander;
Van Lanen, Jeff;
Van Winkle, Daniel D.;
Vavagiakis, Eve M.;
Vergès, Clara;
Vissers, Michael;
Wagoner, Kasey;
Walker, Samantha;
Ward, Jon;
Westbrook, Ben;
Whitehorn, Nathan;
Williams, Jason;
Williams, Joel;
Wollack, Edward J.;
Xu, Zhilei;
Yu, Byeonghee;
Yu, Cyndia;
Zago, Fernando;
Zhang, Hezi;
Zhu, Ningfeng
Submitted: 2018-08-22, last modified: 2019-03-01
The Simons Observatory (SO) is a new cosmic microwave background experiment
being built on Cerro Toco in Chile, due to begin observations in the early
2020s. We describe the scientific goals of the experiment, motivate the design,
and forecast its performance. SO will measure the temperature and polarization
anisotropy of the cosmic microwave background in six frequency bands: 27, 39,
93, 145, 225 and 280 GHz. The initial configuration of SO will have three
small-aperture 0.5-m telescopes (SATs) and one large-aperture 6-m telescope
(LAT), with a total of 60,000 cryogenic bolometers. Our key science goals are
to characterize the primordial perturbations, measure the number of
relativistic species and the mass of neutrinos, test for deviations from a
cosmological constant, improve our understanding of galaxy evolution, and
constrain the duration of reionization. The SATs will target the largest
angular scales observable from Chile, mapping ~10% of the sky to a white noise
level of 2 $\mu$K-arcmin in combined 93 and 145 GHz bands, to measure the
primordial tensor-to-scalar ratio, $r$, at a target level of $\sigma(r)=0.003$.
The LAT will map ~40% of the sky at arcminute angular resolution to an expected
white noise level of 6 $\mu$K-arcmin in combined 93 and 145 GHz bands,
overlapping with the majority of the LSST sky region and partially with DESI.
With up to an order of magnitude lower polarization noise than maps from the
Planck satellite, the high-resolution sky maps will constrain cosmological
parameters derived from the damping tail, gravitational lensing of the
microwave background, the primordial bispectrum, and the thermal and kinematic
Sunyaev-Zel'dovich effects, and will aid in delensing the large-angle
polarization signal to measure the tensor-to-scalar ratio. The survey will also
provide a legacy catalog of 16,000 galaxy clusters and more than 20,000
extragalactic sources.
[11]
oai:arXiv.org:1808.05152 [pdf] - 1733920
Studies of Systematic Uncertainties for Simons Observatory: Optical
Effects and Sensitivity Considerations
Gallardo, Patricio A.;
Gudmundsson, Jon;
Koopman, Brian J.;
Matsuda, Frederick T.;
Simon, Sara M.;
Ali, Aamir;
Bryan, Sean;
Chinone, Yuji;
Coppi, Gabriele;
Cothard, Nicholas;
Devlin, Mark J.;
Dicker, Simon;
Fabbian, Giulio;
Galitzki, Nicholas;
Hill, Charles A.;
Keating, Brian;
Kusaka, Akito;
Lashner, Jacob;
Lee, Adrian T.;
Limon, Michele;
Mauskopf, Philip D.;
McMahon, Jeff;
Nati, Federico;
Niemack, Michael D.;
Orlowski-Scherer, John L.;
Parshley, Stephen C.;
Puglisi, Giuseppe;
Reichardt, Christian L;
Salatino, Maria;
Staggs, Suzanne;
Suzuki, Aritoki;
Vavagiakis, Eve M.;
Wollack, Edward J.;
Xu, Zhilei;
Zhu, Ningfeng
Submitted: 2018-08-15
The Simons Observatory (SO) is a new experiment that aims to measure the
cosmic microwave background (CMB) in temperature and polarization. SO will
measure the polarized sky over a large range of microwave frequencies and
angular scales using a combination of small ($\sim0.5 \, \rm m$) and large
($\sim 6\, \rm m $) aperture telescopes and will be located in the Atacama
Desert in Chile. This work is part of a series of papers studying calibration,
sensitivity, and systematic errors for SO. In this paper, we discuss current
efforts to model optical systematic effects, how these have been used to guide
the design of the SO instrument, and how these studies can be used to inform
instrument design of future experiments like CMB-S4. While optical systematics
studies are underway for both the small aperture and large aperture telescopes,
we limit the focus of this paper to the more mature large aperture telescope
design for which our studies include: pointing errors, optical distortions,
beam ellipticity, cross-polar response, instrumental polarization rotation and
various forms of sidelobe pickup.
[12]
oai:arXiv.org:1808.05101 [pdf] - 1834030
Far Sidelobes from Baffles and Telescope Support Structures in the
Atacama Cosmology Telescope
Submitted: 2018-08-15
The Atacama Cosmology Telescope (ACT) is a 6 m telescope located in the
Atacama Desert, designed to measure the cosmic microwave background (CMB) with
arcminute resolution. ACT, with its third generation polarization sensitive
array, Advanced ACTPol, is being used to measure the anisotropies of the CMB in
five frequency bands in large areas of the sky ($\sim 15,000$ $\rm deg^2$).
These measurements are designed to characterize the large scale structure of
the universe, test cosmological models and constrain the sum of the neutrino
masses. As the sensitivity of these wide surveys increases, the control and
validation of the far sidelobe response becomes increasingly important and is
particularly challenging as multiple reflections, spillover, diffraction and
scattering become difficult to model and characterize at the required levels.
In this work, we present a ray trace model of the ACT upper structure which is
used to describe much of the observed far sidelobe pattern. This model combines
secondary mirror spillover measurements with a 3D CAD model based on
photogrammetry measurements to simulate the beam of the camera and the comoving
ground shield. This simulation shows qualitative agreement with physical optics
tools and features observed in far sidelobe measurements. We present this
method as an efficient first-order calculation that, although it does not
capture all diffraction effects, informs interactions between the structural
components of the telescope and the optical path, which can then be combined
with more computationally intensive physical optics calculations. This method
can be used to predict sidelobe patterns in the design stage of future optical
systems such as the Simons Observatory, CCAT-prime, and CMB Stage IV.
[13]
oai:arXiv.org:1807.06675 [pdf] - 1718622
CCAT-prime: a novel telescope for submillimeter astronomy
Parshley, Stephen C.;
Kronshage, Jörg;
Blair, James;
Herter, Terry;
Nolta, Mike;
Stacey, Gordon J.;
Bazarko, Andrew;
Bertoldi, Frank;
Bustos, Ricardo;
Campbell, Donald B.;
Chapman, Scott;
Cothard, Nicholas;
Devlin, Mark;
Erler, Jens;
Fich, Michel;
Gallardo, Patricio A.;
Giovanelli, Riccardo;
Graf, Urs;
Gramke, Scott;
Haynes, Martha P.;
Hills, Richard;
Limon, Michele;
Mangum, Jeffrey G.;
McMahon, Jeff;
Niemack, Michael D.;
Nikola, Thomas;
Omlor, Markus;
Riechers, Dominik A.;
Steeger, Karl;
Stutzki, Jürgen;
Vavagiakis, Eve M.
Submitted: 2018-07-17
The CCAT-prime telescope is a 6-meter aperture, crossed-Dragone telescope,
designed for millimeter and sub-millimeter wavelength observations. It will be
located at an altitude of 5600 meters, just below the summit of Cerro
Chajnantor in the high Atacama region of Chile. The telescope's unobscured
optics deliver a field of view of almost 8 degrees over a large, flat focal
plane, enabling it to accommodate current and future instrumentation fielding
>100k diffraction-limited beams for wavelengths less than a millimeter. The
mount is a novel design with the aluminum-tiled mirrors nested inside the
telescope structure. The elevation housing has an integrated shutter that can
enclose the mirrors, protecting them from inclement weather. The telescope is
designed to co-host multiple instruments over its nominal 15 year lifetime. It
will be operated remotely, requiring minimum maintenance and on-site activities
due to the harsh working conditions on the mountain. The design utilizes
nickel-iron alloy (Invar) and carbon-fiber-reinforced polymer (CFRP) materials
in the mirror support structure, achieving a relatively temperature-insensitive
mount. We discuss requirements, specifications, critical design elements, and
the expected performance of the CCAT-prime telescope. The telescope is being
built by CCAT Observatory, Inc., a corporation formed by an international
partnership of universities. More information about CCAT and the CCAT-prime
telescope can be found at www.ccatobservatory.org.
[14]
oai:arXiv.org:1807.06019 [pdf] - 1717280
Optimizing the Efficiency of Fabry-Perot Interferometers with
Silicon-Substrate Mirrors
Cothard, Nicholas F.;
Abe, Mahiro;
Nikola, Thomas;
Stacey, Gordon J.;
Cortes-Medellin, German;
Gallardo, Patricio A.;
Koopman, Brian J.;
Niemack, Michael D.;
Parshley, Stephen C.;
Vavagiakis, Eve M.;
Vetter, Kenneth J.
Submitted: 2018-07-16
We present the novel design of microfabricated, silicon-substrate based
mirrors for use in cryogenic Fabry-Perot Interferometers (FPIs) for the mid-IR
to sub-mm/mm wavelength regime. One side of the silicon substrate will have a
double-layer metamaterial anti-reflection coating (ARC) anisotropically etched
into it and the other side will be metalized with a reflective mesh pattern.
The double-layer ARC ensures a reflectance of less than 1% at the surface
substrate over the FPI bandwidth. This low reflectance is required to achieve
broadband capability and to mitigate contaminating resonances from the silicon
surface. Two silicon substrates with their metalized surfaces facing each other
and held parallel with an adjustable separation will compose the FPI. To create
an FPI with nearly uniform finesse over the FPI bandwidth, we use a combination
of inductive and capacitive gold meshes evaporated onto the silicon substrate.
We also consider the use of niobium as a superconducting reflective mesh for
long wavelengths to eliminate ohmic losses at each reflection in the resonating
cavity of the FPI and thereby increase overall transmission. We develop these
silicon-substrate based FPIs for use in ground (e.g. CCAT-prime), air (e.g.
HIRMES), and future space-based telescopes (e.g. the Origins Space Telescope
concept). Such FPIs are well suited for spectroscopic imaging with the upcoming
large IR/sub-mm/mm TES bolometer detector arrays. Here we present the
fabrication and performance of multi-layer, plasma-etched, silicon metamaterial
ARC, as well as models of the mirrors and FPIs.
[15]
oai:arXiv.org:1807.04354 [pdf] - 1724215
CCAT-prime: Science with an Ultra-widefield Submillimeter Observatory at
Cerro Chajnantor
Stacey, G. J.;
Aravena, M.;
Basu, K.;
Battaglia, N.;
Beringue, B.;
Bertoldi, F.;
Bond, J. R.;
Breysse, P.;
Bustos, R.;
Chapman, S.;
Chung, D. T.;
Cothard, N.;
Erler, J.;
Fich, M.;
Foreman, S.;
Gallardo, P.;
Giovanelli, R.;
Graf, U. U.;
Haynes, M. P.;
Herrera-Camus, R.;
Herter, T. L.;
Hložek, R.;
Johnstone, D.;
Keating, L.;
Magnelli, B.;
Meerburg, D.;
Meyers, J.;
Murray, N.;
Niemack, M.;
Nikola, T.;
Nolta, M.;
Parshley, S. C.;
Riechers, D.;
Schilke, P.;
Scott, D.;
Stein, G.;
Stevens, J.;
Stutzki, J.;
Vavagiakis, E. M.;
Viero, M. P.
Submitted: 2018-07-11
We present the detailed science case, and brief descriptions of the telescope
design, site, and first light instrument plans for a new ultra-wide field
submillimeter observatory, CCAT-prime, that we are constructing at a 5600 m
elevation site on Cerro Chajnantor in northern Chile. Our science goals are to
study star and galaxy formation from the epoch of reionization to the present,
investigate the growth of structure in the Universe, improve the precision of
B-mode CMB measurements, and investigate the interstellar medium and star
formation in the Galaxy and nearby galaxies through spectroscopic,
polarimetric, and broadband surveys at wavelengths from 200 um to 2 mm. These
goals are realized with our two first light instruments, a large field-of-view
(FoV) bolometer-based imager called Prime-Cam (that has both camera and an
imaging spectrometer modules), and a multi-beam submillimeter heterodyne
spectrometer, CHAI. CCAT-prime will have very high surface accuracy and very
low system emissivity, so that combined with its wide FoV at the unsurpassed
CCAT site our telescope/instrumentation combination is ideally suited to pursue
this science. The CCAT-prime telescope is being designed and built by Vertex
Antennentechnik GmbH. We expect to achieve first light in the spring of 2021.
[16]
oai:arXiv.org:1807.00058 [pdf] - 1839608
Prime-Cam: A first-light instrument for the CCAT-prime telescope
Vavagiakis, Eve M.;
Ahmed, Zeeshan;
Ali, Aamir;
Basu, Kaustuv;
Battaglia, Nicholas;
Bertoldi, Frank;
Bond, Richard;
Bustos, Ricardo;
Chapman, Scott C.;
Chung, Dongwoo;
Coppi, Gabriele;
Cothard, Nicholas F.;
Dicker, Simon;
Duell, Cody J.;
Duff, Shannon M.;
Erler, Jens;
Fich, Michel;
Galitzki, Nicholas;
Gallardo, Patricio A.;
Henderson, Shawn W.;
Herter, Terry L.;
Hilton, Gene;
Hubmayr, Johannes;
Irwin, Kent D.;
Koopman, Brian J.;
McMahon, Jeffrey;
Murray, Norman;
Niemack, Michael D.;
Nikolas, Thomas;
Nolta, Michael;
Orlowski-Scherer, John L.;
Parshley, Stephen C.;
Riechers, Dominik A.;
Rossi, Kayla;
Scott, Douglas;
Sierra, Carlos;
Silva-Feaver, Max;
Simon, Sara M.;
Stacey, Gordon J.;
Stevens, Jason R.;
Ullom, Joel N.;
Vissers, Michael R.;
Walker, Samantha;
Wollack, Edward J.;
Xu, Zhilei;
Zhu, Ningfeng
Submitted: 2018-06-29
CCAT-prime will be a 6-meter aperture telescope operating from sub-mm to mm
wavelengths, located at 5600 meters elevation on Cerro Chajnantor in the
Atacama Desert in Chile. Its novel crossed-Dragone optical design will deliver
a high throughput, wide field of view capable of illuminating much larger
arrays of sub-mm and mm detectors than can existing telescopes. We present an
overview of the motivation and design of Prime-Cam, a first-light instrument
for CCAT-prime. Prime-Cam will house seven instrument modules in a 1.8 meter
diameter cryostat, cooled by a dilution refrigerator. The optical elements will
consist of silicon lenses, and the instrument modules can be individually
optimized for particular science goals. The current design enables both
broadband, dual-polarization measurements and narrow-band, Fabry-Perot
spectroscopic imaging using multichroic transition-edge sensor (TES) bolometers
operating between 190 and 450 GHz. It also includes broadband kinetic induction
detectors (KIDs) operating at 860 GHz. This wide range of frequencies will
allow excellent characterization and removal of galactic foregrounds, which
will enable precision measurements of the sub-mm and mm sky. Prime-Cam will be
used to constrain cosmology via the Sunyaev-Zeldovich effects, map the
intensity of [CII] 158 $\mu$m emission from the Epoch of Reionization, measure
Cosmic Microwave Background polarization and foregrounds, and characterize the
star formation history over a wide range of redshifts. More information about
CCAT-prime can be found at www.ccatobservatory.org.
[17]
oai:arXiv.org:1710.08456 [pdf] - 1684058
Magnetic Sensitivity of AlMn TESes and Shielding Considerations for
Next-Generation CMB Surveys
Vavagiakis, E. M.;
Henderson, S. W.;
Zheng, K.;
Cho, H. -M.;
Cothard, N. F.;
Dober, B.;
Duff, S. M.;
Gallardo, P. A.;
Hilton, G.;
Hubmayr, J.;
Irwin, K. D.;
Koopman, B. J.;
Li, D.;
Nati, F.;
Niemack, M. D.;
Reintsema, C. D.;
Simon, S.;
Stevens, J. R.;
Suzuki, A.;
Westbrook, B.
Submitted: 2017-10-23, last modified: 2018-05-16
In the next decade, new ground-based Cosmic Microwave Background (CMB)
experiments such as Simons Observatory (SO), CCAT-prime, and CMB-S4 will
increase the number of detectors observing the CMB by an order of magnitude or
more, dramatically improving our understanding of cosmology and astrophysics.
These projects will deploy receivers with as many as hundreds of thousands of
transition edge sensor (TES) bolometers coupled to Superconducting Quantum
Interference Device (SQUID)-based readout systems. It is well known that
superconducting devices such as TESes and SQUIDs are sensitive to magnetic
fields. However, the effects of magnetic fields on TESes are not easily
predicted due to the complex behavior of the superconducting transition, which
motivates direct measurements of the magnetic sensitivity of these devices. We
present comparative four-lead measurements of the critical temperature versus
applied magnetic field of AlMn TESes varying in geometry, doping, and leg
length, including Advanced ACT (AdvACT) and POLARBEAR-2/Simons Array
bolometers. Molybdenum-copper bilayer ACTPol TESes are also tested and are
found to be more sensitive to magnetic fields than the AlMn devices. We present
an observation of weak-link-like behavior in AlMn TESes at low critical
currents. We also compare measurements of magnetic sensitivity for time
division multiplexing SQUIDs and frequency division multiplexing microwave
rf-SQUIDs. We discuss the implications of our measurements on the magnetic
shielding required for future experiments that aim to map the CMB to
near-fundamental limits.
[18]
oai:arXiv.org:1711.02594 [pdf] - 1676753
Advanced ACTPol Low Frequency Array: Readout and Characterization of
Prototype 27 and 39 GHz Transition Edge Sensors
Koopman, Brian J.;
Cothard, Nicholas F.;
Choi, Steve K.;
Crowley, Kevin T.;
Duff, Shannon M.;
Henderson, Shawn W.;
Ho, Shuay-Pwu Patty;
Hubmayr, Johannes;
Gallardo, Patricio A.;
Nati, Federico;
Niemack, Michael D.;
Simon, Sara M.;
Staggs, Suzanne T.;
Stevens, Jason R.;
Vavagiakis, Eve M.;
Wollack, Edward J.
Submitted: 2017-11-07, last modified: 2018-05-02
Advanced ACTPol (AdvACT) is a third generation polarization upgrade to the
Atacama Cosmology Telescope, designed to observe the cosmic microwave
background (CMB). AdvACT expands on the 90 and 150 GHz transition edge sensor
(TES) bolometer arrays of the ACT Polarimeter (ACTPol), adding both high
frequency (HF, 150/230 GHz) and low frequency (LF, 27/39 GHz) multichroic
arrays. The addition of the high and low frequency detectors allows for the
characterization of synchrotron and spinning dust emission at the low
frequencies and foreground emission from galactic dust and dusty star forming
galaxies at the high frequencies. The increased spectral coverage of AdvACT
will enable a wide range of CMB science, such as improving constraints on dark
energy, the sum of the neutrino masses, and the existence of primordial
gravitational waves. The LF array will be the final AdvACT array, replacing one
of the MF arrays for a single season. Prior to the fabrication of the final LF
detector array, we designed and characterized prototype TES bolometers.
Detector geometries in these prototypes are varied in order to inform and
optimize the bolometer designs for the LF array, which requires significantly
lower noise levels and saturation powers (as low as ${\sim}1$ pW) than the
higher frequency detectors. Here we present results from tests of the first LF
prototype TES detectors for AdvACT, including measurements of the saturation
power, critical temperature, thermal conductance and time constants. We also
describe the modifications to the time-division SQUID readout architecture
compared to the MF and HF arrays.
[19]
oai:arXiv.org:1610.07655 [pdf] - 1567595
Deep Reactive Ion Etched Anti-Reflection Coatings for Sub-millimeter
Silicon Optics
Gallardo, Patricio A.;
Koopman, Brian J.;
Cothard, Nicholas;
Bruno, Sarah Marie M.;
Cortes-Medellin, German;
Marchetti, Galen;
Miller, Kevin H.;
Mockler, Brenna;
Niemack, Michael D.;
Stacey, Gordon;
Wollack, Edward J.
Submitted: 2016-10-24
Refractive optical elements are widely used in millimeter and sub-millimeter
astronomical telescopes. High resistivity silicon is an excellent material for
dielectric lenses given its low loss-tangent, high thermal conductivity and
high index of refraction. The high index of refraction of silicon causes a
large Fresnel reflectance at the vacuum-silicon interface (up to 30%), which
can be reduced with an anti-reflection (AR) coating. In this work we report
techniques for efficiently AR coating silicon at sub-millimeter wavelengths
using Deep Reactive Ion Etching (DRIE) and bonding the coated silicon to
another silicon optic. Silicon wafers of 100 mm diameter (1 mm thick) were
coated and bonded using the Silicon Direct Bonding technique at high
temperature (1100 C). No glue is used in this process. Optical tests using a
Fourier Transform Spectrometer (FTS) show sub-percent reflections for a
single-layer DRIE AR coating designed for use at 320 microns on a single wafer.
Cryogenic (10 K) measurements of a bonded pair of AR-coated wafers also reached
sub-percent reflections. A prototype two-layer DRIE AR coating to reduce
reflections and increase bandwidth is presented and plans for extending this
approach are discussed.
[20]
oai:arXiv.org:1607.06064 [pdf] - 1531072
Readout of two-kilopixel transition-edge sensor arrays for Advanced
ACTPol
Henderson, Shawn W.;
Stevens, Jason R.;
Amiri, Mandana;
Austermann, Jason;
Beall, James A.;
Chaudhuri, Saptarshi;
Cho, Hsiao-Mei;
Choi, Steve K.;
Cothard, Nicholas F.;
Crowley, Kevin T.;
Duff, Shannon M.;
Fitzgerald, Colin P.;
Gallardo, Patricio A.;
Halpern, Mark;
Hasselfield, Matthew;
Hilton, Gene;
Ho, Shuay-Pwu Patty;
Hubmayr, Johannes;
Irwin, Kent D.;
Koopman, Brian J.;
Li, Dale;
Li, Yaqiong;
McMahon, Jeff;
Nati, Federico;
Niemack, Michael D.;
Reintsema, Carl D.;
Salatino, Maria;
Schillaci, Alessandro;
Schmitt, Benjamin L.;
Simon, Sara M.;
Staggs, Suzanne T.;
Vavagiakis, Eve M.;
Ward, Jonathan T.
Submitted: 2016-07-20
Advanced ACTPol is an instrument upgrade for the six-meter Atacama Cosmology
Telescope (ACT) designed to measure the cosmic microwave background (CMB)
temperature and polarization with arcminute-scale angular resolution. To
achieve its science goals, Advanced ACTPol utilizes a larger readout
multiplexing factor than any previous CMB experiment to measure detector arrays
with approximately two thousand transition-edge sensor (TES) bolometers in each
150 mm detector wafer. We present the implementation and testing of the
Advanced ACTPol time-division multiplexing readout architecture with a 64-row
multiplexing factor. This includes testing of individual multichroic detector
pixels and superconducting quantum interference device (SQUID) multiplexing
chips as well as testing and optimizing of the integrated readout electronics.
In particular, we describe the new automated multiplexing SQUID tuning
procedure developed to select and optimize the thousands of SQUID parameters
required to readout each Advanced ACTPol array. The multichroic detector pixels
in each array use separate channels for each polarization and each of the two
frequencies, such that four TESes must be read out per pixel. Challenges
addressed include doubling the number of detectors per multiplexed readout
channel compared to ACTPol and optimizing the Nyquist inductance to minimize
detector and SQUID noise aliasing.