Normalized to: Coppi, C.
[1]
oai:arXiv.org:0912.3689 [pdf] - 125372
Status of the CRESST Dark Matter Search
Schmaler, J.;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Lang, R. F.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2009-12-18
The CRESST experiment aims for a detection of dark matter in the form of
WIMPs. These particles are expected to scatter elastically off the nuclei of a
target material, thereby depositing energy on the recoiling nucleus. CRESST
uses scintillating CaWO4 crystals as such a target. The energy deposited by an
interacting particle is primarily converted to phonons which are detected by
transition edge sensors. In addition, a small fraction of the interaction
energy is emitted from the crystals in the form of scintillation light which is
measured in coincidence with the phonon signal by a separate cryogenic light
detector for each target crystal. The ratio of light to phonon energy permits
the discrimination between the nuclear recoils expected from WIMPs and events
from radioactive backgrounds which primarily lead to electron recoils. CRESST
has shown the success of this method in a commissioning run in 2007 and, since
then, further investigated possibilities for an even better suppression of
backgrounds. Here, we report on a new class of background events observed in
the course of this work. The consequences of this observation are discussed and
we present the current status of the experiment.
[2]
oai:arXiv.org:0912.0170 [pdf] - 971925
Composite CaWO4 Detectors for the CRESST-II Experiment
Kiefer, M.;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Lang, R. F.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2009-12-01
CRESST-II, standing for Cryogenic Rare Events Search with Superconducting
Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS
facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order
to detect WIMPs by elastic scattering off nuclei, generating phononic lattice
excitations and scintillation light. The thermometers used in the experiment
consist of a tungsten thin-film structure evaporated onto the CaWO4 absorber
crystal. The process of evaporation causes a decrease in the scintillation
light output. This, together with the need of a big-scale detector production
for the upcoming EURECA experiment lead to investigations for producing
thermometers on smaller crystals which are glued onto the absorber crystal. In
our Run 31 we tested composite detectors for the first time in the Gran Sasso
setup. They seem to produce higher light yields as hoped and could provide an
additional time based discrimination mechanism for low light yield clamp
events.
[3]
oai:arXiv.org:0905.4282 [pdf] - 24648
Electron and Gamma Background in CRESST Detectors
Lang, R. F.;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Majorovits, B.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2009-05-26
The CRESST experiment monitors 300g CaWO_4 crystals as targets for particle
interactions in an ultra low background environment. In this paper, we analyze
the background spectra that are recorded by three detectors over many weeks of
data taking. Understanding these spectra is mandatory if one wants to further
reduce the background level, and allows us to cross-check the calibration of
the detectors. We identify a variety of sources, such as intrinsic
contaminations due to primordial radioisotopes and cosmogenic activation of the
target material. In particular, we detect a 3.6keV X-ray line from the decay of
41-Ca with an activity of (26\pm4)\mu Bq, corresponding to a ratio
41-Ca/40-Ca=(2.2\pm0.3)\times10^{-16}.
[4]
oai:arXiv.org:0903.4687 [pdf] - 22801
Discrimination of Recoil Backgrounds in Scintillating Calorimeters
Lang, R. F.;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2009-03-26
The alpha decay of $\n{{}^{210}Po}$ is a dangerous background to rare event
searches. Here, we describe observations related to this alpha decay in the
Cryogenic Rare Event Search with Superconducting Thermometers (CRESST). We find
that lead nuclei show a scintillation light yield in our $\n{CaWO_4}$ crystals
of $0.0142\pm0.0013$ relative to electrons of the same energy. We describe a
way to discriminate this source of nuclear recoil background by means of a
scintillating foil, and demonstrate its effectiveness. This leads to an
observable difference in the pulse shape of the light detector, which can be
used to tag these events. Differences in pulse shape of the phonon detector
between lead and electron recoils are also extracted, opening the window to
future additional background suppression techniques based on pulse shape
discrimination in such experiments.
[5]
oai:arXiv.org:0809.1829 [pdf] - 16181
Commissioning Run of the CRESST-II Dark Matter Search
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Lang, R. F.;
Majorovits, B.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Proebst, F.;
Rau, W.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schaeffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2008-09-10, last modified: 2009-02-16
The CRESST cryogenic direct dark matter search at Gran Sasso, searching for
WIMPs via nuclear recoil, has been upgraded to CRESST-II by several changes and
improvements.We present the results of a commissioning run carried out in 2007.
The basic element of CRESST-II is a detector module consisting of a large (~
300 g) CaWO_4 crystal and a very sensitive smaller (~ 2 g) light detector to
detect the scintillation light from the CaWO_4.Information from light-quenching
factor studies allows the definition of a region of the energy-light yield
plane which corresponds to tungsten recoils. A neutron test is reported which
supports the principle of using the light yield to identify the recoiling
nucleus.
Data obtained with two detector modules for a total exposure of 48 kg-days
are presented. Judging by the rate of events in the "all nuclear recoils"
acceptance region the apparatus shows a factor ~ten improvement with respect to
previous results, which we attribute principally to the presence of the neutron
shield.
In the "tungsten recoils" acceptance region three events are found,
corresponding to a rate of 0.063 per kg-day. Standard assumptions on the dark
matter flux, coherent or spin independent interactions,then yield a limit for
WIMP-nucleon scattering of 4.8 \times 10^{-7}pb, at M{WIMP} ~50 GeV.
[6]
oai:arXiv.org:0810.0423 [pdf] - 17016
Cryogenic Composite Detectors for the Dark Matter Experiments CRESST and
EURECA
Roth, S.;
Ciemniak, C.;
Coppi, C.;
Feilitzsch, F. v.;
Guetlein, A.;
Isaila, C.;
Lanfranchi, J. -C.;
Pfister, S.;
Potzel, W.;
Westphal, W.
Submitted: 2008-10-02
Weakly Interacting Massive Particles (WIMPs) are candidates for non-baryonic
Dark Matter. WIMPs are supposed to interact with baryonic matter via scattering
off nuclei producing a nuclear recoil with energies up to a few 10 keV with a
very low interaction rate of ~10^(-6) events per kg of target material and day
in the energy region of interest. The Dark Matter experiment CRESST (Cryogenic
Rare Event Search with Superconducting Thermometers) and the EURECA project
(European Underground Rare Event Calorimeter Array) are aimed at the direct
detection of WIMPs with the help of very sensitive modularised cryogenic
detectors that basically consist of a transition edge sensor (TES) in
combination with a massive absorber crystal. In the CRESST experiment the
search for coherent WIMP-nucleon scattering events is validated by the
detection of two processes. In the scintillating absorber single crystal,
CaWO_4, heat (phonons) and scintillation light are produced and detected with
two independent cryogenic detectors: a phonon channel and a separate light
channel. The development of such cryogenic detectors and the potential
ton-scale production are investigated in this paper. To decouple the TES
production from the choice of the target material in order to avoid heating
cycles of the absorber crystal and to allow pretesting of the TESs, a composite
detector design (CDD) for the detector production has been developed and
studied. An existing thermal detector model has been extended to the CDD, in
order to investigate, understand, and optimize the performance of composite
detectors. This extended model, which has been worked out in detail, can be
expected to provide a considerable help when tailoring composite detectors to
the requirements of various experiments.
[7]
oai:arXiv.org:0810.0132 [pdf] - 16940
Neutron Scattering Facility for Characterization of CRESST and EURECA
Detectors at mK Temperatures
Lanfranchi, J. -C.;
Ciemniak, C.;
Coppi, C.;
von Feilitzsch, F.;
Gütlein, A.;
Hagn, H.;
Isaila, C.;
Jochum, J.;
Kimmerle, M.;
Pfister, S.;
Potzel, W.;
Rau, W.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Scholl, S.;
Usherov, I.;
Westphal, W.
Submitted: 2008-10-01
CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) is an
experiment located at the Gran Sasso underground laboratory and aimed at the
direct detection of dark matter in the form of WIMPs. The setup has just
completed a one year commissioning run in 2007 and is presently starting a
physics run with an increased target mass. Scintillating $\mathrm{CaWO_4}$
single crystals, operated at temperatures of a few millikelvin, are used as
target to detect the tiny nuclear recoil induced by a WIMP. The powerful
background identification and rejection of $\alpha$, e$^{-}$ and $\gamma$
events is realized via the simultaneous measurement of a phonon and a
scintillation signal generated in the $\mathrm{CaWO_4}$ crystal. However,
neutrons could still be misidentified as a WIMP signature. Therefore, a
detailed understanding of the individual recoil behaviour in terms of phonon
generation and scintillation light emission due to scattering on Ca, O or W
nuclei, respectively, is mandatory. The only setup which allows to perform such
measurements at the operating temperature of the CRESST detectors has been
installed at the Maier-Leibnitz-Accelerator Laboratory in Garching and is
presently being commissioned. The design of this neutron scattering facility is
such that it can also be used for other target materials, e.g.
$\mathrm{ZnWO_4}$, $\mathrm{PbWO_4}$ and others as foreseen in the framework of
the future multitarget tonne-scale experiment EURECA (European Underground Rare
Event Calorimeter Array).