sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Cooley, J.

Normalized to: Cooley, J.

32 article(s) in total. 511 co-authors, from 1 to 28 common article(s). Median position in authors list is 18,0.

[1]  oai:arXiv.org:2005.14067  [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration; Amaral, D. W.; Aralis, T.; Aramaki, T.; Arnquist, I. J.; Azadbakht, E.; Banik, S.; Barker, D.; Bathurst, C.; Bauer, D. A.; Bezerra, L. V. S.; Bhattacharyya, R.; Binder, T.; Bowles, M. A.; Brink, P. L.; Bunker, R.; Cabrera, B.; Calkins, R.; Cameron, R. A.; Cartaro, C.; Cerdeño, D. G.; Chang, Y. -Y.; Chen, R.; Chott, N.; Cooley, J.; Coombes, H.; Corbett, J.; Cushman, P.; De Brienne, F.; di Vacri, M. L.; Diamond, M. D.; Fascione, E.; Figueroa-Feliciano, E.; Fink, C. W.; Fouts, K.; Fritts, M.; Gerbier, G.; Germond, R.; Ghaith, M.; Golwala, S. R.; Harris, H. R.; Herbert, N.; Hines, B. A.; Hollister, M. I.; Hong, Z.; Hoppe, E. W.; Hsu, L.; Huber, M. E.; Iyer, V.; Jardin, D.; Jastram, A.; Kelsey, M. H.; Kubik, A.; Kurinsky, N. A.; Lawrence, R. E.; Li, A.; Loer, B.; Asamar, E. Lopez; Lukens, P.; MacDonell, D.; MacFarlane, D. B.; Mahapatra, R.; Mandic, V.; Mast, N.; Mayer, A. J.; Michaud, É. M.; Michielin, E.; Mirabolfathi, N.; Mohanty, B.; Mendoza, J. D. Morales; Nagorny, S.; Nelson, J.; Neog, H.; Novati, V.; Orrell, J. L.; Oser, S. M.; Page, W. A.; Pakarha, P.; Partridge, R.; Podviianiuk, R.; Ponce, F.; Poudel, S.; Pyle, M.; Rau, W.; Reid, E.; Ren, R.; Reynolds, T.; Roberts, A.; Robinson, A. E.; Rogers, H. E.; Saab, T.; Sadoulet, B.; Sander, J.; Sattari, A.; Schnee, R. W.; Scorza, S.; Serfass, B.; Sincavage, D. J.; Stanford, C.; Stein, M.; Street, J.; Toback, D.; Underwood, R.; Verma, S.; Villano, A. N.; von Krosigk, B.; Watkins, S. L.; Wills, L.; Wilson, J. S.; Wilson, M. J.; Winchell, J.; Wright, D. H.; Yellin, S.; Young, B. A.; Yu, T. C.; Zhang, E.; Zhang, H. G.; Zhao, X.; Zheng, L.
Comments: 5 pages + title and references, 3 figures and 1 table
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[2]  oai:arXiv.org:1806.07043  [pdf] - 1944785
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
Comments: 14 pages, 10 figures, 5 tables. v5 contains the extended data release (and documentation) of the CDMSlite Run 2 data as ancillary files
Submitted: 2018-06-19, last modified: 2019-08-16
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
[3]  oai:arXiv.org:1804.10697  [pdf] - 1877835
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Comments: 6 pages + title and references, 6 figures, includes erratum submitted to PRL and data release
Submitted: 2018-04-27, last modified: 2019-05-03
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
[4]  oai:arXiv.org:1808.09098  [pdf] - 1873743
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
Comments:
Submitted: 2018-08-27, last modified: 2019-04-25
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.
[5]  oai:arXiv.org:1805.09942  [pdf] - 1867949
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS Germanium Detectors
Agnese, Robert; Aralis, Taylor; Aramaki, Tsuguo; Arnquist, Isaac; Azadbakht, Elham; Baker, William; Banik, Samir; Barker, D'Ann; Bauer, Dan; Binder, Thomas; Bowles, Michael; Brink, Paul; Bunker, Ray; Cabrera, Blas; Calkins, Robert; Cartaro, Concetta; Cerdeno, David; Chang, Yen-Yung; Cooley, Jodi; Cornell, Brett; Cushman, Priscilla; Di Stefano, Philippe; Doughty, Todd; Fascione, Eleanor; Figueroa, Tali; Fink, Caleb; Fritts, Matt; Gerbier, Gilles; Germond, Richard; Ghaith, Muad; Golwala, Sunil; Harris, Rusty; Hong, Ziqing; Hoppe, Eric; Hsu, Lauren; Huber, Martin; Iyer, Vijay; Jardin, Dan; Jena, Chitrasen; Kelsey, Michael; Kennedy, Allison; Kubik, Andrew; Kurinsky, Noah; Lawrence, Richard; Loer, Ben; Lopez-Asamar, Elias; Lukens, Pat; MacDonell, Danika; Mahapatra, Rupak; Mandic, Vuk; Mast, Nicholas; Miller, Eric; Mirabolfathi, Nader; Mohanty, Bedangadas; Morales, Jorge; Nelson, Jack; Orrell, John; Oser, Scott; Page, William; Partridge, Richard; Pepin, Mark; Ponce, Francisco; Poudel, Sudip; Pyle, Matt; Qiu, Hang; Rau, Wolfgang; Reisetter, Angela; Ren, Tom; Reynolds, Tyler; Roberts, Amy; Robinson, Alan; Rogers, Hannah; Saab, Tarek; Sadoulet, Bernard; Sander, Joel; Scarff, Andrew; Schnee, Richard; Scorza, Silvia; Senapati, Kartik; Serfass, Bruno; Speller, Danielle; Stein, Matthew; Street, Joseph; Tanaka, Hirohisa; Toback, David; Underwood, Ryan; Villano, Anthony; von Krosigk, Belina; Watkins, Samuel; Wilson, Jon; Wilson, Matthew; Winchell, Joshua; Wright, Dennis; Yellin, Steve; Young, Betty; Zhang, Xiaohe; Zhao, Xuji
Comments: 4 Figures, Two data files, One data release description file
Submitted: 2018-05-24, last modified: 2019-04-16
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this result and using TRIM simulations, we extract the first experimentally determined average displacement threshold energy of $\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for the analysis thresholds of future germanium-based dark matter searches.
[6]  oai:arXiv.org:1803.02903  [pdf] - 1724039
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Comments: 22 pages, 17 figures, 1 table, 1 appendix
Submitted: 2018-03-07, last modified: 2018-07-27
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.
[7]  oai:arXiv.org:1707.01632  [pdf] - 1622232
Low-Mass Dark Matter Search with CDMSlite
Comments: 30 Pages, 33 Figures v3 to match published version in PRD. v2 contains public release (and documentation) of the CDMSlite Run 2 data as ancillary files
Submitted: 2017-07-06, last modified: 2018-01-18
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
[8]  oai:arXiv.org:1708.09476  [pdf] - 1587717
Radon Daughter Plate-out Measurements at SNOLAB for Polyethylene and Copper
Comments: 7 pages, 7 figures
Submitted: 2017-08-30, last modified: 2017-11-13
Polyethylene and copper samples were exposed to the underground air at SNOLAB for approximately three months while several environmental factors were monitored. Predictions of the radon-daughter plate-out rate are compared to the resulting surface activities, obtained from high-sensitivity measurements of alpha emissivity using the XIA UltraLo-1800 spectrometer at SMU. From these measurements, we determine an average $^{210}$Pb plate-out rate of 249 and 423 atoms/day/cm$^{2}$ for polyethylene and copper, respectively, when exposed to radon activity of 135 Bq/m$^{3}$ at SNOLAB. A time-dependent model of alpha activity is discussed for these materials placed in similar environmental conditions.
[9]  oai:arXiv.org:1705.04736  [pdf] - 1648564
Input Comparison of Radiogenic Neutron Estimates for Ultra-low Background Experiments
Comments:
Submitted: 2017-05-12
Ultra-low-background experiments address some of the most important open questions in particle physics, cosmology and astrophysics: the nature of dark matter, whether the neutrino is its own antiparticle, and does the proton decay. These rare event searches require well-understood and minimized backgrounds. Simulations are used to understand backgrounds caused by naturally occurring radioactivity in the rock and in every piece of shielding and detector material used in these experiments. Most important are processes like spontaneous fission and ({\alpha},n) reactions in material close to the detectors that can produce neutrons. A comparison study between two dedicated software packages is detailed. The cross section libraries, neutron yields, and spectra from the Mei-Zhang-Hime and the SOURCES-4A codes are presented. The resultant yields and spectra are used as inputs to direct dark matter detector toy models in GEANT4, to study the impact of their differences on background estimates and fits. Although differences in neutron yield calculations up to 50% were seen, there was no systematic difference between the Mei-Hime-Zhang and SOURCES-4A results. Neutron propagation simulations smooth differences in spectral shape and yield, and both tools were found to meet the broad requirements of the low-background community.
[10]  oai:arXiv.org:1610.00006  [pdf] - 1561019
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Comments: SuperCDMS SNOLAB Projected sensitivity reach
Submitted: 2016-09-30
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.
[11]  oai:arXiv.org:1608.08632  [pdf] - 1472452
Dark Sectors 2016 Workshop: Community Report
Alexander, Jim; Battaglieri, Marco; Echenard, Bertrand; Essig, Rouven; Graham, Matthew; Izaguirre, Eder; Jaros, John; Krnjaic, Gordan; Mardon, Jeremy; Morrissey, David; Nelson, Tim; Perelstein, Maxim; Pyle, Matt; Ritz, Adam; Schuster, Philip; Shuve, Brian; Toro, Natalia; Van De Water, Richard G; Akerib, Daniel; An, Haipeng; Aniol, Konrad; Arnquist, Isaac J.; Asner, David M.; Back, Henning O.; Baker, Keith; Baltzell, Nathan; Banerjee, Dipanwita; Batell, Brian; Bauer, Daniel; Beacham, James; Benesch, Jay; Bjorken, James; Blinov, Nikita; Boehm, Celine; Bondí, Mariangela; Bonivento, Walter; Bossi, Fabio; Brodsky, Stanley J.; Budnik, Ran; Bueltmann, Stephen; Bukhari, Masroor H.; Bunker, Raymond; Carpinelli, Massimo; Cartaro, Concetta; Cassel, David; Cavoto, Gianluca; Celentano, Andrea; Chaterjee, Animesh; Chaudhuri, Saptarshi; Chiodini, Gabriele; Cho, Hsiao-Mei Sherry; Church, Eric D.; Cooke, D. A.; Cooley, Jodi; Cooper, Robert; Corliss, Ross; Crivelli, Paolo; Curciarello, Francesca; D'Angelo, Annalisa; Davoudiasl, Hooman; De Napoli, Marzio; De Vita, Raffaella; Denig, Achim; deNiverville, Patrick; Deshpande, Abhay; Dharmapalan, Ranjan; Dobrescu, Bogdan; Donskov, Sergey; Dupre, Raphael; Estrada, Juan; Fegan, Stuart; Ferber, Torben; Field, Clive; Figueroa-Feliciano, Enectali; Filippi, Alessandra; Fornal, Bartosz; Freyberger, Arne; Friedland, Alexander; Galon, Iftach; Gardner, Susan; Girod, Francois-Xavier; Gninenko, Sergei; Golutvin, Andrey; Gori, Stefania; Grab, Christoph; Graziani, Enrico; Griffioen, Keith; Haas, Andrew; Harigaya, Keisuke; Hearty, Christopher; Hertel, Scott; Hewett, JoAnne; Hime, Andrew; Hitlin, David; Hochberg, Yonit; Holt, Roy J.; Holtrop, Maurik; Hoppe, Eric W.; Hossbach, Todd W.; Hsu, Lauren; Ilten, Phil; Incandela, Joe; Inguglia, Gianluca; Irwin, Kent; Jaegle, Igal; Johnson, Robert P.; Kahn, Yonatan; Kalicy, Grzegorz; Kang, Zhong-Bo; Khachatryan, Vardan; Kozhuharov, Venelin; Krasnikov, N. V.; Kubarovsky, Valery; Kuflik, Eric; Kurinsky, Noah; Laha, Ranjan; Lanfranchi, Gaia; Li, Dale; Lin, Tongyan; Lisanti, Mariangela; Liu, Kun; Liu, Ming; Loer, Ben; Loomba, Dinesh; Lyubovitskij, Valery E.; Manalaysay, Aaron; Mandaglio, Giuseppe; Mans, Jeremiah; Marciano, W. J.; Markiewicz, Thomas; Marsicano, Luca; Maruyama, Takashi; Matveev, Victor A.; McKeen, David; McKinnon, Bryan; McKinsey, Dan; Merkel, Harald; Mock, Jeremy; Monzani, Maria Elena; Moreno, Omar; Nantais, Corina; Paul, Sebouh; Peskin, Michael; Poliakov, Vladimir; Polosa, Antonio D; Pospelov, Maxim; Rachek, Igor; Radics, Balint; Raggi, Mauro; Randazzo, Nunzio; Ratcliff, Blair; Rizzo, Alessandro; Rizzo, Thomas; Robinson, Alan; Rubbia, Andre; Rubin, David; Rueter, Dylan; Saab, Tarek; Santopinto, Elena; Schnee, Richard; Shelton, Jessie; Simi, Gabriele; Simonyan, Ani; Sipala, Valeria; Slone, Oren; Smith, Elton; Snowden-Ifft, Daniel; Solt, Matthew; Sorensen, Peter; Soreq, Yotam; Spagnolo, Stefania; Spencer, James; Stepanyan, Stepan; Strube, Jan; Sullivan, Michael; Tadepalli, Arun S.; Tait, Tim; Taiuti, Mauro; Tanedo, Philip; Tayloe, Rex; Thaler, Jesse; Tran, Nhan V.; Tulin, Sean; Tully, Christopher G.; Uemura, Sho; Ungaro, Maurizio; Valente, Paolo; Vance, Holly; Vavra, Jerry; Volansky, Tomer; von Krosigk, Belina; Whitbeck, Andrew; Williams, Mike; Wittich, Peter; Wojtsekhowski, Bogdan; Xue, Wei; Yoon, Jong Min; Yu, Hai-Bo; Yu, Jaehoon; Yu, Tien-Tien; Zhang, Yue; Zhao, Yue; Zhong, Yiming; Zurek, Kathryn
Comments: 66 pages, 15 figures, 3 tables. Workshop website and agenda: http://www-conf.slac.stanford.edu/darksectors2016/ https://indico.cern.ch/event/507783/ Editors: J. Alexander, M. Battaglieri, B. Echenard, R. Essig, M. Graham, E. Izaguirre, J. Jaros, G. Krnjaic, J. Mardon, D. Morrissey, T. Nelson, M. Perelstein, M. Pyle, A. Ritz, P. Schuster, B. Shuve, N. Toro, R. Van De Water
Submitted: 2016-08-30
This report, based on the Dark Sectors workshop at SLAC in April 2016, summarizes the scientific importance of searches for dark sector dark matter and forces at masses beneath the weak-scale, the status of this broad international field, the important milestones motivating future exploration, and promising experimental opportunities to reach these milestones over the next 5-10 years.
[12]  oai:arXiv.org:1503.03379  [pdf] - 1458536
Dark matter effective field theory scattering in direct detection experiments
Comments: Newest version includes erratum
Submitted: 2015-03-11, last modified: 2016-08-16
We examine the consequences of the effective field theory (EFT) of dark matter-nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. We also discuss the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.
[13]  oai:arXiv.org:1509.02448  [pdf] - 1371572
WIMP-Search Results from the Second CDMSlite Run
Comments: 6 pages, 4 figures. v2 Matches the accepted version in PRL
Submitted: 2015-09-08, last modified: 2016-03-09
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
[14]  oai:arXiv.org:1504.05871  [pdf] - 1293576
Improved WIMP-search reach of the CDMS II germanium data
Comments: 25 pages, 15 figures, slightly updated organization and text consistent with PRD referee process, Fig. 14 updated
Submitted: 2015-04-22, last modified: 2015-10-13
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector WIMP-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there were zero candidate events above a deposited energy of 10 keV and 6 events in the lower-threshold analysis. This yielded minimum WIMP-nucleon spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and $1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$ WIMPs, respectively. This improves the previous CDMS II result by a factor of 2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.
[15]  oai:arXiv.org:1409.3270  [pdf] - 969775
First direct limits on Lightly Ionizing Particles with electric charge less than $e/6$
Comments: 5 pages, 6 figures, submitted to PRL
Submitted: 2014-09-10, last modified: 2015-02-03
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six stacked detectors of each of two of the CDMS II towers found no candidates, thereby excluding new parameter space for particles with electric charges between $e$/6 and $e$/200.
[16]  oai:arXiv.org:1410.4960  [pdf] - 903873
Overview of Non-Liquid Noble Direct Detection Dark Matter Experiments
Comments: 19 pages, 1 figure. In Proceedings of the 13th International Conference on Topics in Astroparticle and Underground Physics, TAUP 2013
Submitted: 2014-10-18, last modified: 2014-11-03
In the last few years many advances have been made in the field of dark matter direct detection. In this article I will review the progress and status of experiments that employ detection techniques that do not use noble liquids. First, I will give an introduction to the field of dark matter and discuss the background challenges that confront all dark matter experiments. I will also discuss various detection techniques employed by the current generation and the next generation of dark matter experiments. Finally, I will discuss recent results and the status of current and future direct detection experiments.
[17]  oai:arXiv.org:1410.1003  [pdf] - 975596
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
Comments: 12 pages, 12 figures, submitted to PRD
Submitted: 2014-10-03
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
[18]  oai:arXiv.org:1402.7137  [pdf] - 841566
Search for Low-Mass WIMPs with SuperCDMS
Comments: 6 pages, 4 figures; figure 1 updated, submitted to Phys. Rev. Lett
Submitted: 2014-02-28, last modified: 2014-03-12
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.
[19]  oai:arXiv.org:1309.3259  [pdf] - 779590
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment
Comments: 7 pages, 4 figures
Submitted: 2013-09-12, last modified: 2013-12-20
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were collected with a single 0.6 kg germanium detector running for 10 live days at the Soudan Underground Laboratory. A low energy threshold of 170 eVee (electron equivalent) was obtained, which allows us to constrain new WIMP-nucleon spin-independent parameter space for WIMP masses below 6 GeV/c2.
[20]  oai:arXiv.org:1310.8327  [pdf] - 741475
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Comments: Snowmass CF1 Final Summary Report: 47 pages and 28 figures with a 5 page appendix on instrumentation R&D
Submitted: 2013-10-30, last modified: 2013-11-03
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter space by examining a spectrum of WIMP models, (c) establish a community consensus on the type of experimental program required to explore that parameter space, and (d) identify the common infrastructure required to practically meet those goals.
[21]  oai:arXiv.org:1304.4279  [pdf] - 732067
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
Comments: 5 pages, 4 figures, as accepted by PRL
Submitted: 2013-04-15, last modified: 2013-10-11
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10 GeV/c2. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative WIMP+background hypothesis. The highest likelihood occurs for a WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
[22]  oai:arXiv.org:1305.2405  [pdf] - 1530127
Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches
Comments: 5 pages, 4 figures, submitted to journal
Submitted: 2013-05-10, last modified: 2013-10-04
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L., corresponding to $< 0.6$ surface event background in the future 200-kg SuperCDMS SNOLAB experiment.
[23]  oai:arXiv.org:1304.3706  [pdf] - 719385
Silicon detector results from the first five-tower run of CDMS II
Comments: 5 pages, 4 figures; updated to match published version
Submitted: 2013-04-12, last modified: 2013-09-14
We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II's full complement of detectors in 2006-2007; results from this exposure using the Ge detectors have already been presented. We observed no candidate WIMP-scattering events in an exposure of 55.9 kg-days before analysis cuts, with an expected background of ~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10 GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude parameter space for spin-independent WIMP-nucleon elastic scattering that is relevant to recent searches for low-mass WIMPs.
[24]  oai:arXiv.org:1203.1309  [pdf] - 564223
Search for annual modulation in low-energy CDMS-II data
Comments: 5 pages, plus 8 pages supplementary materials
Submitted: 2012-03-06, last modified: 2012-09-18
We report limits on annual modulation of the low-energy event rate from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Such a modulation could be produced by interactions from Weakly Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no evidence for annual modulation in the event rate of veto-anticoincident single-detector interactions consistent with nuclear recoils, and constrain the magnitude of any modulation to <0.06 event [keVnr kg day]^-1 in the 5-11.9 keVnr energy range at the 99% confidence level. These results disfavor an explanation for the reported modulation in the 1.2-3.2 keVee energy range in CoGeNT in terms of nuclear recoils resulting from elastic scattering of WIMPs at >98% confidence. For events consistent with electron recoils, no significant modulation is observed for either single- or multiple-detector interactions in the 3.0-7.4 keVee range.
[25]  oai:arXiv.org:1105.3377  [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS; Collaborations, EDELWEISS; :; Ahmed, Z.; Akerib, D. S.; Armengaud, E.; Arrenberg, S.; Augier, C.; Bailey, C. N.; Balakishiyeva, D.; Baudis, L.; Bauer, D. A.; Benoît, A.; Bergé, L.; Blümer, J.; Brink, P. L.; Broniatowski, A.; Bruch, T.; Brudanin, V.; Bunker, R.; Cabrera, B.; Caldwell, D. O.; Censier, B.; Chapellier, M.; Chardin, G.; Charlieux, F.; Cooley, J.; Coulter, P.; Cox, G. A.; Cushman, P.; Daal, M.; Defay, X.; De Jesus, M.; DeJongh, F.; Di Stefano, P. C. F.; Dolgorouki, Y.; Domange, J.; Dumoulin, L.; Dragowsky, M. R.; Eitel, K.; Fallows, S.; Figueroa-Feliciano, E.; Filippini, J.; Filosofov, D.; Fourches, N.; Fox, J.; Fritts, M.; Gascon, J.; Gerbier, G.; Gironnet, J.; Golwala, S. R.; Gros, M.; Hall, J.; Hennings-Yeomans, R.; Henry, S.; Hertel, S. A.; Hervé, S.; Holmgren, D.; Hsu, L.; Huber, M. E.; Juillard, A.; Kamaev, O.; Kiveni, M.; Kluck, H.; Kos, M.; Kozlov, V.; Kraus, H.; Kudryavtsev, V. A.; Leman, S. W.; Liu, S.; Loaiza, P.; Mahapatra, R.; Mandic, V.; Marnieros, S.; Martinez, C.; McCarthy, K. A.; Mirabolfathi, N.; Moore, D.; Nadeau, P.; Navick, X-F.; Nelson, H.; Nones, C.; Ogburn, R. W.; Olivieri, E.; Pari, P.; Pattavina, L.; Paul, B.; Phipps, A.; Pyle, M.; Qiu, X.; Rau, W.; Reisetter, A.; Ricci, Y.; Robinson, M.; Rozov, S.; Saab, T.; Sadoulet, B.; Sander, J.; Sanglard, V.; Schmidt, B.; Schnee, R. W.; Scorza, S.; Seitz, D. N.; Semikh, S.; Serfass, B.; Sundqvist, K. M.; Tarka, M.; Torrento-Coello, A. S.; Vagneron, L.; Verdier, M. -A.; Walker, R. J.; Wikus, P.; Yakushev, E.; Yellin, S.; Yoo, J.; Young, B. A.; Zhang, J.
Comments: Events, efficiencies, and main limit are available in text format (see README.txt)
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.
[26]  oai:arXiv.org:1012.5078  [pdf] - 371990
Search for inelastic dark matter with the CDMS II experiment
Comments: 10 pages, 10 figures, minor changes to match published version, conclusion unchanged
Submitted: 2010-12-22, last modified: 2011-06-12
Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the inelastic dark matter (iDM) model. Three dark matter candidates were found between 25 keV and 150 keV. The probability to observe three or more background events in this energy range is 11%. Because of the occurrence of these events the constraints on the iDM parameter space are slightly less stringent than those from our previous analysis, which used an energy window of 10-100 keV.
[27]  oai:arXiv.org:1011.2482  [pdf] - 347805
Results from a Low-Energy Analysis of the CDMS II Germanium Data
Comments: 9 pages, 8 figures. Supplemental material included as ancillary files. v3) Added appendix with additional details regarding energy scale and backgrounds
Submitted: 2010-11-10, last modified: 2011-04-21
We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below ~10 GeV/c^2. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.
[28]  oai:arXiv.org:1010.4290  [pdf] - 286319
Low-threshold analysis of CDMS shallow-site data
Comments: 18 pages, 12 figures, 5 tables
Submitted: 2010-10-20, last modified: 2011-01-03
Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four ~224 g germanium and two ~105 g silicon detectors were operated at the Stanford Underground Facility (SUF) between December 2001 and June 2002, yielding 118 live days of raw exposure. Three of the germanium and both silicon detectors were analyzed with a new low-threshold technique, making it possible to lower the germanium and silicon analysis thresholds down to the actual trigger thresholds of ~1 keV and ~2 keV, respectively. Limits on the spin-independent cross section for weakly interacting massive particles (WIMPs) to elastically scatter from nuclei based on these data exclude interesting parameter space for WIMPs with masses below 9 GeV/c^2. Under standard halo assumptions, these data partially exclude parameter space favored by interpretations of the DAMA/LIBRA and CoGeNT experiments' data as WIMP signals, and exclude new parameter space for WIMP masses between 3 GeV/c^2 and 4 GeV/c^2.
[29]  oai:arXiv.org:0912.1601  [pdf] - 902679
Results from the CDMS II Experiment
Comments: 5 pages, 4 figures, to appear in the proceedings of the TAUP09 conference (Rome, July 1st-5th 2009)
Submitted: 2009-12-08
I report recent results and the status of the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory in Minnesota, USA. A blind analysis of data taken by 30 detectors between October 2006 and July 2007 found zero events consistent with WIMPs elastically scattering in our Ge detectors. This resulted in an upper limit on the spin-independent, WIMP-nucleon cross section of 6.6 x 10^-44 cm^2 (4.6 x 10^-44 cm^2 when combined with our previous results) at the 90% C.L. for a WIMP of mass 60 GeV/c^2. In March 2009 data taking with CDMS II stopped in order to install the first of 5 SuperTowers of detectors for the SuperCDMS Soudan project. Analysis of data taken between August 2007 and March 2009 is ongoing.
[30]  oai:arXiv.org:0907.1438  [pdf] - 142195
Analysis of the low-energy electron-recoil spectrum of the CDMS experiment
Comments: 4 pages, 3 figures
Submitted: 2009-07-09
We report on the analysis of the low-energy electron-recoil spectrum from the CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis provides details on the observed counting rate and possible background sources in the energy range of 2 - 8.5 keV. We find no significant excess in the counting rate above background, and compare this observation to the recent DAMA results. In the framework of a conversion of a dark matter particle into electromagnetic energy, our 90% confidence level upper limit of 0.246 events/kg/day at 3.15 keV is lower than the total rate above background observed by DAMA by 8.9$\sigma$. In absence of any specific particle physics model to provide the scaling in cross section between NaI and Ge, we assume a Z^2 scaling. With this assumption the observed rate in DAMA differs from the upper limit in CDMS by 6.8$\sigma$. Under the conservative assumption that the modulation amplitude is 6% of the total rate we obtain upper limits on the modulation amplitude a factor of ~2 less than observed by DAMA, constraining some possible interpretations of this modulation.
[31]  oai:arXiv.org:astro-ph/0607621  [pdf] - 83824
Status and Perspectives of Dark Matter Searches
Comments: 14 pages, 7 figures, to appear in proceedings from "Les Rencontres de Physique de la Vallee d'Aoste", March 5-11 2006, La Thuile (AO), Italy
Submitted: 2006-07-27
In the last year many collaborations searching for the dark matter constituent have published results from their experiments. Here I give a review of direct detection searches reported by the DAMA, KIMS, CDMS-II, EDELWEISS-I, CRESST-II and ZEPLIN-I collaborations. I also outline the future plans of each collaboration as well as the XENON10 collaboration.
[32]  oai:arXiv.org:astro-ph/0503583  [pdf] - 880834
Beyond the CDMS-II Dark Matter Search: SuperCDMS
Comments: Submitted to Texas Symposium on Relativistic Astrophysics held at Stanford, Dec. 2004. Paper has 6 pages, 4 figures
Submitted: 2005-03-27
Presently the CDMS-II collaboration's Weakly Interacting Massive Particle (WIMP) search at the Soudan Underground Laboratory sets the most stringent exclusion limits of any WIMP cold dark matter direct-detection experiment. To extend our reach further, to WIMP-nucleon cross sections in the range $10^{-46} - 10^{-44}$cm$^2$, we propose SuperCDMS, which would take advantage of a very deep site. One promising site is the recently approved SNOLab facility in Canada. In this paper we will present our overall plan, identify primary issues, and set the goals that need to be met prior to embarking upon each phase of SuperCDMS.