Constantikes, Kim T.
Normalized to: Constantikes, K.
1 article(s) in total. 8 co-authors. Median position in authors list is 3,0.
[1]
oai:arXiv.org:1104.1593 [pdf] - 971929
Measuring and Correcting Wind-Induced Pointing Errors of the Green Bank
Telescope Using an Optical Quadrant Detector
Submitted: 2011-04-08
Wind-induced pointing errors are a serious concern for large-aperture
high-frequency radio telescopes. In this paper, we describe the implementation
of an optical quadrant detector instrument that can detect and provide a
correction signal for wind-induced pointing errors on the 100m diameter Green
Bank Telescope (GBT). The instrument was calibrated using a combination of
astronomical measurements and metrology. We find that the main wind-induced
pointing errors on time scales of minutes are caused by the feedarm being blown
along the direction of the wind vector. We also find that wind-induced
structural excitation is virtually non-existent. We have implemented offline
software to apply pointing corrections to the data from imaging instruments
such as the MUSTANG 3.3 mm bolometer array, which can recover ~70% of
sensitivity lost due to wind-induced pointing errors. We have also performed
preliminary tests that show great promise for correcting these pointing errors
in real-time using the telescope's subreflector servo system in combination
with the quadrant detector signal.