sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Columbro, F.

Normalized to: Columbro, F.

15 article(s) in total. 515 co-authors, from 1 to 14 common article(s). Median position in authors list is 14,0.

[1]  oai:arXiv.org:2005.01187  [pdf] - 2089273
Progress report on the Large Scale Polarization Explorer
Comments: 8 pages, 5 figures, Accepted for publication in Journal of Low Temperature Physics
Submitted: 2020-05-03, last modified: 2020-05-05
The Large Scale Polarization Explorer (LSPE) is a cosmology program for the measurement of large scale curl-like features (B-modes) in the polarization of the Cosmic Microwave Background. Its goal is to constrain the background of inflationary gravity waves traveling through the universe at the time of matter-radiation decoupling. The two instruments of LSPE are meant to synergically operate by covering a large portion of the northern microwave sky. LSPE/STRIP is a coherent array of receivers planned to be operated from the Teide Observatory in Tenerife, for the control and characterization of the low-frequency polarized signals of galactic origin; LSPE/SWIPE is a balloon-borne bolometric polarimeter based on 330 large throughput multi-moded detectors, designed to measure the CMB polarization at 150 GHz and to monitor the polarized emission by galactic dust above 200 GHz. The combined performance and the expected level of systematics mitigation will allow LSPE to constrain primordial B-modes down to a tensor/scalar ratio of $10^{-2}$. We here report the status of the STRIP pre-commissioning phase and the progress in the characterization of the key subsystems of the SWIPE payload (namely the cryogenic polarization modulation unit and the multi-moded TES pixels) prior to receiver integration.
[2]  oai:arXiv.org:2002.03589  [pdf] - 2045578
In-flight performance of the LEKIDs of the OLIMPO experiment
Comments:
Submitted: 2020-02-10
We describe the in-flight performance of the horn-coupled Lumped Element Kinetic Inductance Detector arrays of the balloon-borne OLIMPO experiment. These arrays have been designed to match the spectral bands of OLIMPO: 150, 250, 350, and 460 GHz, and they have been operated at 0.3 K and at an altitude of 37.8 km during the stratospheric flight of the OLIMPO payload, in Summer 2018. During the first hours of flight, we tuned the detectors and verified their large dynamics under the radiative background variations due to elevation increase of the telescope and to the insertion of the plug-in room-temperature differential Fourier transform spectrometer into the optical chain. We have found that the detector noise equivalent powers are close to be photon-noise limited and lower than those measured on the ground. Moreover, the data contamination due to primary cosmic rays hitting the arrays is less than 3% for all the pixels of all the arrays, and less than 1% for most of the pixels. These results can be considered the first step of KID technology validation in a representative space environment.
[3]  oai:arXiv.org:2001.10272  [pdf] - 2065386
QUBIC: the Q & U Bolometric Interferometer for Cosmology
Battistelli, E. S.; Ade, P.; Alberro, J. G.; Almela, A.; Amico, G.; Arnaldi, L. H.; Auguste, D.; Aumont, J.; Azzoni, S.; Banfi, S.; Battaglia, P.; Baù, A.; Bèlier, B.; Bennett, D.; Bergè, L.; Bernard, J. -Ph.; Bersanelli, M.; Bigot-Sazy, M. -A.; Bleurvacq, N.; Bonaparte, J.; Bonis, J.; Bottani, A.; Bunn, E.; Burke, D.; Buzi, D.; Buzzelli, A.; Cavaliere, F.; Chanial, P.; Chapron, C.; Charlassier, R.; Columbro, F.; Coppi, G.; Coppolecchia, A.; D'Alessandro, G.; de Bernardis, P.; De Gasperis, G.; De Leo, M.; De Petris, M.; Dheilly, S.; Di Donato, A.; Dumoulin, L.; Etchegoyen, A.; Fasciszewski, A.; Ferreyro, L. P.; Fracchia, D.; Franceschet, C.; Lerena, M. M. Gamboa; Ganga, K.; Garcìa, B.; Redondo, M. E. Garcìa; Gaspard, M.; Gault, A.; Gayer, D.; Gervasi, M.; Giard, M.; Gilles, V.; Giraud-Heraud, Y.; Berisso, M. Gòmez; Gonzàlez, M.; Gradziel, M.; Grandsire, L.; Hamilton, J. -Ch.; Harari, D.; Haynes, V.; Henrot-Versillè, S.; Hoang, D. T.; Incardona, F.; Jules, E.; Kaplan, J.; Korotkov, A.; Kristukat, C.; Lamagna, L.; Loucatos, S.; Louis, T.; Luterstein, R.; Maffei, B.; Marnieros, S.; Marty, W.; Masi, S.; Mattei, A.; May, A.; McCulloch, M.; Medina, M. C.; Mele, L.; Melhuish, S.; Mennella, A.; Montier, L.; Mousset, L.; Mundo, L. M.; Murphy, J. A.; Murphy, J. D.; Nati, F.; Olivieri, E.; Oriol, C.; O'Sullivan, C.; Paiella, A.; Pajot, F.; Passerini, A.; Pastoriza, H.; Pelosi, A.; Perbost, C.; Perciballi, M.; Pezzotta, F.; Piacentini, F.; Piat, M.; Piccirillo, L.; Pisano, G.; Platino, M.; Polenta, G.; Prèle, D.; Puddu, R.; Rambaud, D.; Ringegni, P.; Romero, G. E.; Salatino, M.; Salum, J. M.; Schillaci, A.; Scòccola, C.; Scully, S.; Spinelli, S.; Stankowiak, G.; Stolpovskiy, M.; Suarez, F.; Tartari, A.; Thermeau, J. -P.; Timbie, P.; Tomasi, M.; Torchinsky, S.; Tristram, M.; Tucker, C.; Tucker, G.; Vanneste, S.; Viganò, D.; Vittorio, N.; Voisin, F.; Watson, B.; Wicek, F.; Zannoni, M.; Zullo, A.
Comments: Accepted for publication in the Journal of Low Temperature Physics
Submitted: 2020-01-28
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addresses these requirements using an innovative approach combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with the deep control of systematics characteristic of interferometers. This makes QUBIC unique with respect to others classical imagers experiments devoted to the CMB polarization. In this contribution we report a description of the QUBIC instrument including recent achievements and the demonstration of the bolometric interferometry performed in lab. QUBIC will be deployed at the observation site in Alto Chorrillos, in Argentina at the end of 2019.
[4]  oai:arXiv.org:2001.01724  [pdf] - 2026608
Updated design of the CMB polarization experiment satellite LiteBIRD
Sugai, H.; Ade, P. A. R.; Akiba, Y.; Alonso, D.; Arnold, K.; Aumont, J.; Austermann, J.; Baccigalupi, C.; Banday, A. J.; Banerji, R.; Barreiro, R. B.; Basak, S.; Beall, J.; Beckman, S.; Bersanelli, M.; Borrill, J.; Boulanger, F.; Brown, M. L.; Bucher, M.; Buzzelli, A.; Calabrese, E.; Casas, F. J.; Challinor, A.; Chan, V.; Chinone, Y.; Cliche, J. -F.; Columbro, F.; Cukierman, A.; Curtis, D.; Danto, P.; de Bernardis, P.; de Haan, T.; De Petris, M.; Dickinson, C.; Dobbs, M.; Dotani, T.; Duband, L.; Ducout, A.; Duff, S.; Duivenvoorden, A.; Duval, J. -M.; Ebisawa, K.; Elleflot, T.; Enokida, H.; Eriksen, H. K.; Errard, J.; Essinger-Hileman, T.; Finelli, F.; Flauger, R.; Franceschet, C.; Fuskeland, U.; Ganga, K.; Gao, J. -R.; Génova-Santos, R.; Ghigna, T.; Gomez, A.; Gradziel, M. L.; Grain, J.; Grupp, F.; Gruppuso, A.; Gudmundsson, J. E.; Halverson, N. W.; Hargrave, P.; Hasebe, T.; Hasegawa, M.; Hattori, M.; Hazumi, M.; Henrot-Versille, S.; Herranz, D.; Hill, C.; Hilton, G.; Hirota, Y.; Hivon, E.; Hlozek, R.; Hoang, D. -T.; Hubmayr, J.; Ichiki, K.; Iida, T.; Imada, H.; Ishimura, K.; Ishino, H.; Jaehnig, G. C.; Jones, M.; Kaga, T.; Kashima, S.; Kataoka, Y.; Katayama, N.; Kawasaki, T.; Keskitalo, R.; Kibayashi, A.; Kikuchi, T.; Kimura, K.; Kisner, T.; Kobayashi, Y.; Kogiso, N.; Kogut, A.; Kohri, K.; Komatsu, E.; Komatsu, K.; Konishi, K.; Krachmalnicoff, N.; Kuo, C. L.; Kurinsky, N.; Kushino, A.; Kuwata-Gonokami, M.; Lamagna, L.; Lattanzi, M.; Lee, A. T.; Linder, E.; Maffei, B.; Maino, D.; Maki, M.; Mangilli, A.; Martínez-González, E.; Masi, S.; Mathon, R.; Matsumura, T.; Mennella, A.; Migliaccio, M.; Minami, Y.; Mistuda, K.; Molinari, D.; Montier, L.; Morgante, G.; Mot, B.; Murata, Y.; Murphy, J. A.; Nagai, M.; Nagata, R.; Nakamura, S.; Namikawa, T.; Natoli, P.; Nerva, S.; Nishibori, T.; Nishino, H.; Nomura, Y.; Noviello, F.; O'Sullivan, C.; Ochi, H.; Ogawa, H.; Ogawa, H.; Ohsaki, H.; Ohta, I.; Okada, N.; Okada, N.; Pagano, L.; Paiella, A.; Paoletti, D.; Patanchon, G.; Piacentini, F.; Pisano, G.; Polenta, G.; Poletti, D.; Prouvé, T.; Puglisi, G.; Rambaud, D.; Raum, C.; Realini, S.; Remazeilles, M.; Roudil, G.; Rubiño-Martín, J. A.; Russell, M.; Sakurai, H.; Sakurai, Y.; Sandri, M.; Savini, G.; Scott, D.; Sekimoto, Y.; Sherwin, B. D.; Shinozaki, K.; Shiraishi, M.; Shirron, P.; Signorelli, G.; Smecher, G.; Spizzi, P.; Stever, S. L.; Stompor, R.; Sugiyama, S.; Suzuki, A.; Suzuki, J.; Switzer, E.; Takaku, R.; Takakura, H.; Takakura, S.; Takeda, Y.; Taylor, A.; Taylor, E.; Terao, Y.; Thompson, K. L.; Thorne, B.; Tomasi, M.; Tomida, H.; Trappe, N.; Tristram, M.; Tsuji, M.; Tsujimoto, M.; Tucker, C.; Ullom, J.; Uozumi, S.; Utsunomiya, S.; Van Lanen, J.; Vermeulen, G.; Vielva, P.; Villa, F.; Vissers, M.; Vittorio, N.; Voisin, F.; Walker, I.; Watanabe, N.; Wehus, I.; Weller, J.; Westbrook, B.; Winter, B.; Wollack, E.; Yamamoto, R.; Yamasaki, N. Y.; Yanagisawa, M.; Yoshida, T.; Yumoto, J.; Zannoni, M.; Zonca, A.
Comments: Journal of Low Temperature Physics, in press
Submitted: 2020-01-06
Recent developments of transition-edge sensors (TESs), based on extensive experience in ground-based experiments, have been making the sensor techniques mature enough for their application on future satellite CMB polarization experiments. LiteBIRD is in the most advanced phase among such future satellites, targeting its launch in Japanese Fiscal Year 2027 (2027FY) with JAXA's H3 rocket. It will accommodate more than 4000 TESs in focal planes of reflective low-frequency and refractive medium-and-high-frequency telescopes in order to detect a signature imprinted on the cosmic microwave background (CMB) by the primordial gravitational waves predicted in cosmic inflation. The total wide frequency coverage between 34GHz and 448GHz enables us to extract such weak spiral polarization patterns through the precise subtraction of our Galaxy's foreground emission by using spectral differences among CMB and foreground signals. Telescopes are cooled down to 5Kelvin for suppressing thermal noise and contain polarization modulators with transmissive half-wave plates at individual apertures for separating sky polarization signals from artificial polarization and for mitigating from instrumental 1/f noise. Passive cooling by using V-grooves supports active cooling with mechanical coolers as well as adiabatic demagnetization refrigerators. Sky observations from the second Sun-Earth Lagrangian point, L2, are planned for three years. An international collaboration between Japan, USA, Canada, and Europe is sharing various roles. In May 2019, the Institute of Space and Astronautical Science (ISAS), JAXA selected LiteBIRD as the strategic large mission No. 2.
[5]  oai:arXiv.org:1911.12418  [pdf] - 2011325
QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB
Piat, M.; Bélier, B.; Bergé, L.; Bleurvacq, N.; Chapron, C.; Dheilly, S.; Dumoulin, L.; González, M.; Grandsire, L.; Hamilton, J. -Ch.; Henrot-Versillé, S.; Hoang, D. T.; Marnieros, S.; Marty, W.; Montier, L.; Olivieri, E.; Oriol, C.; Perbost, C.; Prêle, D.; Rambaud, D.; Salatino, M.; Stankowiak, G.; Thermeau, J. -P.; Torchinsky, S.; Voisin, F.; Ade, P.; Alberro, J. G.; Almela, A.; Amico, G.; Arnaldi, L. H.; Auguste, D.; Aumont, J.; Azzoni, S.; Banfi, S.; Battaglia, P.; Battistelli, E. S.; Baù, A.; Bennett, D.; Bernard, J. -Ph.; Bersanelli, M.; Bigot-Sazy, M. -A.; Bonaparte, J.; Bonis, J.; Bottani, A.; Bunn, E.; Burke, D.; Buzi, D.; Buzzelli, A.; Cavaliere, F.; Chanial, P.; Charlassier, R.; Columbro, F.; Coppi, G.; Coppolecchia, A.; D'Alessandro, G.; de Bernardis, P.; De Gasperis, G.; De Leo, M.; De Petris, M.; Di Donato, A.; Etchegoyen, A.; Fasciszewski, A.; Ferreyro, L. P.; Fracchia, D.; Franceschet, C.; Lerena, M. M. Gamboa; Ganga, K.; García, B.; Redondo, M. E. García; Gaspard, M.; Gault, A.; Gayer, D.; Gervasi, M.; Giard, M.; Gilles, V.; Giraud-Heraud, Y.; Berisso, M. Gómez; Gradziel, M.; Harari, D.; Haynes, V.; Incardona, F.; Jules, E.; Kaplan, J.; Korotkov, A.; Kristukat, C.; Lamagna, L.; Loucatos, S.; Louis, T.; Luterstein, R.; Maffei, B.; Masi, S.; Mattei, A.; May, A.; McCulloch, M.; Medina, M. C.; Mele, L.; Melhuish, S.; Mennella, A.; Mousset, L.; Mundo, L. M.; Murphy, J. A.; Murphy, J. D.; Nati, F.; O'Sullivan, C.; Paiella, A.; Pajot, F.; Passerini, A.; Pastoriza, H.; Pelosi, A.; Perciballi, M.; Pezzotta, F.; Piacentini, F.; Piccirillo, L.; Pisano, G.; Platino, M.; Polenta, G.; Puddu, R.; Ringegni, P.; Romero, G. E.; Salum, J. M.; Schillaci, A.; Scóccola, C.; Scully, S.; Spinelli, S.; Stolpovskiy, M.; Suarez, F.; Tartari, A.; Timbie, P.; Tomasi, M.; Tucker, C.; Tucker, G.; Vanneste, S.; Viganò, D.; Vittorio, N.; Watson, B.; Wicek, F.; Zannoni, M.; Zullo, A.
Comments: Conference proceedings submitted to the Journal of Low Temperature Physics for LTD18
Submitted: 2019-11-27, last modified: 2019-12-09
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detectors. QUBIC will be deployed in Argentina, at the Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta province. The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors (TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at 1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K allowing to reach an unprecedented multiplexing (MUX) factor equal to 128. The QUBIC experiment is currently being characterized in the lab with a reduced number of detectors before upgrading to the full instrument. I will present the last results of this characterization phase with a focus on the detectors and readout system.
[6]  oai:arXiv.org:1906.07010  [pdf] - 1920986
Systematic effects induced by Half Wave Plate precession into Cosmic Microwave Background polarization measurements
Comments: 18 pages
Submitted: 2019-06-17
The most accessible method to measure polarization features of the CMB radiation is by means of a Stokes Polarimeter based on the rotation of an Half Wave Plate. The current observational cosmology is starting to be limited by the presence of systematic effects. The Stokes polarimeter with a rotating Half Wave Plate (HWP) has the advantage of mitigating a long list of potential systematics, by modulation of the linearly polarized component of the radiation, but the presence of the rotating HWP can by itself introduce new systematic effects, which must be under control, representing one of the most critical part in the design of a B-Modes experiment. In this paper we present, simulate and analyse the spurious signal arising from the precession of a rotating HWP. We first find an analytical formula for the impact of the systematic effect induced by the HWP precession on the propagating radiation, using the 3D generalization of the Muller formalism. We then perform several numerical simulations, showing the effect induced on the Stokes parameters by this systematic. We also derive and discuss the impact into B-modes measured by a satellite experiment. We find the analytical formula for the Stokes parameters from a Stokes polarimeter where the HWP follows a precessional motion with an angle $\theta_0$. We show the result depending on the HWP inertia tensor, spinning speed and on $\theta_0$. The result of numerical simulations is reported as a simple timeline of the electric fields. Finally, assuming to observe all the sky with a satellite mission, we analyze the effect on B-modes measurements. The effect is not negligible giving the current B-modes experiments sensitivity, therefore it is a systematic which needs to be carefully considered for future experiments.
[7]  oai:arXiv.org:1904.01890  [pdf] - 1861412
Kinetic Inductance Detectors and readout electronics for the OLIMPO experiment
Comments: Proceedings of WOLTE13, September 10-13, 2018 Sorrento, Italy
Submitted: 2019-04-03
Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn-coupled focal planes of the OLIMPO balloon-borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is aimed at measuring the spectrum of the Sunyaev-Zel'dovich effect for a number of galaxy clusters, and will validate LEKIDs technology in a space-like environment. Our detectors are optimized for an intermediate background level, due to the presence of residual atmosphere and room--temperature optical system and they operate at a temperature of 0.3 K. The LEKID planar superconducting circuits are designed to resonate between 100 and 600 MHz, and to match the impedance of the feeding waveguides; the measured quality factors of the resonators are in the $10^{4}-10^{5}$ range, and they have been tuned to obtain the needed dynamic range. The readout electronics is composed of a $cold$ $part$, which includes a low noise amplifier, a dc$-$block, coaxial cables, and power attenuators; and a $room-temperature$ $part$, FPGA$-$based, including up and down-conversion microwave components (IQ modulator, IQ demodulator, amplifiers, bias tees, attenuators). In this contribution, we describe the optimization, fabrication, characterization and validation of the OLIMPO detector system.
[8]  oai:arXiv.org:1810.00598  [pdf] - 1861309
Kinetic Inductance Detectors for the OLIMPO experiment: design and pre-flight characterization
Comments: Published on JCAP
Submitted: 2018-10-01, last modified: 2019-04-03
We designed, fabricated, and characterized four arrays of horn--coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environment. The corrected focal plane is filled with diffraction limited horn-coupled KID arrays, with 19, 37, 23, 41 active pixels respectively at 150, 250, 350, and 460$\:$GHz. Here we report on the full electrical and optical characterization performed on these detector arrays before the flight. In a dark laboratory cryostat, we measured the resonator electrical parameters, such as the quality factors and the electrical responsivities, at a base temperature of 300$\:$mK. The measured average resonator $Q$s are 1.7$\times{10^4}$, 7.0$\times{10^4}$, 1.0$\times{10^4}$, and 1.0$\times{10^4}$ for the 150, 250, 350, and 460$\:$GHz arrays, respectively. The average electrical phase responsivities on resonance are 1.4$\:$rad/pW, 1.5$\:$rad/pW, 2.1$\:$rad/pW, and 2.1$\:$rad/pW; the electrical noise equivalent powers are 45$\:\rm{aW/\sqrt{Hz}}$, 160$\:\rm{aW/\sqrt{Hz}}$, 80$\:\rm{aW/\sqrt{Hz}}$, and 140$\:\rm{aW/\sqrt{Hz}}$, at 12 Hz. In the OLIMPO cryostat, we measured the optical properties, such as the noise equivalent temperatures (NET) and the spectral responses. The measured NET$_{\rm RJ}$s are $200\:\mu\rm{K\sqrt{s}}$, $240\:\mu\rm{K\sqrt{s}}$, $240\:\mu\rm{K\sqrt{s}}$, and $\:340\mu\rm{K\sqrt{s}}$, at 12 Hz; under 78, 88, 92, and 90 mK Rayleigh-Jeans blackbody load changes respectively for the 150, 250, 350, and 460 GHz arrays. The spectral responses were characterized with the OLIMPO differential Fourier transform spectrometer (DFTS) up to THz frequencies, with a resolution of 1.8 GHz.
[9]  oai:arXiv.org:1904.01891  [pdf] - 1861413
The short wavelength instrument for the polarization explorer balloon-borne experiment: Polarization modulation issues
Comments: Proceeding of IWARA 2018
Submitted: 2019-04-03
In this paper we investigate the impact of using a polarization modulator in the Short Wavelenght Instrument for the Polarization Explorer (SWIPE) of the Large Scale Polarization Explorer (LSPE). The experiment is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales during a circumpolar long-duration stratospheric balloon mission, and uses multi-mode bolometers cooled at 0.3 K. The 330 detectors cover 3 bands at 140 GHz, 220 GHz and 240 GHz. Polarimetry is achieved by means of a large rotating half-wave plate (HWP) and a single wire-grid polarizer in front of the arrays. The polarization modulator is the first polarization-active component of the optical chain, reducing significantly the effect of instrumental polarization. A trade-off study comparing stepped vs spinning HWPs drives the choice towards the second. Modulating the CMB polarization signal at 4 times the spin frequency moves it away from $1/f$ noise from the detectors and the residual atmosphere. The HWP is cooled at 1.6 K to reduce the background on the detectors. Furthermore its polarized emission combined with the emission of the polarizer produces spurious signals modulated at $2f$ and $4f$. The $4f$ component is synchronous with the signal of interest and has to characterized to be removed from cosmological data.
[10]  oai:arXiv.org:1902.08993  [pdf] - 1912750
Kinetic Inductance Detectors for the OLIMPO experiment: in--flight operation and performance
Comments:
Submitted: 2019-02-24
We report on the performance of lumped--elements Kinetic Inductance Detector (KID) arrays for mm and sub--mm wavelengths, operated at 0.3K during the stratospheric flight of the OLIMPO payload, at an altitude of 37.8 km. We find that the detectors can be tuned in-flight, and their performance is robust against radiative background changes due to varying telescope elevation. We also find that the noise equivalent power of the detectors in flight is significantly reduced with respect to the one measured in the laboratory, and close to photon-noise limited performance. The effect of primary cosmic rays crossing the detector is found to be consistent with the expected ionization energy loss with phonon-mediated energy transfer from the ionization sites to the resonators. In the OLIMPO detector arrays, at float, cosmic ray events affect less than 4% of the detector samplings for all the pixels of all the arrays, and less than 1% of the samplings for most of the pixels. These results are also representative of what one can expect from primary cosmic rays in a satellite mission with similar KIDs and instrument environment.
[11]  oai:arXiv.org:1812.00785  [pdf] - 1820173
QUBIC: Exploring the primordial Universe with the Q\&U Bolometric Interferometer
Mennella, Aniello; Ade, Peter; Amico, Giorgio; Auguste, Didier; Aumont, Jonathan; Banfi, Stefano; Barbaràn, Gustavo; Battaglia, Paola; Battistelli, Elia; Baù, Alessandro; Bélier, Benoit; Bennett, David G.; Bergé, Laurent; Bernard, Jean Philippe; Bersanelli, Marco; Sazy, Marie Anne Bigot; Bleurvacq, Nathat; Bonaparte, Juan; Bonis, Julien; Bunn, Emory F.; Burke, David; Buzi, Daniele; Buzzelli, Alessandro; Cavaliere, Francesco; Chanial, Pierre; Chapron, Claude; Charlassier, Romain; Columbro, Fabio; Coppi, Gabriele; Coppolecchia, Alessandro; D'Agostino, Rocco; D'Alessandro, Giuseppe; De Bernardis, Paolo; De Gasperis, Giancarlo; De Leo, Michele; De Petris, Marco; Di Donato, Andres; Dumoulin, Louis; Etchegoyen, Alberto; Fasciszewski, Adrián; Franceschet, Cristian; Lerena, Martin Miguel Gamboa; Garcia, Beatriz; Garrido, Xavier; Gaspard, Michel; Gault, Amanda; Gayer, Donnacha; Gervasi, Massimo; Giard, Martin; Héraud, Yannick Giraud; Berisso, Mariano Gómez; González, Manuel; Gradziel, Marcin; Grandsire, Laurent; Guerard, Eric; Hamilton, Jean Christophe; Harari, Diego; Haynes, Vic; Versillé, Sophie Henrot; Hoang, Duc Thuong; Holtzer, Nicolas; Incardona, Federico; Jules, Eric; Kaplan, Jean; Korotkov, Andrei; Kristukat, Christian; Lamagna, Luca; Loucatos, Soutiris; Lowitz, Amy; Lukovic, Vladimir; Thibault, Louis; Luterstein, Raùl Horacio; Maffei, Bruno; Marnieros, Stefanos; Masi, Silvia; Mattei, Angelo; May, Andrew; McCulloch, Mark; Medina, Maria C.; Mele, Lorenzo; Melhuish, Simon J.; Montier, Ludovic; Mousset, Louise; Mundo, Luis Mariano; Murphy, John Anthony; Murphy, James; O'Sullivan, Creidhe; Olivieri, Emiliano; Paiella, Alessandro; Pajot, Francois; Passerini, Andrea; Pastoriza, Hernan; Pelosi, Alessandro; Perbost, Camille; Perciballi, Maurizio; Pezzotta, Federico; Piacentini, Francesco; Piat, Michel; Piccirillo, Lucio; Pisano, Giampaolo; Polenta, Gianluca; Prêle, Damien; Puddu, Roberto; Rambaud, Damien; Ringegni, Pablo; Romero, Gustavo E.; Salatino, Maria; Schillaci, Alessandro; Scóccola, Claudia G.; Scully, Stephen P.; Spinelli, Sebastiano; Stolpovskiy, Michail; Suarez, Federico; Stankowiak, Guillaume; Tartari, Andrea; Thermeau, Jean Pierre; Timbie, Peter; Tomasi, Maurizio; Torchinsky, Steve A.; Tristram, Mathieu; Tucker, Gregory S.; Tucker, Carole E.; Vanneste, Sylvain; Viganò, Daniele; Vittorio, Nicola; Voisin, Fabrice; Watson, Robert; Wicek, Francois; Zannoni, Mario; Zullo, Antonio
Comments: Proceedings of the 2018 ICNFP conference, Crete. Published by Universe arXiv admin note: text overlap with arXiv:1801.03730
Submitted: 2018-11-30, last modified: 2019-01-23
In this paper we describe QUBIC, an experiment that will observe the polarized microwave sky with a novel approach, which combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. QUBIC unique features are the so-called "self-calibration", a technique that allows us to clean the measured data from instrumental effects, and its spectral imaging power, i.e. the ability to separate the signal in various sub-bands within each frequency band. QUBIC will observe the sky in two main frequency bands: 150 GHz and 220 GHz. A technological demonstrator is currently under testing and will be deployed in Argentina during 2019, while the final instrument is expected to be installed during 2020.
[12]  oai:arXiv.org:1811.02296  [pdf] - 1779826
Thermal architecture for the QUBIC cryogenic receiver
May, A. J.; Chapron, C.; Coppi, G.; D'Alessandro, G.; de Bernardis, P.; Masi, S.; Melhuish, S.; Piat, M.; Piccirillo, L.; Schillaci, A.; Thermeau, J. -P.; Ade, P.; Amico, G.; Auguste, D.; Aumont, J.; Banfi, S.; Barbara, G.; Battaglia, P.; Battistelli, E.; Bau, A.; Belier, B.; Bennett, D.; Berge, L.; Bernard, J. -Ph.; Bersanelli, M.; Bigot-Sazy, M. -A.; Bleurvacq, N.; Bonaparte, J.; Bonis, J.; Bordier, G.; Breelle, E.; Bunn, E.; Burke, D.; Buzi, D.; Buzzelli, A.; Cavaliere, F.; Chanial, P.; Charlassier, R.; Columbro, F.; Coppolecchia, A.; Couchot, F.; D'Agostino, R.; De Gasperis, G.; De Leo, M.; De Petris, M.; Di Donato, A.; Dumoulin, L.; Etchegoyen, A.; Fasciszewski, A.; Franceschet, C.; Lerena, M. M. Gamboa; Garcia, B.; Garrido, X.; Gaspard, M.; Gault, A.; Gayer, D.; Gervasi, M.; Giard, M.; Giraud-Heraud, Y.; Berisso, M. Gomez; Gonzalez, M.; Gradziel, M.; Grandsire, L.; Guerrard, E.; Hamilton, J. -Ch.; Harari, D.; Haynes, V.; Henrot-Versille, S.; Hoang, D. T.; Incardona, F.; Jules, E.; Kaplan, J.; Korotkov, A.; Kristukat, C.; Lamagna, L.; Loucatos, S.; Louis, T.; Lowitz, A.; Lukovic, V.; Luterstein, R.; Maffei, B.; Marnieros, S.; Mattei, A.; McCulloch, M. A.; Medina, M. C.; Mele, L.; Mennella, A.; Montier, L.; Mundo, L. M.; Murphy, J. A.; Murphy, J. D.; O'Sullivan, C.; Olivieri, E.; Paiella, A.; Pajot, F.; Passerini, A.; Pastoriza, H.; Pelosi, A.; Perbost, C.; Perdereau, O.; Pezzotta, F.; Piacentini, F.; Pisano, G.; Polenta, G.; Prele, D.; Puddu, R.; Rambaud, D.; Ringegni, P.; Romero, G. E.; Salatino, M.; Scoccola, C. G.; Scully, S.; Spinelli, S.; Stolpovskiy, M.; Suarez, F.; Tartari, A.; Timbie, P.; Torchinsky, S. A.; Tristram, M.; Truongcanh, V.; Tucker, C.; Tucker, G.; Vanneste, S.; Vigano, D.; Vittorio, N.; Voisin, F.; Watson, B.; Wicek, F.; Zannoni, M.; Zullo, A.
Comments:
Submitted: 2018-11-06
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
[13]  oai:arXiv.org:1801.03730  [pdf] - 1616675
QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to look at the polarized Cosmic Microwave Background
Comments: Presented at the EPS Conference on High Energy Physics, Venice (Italy), 5-12 July 2017 Accepted for publication in conference proceedings
Submitted: 2018-01-11
In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called "self-calibration" is a technique deeply rooted in the interferometric nature of the instrument and allows us to clean the measured data from instrumental effects. The first module of QUBIC is a dual band instrument (150 GHz and 220 GHz) that will be deployed in Argentina during the Fall 2018.
[14]  oai:arXiv.org:1706.05963  [pdf] - 1584862
A Large-Diameter Hollow-Shaft Cryogenic Motor Based on a Superconducting Magnetic Bearing for Millimeter-Wave Polarimetry
Comments:
Submitted: 2017-06-19, last modified: 2017-10-05
In this paper we present the design and measured performance of a novel cryogenic motor based on a superconducting magnetic bearing (SMB). The motor is tailored for use in millimeter-wave half-wave plate (HWP) polarimeters, where a HWP is rapidly rotated in front of a polarization analyzer or polarization-sensitive detector. This polarimetry technique is commonly used in cosmic microwave background (CMB) polarization studies. The SMB we use is composed of fourteen yttrium barium copper oxide (YBCO) disks and a contiguous neodymium iron boron (NdFeB) ring magnet. The motor is a hollow-shaft motor because the HWP is ultimately installed in the rotor. The motor presented here has a 100 mm diameter rotor aperture. However, the design can be scaled up to rotor aperture diameters of approximately 500 mm. Our motor system is composed of four primary subsystems: (i) the rotor assembly, which includes the NdFeB ring magnet, (ii) the stator assembly, which includes the YBCO disks, (iii) an incremental encoder, and (iv) the drive electronics. While the YBCO is cooling through its superconducting transition, the rotor is held above the stator by a novel hold and release mechanism (HRM). The encoder subsystem consists of a custom-built encoder disk read out by two fiber optic readout sensors. For the demonstration described in this paper, we ran the motor at 50 K and tested rotation frequencies up to approximately 10 Hz. The feedback system was able to stabilize the the rotation speed to approximately 0.4%, and the measured rotor orientation angle uncertainty is less than 0.15 deg. Lower temperature operation will require additional development activities, which we will discuss.
[15]  oai:arXiv.org:1705.02170  [pdf] - 1935357
Exploring Cosmic Origins with CORE: The Instrument
de Bernardis, P.; Ade, P. A. R.; Baselmans, J. J. A.; Battistelli, E. S.; Benoit, A.; Bersanelli, M.; Bideaud, A.; Calvo, M.; Casas, F. J.; Castellano, G.; Catalano, A.; Charles, I.; Colantoni, I.; Columbro, F.; Coppolecchia, A.; Crook, M.; D'Alessandro, G.; De Petris, M.; Delabrouille, J.; Doyle, S.; Franceschet, C.; Gomez, A.; Goupy, J.; Hanany, S.; Hills, M.; Lamagna, L.; Macias-Perez, J.; Maffei, B.; Martin, S.; Martinez-Gonzalez, E.; Masi, S.; McCarthy, D.; Mennella, A.; Monfardini, A.; Noviello, F.; Paiella, A.; Piacentini, F.; Piat, M.; Pisano, G.; Signorelli, G.; Tan, C. Y.; Tartari, A.; Trappe, N.; Triqueneaux, S.; Tucker, C.; Vermeulen, G.; Young, K.; Zannoni, M.; Achúcarro, A.; Allison, R.; Ashdown, M.; Ballardini, M.; Banday, A. J.; Banerji, R.; Bartlett, J.; Bartolo, N.; Basak, S.; Bonaldi, A.; Bonato, M.; Borrill, J.; Bouchet, F.; Boulanger, F.; Brinckmann, T.; Bucher, M.; Burigana, C.; Buzzelli, A.; Cai, Z. Y.; Carvalho, C. S.; Challinor, A.; Chluba, J.; Clesse, S.; De Gasperis, G.; De Zotti, G.; Di Valentino, E.; Diego, J. M.; Errard, J.; Feeney, S.; Fernandez-Cobos, R.; Finelli, F.; Forastieri, F.; Galli, S.; Génova-Santos, R.; Gerbino, M.; González-Nuevo, J.; Hagstotz, S.; Greenslade, J.; Handley, W.; Hernández-Monteagudo, C.; Hervias-Caimapo, C.; Hivon, E.; Kiiveri, K.; Kisner, T.; Kitching, T.; Kunz, M.; Kurki-Suonio, H.; Lasenby, A.; Lattanzi, M.; Lesgourgues, J.; Lewis, A.; Liguori, M.; Lindholm, V.; Luzzi, G.; Martins, C. J. A. P.; Melchiorri, A.; Melin, J. B.; Molinari, D.; Natoli, P.; Negrello, M.; Notari, A.; Paoletti, D.; Patanchon, G.; Polastri, L.; Polenta, G.; Pollo, A.; Poulin, V.; Quartin, M.; Remazeilles, M.; Roman, M.; Rubiño-Martín, J. A.; Salvati, L.; Tomasi, M.; Tramonte, D.; Trombetti, T.; Väliviita, J.; Van de Weijgaert, R.; van Tent, B.; Vennin, V.; Vielva, P.; Vittorio, N.
Comments: 43 pages
Submitted: 2017-05-05, last modified: 2017-05-22
We describe a space-borne, multi-band, multi-beam polarimeter aiming at a precise and accurate measurement of the polarization of the Cosmic Microwave Background. The instrument is optimized to be compatible with the strict budget requirements of a medium-size space mission within the Cosmic Vision Programme of the European Space Agency. The instrument has no moving parts, and uses arrays of diffraction-limited Kinetic Inductance Detectors to cover the frequency range from 60 GHz to 600 GHz in 19 wide bands, in the focal plane of a 1.2 m aperture telescope cooled at 40 K, allowing for an accurate extraction of the CMB signal from polarized foreground emission. The projected CMB polarization survey sensitivity of this instrument, after foregrounds removal, is 1.7 {\mu}K$\cdot$arcmin. The design is robust enough to allow, if needed, a downscoped version of the instrument covering the 100 GHz to 600 GHz range with a 0.8 m aperture telescope cooled at 85 K, with a projected CMB polarization survey sensitivity of 3.2 {\mu}K$\cdot$arcmin.