sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Colombo, F.

Normalized to: Colombo, F.

4 article(s) in total. 124 co-authors, from 1 to 4 common article(s). Median position in authors list is 31,0.

[1]  oai:arXiv.org:1005.2541  [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
Comments: 15 pages, 18 figures. Accepted for publication in Astronomy and Astrophysics
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.
[2]  oai:arXiv.org:1001.4646  [pdf] - 33161
Dynamic validation of the Planck/LFI thermal model
Comments: Planck LFI technical papers published by JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221
Submitted: 2010-01-26
The Low Frequency Instrument (LFI) is an array of cryogenically cooled radiometers on board the Planck satellite, designed to measure the temperature and polarization anisotropies of the cosmic microwave backgrond (CMB) at 30, 44 and 70 GHz. The thermal requirements of the LFI, and in particular the stringent limits to acceptable thermal fluctuations in the 20 K focal plane, are a critical element to achieve the instrument scientific performance. Thermal tests were carried out as part of the on-ground calibration campaign at various stages of instrument integration. In this paper we describe the results and analysis of the tests on the LFI flight model (FM) performed at Thales Laboratories in Milan (Italy) during 2006, with the purpose of experimentally sampling the thermal transfer functions and consequently validating the numerical thermal model describing the dynamic response of the LFI focal plane. This model has been used extensively to assess the ability of LFI to achieve its scientific goals: its validation is therefore extremely important in the context of the Planck mission. Our analysis shows that the measured thermal properties of the instrument show a thermal damping level better than predicted, therefore further reducing the expected systematic effect induced in the LFI maps. We then propose an explanation of the increased damping in terms of non-ideal thermal contacts.
[3]  oai:arXiv.org:1001.4562  [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
Comments: Accepted for publications in Astronomy and Astrophysics. Astronomy & Astrophysics, 2010 (acceptance date: 12 Jan 2010)
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
[4]  oai:arXiv.org:1001.3321  [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency Instrument
Bersanelli, M.; Mandolesi, N.; Butler, R. C.; Mennella, A.; Villa, F.; Aja, B.; Artal, E.; Artina, E.; Baccigalupi, C.; Balasini, M.; Baldan, G.; Banday, A.; Bastia, P.; Battaglia, P.; Bernardino, T.; Blackhurst, E.; Boschini, L.; Burigana, C.; Cafagna, G.; Cappellini, B.; Cavaliere, F.; Colombo, F.; Crone, G.; Cuttaia, F.; D'Arcangelo, O.; Danese, L.; Davies, R. D.; Davis, R. J.; De Angelis, L.; De Gasperis, G. C.; De La Fuente, L.; De Rosa, A.; De Zotti, G.; Falvella, M. C.; Ferrari, F.; Ferretti, R.; Figini, L.; Fogliani, S.; Franceschet, C.; Franceschi, E.; Gaier, T.; Garavaglia, S.; Gomez, F.; Gorski, K.; Gregorio, A.; Guzzi, P.; Herreros, J. M.; Hildebrandt, S. R.; Hoyland, R.; Hughes, N.; Janssen, M.; Jukkala, P.; Kettle, D.; Kilpia, V. H.; Laaninen, M.; Lapolla, P. M.; Lawrence, C. R.; Leahy, J. P.; Leonardi, R.; Leutenegger, P.; Levin, S.; Lilje, P. B.; Lowe, S. R.; Lubin, D. Lawson P. M.; Maino, D.; Malaspina, M.; Maris, M.; Marti-Canales, J.; Martinez-Gonzalez, E.; Mediavilla, A.; Meinhold, P.; Miccolis, M.; Morgante, G.; Natoli, P.; Nesti, R.; Pagan, L.; Paine, C.; Partridge, B.; Pascual, J. P.; Pasian, F.; Pearson, D.; Pecora, M.; Perrotta, F.; Platania, P.; Pospieszalski, M.; Poutanen, T.; Prina, M.; Rebolo, R.; Roddis, N.; Rubino-Martin, J. A.; Salmon, n M. J.; Sandri, M.; Seiffert, M.; Silvestri, R.; Simonetto, A.; Sjoman, P.; Smoot, G. F.; Sozzi, C.; Stringhetti, L.; Taddei, E.; Tauber, J.; Terenzi, L.; Tomasi, M.; Tuovinen, J.; Valenziano, L.; Varis, J.; Vittorio, N.; Wade, L. A.; Wilkinson, A.; Winder, F.; Zacchei, A.; Zonca, A.
Comments: 23 pages, 31 figures, accepted by Astronomy and Astrophysics, Planck LFI technical papers published by JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.