We report on the design and performance of Microwave Kinetic Inductance
Detectors (MKIDs) sensitive to single photons in the optical to near-infrared
range using hafnium as the sensor material. Our test device had a
superconducting transition temperature of 395 mK and a room temperature normal
state resistivity of 97 $\mu \Omega$ cm with an RRR = 1.6. Resonators on the
device displayed internal quality factors of around 200,000. Similar to the
analysis of MKIDs made from other highly resistive superconductors, we find
that modeling the temperature response of the detector requires an extra
broadening parameter in the superconducting density of states. Finally, we show
that this material and design is compatible with a full-array fabrication
process which resulted in pixels with decay times of about 40 $\mu$s and
resolving powers of ~9 at 800 nm.
[2]
oai:arXiv.org:1808.05219 [pdf] - 1734290
Light Dark Matter eXperiment (LDMX)
Åkesson, Torsten;
Berlin, Asher;
Blinov, Nikita;
Colegrove, Owen;
Collura, Giulia;
Dutta, Valentina;
Echenard, Bertrand;
Hiltbrand, Joshua;
Hitlin, David G.;
Incandela, Joseph;
Jaros, John;
Johnson, Robert;
Krnjaic, Gordan;
Mans, Jeremiah;
Maruyama, Takashi;
McCormick, Jeremy;
Moreno, Omar;
Nelson, Timothy;
Niendorf, Gavin;
Petersen, Reese;
Pöttgen, Ruth;
Schuster, Philip;
Toro, Natalia;
Tran, Nhan;
Whitbeck, Andrew
Submitted: 2018-08-15
We present an initial design study for LDMX, the Light Dark Matter
Experiment, a small-scale accelerator experiment having broad sensitivity to
both direct dark matter and mediator particle production in the sub-GeV mass
region. LDMX employs missing momentum and energy techniques in multi-GeV
electro-nuclear fixed-target collisions to explore couplings to electrons in
uncharted regions that extend down to and below levels that are motivated by
direct thermal freeze-out mechanisms. LDMX would also be sensitive to a wide
range of visibly and invisibly decaying dark sector particles, thereby
addressing many of the science drivers highlighted in the 2017 US Cosmic
Visions New Ideas in Dark Matter Community Report. LDMX would achieve the
required sensitivity by leveraging existing and developing detector
technologies from the CMS, HPS and Mu2e experiments. In this paper, we present
our initial design concept, detailed GEANT-based studies of detector
performance, signal and background processes, and a preliminary analysis
approach. We demonstrate how a first phase of LDMX could expand sensitivity to
a variety of light dark matter, mediator, and millicharge particles by several
orders of magnitude in coupling over the broad sub-GeV mass range.
[3]
oai:arXiv.org:1803.10420 [pdf] - 1666883
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field
Spectrograph for High-Contrast Astronomy
Meeker, Seth R.;
Mazin, Benjamin A.;
Walter, Alex B.;
Strader, Paschal;
Fruitwala, Neelay;
Bockstiegel, Clint;
Szypryt, Paul;
Ulbricht, Gerhard;
Coiffard, Gregoire;
Bumble, Bruce;
Cancelo, Gustavo;
Zmuda, Ted;
Treptow, Ken;
Wilcer, Neal;
Collura, Giulia;
Dodkins, Rupert;
Lipartito, Isabel;
Zobrist, Nicholas;
Bottom, Michael;
Shelton, J. Chris;
Mawet, Dimitri;
van Eyken, Julian C.;
Vasisht, Gautam;
Serabyn, Eugene
Submitted: 2018-03-28, last modified: 2018-04-16
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving
Superconducting Spectrophotometer), the first of several planned integral field
spectrographs to use optical/near-infrared Microwave Kinetic Inductance
Detectors (MKIDs) for high-contrast imaging. The photon counting and
simultaneous low-resolution spectroscopy provided by MKIDs will enable
real-time speckle control techniques and post-processing speckle suppression at
framerates capable of resolving the atmospheric speckles that currently limit
high-contrast imaging from the ground. DARKNESS is now operational behind the
PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at
Palomar Observatory. Here we describe the motivation, design, and
characterization of the instrument, early on-sky results, and future prospects.
[4]
oai:arXiv.org:1710.07318 [pdf] - 1590047
Large-format platinum silicide microwave kinetic inductance detectors
for optical to near-IR astronomy
Szypryt, P.;
Meeker, S. R.;
Coiffard, G.;
Fruitwala, N.;
Bumble, B.;
Ulbricht, G.;
Walter, A. B.;
Daal, M.;
Bockstiegel, C.;
Collura, G.;
Zobrist, N.;
Lipartito, I.;
Mazin, B. A.
Submitted: 2017-10-19
We have fabricated and characterized 10,000 and 20,440 pixel Microwave
Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR
Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID
Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive
optics systems with the goal of directly imaging exoplanets in a 800-1400 nm
band. Previous large optical and near-IR MKID arrays were fabricated using
substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays,
however, suffered from severe non-uniformities in the TiN critical temperature,
causing resonances to shift away from their designed values and lowering usable
detector yield. We have begun fabricating DARKNESS and MEC arrays using
platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays
have much higher uniformity than the TiN arrays, resulting in higher pixel
yields, they have demonstrated better spectral resolution than TiN MKIDs of
similar design. PtSi MKIDs also do not display the hot pixel effects seen when
illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1
um.