sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Collar, J. I.

Normalized to: Collar, J.

73 article(s) in total. 750 co-authors, from 1 to 12 common article(s). Median position in authors list is 2,0.

[1]  oai:arXiv.org:1907.12509  [pdf] - 2100293
Velocity independent constraints on spin-dependent DM-nucleon interactions from IceCube and PICO
IceCube Collaboration; Aartsen, M. G.; Ackermann, M.; Adams, J.; Aguilar, J. A.; Ahlers, M.; Ahrens, M.; Alispach, C.; Andeen, K.; Anderson, T.; Ansseau, I.; Anton, G.; Argüelles, C.; Auffenberg, J.; Axani, S.; Backes, P.; Bagherpour, H.; Bai, X.; V., A. Balagopal; Barbano, A.; Barwick, S. W.; Bastian, B.; Baum, V.; Baur, S.; Bay, R.; Beatty, J. J.; Becker, K. -H.; Tjus, J. Becker; BenZvi, S.; Berley, D.; Bernardini, E.; Besson, D. Z.; Binder, G.; Bindig, D.; Blaufuss, E.; Blot, S.; Bohm, C.; Börner, M.; Böser, S.; Botner, O.; Böttcher, J.; Bourbeau, E.; Bourbeau, J.; Bradascio, F.; Braun, J.; Bron, S.; Brostean-Kaiser, J.; Burgman, A.; Buscher, J.; Busse, R. S.; Carver, T.; Chen, C.; Cheung, E.; Chirkin, D.; Choi, S.; Classen, L.; Coleman, A.; Collin, G. H.; Conrad, J. M.; Coppin, P.; Correa, P.; Cowen, D. F.; Cross, R.; Dave, P.; De Clercq, C.; DeLaunay, J. J.; Dembinski, H.; Deoskar, K.; De Ridder, S.; Desiati, P.; de Vries, K. D.; de Wasseige, G.; de With, M.; DeYoung, T.; Diaz, A.; Díaz-Vélez, J. C.; Dujmovic, H.; Dunkman, M.; Dvorak, E.; Eberhardt, B.; Ehrhardt, T.; Eller, P.; Engel, R.; Evenson, P. A.; Fahey, S.; Fazely, A. R.; Felde, J.; Filimonov, K.; Finley, C.; Franckowiak, A.; Friedman, E.; Fritz, A.; Gaisser, T. K.; Gallagher, J.; Ganster, E.; Garrappa, S.; Gerhardt, L.; Ghorbani, K.; Glauch, T.; Glüsenkamp, T.; Goldschmidt, A.; Gonzalez, J. G.; Grant, D.; Griffith, Z.; Griswold, S.; Günder, M.; Gündüz, M.; Haack, C.; Hallgren, A.; Halve, L.; Halzen, F.; Hanson, K.; Haungs, A.; Hebecker, D.; Heereman, D.; Heix, P.; Helbing, K.; Hellauer, R.; Henningsen, F.; Hickford, S.; Hignight, J.; Hill, G. C.; Hoffman, K. D.; Hoffmann, R.; Hoinka, T.; Hokanson-Fasig, B.; Hoshina, K.; Huang, F.; Huber, M.; Huber, T.; Hultqvist, K.; Hünnefeld, M.; Hussain, R.; In, S.; Iovine, N.; Ishihara, A.; Japaridze, G. S.; Jeong, M.; Jero, K.; Jones, B. J. P.; Jonske, F.; Joppe, R.; Kang, D.; Kang, W.; Kappes, A.; Kappesser, D.; Karg, T.; Karl, M.; Karle, A.; Katz, U.; Kauer, M.; Kelley, J. L.; Kheirandish, A.; Kim, J.; Kintscher, T.; Kiryluk, J.; Kittler, T.; Klein, S. R.; Koirala, R.; Kolanoski, H.; Köpke, L.; Kopper, C.; Kopper, S.; Koskinen, D. J.; Kowalski, M.; Krings, K.; Krückl, G.; Kulacz, N.; Kurahashi, N.; Kyriacou, A.; Labare, M.; Lanfranchi, J. L.; Larson, M. J.; Lauber, F.; Lazar, J. P.; Leonard, K.; Leszczyńska, A.; Leuermann, M.; Liu, Q. R.; Lohfink, E.; Mariscal, C. J. Lozano; Lu, L.; Lucarelli, F.; Lünemann, J.; Luszczak, W.; Lyu, Y.; Ma, W. Y.; Madsen, J.; Maggi, G.; Mahn, K. B. M.; Makino, Y.; Mallik, P.; Mallot, K.; Mancina, S.; Mariş, I. C.; Maruyama, R.; Mase, K.; Maunu, R.; McNally, F.; Meagher, K.; Medici, M.; Medina, A.; Meier, M.; Meighen-Berger, S.; Menne, T.; Merino, G.; Meures, T.; Micallef, J.; Mockler, D.; Momenté, G.; Montaruli, T.; Moore, R. W.; Morse, R.; Moulai, M.; Muth, P.; Nagai, R.; Naumann, U.; Neer, G.; Niederhausen, H.; Nowicki, S. C.; Nygren, D. R.; Pollmann, A. Obertacke; Oehler, M.; Olivas, A.; O'Murchadha, A.; O'Sullivan, E.; Palczewski, T.; Pandya, H.; Pankova, D. V.; Park, N.; Peiffer, P.; Heros, C. Pérez de los; Philippen, S.; Pieloth, D.; Pinat, E.; Pizzuto, A.; Plum, M.; Porcelli, A.; Price, P. B.; Przybylski, G. T.; Raab, C.; Raissi, A.; Rameez, M.; Rauch, L.; Rawlins, K.; Rea, I. C.; Reimann, R.; Relethford, B.; Renschler, M.; Renzi, G.; Resconi, E.; Rhode, W.; Richman, M.; Robertson, S.; Rongen, M.; Rott, C.; Ruhe, T.; Ryckbosch, D.; Rysewyk, D.; Safa, I.; Herrera, S. E. Sanchez; Sandrock, A.; Sandroos, J.; Santander, M.; Sarkar, S.; Sarkar, S.; Satalecka, K.; Schaufel, M.; Schieler, H.; Schlunder, P.; Schmidt, T.; Schneider, A.; Schneider, J.; Schröder, F. G.; Schumacher, L.; Sclafani, S.; Seckel, D.; Seunarine, S.; Shefali, S.; Silva, M.; Snihur, R.; Soedingrekso, J.; Soldin, D.; Song, M.; Spiczak, G. M.; Spiering, C.; Stachurska, J.; Stamatikos, M.; Stanev, T.; Stein, R.; Steinmüller, P.; Stettner, J.; Steuer, A.; Stezelberger, T.; Stokstad, R. G.; Stößl, A.; Strotjohann, N. L.; Stürwald, T.; Stuttard, T.; Sullivan, G. W.; Taboada, I.; Tenholt, F.; Ter-Antonyan, S.; Terliuk, A.; Tilav, S.; Tomankova, L.; Tönnis, C.; Toscano, S.; Tosi, D.; Trettin, A.; Tselengidou, M.; Tung, C. F.; Turcati, A.; Turcotte, R.; Turley, C. F.; Ty, B.; Unger, E.; Elorrieta, M. A. Unland; Usner, M.; Vandenbroucke, J.; Van Driessche, W.; van Eijk, D.; van Eijndhoven, N.; Vanheule, S.; van Santen, J.; Vraeghe, M.; Walck, C.; Wallace, A.; Wallraff, M.; Wandkowsky, N.; Watson, T. B.; Weaver, C.; Weindl, A.; Weiss, M. J.; Weldert, J.; Wendt, C.; Werthebach, J.; Whelan, B. J.; Whitehorn, N.; Wiebe, K.; Wiebusch, C. H.; Wille, L.; Williams, D. R.; Wills, L.; Wolf, M.; Wood, J.; Wood, T. R.; Woschnagg, K.; Wrede, G.; Xu, D. L.; Xu, X. W.; Xu, Y.; Yanez, J. P.; Yodh, G.; Yoshida, S.; Yuan, T.; Collaboration, M. Zöcklein. PICO; :; Amole, C.; Ardid, M.; Arnquist, I. J.; Asner, D. M.; Baxter, D.; Behnke, E.; Bressler, M.; Broerman, B.; Cao, G.; Chen, C. J.; Chowdhury, U.; Clark, K.; Collar, J. I.; Cooper, P. S.; Crisler, M.; Crowder, G.; Cruz-Venegas, N. A.; Dahl, C. E.; Das, M.; Fallows, S.; Farine, J.; Felis, I.; Filgas, R.; Girard, F.; Giroux, G.; Hall, J.; Hardy, C.; Harris, O.; Hoppe, E. W.; Jin, M.; Klopfenstein, L.; Krauss, C. B.; Laurin, M.; Lawson, I.; Leblanc, A.; Levine, I.; Lippincott, W. H.; Mamedov, F.; Maurya, D.; Mitra, P.; Moore, C.; Nania, T.; Neilson, R.; Noble, A. J.; Oedekerk, P.; Ortega, A.; Piro, M. -C.; Plante, A.; Podviyanuk, R.; Priya, S.; Robinson, A. E.; Sahoo, S.; Scallon, O.; Seth, S.; Sonnenschein, A.; Starinski, N.; Štekl, I.; Sullivan, T.; Tardif, F.; Vázquez-Jáuregui, E.; Walkowski, N.; Wichoski, U.; Yan, Y.; Zacek, V.; Zhang, J.
Comments: 9 pages, 3 figures, 1 table. To appear in Eur.Phys.J. C
Submitted: 2019-07-29, last modified: 2020-05-25
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity distribution for dark matter (DM) particles in the Galaxy, the most stringent current constraints on their spin-dependent scattering cross-section with nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$ superheated bubble chamber experiments. The former is sensitive to high energy neutrinos from the self-annihilation of DM particles captured in the Sun, while the latter looks for nuclear recoil events from DM scattering off nucleons. Although slower DM particles are more likely to be captured by the Sun, the faster ones are more likely to be detected by PICO. Recent N-body simulations suggest significant deviations from the SHM for the smooth halo component of the DM, while observations hint at a dominant fraction of the local DM being in substructures. We use the method of Ferrer et al. (2015) to exploit the complementarity between the two approaches and derive conservative constraints on DM-nucleon scattering. Our results constrain $\sigma_{\mathrm{SD}} \lesssim 3 \times 10^{-39} \mathrm{cm}^2$ (6 $ \times 10^{-38} \mathrm{cm}^2$) at $\gtrsim 90\%$ C.L. for a DM particle of mass 1~TeV annihilating into $\tau^+ \tau^-$ ($b\bar{b}$) with a local density of $\rho_{\mathrm{DM}} = 0.3~\mathrm{ GeV/cm}^3$. The constraints scale inversely with $\rho_{\mathrm{DM}}$ and are independent of the DM velocity distribution.
[2]  oai:arXiv.org:1905.12522  [pdf] - 1995410
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers
Comments: 18 pages, 12 figures
Submitted: 2019-05-29, last modified: 2019-11-06
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by a hot-spike as previously supposed. Using this semi-empirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c$^{-2}$.
[3]  oai:arXiv.org:1910.07450  [pdf] - 1981331
Proceedings of The Magnificent CE$\nu$NS Workshop 2018
Comments: The Magnificent CEvNS Workshop (2018), Nov 2-3, 2018; Chicago, IL, USA; 44 contributions
Submitted: 2019-10-16
The Magnificent CE$\nu$NS Workshop (2018) was held November 2 & 3 of 2018 on the University of Chicago campus and brought together theorists, phenomenologists, and experimentalists working in numerous areas but sharing a common interest in the process of coherent elastic neutrino-nucleus scattering (CE$\nu$NS). This is a collection of abstract-like summaries of the talks given at the meeting, including links to the slides presented. This document and the slides from the meeting provide an overview of the field and a snapshot of the robust CE$\nu$NS-related efforts both planned and underway.
[4]  oai:arXiv.org:1902.04031  [pdf] - 1916812
Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber
Comments: 9 pages, 8 figures
Submitted: 2019-02-11
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$ cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.
[5]  oai:arXiv.org:1805.02646  [pdf] - 1712950
Search for a Non-Relativistic Component in the Spectrum of Cosmic Rays at Earth
Comments: 14 pages, 13 figures. V2: small cosmetic change to Fig. 11
Submitted: 2018-05-07, last modified: 2018-05-09
Dark matter particles gravitationally bound to our galaxy should exhibit a characteristic speed distribution limited by their escape velocity at the position of the Earth ($v_{esc}\simeq$ 550 km/s). An ongoing search for anomalous cosmic rays at Earth, kinematically similar to cold dark matter, is described. The technique can discriminate between these and known slow-moving particles such as neutrons, would be sensitive to telltale signatures from presently unexplored candidates, and offers the possibility of identifying the mediating type of interaction (nuclear vs. electron recoils). Studies of background identification and abatement in a shallow underground site are presented. The expected reach of the method is discussed, and illustrated by obtaining the first limits for dark matter particles lighter than 100 MeV/c$^{2}$ interacting via nuclear recoils.
[6]  oai:arXiv.org:1804.06457  [pdf] - 1762928
Liquid Scintillator Response to Proton Recoils in the 10-100 keV Range
Comments: 5 pages, 6 figures. V2: Fig. 1 and references updated
Submitted: 2018-04-17, last modified: 2018-05-07
We study the response of EJ-301 liquid scintillator to monochromatic 244.6 $\pm$ 8.4 keV neutrons, targeting the 10-100 keV proton recoil energy interval. Limited experimental information exists for proton light yield in this range, for this or any other organic scintillator. Our results confirm the adequacy of a modified Birks' model, common to all organic scintillator formulations, predicting a marked increase in quenching factor as proton energy approaches the few keV regime. The relevance of this behavior within the context of searches for low-mass particle dark matter is mentioned.
[7]  oai:arXiv.org:1702.07666  [pdf] - 1581621
Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber
Comments: 6 pages, 6 figures
Submitted: 2017-02-24, last modified: 2017-08-02
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than 1 event per month. A blind analysis of an efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 3.4 $\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one order of magnitude improvement from previous PICO results.
[8]  oai:arXiv.org:1608.00957  [pdf] - 1511854
Measurement of the ionization produced by sub-keV silicon nuclear recoils in a CCD dark matter detector
Comments: 7 pages, 7 figures
Submitted: 2016-08-02, last modified: 2016-11-09
We report a measurement of the ionization efficiency of silicon nuclei recoiling with sub-keV kinetic energy in the bulk silicon of a charge-coupled device (CCD). Nuclear recoils are produced by low-energy neutrons ($<$24 keV) from a $^{124}$Sb-$^{9}$Be photoneutron source, and their ionization signal is measured down to 60 eV electron equivalent. This energy range, previously unexplored, is relevant for the detection of low-mass dark matter particles. The measured efficiency is found to deviate from the extrapolation to low energies of the Lindhard model. This measurement also demonstrates the sensitivity to nuclear recoils of CCDs employed by DAMIC, a dark matter direct detection experiment located in the SNOLAB underground laboratory.
[9]  oai:arXiv.org:1608.03588  [pdf] - 1531249
Measurement of the low-energy quenching factor in germanium using an $^{88}$Y/Be photoneutron source
Comments: 7 pages, 6 figures
Submitted: 2016-08-11
We employ an $^{88}$Y/Be photoneutron source to derive the quenching factor for neutron-induced nuclear recoils in germanium, probing recoil energies from a few hundred eV$_{nr}$ to 8.5keV$_{nr}$. A comprehensive Monte Carlo simulation of our setup is compared to experimental data employing a Lindhard model with a free electronic energy loss $k$ and an adiabatic correction for sub-keV$_{nr}$ nuclear recoils. The best fit $k=0.179\pm 0.001$ obtained using a Monte Carlo Markov Chain (MCMC) ensemble sampler is in good agreement with previous measurements, confirming the adequacy of the Lindhard model to describe the stopping of few-keV ions in germanium crystals at a temperature of $\sim$77 K. This value of $k$ corresponds to a quenching factor of 13.7 % to 25.3 % for nuclear recoil energies between 0.3 keV$_{nr}$ and 8.5 keV$_{nr}$, respectively.
[10]  oai:arXiv.org:1601.03729  [pdf] - 1382109
Improved dark matter search results from PICO-2L Run 2
Comments:
Submitted: 2016-01-14, last modified: 2016-03-25
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nuclear-recoil event was observed in the data, consistent both with the predicted background rate from neutrons and with the observed rate of unambiguous multiple-bubble neutron scattering events. The chamber exhibits the same excellent electron-recoil and alpha decay rejection as was previously reported. These data provide the most stringent direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.
[11]  oai:arXiv.org:1503.04561  [pdf] - 1376478
Search for chameleons with CAST
Comments: 8 pages, 12 figures
Submitted: 2015-03-16, last modified: 2016-03-18
In this work we present a search for (solar) chameleons with the CERN Axion Solar Telescope (CAST). This novel experimental technique, in the field of dark energy research, exploits both the chameleon coupling to matter ($\beta_{\rm m}$) and to photons ($\beta_{\gamma}$) via the Primakoff effect. By reducing the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV CAST became sensitive to the converted solar chameleon spectrum which peaks around 600$\,$eV. Even though we have not observed any excess above background, we can provide a 95% C.L. limit for the coupling strength of chameleons to photons of $\beta_{\gamma}\!\lesssim\!10^{11}$ for $1<\beta_{\rm m}<10^6$.
[12]  oai:arXiv.org:1510.07754  [pdf] - 1382070
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Comments: v3 to reflect published version
Submitted: 2015-10-26, last modified: 2016-03-03
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. These behaviors allow for analysis cuts to remove all background events while retaining $48.2\%$ of the exposure. Stringent limits on weakly interacting massive particles interacting via spin-dependent proton and spin-independent processes are set, and most interpretations of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei are ruled out.
[13]  oai:arXiv.org:1503.00008  [pdf] - 1238863
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Comments: 6 pages, 6 figures, v2 to match published version
Submitted: 2015-02-27, last modified: 2015-06-29
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation of a dependence of acoustic signal on alpha energy. Twelve single nuclear recoil event candidates were observed during the run. The candidate events exhibit timing characteristics that are not consistent with the hypothesis of a uniform time distribution, and no evidence for a dark matter signal is claimed. These data provide the most sensitive direct detection constraints on WIMP-proton spin-dependent scattering to date, with significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon scattering.
[14]  oai:arXiv.org:1307.1985  [pdf] - 867037
CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap
Comments: 5 pages, 2 figures. Last version uploaded
Submitted: 2013-07-08, last modified: 2014-09-15
The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on the pressure setting. Future direct solar axion searches will focus on increasing the sensitivity to smaller values of g_a, for example by the currently discussed next generation helioscope IAXO.
[15]  oai:arXiv.org:1409.3185  [pdf] - 903705
Comment on "Fitting the annual modulation in DAMA with neutrons from muons and neutrinos''
Comments: Comment submitted to PRL
Submitted: 2014-09-10
We estimate rates of solar neutrino-induced neutrons in a DAMA/LIBRA-like detector setup, and find that the needed contribution to explain the annual modulation would require neutrino-induced neutron cross sections several orders of magnitude larger than current calculations indicate. Although these cross sections have never been measured, it is likely that the solar-neutrino effect on DAMA/LIBRA is negligible.
[16]  oai:arXiv.org:1407.7524  [pdf] - 903589
Coherent neutrino-nucleus scattering detection with a CsI[Na] scintillator at the SNS spallation source
Comments: v2: minor corrections
Submitted: 2014-07-28, last modified: 2014-08-20
We study the possibility of using CsI[Na] scintillators as an advantageous target for the detection of coherent elastic neutrino-nucleus scattering (CENNS), using the neutrino emissions from the SNS spallation source at Oak Ridge National Laboratory. The response of this material to low-energy nuclear recoils like those expected from this process is characterized. Backgrounds are studied using a 2 kg low-background prototype crystal in a dedicated radiation shield. The conclusion is that a planned 14 kg detector should measure approximately 550 CENNS events per year above a demonstrated $\sim7$ keVnr low-energy threshold, with a signal-to-background ratio sufficient for a first measurement of the CENNS cross-section. The cross-section for the $^{208}$Pb($\nu_{e},e^{-}$)$^{208}$Bi reaction, of interest for future supernova neutrino detection, can be simultaneously obtained.
[17]  oai:arXiv.org:1407.2581  [pdf] - 849951
Comments on "A Dark Matter Search with MALBEK"
Comments: V2: missing text in a phrase referring to recent CDEX results has been incorporated. Other minor wording changes
Submitted: 2014-07-09
CoGeNT and MALBEK use p-type point contact germanium detectors to search for low-mass dark matter particles. Both detectors enjoy identical intrinsic noise characteristics. However, MALBEK's data acquisition electronics severely degrade the ability to separate signals originating in the bulk of the germanium crystal from surface backgrounds, through a measurement of the preamplifier pulse rise-time in the sub-keVee energy range of interest. The physical meaning of the parameter W$_{par}$ developed by the MAJORANA collaboration to compensate for this limitation is clarified here. It is shown that this parameter does not correlate to rise-time at low energy, and is presently unable to distinguish between surface and bulk events below $\sim$1 keVee. This leads to a sizable overstatement of MALBEK's sensitivity to low-mass dark matter particles, when employing aggressive W$_{par}$ cuts.
[18]  oai:arXiv.org:1304.6001  [pdf] - 778562
Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber
Comments: 5 pages, 3 figures
Submitted: 2013-04-22, last modified: 2014-01-31
We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel telescope and the reconstructed scattering angle provides a measure of the nuclear recoil kinetic energy. The bubble chamber was operated with a nominal threshold of (13.6+-0.6) keV. Interpretation of the results depends on the response to fluorine and carbon recoils, but in general we find agreement with the predictions of the classical bubble nucleation theory. This measurement confirms the applicability of CF3I as a target for spin-independent dark matter interactions and represents a novel technique for calibration of superheated fluid detectors.
[19]  oai:arXiv.org:1401.3295  [pdf] - 770398
Search for An Annual Modulation in Three Years of CoGeNT Dark Matter Detector Data
Comments: Three datasets and note on usage included as ancillary files
Submitted: 2014-01-14
Weakly Interacting Massive Particles (WIMPs) are well-established dark matter candidates. WIMP interactions with sensitive detectors are expected to display a characteristic annual modulation in rate. We release a dataset spanning 3.4 years of operation from a low-background germanium detector, designed to search for this signature. A previously reported modulation persists, concentrated in a region of the energy spectrum populated by an exponential excess of unknown origin. Its phase and period agree with phenomenological expectations, but its amplitude is a factor $\sim$4-7 larger than predicted for a standard WIMP galactic halo. We consider the possibility of a non-Maxwellian local halo velocity distribution as a plausible explanation, able to help reconcile recently reported WIMP search anomalies.
[20]  oai:arXiv.org:1208.5737  [pdf] - 690015
CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors
Comments: 20 pages, 31 figures. Several figures have been added, including an updated allowed region (both 90% and 99% confidence level contours) based on this analysis. There is also the addition of a Pb-210 background estimate
Submitted: 2012-08-28, last modified: 2013-04-29
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an emphasis on low-mass dark matter candidates (wimp mass of about 10 GeV/c2). We report on the characteristics of the PPC detector presently taking data at the Soudan Underground Laboratory, elaborating on aspects of shielding, data acquisition, instrumental stability, data analysis, and background estimation. A detailed background model is used to investigate the low energy excess of events previously reported, and to assess the possibility of temporal modulations in the low-energy event rate. Extensive simulations of all presently known backgrounds do not provide a viable background explanation for the excess of low-energy events in the CoGeNT data, or the previously observed temporal variation in the event rate. Also reported on for the first time is a determination of the surface (slow pulse rise time) event contamination in the data as a function of energy. We conclude that the CoGeNT detector technology is well suited to search for the annual modulation signature expected from dark matter particle interactions in the region of WIMP mass and coupling favored by the DAMA/LIBRA results
[21]  oai:arXiv.org:1302.6283  [pdf] - 928601
CAST constraints on the axion-electron coupling
Comments:
Submitted: 2013-02-25, last modified: 2013-04-19
In non-hadronic axion models, which have a tree-level axion-electron interaction, the Sun produces a strong axion flux by bremsstrahlung, Compton scattering, and axio-recombination, the "BCA processes." Based on a new calculation of this flux, including for the first time axio-recombination, we derive limits on the axion-electron Yukawa coupling g_ae and axion-photon interaction strength g_ag using the CAST phase-I data (vacuum phase). For m_a < 10 meV/c2 we find g_ag x g_ae< 8.1 x 10^-23 GeV^-1 at 95% CL. We stress that a next-generation axion helioscope such as the proposed IAXO could push this sensitivity into a range beyond stellar energy-loss limits and test the hypothesis that white-dwarf cooling is dominated by axion emission.
[22]  oai:arXiv.org:1303.2686  [pdf] - 668523
Applications of an Y-88/Be photo-neutron calibration source to Dark Matter and Neutrino Experiments
Comments: 3 pages, 4 figures; v2: expanded version. Includes new figure with displaced DAMA/LIBRA ROI obtained using the quenching factors measured
Submitted: 2013-03-11, last modified: 2013-03-17
The low-energy monochromatic neutron emission from an Y-88/Be source can be exploited to mimic the few keVnr nuclear recoils expected from low-mass Weakly Interacting Massive Particles (WIMPs) and coherent scattering of neutrinos off nuclei. Using this source, a ~<10% quenching factor is measured for sodium recoils below 24 keVnr in NaI[Tl]. This is considerably smaller than the 30% typically adopted in the interpretation of the DAMA/LIBRA dark matter experiment, resulting in a marked increase of its tension with other searches, under the standard set of phenomenological assumptions. The method is illustrated for other target materials (superheated and noble liquids).
[23]  oai:arXiv.org:1302.0796  [pdf] - 723037
Quenching and Channeling of Nuclear Recoils in NaI[Tl]: Implications for Dark Matter Searches
Comments: 9 pages, 12 figures v2: minor changes only, version submitted to journal
Submitted: 2013-02-04, last modified: 2013-03-17
A new experimental evaluation of the quenching factor for nuclear recoils in NaI[Tl] is described. Systematics affecting previous measurements are addressed by careful characterization of the emission spectrum of the neutron source, use of a small scintillator coupled to an ultra-bialkali high quantum efficiency photomultiplier, and evaluation of non-linearities in the electron recoil response via Compton scattering. A trend towards a rapidly diminishing quenching factor with decreasing sodium recoil energy is revealed. Additionally, no evidence for crystal lattice channeling of low-energy recoiling ions is found in a scintillator of known crystallographic orientation. A discussion on how these findings affect dark matter searches employing NaI[Tl] (e.g., DAMA/LIBRA) is offered.
[24]  oai:arXiv.org:1210.6282  [pdf] - 1152380
The C-4 Dark Matter Experiment
Comments: 19 pages, 7 figures
Submitted: 2012-10-23, last modified: 2013-02-07
We describe the experimental design of C-4, an expansion of the CoGeNT dark matter search to four identical detectors each approximately three times the mass of the p-type point contact germanium diode presently taking data at the Soudan Underground Laboratory. Expected reductions of radioactive backgrounds and energy threshold are discussed, including an estimate of the additional sensitivity to low-mass dark matter candidates to be obtained with this search.
[25]  oai:arXiv.org:1209.6347  [pdf] - 1453905
Results and perspectives of the solar axion search with the CAST experiment
Comments: 4 pages, 2 pages, to appear in the proceedings of the 24th Rencontres de Blois V2 A few affiliations were not corrected in previous version V3 Author added
Submitted: 2012-09-27, last modified: 2012-10-30
The status of the solar axion search with the CERN Axion Solar Telescope (CAST) will be presented. Recent results obtained by the use of $^3$He as a buffer gas has allowed us to extend our sensitivity to higher axion masses than our previous measurements with $^4$He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV$ \le m_{a} \le $ 0.64 eV. From the absence of an excess of x rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g$_{a\gamma} \le 2.3\times 10^{-10}$ GeV$^{-1}$ at 95% C.L., the exact value depending on the pressure setting. CAST published results represent the best experimental limit on the photon couplings to axions and other similar exotic particles dubbed WISPs (Weakly Interacting Slim Particles) in the considered mass range and for the first time the limit enters the region favored by QCD axion models. Preliminary sensitivities for axion masses up to 1.16 eV will also be shown reaching mean upper limits on the axion-photon coupling of g$_{a\gamma} \le 3.5\times 10^{-10}$ GeV$^{-1}$ at 95% C.L. Expected sensibilities for the extension of the CAST program up to 2014 will be presented. Moreover long term options for a new helioscope experiment will be evoked.
[26]  oai:arXiv.org:1204.3094  [pdf] - 565655
First dark matter search results from a 4-kg CF$_3$I bubble chamber operated in a deep underground site
Comments: 9 pages, 7 figures, 2 tables
Submitted: 2012-04-13, last modified: 2012-09-19
New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha-decay background events from single nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of alpha-decay events. Twenty single nuclear recoil event candidates and three multiple bubble events were observed during a total exposure of 553 kg-days distributed over three different bubble nucleation thresholds. The effective exposure for single bubble recoil-like events was 437.4 kg-days. A neutron background internal to the apparatus, of known origin, is estimated to account for five single nuclear recoil events and is consistent with the observed rate of multiple bubble events. This observation provides world best direct detection constraints on WIMP-proton spin-dependent scattering for WIMP masses $>$20 GeV/c$^{2}$ and demonstrates significant sensitivity for spin-independent interactions.
[27]  oai:arXiv.org:1204.3559  [pdf] - 503190
A Maximum Likelihood Analysis of Low-Energy CDMS Data
Comments: 5 pages, 4 figures v2: minor additions only v3: expanded discussion on surface events (pg. 3)
Submitted: 2012-04-16, last modified: 2012-04-21
An unbinned maximum likelihood analysis of CDMS low-energy data reveals a strong preference (5.7 sigma C.L.) for a model containing an exponential excess of events in the nuclear recoil band, when compared to the null hypothesis. We comment on the possible origin of such an excess, establishing a comparison with anomalies in other dark matter experiments. A recent annual modulation search in CDMS data is shown to be insufficiently sensitive to test a dark matter origin for this excess.
[28]  oai:arXiv.org:1106.0650  [pdf] - 669552
Search for an Annual Modulation in a P-type Point Contact Germanium Dark Matter Detector
Comments: Published version, slightly expanded discussion of ROI uncertainties, one reference added
Submitted: 2011-06-03, last modified: 2011-10-04
Fifteen months of cumulative CoGeNT data are examined for indications of an annual modulation, a predicted signature of Weakly Interacting Massive Particle (WIMP) interactions. Presently available data support the presence of a modulated component of unknown origin, with parameters prima facie compatible with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield a statistical significance for a modulation of ~2.8 sigma, limited by the short exposure.
[29]  oai:arXiv.org:1106.3559  [pdf] - 374685
Comments on "Final Analysis and Results of the Phase II SIMPLE Dark Matter Search"
Comments:
Submitted: 2011-06-17
The SIMPLE collaboration has recently claimed improved limits on WIMP-nucleus couplings (arXiv:1106.3014). The limited shelf-life of SIMPLE detectors and apparent deficiencies in the acoustic background discrimination method employed severely affect the credibility of these claims.
[30]  oai:arXiv.org:1106.0653  [pdf] - 372516
A Realistic Assessment of the Sensitivity of XENON10 and XENON100 to Light-Mass WIMPs
Comments: Fig. 1 updated to include new ZEPLIN-III measurements of Leff (arXiv:1106.0694). Version submitted for publication. v3: minor mistakes in calls to new Fig. 1 corrected
Submitted: 2011-06-03, last modified: 2011-06-13
The underlaying assumptions and uncertainties involved in the derivation of WIMP exclusion limits from XENON10 and XENON100 detectors are examined. In view of these, recent claims of sensitivity to light-mass Weakly Interacting Massive Particles (WIMPs) are shown to be overstated. Specifically, bounds constraining regions of interest in WIMP parameter space from the DAMA/LIBRA, CoGeNT and CRESST experiments can be assigned a very limited meaning, if any.
[31]  oai:arXiv.org:1103.3481  [pdf] - 332590
A comparison between the low-energy spectra from CoGeNT and CDMS
Comments:
Submitted: 2011-03-17
A side-to-side comparison is established between the nuclear recoil energy spectrum from CDMS germanium bolometers and its low-energy equivalent for events in the inner bulk volume of a CoGeNT germanium diode. Acknowledging the orthogonality of the background cuts possible with each type of detector and following an examination of the uncertainties in these searches, a suggestive agreement between these spectra is observed.
[32]  oai:arXiv.org:1008.3518  [pdf] - 326586
Improved Limits on Spin-Dependent WIMP-Proton Interactions from a Two Liter CF$_3$I Bubble Chamber
Comments: 4 pages, 4 figures V2 submitted to match journal version
Submitted: 2010-08-20, last modified: 2011-03-07
Data from the operation of a bubble chamber filled with 3.5 kg of CF$_{3}$I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during an effective exposure of 28.1 kg-day, consistent with a neutron background. This observation provides the strongest direct detection constraint to date on WIMP-proton spin-dependent scattering for WIMP masses $>20$ GeV/c$^{2}$.
[33]  oai:arXiv.org:1007.1005  [pdf] - 283573
A Consistent Dark Matter Interpretation For CoGeNT and DAMA/LIBRA
Comments: 8 pages, 6 figures
Submitted: 2010-07-06, last modified: 2010-10-27
In this paper, we study the recent excess of low energy events observed by the CoGeNT collaboration and the annual modulation reported by the DAMA/LIBRA collaboration, and discuss whether these signals could both be the result of the same elastically scattering dark matter particle. We find that, without channeling but when taking into account uncertainties in the relevant quenching factors, a dark matter candidate with a mass of approximately ~7.0 GeV and a cross section with nucleons of sigma_{DM-N} ~2x10^-4 pb (2x10^-40 cm^2) could account for both of these observations. We also comment on the events recently observed in the oxygen band of the CRESST experiment and point out that these could potentially be explained by such a particle. Lastly, we compare the region of parameter space favored by DAMA/LIBRA and CoGeNT to the constraints from XENON 10, XENON 100, and CDMS (Si) and find that these experiments cannot at this time rule out a dark matter interpretation of these signals.
[34]  oai:arXiv.org:1010.5187  [pdf] - 247686
Light WIMP Searches: The Effect of the Uncertainty in Recoil Energy Scale and Quenching Factor
Comments: 11 pages
Submitted: 2010-10-25
Taking liquid xenon detectors as a case study, the importance of a robust recoil energy calibration as a prerequisite to a search for light-mass Weakly Interacting Massive Particles (WIMPs) is emphasized. Important shortfalls in the analysis of existing measurements of the relative scintillation efficiency and ionization yield for nuclear recoils in liquid xenon are described, leading to the conclusion that recent attempts to extract light-WIMP sensitivity limits from the XENON10 and XENON100 detectors are premature and overly optimistic.
[35]  oai:arXiv.org:1006.2031  [pdf] - 188115
Comments on arXiv:1006.0972 "XENON10/100 dark matter constraints in comparison with CoGeNT and DAMA: examining the Leff dependence"
Comments: 2 pages
Submitted: 2010-06-09
Savage et al. have recently put forward the claim that results from the XENON10 experiment are incompatible with the totality of both DAMA/LIBRA and CoGeNT experimental regions. In this brief note the source of this erroneous conclusion is identified in a misinterpretation of the XENON10 efficiency in the detection of S1 light from low-energy nuclear recoils.
[36]  oai:arXiv.org:1005.3723  [pdf] - 169132
Response to arXiv:1005.2615
Comments:
Submitted: 2010-05-20
Brief response to a Reply [arXiv:1005.2615] on our Comments [arXiv:1005.0838] on XENON100 recent results [arXiv:1005.0380].
[37]  oai:arXiv.org:1005.0838  [pdf] - 164844
Comments on "First Dark Matter Results from the XENON100 Experiment"
Comments: v3: Figures and appendix added showing the effect of choice of Leff on claimed sensitivity. v2:Important information added to a footnote. Figures enlarged, references fixed
Submitted: 2010-05-05, last modified: 2010-05-12
The XENON100 collaboration has recently released new dark matter limits, placing particular emphasis on their impact on searches known to be sensitive to light-mass (below 10 GeV/c^2) Weakly Interacting Massive Particles (WIMPs), such as DAMA and CoGeNT. We describe here several sources of uncertainty and bias in their analysis that make their new claimed sensitivity presently untenable. In particular, we point out additional work in this field and simple kinematic arguments that indicate that liquid xenon (LXe) may be a relatively insensitive detection medium for the recoil energies (few keV_r) expected from such low mass WIMPs.
[38]  oai:arXiv.org:1002.4703  [pdf] - 339357
Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector
Comments: 4 pages, 4 figures. v2: submitted version. Minimal changes in wording, one reference added
Submitted: 2010-02-25, last modified: 2010-03-15
We report on several features present in the energy spectrum from an ultra low-noise germanium detector operated at 2,100 m.w.e. By implementing a new technique able to reject surface events, a number of cosmogenic peaks can be observed for the first time. We discuss several possible causes for an irreducible excess of bulk-like events below 3 keVee, including a dark matter candidate common to the DAMA/LIBRA annual modulation effect, the hint of a signal in CDMS, and phenomenological predictions. Improved constraints are placed on a cosmological origin for the DAMA/LIBRA effect.
[39]  oai:arXiv.org:0903.5068  [pdf] - 22863
Comments on arXiv:0902.4693v1 "Search for Axions with the CDMS Experiment"
Comments:
Submitted: 2009-03-29
We offer a few remarks that should help clarify the relative sensitivity of CoGeNT, CDMS and DAMA to dark pseudoscalars. An alternative dark matter origin for the DAMA modulation is briefly mentioned within this context.
[40]  oai:arXiv.org:0806.1341  [pdf] - 13353
Additional Comments on "New Limits on Spin-Independent Couplings of Low-Mass WIMP Dark Matter with a Germanium Detector at a Threshold of 200 eV"
Comments: Additional comments on arXiv:0712.1645v2. We find that systematics have been neglected through a combination of erroneous assumptions and failure to explore all of their sources
Submitted: 2008-06-08, last modified: 2008-08-09
In a previous comment (arXiv:0806.1341v1) we criticized purely technical aspects of arXiv:0712.1645 but pointed out that many other inconsistencies were readily apparent. In view of the imminent posting of another version of arXiv:0712.1645, still containing these issues, we would like to offer with this additional note a critical guide to the methodology followed by the TEXONO collaboration, in their effort to extract dark matter limits from a spectral region completely dominated by electronic noise. We find that systematics have been neglected through a combination of erroneous assumptions and failure to explore all of their possible sources.
[41]  oai:arXiv.org:0807.0879  [pdf] - 14236
Experimental constraints on a dark matter origin for the DAMA annual modulation effect
Comments: v4: introduces recent results from arXiv:0807.3279 and arXiv:0807.2926. Sensitivity to pseudoscalars is revised in light of the first. Discussion on the subject added
Submitted: 2008-07-05, last modified: 2008-07-31
A claim for evidence of dark matter interactions in the DAMA experiment has been recently reinforced. We employ a new type of germanium detector to conclusively rule out a standard isothermal galactic halo of Weakly Interacting Massive Particles (WIMPs) as the explanation for the annual modulation effect leading to the claim. Bounds are similarly imposed on a suggestion that dark pseudoscalars mightlead to the effect. We describe the sensitivity to light dark matter particles achievable with our device, in particular to Next-to-Minimal Supersymmetric Model candidates.
[42]  oai:arXiv.org:0804.2886  [pdf] - 11873
Improved Spin-Dependent WIMP Limits from a Bubble Chamber
Comments: This is the author's version of the work. It is posted here by permission of the AAAS for personal use, not for redistribution. The definitive version was published in Science 319, 15 February 2008, doi:10.1126/science.1149999
Submitted: 2008-04-17
Bubble Chambers provided the dominant particle detection technology in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on the first period of operation of an ultra-clean, room-temperature bubble chamber containing 1.5 kg of superheated CF$_{3}$I, a target maximally sensitive to spin-dependent and -independent Weakly Interacting Massive Particle (WIMP) couplings. An exposure in excess of 250 kg-days is obtained, with a live-time fraction reaching 80%. This illustrates the ability to employ bubble chambers in a new realm, the search for dark matter particles. Improved limits on the spin-dependent WIMP-proton scattering cross section are extracted from this first period. An extreme intrinsic insensitivity to the backgrounds commonly limiting these experiments (a rejection factor for photon-induced electrons of $\sim10^{-10}$) has been measured in operating conditions leading to the detection of low-energy nuclear recoils such as those expected from WIMPs.
[43]  oai:arXiv.org:0705.2502  [pdf] - 1359
WIMP identification through a combined measurement of axial and scalar couplings
Comments: 4 pages 2 figures, uses revtex. References added and Fig.2 improved. To appear in PRL
Submitted: 2007-05-17, last modified: 2007-07-23
We study the prospects for detecting Weakly Interacting Massive Particles (WIMPs), in a number of phenomenological scenarios, with a detector composed of a target simultaneously sensitive to both spin-dependent and spin-independent couplings, as is the case of COUPP (Chicagoland Observatory for Underground Particle Physics). First, we show that sensitivity to both couplings optimizes chances of initial WIMP detection. Second, we demonstrate that in case of detection, comparison of the signal on two complementary targets, such as in COUPP CF3I and C4F10 bubble chambers, allows a significantly more precise determination of the dark matter axial and scalar couplings. This strategy would provide crucial information on the nature of the WIMPs, and possibly allow discrimination between neutralino and Kaluza-Klein dark matter.
[44]  oai:arXiv.org:nucl-ex/0701012  [pdf] - 358365
Large-Mass Ultra-Low Noise Germanium Detectors: Performance and Applications in Neutrino and Astroparticle Physics
Comments: submitted to Phys. Rev. C
Submitted: 2007-01-07
A new type of radiation detector, a p-type modified electrode germanium diode, is presented. The prototype displays, for the first time, a combination of features (mass, energy threshold and background expectation) required for a measurement of coherent neutrino-nucleus scattering in a nuclear reactor experiment. The device hybridizes the mass and energy resolution of a conventional HPGe coaxial gamma spectrometer with the low electronic noise and threshold of a small x-ray semiconductor detector, also displaying an intrinsic ability to distinguish multiple from single-site particle interactions. The present performance of the prototype and possible further improvements are discussed, as well as other applications for this new type of device in neutrino and astroparticle physics (double-beta decay, neutrino magnetic moment and WIMP searches).
[45]  oai:arXiv.org:nucl-ex/0701011  [pdf] - 118490
Design and Characterization of a Neutron Calibration Facility for the Study of sub-keV Nuclear Recoils
Comments: submitted to Nucl. Instr. Meth. A
Submitted: 2007-01-06
As part of an experimental effort to demonstrate sensitivity in a large-mass detector to the ultra-low energy recoils expected from coherent neutrino-nucleus elastic scattering, we have designed and built a highly monochromatic 24 keV neutron beam at the Kansas State University Triga Mark-II reactor. The beam characteristics were chosen so as to mimic the soft recoil energies expected from reactor antineutrinos in a variety of targets, allowing to understand the response of dedicated detector technologies in this yet unexplored sub-keV recoil range. A full characterization of the beam properties (intensity, monochromaticity, contaminations, beam profile) is presented, together with first tests of the calibration setup using proton recoils in organic scintillator.
[46]  oai:arXiv.org:astro-ph/0503398  [pdf] - 358287
Development of Bubble Chambers With Enhanced Stability and Sensitivity to Low-Energy Nuclear Recoils
Comments: 4 pages, 3 figures. Submitted to Phys. Rev. Lett
Submitted: 2005-03-17
The viability of using a Bubble Chamber for rare event searches and in particular for the detection of dark matter particle candidates is considered. Techniques leading to the deactivation of inhomogeneous nucleation centers and subsequent enhanced stability in such a detector are described. Results from prototype trials indicate that sensitivity to low-energy nuclear recoils like those expected from Weakly Interacting Massive Particles can be obtained in conditions of near total insensitivity to minimum ionizing backgrounds. An understanding of the response of superheated heavy refrigerants to these recoils is demonstrated within the context of existing theoretical models. We comment on the prospects for the detection of supersymmetric dark matter particles with a large $CF_{3}I$ chamber.
[47]  oai:arXiv.org:hep-ex/0304024  [pdf] - 113352
CAST: A search for solar axions at CERN
Comments: Presented at the SPIE conference on Astronomical Telescopes and Instrumentation, Waikoloa, Hawaii, 2002. 5 pages, 4 figures
Submitted: 2003-04-15
The new axion helioscope at CERN started acquiring data during September of 2002: CAST (Cern Axion Solar Telescope) employs a decommissioned LHC dipole magnet to convert putative solar axions or axion-like particles into detectable photons. The unprecedented dipole magnet intensity and length (9.5 T, 10 m) results in a projected sensitivity that surpasses astrophysical constraints on these particles for the first time, increasing the chance of discovery. The use of X-ray focusing optics and state-of-the-art detector technology has led to an extremely low background for an experiment above ground. A brief status report is given, with emphasis on the tracking and control system and possible future extensions.
[48]  oai:arXiv.org:hep-ex/0304013  [pdf] - 358345
A First Mass Production of Gas Electron Multipliers
Comments: 11 pages, 10 figures, to be submitted to Nucl. Instr. Meth. A
Submitted: 2003-04-07
We report on the manufacture of a first batch of approximately 2,000 Gas Electron Multipliers (GEMs) using 3M's fully automated roll to roll flexible circuit production line. This process allows low-cost, reproducible fabrication of a high volume of GEMs of dimensions up to 30$\times$30 cm$^{2}$. First tests indicate that the resulting GEMs have optimal properties as radiation detectors. Production techniques and preliminary measurements of GEM performance are described. This now demonstrated industrial capability should help further establish the prominence of micropattern gas detectors in accelerator based and non-accelerator particle physics, imaging and photodetection.
[49]  oai:arXiv.org:hep-ex/0212034  [pdf] - 358344
Towards Coherent Neutrino Detection Using Low-Background Micropattern Gas Detectors
Comments: Presented at the 2002 IEEE Nuclear Science Symposium and Medical Imaging Conference, Norfolk VA, November 10-16. Submitted to IEEE Tran. Nucl. Sci. Five pages, eight figures
Submitted: 2002-12-13
The detection of low energy neutrinos ($<$ few tens of MeV) via coherent nuclear scattering remains a holy grail of sorts in neutrino physics. This uncontroversial mode of interaction is expected to profit from a sizeable increase in cross section proportional to neutron number squared in the target nucleus, an advantageous feature in view of the small probability of interaction via all other channels in this energy region. A coherent neutrino detector would open the door to many new applications, ranging from the study of fundamental neutrino properties to true "neutrino technology". Unfortunately, present-day radiation detectors of sufficiently large mass ($>$ 1 kg) are not sensitive to sub-keV nuclear recoils like those expected from this channel. The advent of Micropattern Gas Detectors (MPGDs), new technologies originally intended for use in High Energy Physics, may soon put an end to this impasse. We present first tests of MPGDs fabricated with radioclean materials and discuss the approach to assessing their sensitivity to these faint signals. Applications are reviewed, in particular their use as a safeguard against illegitimate operation of nuclear reactors. A first industrial mass production of Gas Electron Multipliers (GEMs) is succinctly described.
[50]  oai:arXiv.org:hep-ex/0105015  [pdf] - 113340
A new approach to neutrino and WIMP detection using telecom-grade electrooptic and fiber-optic components
Comments: Preliminary version. Expanded version soon to follow
Submitted: 2001-05-09
The dense energy deposition from a low-energy nuclear recoil produces, via the thermoacoustic effect, a brief yet intense pressure pulse that can be used for WIMP or neutrino detection in some fiber-optic devices sensitive to acoustooptic disturbances. Several possible detection schemes are described: all of them are inspired by modern fiber-optic sensor technologies and share common characteristics of low-cost and expected insensitivity to minimum-ionizing backgrounds.
[51]  oai:arXiv.org:hep-ex/0009063  [pdf] - 387150
Low-background applications of MICROMEGAS detector technology
Comments: 5 pg, presented at IMAGING-2000, Stockholm, June 2000. To appear in Nucl. Instr. & Meth. Final version after referees' input
Submitted: 2000-09-28, last modified: 2001-01-17
The MICROMEGAS detector concept, generally optimized for use in accelerator experiments, displays a peculiar combination of features that can be advantageous in several astroparticle and neutrino physics applications. Their sub-keV ionization energy threshold, excellent energy and space resolution, and a simplicity of design that allows the use of radioclean materials in their construction are some of these characteristics. We envision tackling experimental challenges such as the measurement of neutral-current neutrino-nucleus coherent scattering or Weakly Interacting Massive Particle (WIMP) detectors with directional sensitivity. The large physics potential of a compact (total volume O(1)m$^{3}$), multi-purpose array of low-background MICROMEGAS is made evident.
[52]  oai:arXiv.org:astro-ph/0101176  [pdf] - 1507852
WIMP searches with superheated droplet detectors: Status and Prospects
Comments: 6 pages LaTeX, incl. 2 figures. Presented at the 3rd Intl. Workshop for the Identification of Dark Matter (IDM2000), York, Sept. 2000
Submitted: 2001-01-11, last modified: 2001-01-14
SIMPLE (Superheated Instrument for Massive ParticLE searches) employs superheated droplet detectors (SDDs) to search for Weakly Interacting Massive Particle (WIMP) dark matter. As a result of the intrinsic SDD insensitivity to minimum ionizing particles and high fluorine content of target liquids, competitive WIMP limits were already obtained at the early prototype stage. We comment here on the expected immediate increase in sensitivity of the program and on future plans to exploit this promising technnique.
[53]  oai:arXiv.org:astro-ph/0001511  [pdf] - 34308
First Dark Matter Limits from a Large-Mass, Low-Background Superheated Droplet Detector
Comments: Final version, Phys. Rev. Lett. (in press)
Submitted: 2000-01-28, last modified: 2000-09-29
We report on the fabrication aspects and calibration of the first large active mass ($\sim15$ g) modules of SIMPLE, a search for particle dark matter using Superheated Droplet Detectors (SDDs). While still limited by the statistical uncertainty of the small data sample on hand, the first weeks of operation in the new underground laboratory of Rustrel-Pays d'Apt already provide a sensitivity to axially-coupled Weakly Interacting Massive Particles (WIMPs) competitive with leading experiments, confirming SDDs as a convenient, low-cost alternative for WIMP detection.
[54]  oai:arXiv.org:astro-ph/0005059  [pdf] - 35831
Prospects for SIMPLE 2000: A large-mass, low-background Superheated Droplet Detector for WIMP searches
Comments: 19 pages, 10 figures included. New Journal of Physics, in press
Submitted: 2000-05-03
SIMPLE 2000 (Superheated Instrument for Massive ParticLE searches) will consist of an array of eight to sixteen large active mass ($\sim15$ g) Superheated Droplet Detectors(SDDs) to be installed in the new underground laboratory of Rustrel-Pays d'Apt. Several factors make of SDDs an attractive approach for the detection of Weakly Interacting Massive Particles (WIMPs), namely their intrinsic insensitivity to minimum ionizing particles, high fluorine content, low cost and operation near ambient pressure and temperature. We comment here on the fabrication, calibration and already-competitive first limits from SIMPLE prototype SDDs, as well as on the expected immediate increase in sensitivity of the program, which aims at an exposure of $>$25 kg-day during the year 2000. The ability of modest-mass fluorine-rich detectors to explore regions of neutralino parameter space beyond the reach of the most ambitious cryogenic projects is pointed out.
[55]  oai:arXiv.org:astro-ph/9910192  [pdf] - 108746
First Characterization of the Ultra-Shielded Chamber in the Low-noise Underground Laboratory (LSBB) of Rustrel Pays d'Apt
Comments: Homepage and quoted hyperlinks have been updated: see http://home.cern.ch/collar/RUSTREL/rustrel.html
Submitted: 1999-10-11, last modified: 1999-10-13
In compliance with international agreements on nuclear weapons limitation, the French ground-based nuclear arsenal has been decommissioned in its totality. One of its former underground missile control centers, located in Rustrel, 60 km east of Avignon (Provence) has been converted into the ``Laboratoire Souterrain \`a Bas Bruit de Rustrel-Pays d'Apt'' (LSBB). The deepest experimental hall (500 m of calcite rock overburden) includes a 100 m$^{2}$ area of sturdy flooring suspended by and resting on shock absorbers, entirely enclosed in a 28 m-long, 8 m-diameter, 1 cm-thick steel Faraday cage. This results in an unparalleled combination of shielding against cosmic rays, acoustic, seismic and electromagnetic noise, which can be exploited for rare event searches using ultra low-temperature and superconducting detectors. The first characterization measurements in this unique civilian site are reported. For more info see http://home.cern.ch/collar/RUSTREL/rustrel.html
[56]  oai:arXiv.org:astro-ph/9902310  [pdf] - 105329
Constraints on Exotic Heavily Ionizing Particles from the Geological Abundance of Fullerenes
Comments: Final version (few modifications). Phys. Rev. Lett. (in press). 4 pages LaTeX, 1 eps figure embedded
Submitted: 1999-02-22, last modified: 1999-08-31
The C_{60} molecule exhibits a remarkable stability and inertness that leads to its survival in ancient carbonaceous rocks initially subject to the high temperatures requisite for its formation. Elementary particles having very high electronic stopping powers can similarly form C_{60} and higher fullerenes in their wake. Combined, these two features point at the possibility of using the C_{60} presence (or absence) in selected bulk geological samples as a new type of solid-state nuclear track detector, with applications in astro-particle physics.
[57]  oai:arXiv.org:hep-ph/9611420  [pdf] - 115950
Endpoint Structure in Beta Decay from Coherent Weak-Interaction of the Neutrino
Comments: Small paragraph added with estimate of {\it quantitative} effect of the potential on experimental data. References to recent relevant publications added. LaTeX, 3 pages, 2 enbedded eps figs
Submitted: 1996-11-25, last modified: 1999-07-09
Recent tritium beta decay experiments yield unphysical negative best-fit values for the square of the neutrino mass. An unidentified bump-like excess of counts few eV below the endpoint in the electron energy spectrum has been tentatively recognized as the source of this anomaly. It is shown that the repulsive potential acting on the emitted antineutrino and originating in its coherent weak-interaction with the daughter atom may effectively account for this excess.
[58]  oai:arXiv.org:astro-ph/9808058  [pdf] - 102402
Solar-bound weakly interacting massive particles: a no-frills phenomenology
Comments: Final version, accepted for publication in Phys. Rev. D. (16 pages, including 4 figures, gzipped postscript)
Submitted: 1998-08-07, last modified: 1999-01-22
The case for a stable population of solar-bound Earth-crossing Weakly Interacting Massive Particles (WIMPs) is reviewed. A practical general expression for their speed distribution in the laboratory frame is derived under basic assumptions. If such a population exists -even with a conservative phase-space density-, the next generation of large-mass, low-threshold underground bolometers should bring about a sizable enhancement in WIMP sensitivity. Finally, a characteristic yearly modulation in their recoil signal, arising from the ellipticity of the Earth's orbit, is presented.
[59]  oai:arXiv.org:astro-ph/9801176  [pdf] - 100025
A Decommissioned LHC Model Magnet as an Axion Telescope
Comments: Final version, accepted for publication in Nucl. Instr. Meth. A. More information can be found at http://wwwinfo.cern.ch/~collar/SATAN/alvaro.html
Submitted: 1998-01-18, last modified: 1999-01-22
The 8.4 Tesla, 10 m long transverse magnetic field of a twin aperture LHC bending magnet can be utilized as a macroscopic coherent solar axion-to-photon converter. Numerical calculations show that the integrated time of alignment with the Sun would be 33 days per year with the magnet on a tracking table capable of $\pm 5^o$ in the vertical direction and $\pm 40^o$ in the horizontal direction. The existing lower bound on the axion-to-photon coupling constant can be improved by a factor between 50 and 100 in 3 years, i.e., $g_{a\gamma\gamma} \lesssim 9\cdot 10^{-11} GeV^{-1}$ for axion masses $\lesssim$ 1 eV. This value falls within the existing open axion mass window. The same set-up can simultaneously search for low- and high-energy celestial axions, or axion-like particles, scanning the sky as the Earth rotates and orbits the Sun.
[60]  oai:arXiv.org:astro-ph/9809018  [pdf] - 102722
Search for an annual modulation of dark-matter signals with a germanium spectrometer at the Sierra Grande Laboratory
Comments: New version accepted by Astroparticle Physics. Changes suggested by the referee about the theoretical prediction of rates are included. Conclusions remain unaffected. 14 pages, LaTeX, 7 figures. Uses epsfig macro
Submitted: 1998-09-02, last modified: 1998-09-14
Data collected during three years with a germanium spectrometer at the Sierra Grande underground laboratory have been analyzed for distinctive features of annual modulation of the signal induced by WIMP dark matter candidates. The main motivation for this analysis was the recent suggestion by the DAMA/NaI Collaboration that a yearly modulation signal could not be rejected at the 90% confidence level when analyzing data obtained with a high-mass low-background scintillator detector. We performed two different analyses of the data: First, the statistical distribution of modulation-significance variables (expected from an experiment running under the conditions of Sierra Grande) was compared with the same variables obtained from the data. Second, the data were analyzed in energy bins as an independent check of the first result and to allow for the possibility of a crossover in the expected signal. In both cases no statistically significant deviation from the null result was found, which could support the hypothesis that the data contain a modulated component. A plot is also presented to enable the comparison of these results to those of the DAMA collaboration.
[61]  oai:arXiv.org:astro-ph/9712308  [pdf] - 1235170
Experimental Search for Solar Axions
Comments: List of authors now complete. 5 pages (A4), LaTex, 4 PS figures, uses epsf and espcrc2(included) macros. Talk at the 5th International Workshop on ``Topics in Astroparticle and Underground Physics'' (TAUP97), Gran Sasso, Italy, 7-11 September, 1997, to appear in the Proceedings, Nucl. Phys. B(PS), A. Bottino, A. di Credico and P. Monacelli (eds.)
Submitted: 1997-12-23, last modified: 1997-12-26
A new technique has been used to search for solar axions using a single crystal germanium detector. It exploits the coherent conversion of axions into photons when their angle of incidence satisfies a Bragg condition with a crystalline plane. The analysis of approximately 1.94 kg.yr of data from the 1-kg DEMOS detector in Sierra Grande, Argentina, yields a new laboratory bound on axion-photon coupling of g_{a,\gamma\gamma}<2.7\times 10^{-9} GeV^{-1} independent of axion mass up to \sim 1 keV.
[62]  oai:arXiv.org:hep-ph/9708210  [pdf] - 116055
Theory for the Direct Detection of Solar Axions by Coherent Primakoff Conversion in Germanium Detectors
Comments: gzipped postscript file from Microsoft Word, 8 pages. Figures can be obtained by fax from Juan.Collar@cern.ch. Submitted to Phys. Lett. B
Submitted: 1997-08-01
It is assumed that axions exist and are created in the Sun by Primakoff conversion of photons in the Coulomb fields of nuclei. Detection rates are calculated in germanium detectors due to the coherent conversion of axions to photons in the lattice when the incident angle fulfills the Bragg condition for a given crystalline plane. The rates are correlated with the relative positions of the Sun and detector, yielding a characteristic recognizable sub-diurnal temporal pattern. A major experiment is proposed based on a large detector array.
[63]  oai:arXiv.org:astro-ph/9708008  [pdf] - 98186
Experimental Search for Solar Axions via Coherent Primakoff Conversion in a Germanium Spectrometer
Comments: RevTeX, 11 pages, figures can be obtained by fax from Juan.Collar@cern.ch. Submitted to Phys. Lett. B
Submitted: 1997-08-01
Results are reported of an experimental search for the unique, rapidly varying temporal pattern of solar axions coherently converting into photons via the Primakoff effect in a single crystal germanium detector. This conversion is predicted when axions are incident at a Bragg angle with a crystalline plane. The analysis of approximately 1.94 kg.yr of data from the 1 kg DEMOS detector in Sierra Grande, Argentina, yields a new laboratory bound on axion-photon coupling of $g_{a\gamma \gamma} < 2.7\cdot 10^{-9}$ GeV$^{-1}$, independent of axion mass up to ~ 1 keV.
[64]  oai:arXiv.org:astro-ph/9702165  [pdf] - 96684
Cold dark matter identification: Diurnal modulation reexamined
Comments: One change of author and minor revisions to match published version in Phys. Rev. D. LaTeX 6 pages, 8 Postscript figures
Submitted: 1997-02-19, last modified: 1997-07-29
We report on new estimates of the modulation expected in semiconductor detectors due to eclipsing of dark matter particles in the Earth. We reevaluate the theoretical modulation significances and discuss the differences found with previous calculations. We find that a significantly larger statistics than previously estimated is needed to achieve the same level of sensitivity in the modulated signal.
[65]  oai:arXiv.org:astro-ph/9702026  [pdf] - 96545
Reply to astro-ph/9612003 ("Comments on 'Biological Effects of Stellar Collapse Neutrinos'") and astro-ph/9612214 ("Volcanogenic Dark Matter and Mass Extinctions")
Comments: Postscript, 4 pages, no figures
Submitted: 1997-02-03
A Reply to the criticisms contained in astro-ph/9612003 is provided and a logical inconsistency in astro-ph/9612214 is pointed out.
[66]  oai:arXiv.org:astro-ph/9610266  [pdf] - 95790
Superheated Droplet Detectors as CDM Detectors: The SIMPLE Experiment
Comments: 6 pages, including 4 figures. To appear in the Proceedings of the Intl. Workshop on the Identification of Dark Matter (Sheffield, Sept. 96)
Submitted: 1996-10-31
Superheated Droplet Detectors (SDDs) are becoming commonplace in neutron personnel dosimetry. Their total insensitivity to minimum ionizing radiation (while responsive to nuclear recoils of energies ~ few keV), together with their low cost, ease of production, and operation at room temperature and 1 atm makes them ideal for Cold Dark Matter (CDM) searches. SDD's are optimal for the exploration of the spin-dependent neutralino coupling due to their high fluorine content. The status of SIMPLE (Superheated Instrument for Massive ParticLe Experiments) is presented. Under realistic background considerations, we expect an improvement in the present Cold Dark Matter sensitivity of 2-3 orders of magnitude after ~1 kg-y of data acquisition.
[67]  oai:arXiv.org:astro-ph/9607150  [pdf] - 95092
Superheated Microdrops as Cold Dark Matter Detectors
Comments: 15 pgs, 4 figures included
Submitted: 1996-07-29
It is shown that under realistic background considerations, an improvement in Cold Dark Matter sensitivity of several orders of magnitude is expected from a detector based on superheated liquid droplets. Such devices are totally insensitive to minimum ionizing radiation while responsive to nuclear recoils of energies ~ few keV. They operate on the same principle as the bubble chamber, but offer unattended, continuous, and safe operation at room temperature and atmospheric pressure.
[68]  oai:arXiv.org:astro-ph/9512054  [pdf] - 93738
Clumpy Cold Dark Matter and Biological Extinctions
Comments: Compressed PostScript (filename.ps.Z), 8 pages, including 2 figures
Submitted: 1995-12-10
Cosmological models with cosmic string and texture seeded universes predict a present abundance of very dense clumps of Cold Dark Matter particles. Their crossing through the solar system would induce a non-negligible amount of radiation damage to all living tissue; the severity of such an episode is assessed. The estimated frequency of these crossings agrees with the apparent periodicity of the paleontological record of biological extinctions. (Phys. Lett. B, in press)
[69]  oai:arXiv.org:astro-ph/9505028  [pdf] - 92670
Biological Effects of Stellar Collapse Neutrinos
Comments: gzipped PostScript (filename.ps.Z), 12 pages. Final version, Phys. Rev. Lett., in press
Submitted: 1995-05-05, last modified: 1995-12-01
Massive stars in their final stages of collapse radiate most of their binding energy in the form of MeV neutrinos. The recoil atoms that they produce in elastic scattering off nuclei in organic tissue create radiation damage which is highly effective in the production of irreparable DNA harm, leading to cellular mutation, neoplasia and oncogenesis. Using a conventional model of the galaxy and of the collapse mechanism, the periodicity of nearby stellar collapses and the radiation dose are calculated. The possible contribution of this process to the paleontological record of mass extinctions is examined.
[70]  oai:arXiv.org:astro-ph/9511055  [pdf] - 93589
Comments on "Limits on Dark Matter Using Ancient Mica"
Comments: Compressed PostScript (filename.ps.Z), 3 pages, no figures
Submitted: 1995-11-13
To appear in Phys. Rev. Lett. together with the author's Reply.
[71]  oai:arXiv.org:astro-ph/9505058  [pdf] - 92700
Surface Sputtering from Cold Dark Matter Interactions: Proposed Search for its Diurnal Modulation
Comments: Compressed PostScript, 27 pages, 8 figures included (Astropart. Phys., in press)
Submitted: 1995-05-12
Nuclear recoil cascades induced by Cold Dark Matter (CDM) elastic scattering can produce the ejection of target atoms from solid surfaces. We calculate the yield and energy distribution of these sputtered atoms in a variety of materials. These parameters would suffer a large diurnal modulation induced by the rotation of the Earth and its motion through the galactic halo. Schemes for the detection of this unique CDM signature are proposed.
[72]  oai:arXiv.org:astro-ph/9505055  [pdf] - 92697
Nuclear Tracks from Cold Dark Matter Interactions in Mineral Crystals: A Computational Study
Comments: PostScript, 15 pages, 3 figures
Submitted: 1995-05-11, last modified: 1995-05-12
Recoiling nuclei from Cold Dark Matter (CDM) elastic scattering interactions with the constituent elements of some minerals may produce etchable damage tracks in the crystal structure. Present calculations show that in muscovite mica, CDM tracks from recoiling potassium atoms could be readily distinguished from others due to alpha-decays in the uranium and thorium chains. Under favorable conditions, this technique could greatly improve the existing limits on Weakly Interacting Massive Particles as the constituents of the galactic halo.
[73]  oai:arXiv.org:astro-ph/9311049  [pdf] - 91073
Effects of Diurnal Modulation in Direct Cold Dark Matter Searches. the Experiment in Sierra Grande
Comments: 10 pp. + 10 figures RevTeX 3.0, 8.7kb, TAN-FNT-93-16
Submitted: 1993-11-18
Contains a summary, current status and prospects for the direct detection of cold dark matter using diurnal modulation effects as presented at the ELAF 93, Mar del Plata Argentina. The potential advantages of using the Earth as an absorber to produce diurnal modulation effects in cold dark matter searches are given along with some estimates of counting rates.