Normalized to: Colin, A.
[1]
oai:arXiv.org:1005.2541 [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument
flight model radiometers
Villa, F.;
Terenzi, L.;
Sandri, M.;
Meinhold, P.;
Poutanen, T.;
Battaglia, P.;
Franceschet, C.;
Hughes, N.;
Laaninen, M.;
Lapolla, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Balasini, M.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Cappellini, B.;
Cavaliere, F.;
Colin, A.;
Colombo, F.;
Davis, R. J.;
De La Fuente, L.;
Edgeley, J.;
Gaier, T.;
Galtress, A.;
Hoyland, R.;
Jukkala, P.;
Kettle, D.;
Kilpia, V-H.;
Lawrence, C. R.;
Lawson, D.;
Leahy, J. P.;
Leutenegger, P.;
Levin, S.;
Maino, D.;
Malaspina, M.;
Mediavilla, A.;
Miccolis, M.;
Pagan, L.;
Pascual, J. P.;
Pasian, F.;
Pecora, M.;
Pospieszalski, M.;
Roddis, N.;
Salmon, M. J.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Sozzi, C.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
[2]
oai:arXiv.org:1001.4653 [pdf] - 33163
Thermal susceptibility of the Planck-LFI receivers
Terenzi, L;
Salmon, M J;
Colin, A;
Mennella, A;
Morgante, G;
Tomasi, M;
Battaglia, P;
Lapolla, M;
Bersanelli, M;
Butler, R C;
Cuttaia, F;
D'Arcangelo, O;
Davis, R;
Franceschet, C;
Galeotta, S;
Gregorio, A;
Hughes, N;
Jukkala, P;
Kettle, D;
Laaninen, M;
Leutenegger, P;
Leonardi, R;
Mandolesi, N;
Maris, M;
Meinhold, P;
Miccolis, M;
Roddis, N;
Sambo, L;
Sandri, M;
Silvestri, R;
Tuovinen, J;
Valenziano, L;
Varis, J;
Villa, F;
Wilkinson, A;
Zonca, A
Submitted: 2010-01-26
This paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst .
This paper describes the impact of the Planck Low Frequency Instrument front
end physical temperature fluctuations on the output signal. The origin of
thermal instabilities in the instrument are discussed, and an analytical model
of their propagation and impact on the receivers signal is described. The
experimental test setup dedicated to evaluate these effects during the
instrument ground calibration is reported together with data analysis methods.
Finally, main results obtained are discussed and compared to the requirements.
[3]
oai:arXiv.org:0903.1354 [pdf] - 22164
The Large APEX Bolometer Camera LABOCA
Siringo, G.;
Kreysa, E.;
Kovacs, A.;
Schuller, F.;
Weiss, A.;
Esch, W.;
Gemuend, H. P.;
Jethava, N.;
Lundershausen, G.;
Colin, A.;
Guesten, R.;
Menten, K. M.;
Beelen, A.;
Bertoldi, F.;
Beeman, J. W.;
Haller, E. E.
Submitted: 2009-03-07
The Large APEX Bolometer Camera, LABOCA, has been commissioned for operation
as a new facility instrument t the Atacama Pathfinder Experiment 12m
submillimeter telescope. This new 295-bolometer total power camera, operating
in the 870 micron atmospheric window, combined with the high efficiency of APEX
and the excellent atmospheric transmission at the site, offers unprecedented
capability in mapping submillimeter continuum emission for a wide range of
astronomical purposes.