Normalized to: Colas, P.
[1]
oai:arXiv.org:1706.06483 [pdf] - 1584925
Performance measurement of HARPO: a Time Projection Chamber as a
gamma-ray telescope and polarimeter
Gros, P.;
Amano, S.;
Attié, D.;
Baron, P.;
Baudin, D.;
Bernard, D.;
Bruel, P.;
Calvet, D.;
Colas, P.;
Daté, S.;
Delbart, A.;
Frotin, M.;
Geerebaert, Y.;
Giebels, B.;
Götz, D.;
Hashimoto, S.;
Horan, D.;
Kotaka, T.;
Louzir, M.;
Magniette, F.;
Minamiyama, Y.;
Miyamoto, S.;
Ohkuma, H.;
Poilleux, P.;
Semeniouk, I.;
Sizun, P.;
Takemoto, A.;
Yamaguchi, M.;
Yonamine, R.;
Wang, S.
Submitted: 2017-06-20, last modified: 2017-08-30
We analyse the performance of a gas time projection chamber (TPC) as a
high-performance gamma-ray telescope and polarimeter in the e$^+$e$^-$ pair
creation regime. We use data collected at a gamma-ray beam of known
polarisation. The TPC provides two orthogonal projections $(x,z)$ and $(y,z)$
of the tracks induced by each conversion in the gas volume. We use a simple
vertex finder in which vertices and pseudo-tracks exiting from them are
identified.
We study the various contributions to the single-photon angular resolution
using Monte Carlo simulations and compare them with the experimental data and
find that they are in excellent agreement. The distribution of the azimutal
angle of pair conversions shows a bias due to the non-cylindrical-symmetric
structure of the detector. This bias would average out for a long duration
exposure on a space mission, but for this pencil-beam characterisation we have
ensured its accurate simulation by a double systematics control scheme, data
taking with the detector rotated at several angles with respect to the beam
polarisation direction and systematics control with a non-polarised beam.
We measure, for the first time, the polarisation asymmetry of a linearly
polarised gamma-ray beam in the low energy pair creation regime. This sub-GeV
energy range is critical for cosmic sources as their spectra are power laws
which fall quickly as a function of increasing energy.
This work could pave the way to extending polarised gamma-ray astronomy
beyond the MeV energy regime.
[2]
oai:arXiv.org:1504.05865 [pdf] - 1579629
First detection of tracks of radon progeny recoils by MIMAC
Riffard, Q.;
Santos, D.;
Bosson, G.;
Bourrion, O.;
Descombes, T.;
Fourel, C.;
Guillaudin, O.;
Muraz, J. -F.;
Colas, P.;
Ferrer-Ribas, E.;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Tao, C.;
Lebreton, L.;
Maire, D.
Submitted: 2015-04-22, last modified: 2017-06-20
The MIMAC experiment is a $\mu$-TPC matrix project for directional dark
matter search. Directional detection is a strategy based on the measurement of
the WIMP flux anisotropy due to the solar system motion with respect to the
dark matter halo. The main purpose of MIMAC project is the measurement of the
energy and the direction of nuclear recoils in 3D produced by elastic
scattering of WIMPs. Since June 2012 a bi-chamber prototype is operating at the
Modane underground laboratory. In this paper, we report the first ionization
energy and 3D track observations of nuclear recoils produced by the radon
progeny. This measurement shows the capability of the MIMAC detector and opens
the possibility to explore the low energy recoil directionality signature.
[3]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
[4]
oai:arXiv.org:1607.08765 [pdf] - 1446365
Directional detection of Dark Matter with the MIcro-tpc MAtrix of
Chambers
Couturier, C.;
Guillaudin, O.;
Naraghi, F.;
Riffard, Q.;
Santos, D.;
Sauzet, N.;
Colas, P.;
Ribas, E. Ferrer;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Tao, C.;
Zhou, N.
Submitted: 2016-07-29
Particles weakly interacting with ordinary matter, with an associated mass of
the order of an atomic nucleus (WIMPs), are plausible candidates for Dark
Matter. The direct detection of an elastic collision of a target nuclei induced
by one of these WIMPs has to be discriminated from the signal produced by the
neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc
MAtrix of Chambers) collaboration has developed an original prototype detector
which combines a large pixelated Micromegas coupled with a fast,
self-triggering, electronics. Aspects of the two-chamber module in operation in
the Modane Underground Laboratory are presented: calibration, characterization
of the $^{222}$Rn progeny. A new test bench combining a MIMAC chamber with the
COMIMAC portable quenching line has been set up to characterize the 3D tracks
of low energy ions in the MIMAC gas mixture: the preliminary results thereof
are presented. Future steps are briefly discussed.
[5]
oai:arXiv.org:1602.01738 [pdf] - 1483260
MIMAC low energy electron-recoil discrimination measured with fast
neutrons
Riffard, Q.;
Santos, D.;
Guillaudin, O.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Descombes, T.;
Muraz, J. -F.;
Lebreton, L.;
Maire, D.;
Colas, P.;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Brunner, J.;
Tao, C.
Submitted: 2016-02-04, last modified: 2016-07-04
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter
detector project. Direct dark matter experiments need a high level of
electron/recoil discrimination to search for nuclear recoils produced by
WIMP-nucleus elastic scattering. In this paper, we proposed an original method
for electron event rejection based on a multivariate analysis applied to
experimental data acquired using monochromatic neutron fields. This analysis
shows that a $10^5$ rejection power is reachable for electron/recoil
discrimination. Moreover, the efficiency was estimated by a Monte-Carlo
simulation showing that a 105 electron rejection power is reached with a
$86.49\pm 0.17$\% nuclear recoil efficiency considering the full energy range
and $94.67\pm0.19$\% considering a 5~keV lower threshold.
[6]
oai:arXiv.org:1606.09417 [pdf] - 1479435
First measurement of polarisation asymmetry of a gamma-ray beam between
1.74 to 74 MeV with the HARPO TPC
Gros, Philippe;
Amano, Sho;
Attié, David;
Bernard, Denis;
Bruel, Philippe;
Calvet, Denis;
Colas, Paul;
Daté, Schin;
Delbart, Alain;
Frotin, Mickael;
Geerebaert, Yannick;
Giebels, Berrie;
Götz, Diego;
Hashimoto, S.;
Horan, Deirdr;
Kotaka, T.;
Louzir, Marc;
Minamiyama, Y.;
Miyamoto, Shuji;
Ohkuma, H.;
Poilleux, Patrick;
Semeniouk, Igor;
Sizun, Patrick;
Takemoto, A.;
Yamaguchi, M.;
Wang, Shaobo
Submitted: 2016-06-30
Current $\gamma$-ray telescopes suffer from a gap in sensitivity in the
energy range between 100keV and 100MeV, and no polarisation measurement has
ever been done on cosmic sources above 1MeV. Past and present e$^+$e$^-$ pair
telescopes are limited at lower energies by the multiple scattering of
electrons in passive tungsten converter plates. This results in low angular
resolution, and, consequently, a drop in sensitivity to point sources below
1GeV. The polarisation information, which is carried by the azimuthal angle of
the conversion plane, is lost for the same reasons.
HARPO (Hermetic ARgon POlarimeter) is an R\&D program to characterise the
operation of a gaseous detector (a Time Projection Chamber or TPC) as a high
angular-resolution and sensitivity telescope and polarimeter for $\gamma$ rays
from cosmic sources. It represents a first step towards a future space
instrument in the MeV-GeV range.
We built and characterised a 30cm cubic demonstrator [SPIE 91441M], and put
it in a polarised $\gamma$-ray beam at the NewSUBARU accelerator in Japan. Data
were taken at photon energies from 1.74MeV to 74MeV, and with different
polarisation configurations.
We describe the experimental setup in beam. We then describe the software we
developed to reconstruct the photon conversion events, with special focus on
low energies. We also describe the thorough simulation of the detector used to
compare results. Finally we will present the performance of the detector as
extracted from this analysis and preliminary measurements of the polarisation
asymmetry.
This beam-test qualification of a gas TPC prototype in a $\gamma$-ray beam
could open the way to high-performance $\gamma$-ray astronomy and polarimetry
in the MeV-GeV energy range in the near future.
[7]
oai:arXiv.org:1603.06817 [pdf] - 1432235
Measurement of 1.7 to 74 MeV polarised gamma rays with the HARPO TPC
Geerebaert, Y.;
Gros, Ph.;
Amano, S.;
Attié, D.;
Bernard, D.;
Bruel, P.;
Calvet, D.;
Colas, P.;
Daté, S.;
Delbart, A.;
Frotin, M.;
Giebels, B.;
Götz, D.;
Hashimoto, S.;
Horan, D.;
Kotaka, T.;
Louzir, M.;
Minamiyama, Y.;
Miyamoto, S.;
Ohkuma, H.;
Poilleux, P.;
Semeniouk, I.;
Sizun, P.;
Takemoto, A.;
Yamaguchi, M.;
Wang, S.
Submitted: 2016-03-22
Current {\gamma}-ray telescopes based on photon conversions to
electron-positron pairs, such as Fermi, use tungsten converters. They suffer of
limited angular resolution at low energies, and their sensitivity drops below 1
GeV. The low multiple scattering in a gaseous detector gives access to higher
angular resolution in the MeV-GeV range, and to the linear polarisation of the
photons through the azimuthal angle of the electron-positron pair.
HARPO is an R&D program to characterise the operation of a TPC (Time
Projection Chamber) as a high angular-resolution and sensitivity telescope and
polarimeter for {\gamma} rays from cosmic sources. It represents a first step
towards a future space instrument. A 30 cm cubic TPC demonstrator was built,
and filled with 2 bar argon-based gas. It was put in a polarised {\gamma}-ray
beam at the NewSUBARU accelerator in Japan in November 2014. Data were taken at
different photon energies from 1.7 MeV to 74 MeV, and with different
polarisation configurations. The electronics setup is described, with an
emphasis on the trigger system. The event reconstruction algorithm is quickly
described, and preliminary measurements of the polarisation of 11 MeVphotons
are shown.
[8]
oai:arXiv.org:1503.03772 [pdf] - 1323356
HARPO: beam characterization of a TPC for gamma-ray polarimetry and high
angular-resolution astronomy in the MeV-GeV range
Wang, Shaobo;
Bernard, Denis;
Bruel, Philippe;
Frotin, Mickael;
Geerebaert, Yannick;
Giebels, Berrie;
Gros, Philippe;
Horan, Deirdre;
Louzir, Marc;
Poilleux, Patrick;
Semeniouk, Igor;
Attié, David;
Calvet, Denis;
Colas, Paul;
Delbart, Alain;
Sizun, Patrick;
Götz, Diego;
Amano, Sho;
Kotaka, Takuya;
Hashimoto, Satoshi;
Minamiyama, Yasuhito;
Takemoto, Akinori;
Yamaguchi, Masashi;
Miyamoto, Shuji;
Daté, Schin;
Ohkuma, Haruo
Submitted: 2015-03-12
A time projection chamber (TPC) can be used to measure the polarization of
gamma rays with excellent angular precision and sensitivity in the MeV-GeV
energy range through the conversion of photons to e+e- pairs. The Hermetic
ARgon POlarimeter (HARPO) prototype was built to demonstrate this concept. It
was recently tested in the polarized photon beam at the NewSUBARU facility in
Japan. We present this data-taking run, which demonstrated the excellent
performance of the HARPO TPC.
[9]
oai:arXiv.org:1406.4830 [pdf] - 857315
HARPO: a TPC as a gamma-ray telescope and polarimeter
Bernard, Denis;
Bruel, Philippe;
Frotin, Mickael;
Geerebaert, Yannick;
Giebels, Berrie;
Gros, Philippe;
Horan, Deirdre;
Louzir, Marc;
Poilleux, Patrick;
Semeniouk, Igor;
Wang, Shaobo;
Anvar, Shebli;
Attié, David;
Colas, Paul;
Delbart, Alain;
Sizun, Patrick;
Götz, Diego
Submitted: 2014-06-18, last modified: 2014-07-28
A gas Time Projection Chamber can be used for gamma-ray astronomy with
excellent angular-precision and sensitivity to faint sources, and for
polarimetry, through the measurement of photon conversion to $e^+e^-$ pairs. We
present the expected performance in simulations and the recent development of a
demonstrator for tests in a polarized photon beam.
[10]
oai:arXiv.org:1109.1675 [pdf] - 1083919
Micromegas detector developments for MIMAC
Ferrer-Ribas, E.;
Attié, D.;
Calvet, D.;
Colas, P.;
Druillole, F.;
Giomataris, Y.;
Iguaz, F. J.;
Mols, J. P.;
Pancin, J.;
Papaevangelou, T.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Santos, D.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-09-08, last modified: 2011-09-12
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a
directional TPC. The recent Micromegas efforts towards building a large size
detector will be described, in particular the characterization measurements of
a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout
plane. Track reconstruction with alpha particles will be shown.
[11]
oai:arXiv.org:1001.2983 [pdf] - 32880
Directional detection of galactic Dark Matter
Mayet, F.;
Billard, J.;
Bernard, G.;
Bosson, G.;
Bourrion, O.;
Grignon, C.;
Guillaudin, O.;
Koumeir, C.;
Richer, J. P.;
Santos, D.;
Colas, P.;
Ferer, E.;
Giomataris, I.;
Allaoua, A.;
Lebreton, L.
Submitted: 2010-01-18
Directional detection of galactic Dark Matter is a promising search strategy
for discriminating geniune WIMP events from background ones. We present
technical progress on gaseous detectors as well as recent phenomenological
studies, allowing the design and construction of competitive experiments.
[12]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[13]
oai:arXiv.org:0909.0654 [pdf] - 901600
A prototype of a directional detector for non-baryonic dark matter
search: MIMAC (Micro-TPC Matrix of Chambers)
Grignon, C.;
Bernard, G.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Koumeir, C.;
Mayet, F.;
Santos, D.;
Colas, P.;
Ferrer, E.;
Giomataris, I.;
Allaoua, A.;
Lebreton, L.
Submitted: 2009-09-03, last modified: 2009-10-30
We have developed a micro-tpc using a pixelized bulk micromegas coupled to
dedicated acquisition electronics as a read-out allowing to reconstruct the
three dimensional track of a few keV recoils. The prototype has been tested
with the Amande facility at the IRSN-Cadarache providing monochromatic
neutrons. The first results concerning discrimination of a few keV electrons
and proton recoils are presented.
[14]
oai:arXiv.org:0905.4800 [pdf] - 24752
Dark matter directional detection with MIMAC
Grignon, C.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Koumeir, C.;
Mayet, F.;
Santos, D.;
Colas, P.;
Ferrer, E.;
Giomataris, I.
Submitted: 2009-05-29
MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for
direct detection of non-baryonic dark matter. Measurement of both track and
ionization energy will allow the electron-recoil discrimination, while access
to the directionnality of the tracks will open a unique way to distinguish a
geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV
electrons are presented as a proof of concept.
[15]
oai:arXiv.org:0905.4654 [pdf] - 24724
Micromegas micro-TPC for direct Dark Matter search with MIMAC
Submitted: 2009-05-28
The MIMAC project is a multi-chamber detector for Dark Matter search, aiming
at measuring both track and ionization with a matrix of micromegas micro-TPC
filled with He3 and CF4. Recent experimental results on the first measurements
of the Helium quenching factor at low energy (1 keV recoil) are presented,
together with the first simulation of the track reconstruction. Recontruction
of track of alpha from Radon impurities is shown as a first proof of concept.
[16]
oai:arXiv.org:0904.1667 [pdf] - 23251
Low energy measurements with Helium Micromegas micro-TPC
Submitted: 2009-04-10
The measurement of the ionization produced by particles in a medium presents
a great interest in several fields from metrology to particule physics and
cosmology. The ionization quenching factor is defined as the fraction of energy
released by ionisation by a recoil in a medium compared with its kinetic
energy. At low energy, in the range of a few keV, the ionization falls rapidly
and systematic measurement are needed. We have developped an experimental setup
devoted to the measurement of low energy (keV) ionization quenching factor for
the MIMAC project. The ionization produced in the gas has been measured with a
Micromegas detector filled with Helium gas mixture.
[17]
oai:arXiv.org:0810.1137 [pdf] - 17161
Ionization Quenching Factor Measurement of Helium 4
Submitted: 2008-10-07
The ionization quenching factor (IQF) is defined as the fraction of energy
released by a recoil in a medium through ionization compared with its total
kinetic energy. At low energies, in the range of a few keV, the ionization
produced in a medium falls rapidly and systematic measurements are needed. We
report measurements carried out at such low energies as a function of the
pressure in He4 at 350, 700, 1000 and 1300 mbar. In order to produce a nucleus
moving with a controlled energy in the detection volume, we have developed an
Electron Cyclotron Resonance Ion Source (ECRIS) coupled to an ionization
chamber by a differential pumping. The quenching factor of He4 has been
measured for the first time down to 1 keV recoil energies. An important
deviation with respect to the phenomenological calculations has been found
allowing an estimation of the scintillation produced in He4 as a function of
pressure. The variation of the IQF as a function of the percentage of
isobutane, used as quencher, is also presented.