Normalized to: Coakley, K.
[1]
oai:arXiv.org:1408.1914 [pdf] - 1216195
Improving Photoelectron Counting and Particle Identification in
Scintillation Detectors with Bayesian Techniques
Akashi-Ronquest, M.;
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bodmer, M.;
Boulay, M. G.;
Broerman, B.;
Buck, B.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chen, Y.;
Cleveland, B.;
Coakley, K.;
Dering, K.;
Duncan, F. A.;
Formaggio, J. A.;
Gagnon, R.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grace, E.;
Guerrero, N.;
Guiseppe, V.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Henning, R.;
Hime, A.;
Hofgartner, J.;
Jaditz, S.;
Jillings, C. J.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Kuzniak, M.;
LaTorre, A.;
Lawson, I.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Linden, S.;
McFarlane, K.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mathew, R.;
McDonald, A. B.;
Mei, D. -M.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J. A.;
Noble, T.;
O'Dwyer, E.;
Olsen, K.;
Gann, G. D. Orebi;
Ouellet, C.;
Palladino, K.;
Pasuthip, P.;
Perumpilly, G.;
Pollmann, T.;
Rau, P.;
Retiere, F.;
Rielage, K.;
Schnee, R.;
Seibert, S.;
Skensved, P.;
Sonley, T.;
Vazquez-Jauregui, E.;
Veloce, L.;
Walding, J.;
Wang, B.;
Wang, J.;
Ward, M.;
Zhang, C.
Submitted: 2014-08-08, last modified: 2014-12-12
Many current and future dark matter and neutrino detectors are designed to
measure scintillation light with a large array of photomultiplier tubes (PMTs).
The energy resolution and particle identification capabilities of these
detectors depend in part on the ability to accurately identify individual
photoelectrons in PMT waveforms despite large variability in pulse amplitudes
and pulse pileup. We describe a Bayesian technique that can identify the times
of individual photoelectrons in a sampled PMT waveform without deconvolution,
even when pileup is present. To demonstrate the technique, we apply it to the
general problem of particle identification in single-phase liquid argon dark
matter detectors. Using the output of the Bayesian photoelectron counting
algorithm described in this paper, we construct several test statistics for
rejection of backgrounds for dark matter searches in argon. Compared to simpler
methods based on either observed charge or peak finding, the photoelectron
counting technique improves both energy resolution and particle identification
of low energy events in calibration data from the DEAP-1 detector and
simulation of the larger MiniCLEAN dark matter detector.
[2]
oai:arXiv.org:1403.4842 [pdf] - 799232
Update on the MiniCLEAN Dark Matter Experiment
Rielage, K.;
Akashi-Ronquest, M.;
Bodmer, M.;
Bourque, R.;
Buck, B.;
Butcher, A.;
Caldwell, T.;
Chen, Y.;
Coakley, K.;
Flores, E.;
Formaggio, J. A.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Grace, E.;
Griego, J.;
Guerrero, N.;
Guiseppe, V.;
Henning, R.;
Hime, A.;
Jaditz, S.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Latorre, A.;
Lawson, I.;
Linden, S.;
Lopez, F.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mei, D. -M.;
Monroe, J.;
Nikkel, J. A.;
Oertel, J.;
Gann, G. D. Orebi;
Palladino, K.;
Perumpilly, G.;
Rodriguez, L.;
Schnee, R.;
Seibert, S.;
Walding, J.;
Wang, B.;
Wang, J.;
Zhang, C.
Submitted: 2014-03-19
The direct search for dark matter is entering a period of increased
sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One
such technology that is being examined is a scintillation only noble liquid
experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to
detect nuclear recoils from WIMP dark matter and serves as a demonstration for
a future detector of order 50 to 100 tonnes. The liquid cryogen is
interchangeable between argon and neon to study the A$^{2}$ dependence of the
potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular
design with spherical geometry to maximize the light yield using cold
photomultiplier tubes in a single-phase detector. Pulse shape discrimination
techniques are used to separate nuclear recoil signals from electron recoil
backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate
the effective reach of the pulse shape discrimination capability. Assembly of
the experiment is underway at SNOLAB and an update on the project is given.
[3]
oai:arXiv.org:1111.3260 [pdf] - 548322
Scintillation yield and time dependence from electronic and nuclear
recoils in liquid neon
Submitted: 2011-11-14, last modified: 2012-08-13
We have performed measurements of scintillation light in liquid neon,
observing a signal yield in our detector as high as (3.5 $\pm$ 0.4)
photoelectrons/keV. We measure pulse shape discrimination efficiency between
electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear
recoil energy. We also measure the \leff\, parameter in liquid neon between 30
and 370 keV nuclear recoil energy, observing an average \leff$=0.24$ above 50
keV. We observe a dependence of the scintillation time distribution and signal
yield on the pressure and temperature of the liquid neon.
[4]
oai:arXiv.org:astro-ph/0402007 [pdf] - 62521
Neutrino Detection With CLEAN
Submitted: 2004-01-31, last modified: 2004-02-08
This article describes CLEAN, an approach to the detection of low-energy
solar neutrinos and neutrinos released from supernovae. The CLEAN concept is
based on the detection of elastic scattering events (neutrino-electron
scattering and neutrino-nuclear scattering) in liquified noble gases such as
liquid helium, liquid neon, and liquid xenon, all of which scintillate brightly
in the ultraviolet. Key to the CLEAN technique is the use of a thin film of
wavelength-shifting fluor to convert the ultraviolet scintillation light to the
visible. This allows the same liquid to be used as both a passive shielding
medium and an active self-shielding detector, allowing lower intrinsic
radioactive backgrounds at low energies. Liquid neon is a particularly
promising medium for CLEAN. Because liquid neon has a high scintillation yield,
has no long-lived radioactive isotopes, and can be easily purified by use of
cold traps, it is an ideal medium for the detection of rare nuclear events. In
addition, neon is inexpensive, dense, and transparent to its own scintillation
light, making it practical for use in a large self-shielding apparatus. Monte
Carlo simulations of gamma ray backgrounds have been performed assuming liquid
neon as both shielding and detection medium. Gamma ray events occur with high
probability in the outer parts of the detector. In contrast, neutrino
scattering events occur uniformly throughout the detector. We discriminate
background gamma ray events from events of interest based on a spatial Maximum
Likelihood method estimate of event location. Background estimates for CLEAN
are presented, as well as an evaluation of the sensitivity of the detector for
$p-p$ neutrinos. Given these simulations, the physics potential of the CLEAN
approach is evaluated.
[5]
oai:arXiv.org:physics/0309033 [pdf] - 119023
Spatial methods for event reconstruction in CLEAN
Submitted: 2003-09-04
In CLEAN (Cryogenic Low Energy Astrophysics with Noble gases), a proposed
neutrino and dark matter detector, background discrimination is possible if one
can determine the location of an ionizing radiation event with high accuracy.
We simulate ionizing radiation events that produce multiple scintillation
photons within a spherical detection volume filled with liquid neon. We
estimate the radial location of a particular ionizing radiation event based on
the observed count data corresponding to that event. The count data are
collected by detectors mounted at the spherical boundary of the detection
volume. We neglect absorption, but account for Rayleigh scattering. To account
for wavelength-shifting of the scintillation light, we assume that photons are
absorbed and re-emitted at the detectors. Here, we develop spatial Maximum
Likelihood methods for event reconstruction, and study their performance in
computer simulation experiments. We also study a method based on the centroid
of the observed count data. We calibrate our estimates based on training data.
[6]
oai:arXiv.org:astro-ph/0302071 [pdf] - 54698
Supernova Observation Via Neutrino-Nucleus Elastic Scattering in the
CLEAN Detector
Submitted: 2003-02-04
Development of large mass detectors for low-energy neutrinos and dark matter
may allow supernova detection via neutrino-nucleus elastic scattering. An
elastic-scattering detector could observe a few, or more, events per ton for a
galactic supernova at 10 kpc ($3.1 \times 10^{20}$ m). This large yield, a
factor of at least 20 greater than that for existing light-water detectors,
arises because of the very large coherent cross section and the sensitivity to
all flavors of neutrinos and antineutrinos. An elastic scattering detector can
provide important information on the flux and spectrum of $\nu_\mu$ and
$\nu_\tau$ from supernovae. We consider many detectors and a range of target
materials from $^4$He to $^{208}$Pb. Monte Carlo simulations of low-energy
backgrounds are presented for the liquid-neon-based Cryogenic Low Energy
Astrophysics with Noble gases (CLEAN) detector. The simulated background is
much smaller than the expected signal from a galactic supernova.