Normalized to: Clerc, L.
[1]
oai:arXiv.org:1407.2545 [pdf] - 1215555
The ArT\'eMiS wide-field submillimeter camera: preliminary on-sky
performances at 350 microns
Reveret, Vincent;
André, Philippe;
Pennec, Jean Le;
Talvard, Michel;
Agnèse, Patrick;
Arnaud, Agnès;
Clerc, Laurent;
de Breuck, Carlos;
Cigna, Jean-Charles;
Delisle, Cyrille;
Doumayrou, Eric;
Duband, Lionel;
Dubreuil, Didier;
Dumaye, Luc;
Ercolani, Eric;
Gallais, Pascal;
Groult, Elodie;
Jourdan, Thierry;
Leriche, Bernadette;
Maffei, Bruno;
Lortholary, Michel;
Martignac, Jérôme;
Rabaud, Wilfried;
Relland, Johan;
Rodriguez, Louis;
Vandeneynde, Aurélie;
Visticot, François
Submitted: 2014-07-09
ArTeMiS is a wide-field submillimeter camera operating at three wavelengths
simultaneously (200, 350 and 450 microns). A preliminary version of the
instrument equipped with the 350 microns focal plane, has been successfully
installed and tested on APEX telescope in Chile during the 2013 and 2014
austral winters. This instrument is developed by CEA (Saclay and Grenoble,
France), IAS (France) and University of Manchester (UK) in collaboration with
ESO. We introduce the mechanical and optical design, as well as the cryogenics
and electronics of the ArTeMiS camera. ArTeMiS detectors are similar to the
ones developed for the Herschel PACS photometer but they are adapted to the
high optical load encountered at APEX site. Ultimately, ArTeMiS will contain 4
sub-arrays at 200 microns and 2x8 sub-arrays at 350 and 450 microns. We show
preliminary lab measurements like the responsivity of the instrument to hot and
cold loads illumination and NEP calculation. Details on the on-sky
commissioning runs made in 2013 and 2014 at APEX are shown. We used planets
(Mars, Saturn, Uranus) to determine the flat-field and to get the flux
calibration. A pointing model was established in the first days of the runs.
The average relative pointing accuracy is 3 arcsec. The beam at 350 microns has
been estimated to be 8.5 arcsec, which is in good agreement with the beam of
the 12 m APEX dish. Several observing modes have been tested, like On-The-Fly
for beam-maps or large maps, spirals or raster of spirals for compact sources.
With this preliminary version of ArTeMiS, we concluded that the mapping speed
is already more than 5 times better than the previous 350 microns instrument at
APEX. The median NEFD at 350 microns is 600 mJy.s1/2, with best values at 300
mJy.s1/2. The complete instrument with 5760 pixels and optimized settings will
be installed during the first half of 2015.
[2]
oai:arXiv.org:1005.5123 [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.;
Abergel, A.;
Abreu, A.;
Ade, P. A. R.;
André, P.;
Augueres, J. -L.;
Babbedge, T.;
Bae, Y.;
Baillie, T.;
Baluteau, J. -P.;
Barlow, M. J.;
Bendo, G.;
Benielli, D.;
Bock, J. J.;
Bonhomme, P.;
Brisbin, D.;
Brockley-Blatt, C.;
Caldwell, M.;
Cara, C.;
Castro-Rodriguez, N.;
Cerulli, R.;
Chanial, P.;
Chen, S.;
Clark, E.;
Clements, D. L.;
Clerc, L.;
Coker, J.;
Communal, D.;
Conversi, L.;
Cox, P.;
Crumb, D.;
Cunningham, C.;
Daly, F.;
Davis, G. R.;
De Antoni, P.;
Delderfield, J.;
Devin, N.;
Di Giorgio, A.;
Didschuns, I.;
Dohlen, K.;
Donati, M.;
Dowell, A.;
Dowell, C. D.;
Duband, L.;
Dumaye, L.;
Emery, R. J.;
Ferlet, M.;
Ferrand, D.;
Fontignie, J.;
Fox, M.;
Franceschini, A.;
Frerking, M.;
Fulton, T.;
Garcia, J.;
Gastaud, R.;
Gear, W. K.;
Glenn, J.;
Goizel, A.;
Griffin, D. K.;
Grundy, T.;
Guest, S.;
Guillemet, L.;
Hargrave, P. C.;
Harwit, M.;
Hastings, P.;
Hatziminaoglou, E.;
Herman, M.;
Hinde, B.;
Hristov, V.;
Huang, M.;
Imhof, P.;
Isaak, K. J.;
Israelsson, U.;
Ivison, R. J.;
Jennings, D.;
Kiernan, B.;
King, K. J.;
Lange, A. E.;
Latter, W.;
Laurent, G.;
Laurent, P.;
Leeks, S. J.;
Lellouch, E.;
Levenson, L.;
Li, B.;
Li, J.;
Lilienthal, J.;
Lim, T.;
Liu, J.;
Lu, N.;
Madden, S.;
Mainetti, G.;
Marliani, P.;
McKay, D.;
Mercier, K.;
Molinari, S.;
Morris, H.;
Moseley, H.;
Mulder, J.;
Mur, M.;
Naylor, D. A.;
Nguyen, H.;
O'Halloran, B.;
Oliver, S.;
Olofsson, G.;
Olofsson, H. -G.;
Orfei, R.;
Page, M. J.;
Pain, I.;
Panuzzo, P.;
Papageorgiou, A.;
Parks, G.;
Parr-Burman, P.;
Pearce, A.;
Pearson, C.;
Pérez-Fournon, I.;
Pinsard, F.;
Pisano, G.;
Podosek, J.;
Pohlen, M.;
Polehampton, E. T.;
Pouliquen, D.;
Rigopoulou, D.;
Rizzo, D.;
Roseboom, I. G.;
Roussel, H.;
Rowan-Robinson, M.;
Rownd, B.;
Saraceno, P.;
Sauvage, M.;
Savage, R.;
Savini, G.;
Sawyer, E.;
Scharmberg, C.;
Schmitt, D.;
Schneider, N.;
Schulz, B.;
Schwartz, A.;
Shafer, R.;
Shupe, D. L.;
Sibthorpe, B.;
Sidher, S.;
Smith, A.;
Smith, A. J.;
Smith, D.;
Spencer, L.;
Stobie, B.;
Sudiwala, R.;
Sukhatme, K.;
Surace, C.;
Stevens, J. A.;
Swinyard, B. M.;
Trichas, M.;
Tourette, T.;
Triou, H.;
Tseng, S.;
Tucker, C.;
Turner, A.;
Vaccari, M.;
Valtchanov, I.;
Vigroux, L.;
Virique, E.;
Voellmer, G.;
Walker, H.;
Ward, R.;
Waskett, T.;
Weilert, M.;
Wesson, R.;
White, G. J.;
Whitehouse, N.;
Wilson, C. D.;
Winter, B.;
Woodcraft, A. L.;
Wright, G. S.;
Xu, C. K.;
Zavagno, A.;
Zemcov, M.;
Zhang, L.;
Zonca, E.
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space
Observatory`s submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 microns, and an imaging
Fourier Transform Spectrometer (FTS) which covers simultaneously its whole
operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are
arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a
field of view of 4' x 8', observed simultaneously in the three spectral bands.
Its main operating mode is scan-mapping, whereby the field of view is scanned
across the sky to achieve full spatial sampling and to cover large areas if
desired. The spectrometer has an approximately circular field of view with a
diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25
GHz by changing the stroke length of the FTS scan mirror. Its main operating
mode involves a fixed telescope pointing with multiple scans of the FTS mirror
to acquire spectral data. For extended source measurements, multiple position
offsets are implemented by means of an internal beam steering mirror to achieve
the desired spatial sampling and by rastering of the telescope pointing to map
areas larger than the field of view. The SPIRE instrument consists of a cold
focal plane unit located inside the Herschel cryostat and warm electronics
units, located on the spacecraft Service Module, for instrument control and
data handling. Science data are transmitted to Earth with no on-board data
compression, and processed by automatic pipelines to produce calibrated science
products. The in-flight performance of the instrument matches or exceeds
predictions based on pre-launch testing and modelling: the photometer
sensitivity is comparable to or slightly better than estimated pre-launch, and
the spectrometer sensitivity is also better by a factor of 1.5-2.