Normalized to: Civitani, M.
[1]
oai:arXiv.org:1908.08586 [pdf] - 1948262
PHEMTO : Polarimetric High Energy Modular Telescope Observatory
Laurent, P.;
Acero, F.;
Beckmann, V.;
Brandt, S.;
Cangemi, F.;
Civitani, M.;
Clavel, M.;
Coleiro, A.;
Curado, R.;
Ferrando, P.;
Ferrigno, C.;
Frontera, F.;
Gastaldello, F.;
Götz, D.;
Gouiffès, C.;
Grinberg, V.;
Hanlon, L.;
Hartmann, D.;
Maggi, P.;
Marin, F.;
Meuris, A.;
Okajima, T.;
Pareschi, G.;
Pratt, G. W.;
Rea, N.;
Rodriguez, J.;
Rossetti, M.;
Spiga, D.;
Virgilli, E.;
Zane, S.
Submitted: 2019-08-22
With the opening of the X and gamma--ray windows in the sixties, thanks to to
sounding rockets and satellite-borne instruments, extremely energetic and
violent phenomena were discovered and subsequently found to be ubiquitous in
the Universe. Observations in the high energy domain are fundamental for
understanding how matter is organized and behaves around black holes;
unravelling how these extreme objects influence their environments on a very
large scale; and finding the still elusive obscured massive objects in the
centre of galaxies. Other major problems in contemporary astrophysics, such as
the understanding of acceleration processes at shocks of all sizes (those of
pulsar wind nebulae, supernova remnants, but also at larger scales those of
Active Galactic Nuclei radio lobes) in relation to the origin of cosmic-rays,
or the definitive characterization of the debated non-thermal X-ray energy
content of clusters of galaxies, also requires observations at very high
energies. An observatory type medium mission operating from around 1 keV to
about 600 keV can provide direct insights into these major questions. The
essential characteristics will be coverage of the full energy range by
telescopes featuring a large throughput and arc-second resolution optics,
coupled to a compact focal plane assembly, with excellent imaging resolution
and spectroscopy. In addition, the mission will provide unique polarimetry
measurements in the hard X-ray domain, an important new diagnostic tool at
energies for which the non-thermal processes dominate. The Polarimetric
High-Energy Modular Telescope Observatory (PHEMTO) is designed to have
performance several orders of magnitude better than the present hard X-ray
instruments. This gives to PHEMTO the improvements in scientific performance
needed for a mission in the 2050 era.
[2]
oai:arXiv.org:1906.05648 [pdf] - 2007228
Thin glass shells for active optics for future space telescopes
Submitted: 2019-06-13
We present a method for the manufacturing of thin shells of glass, which
appears promising for the development of active optics for future space
telescopes. The method exploits the synergy of different mature technologies,
while leveraging the commercial availability of large, high-quality sheets of
glass, with thickness up to few millimeters. The first step of the method
foresees the pre-shaping of flat substrates of glass by replicating the
accurate shape of a mold via hot slumping technology. The replication concept
is advantageous for making large optics composed of many identical or similar
segments. After the hot slumping, the shape error residual on the optical
surface is addressed by applying a deterministic sub-aperture technology as
computer-controlled bonnet polishing and/or ion beam figuring. Here we focus on
the bonnet polishing case, during which the thin, deformable substrate of glass
is temporary stiffened by a removable holder. In this paper, we report on the
results so far achieved on a 130 mm glass shell case study.
[3]
oai:arXiv.org:1812.04020 [pdf] - 1795995
The enhanced X-ray Timing and Polarimetry mission - eXTP
Zhang, ShuangNan;
Santangelo, Andrea;
Feroci, Marco;
Xu, YuPeng;
Lu, FangJun;
Chen, Yong;
Feng, Hua;
Zhang, Shu;
Brandt, Søren;
Hernanz, Margarita;
Baldini, Luca;
Bozzo, Enrico;
Campana, Riccardo;
De Rosa, Alessandra;
Dong, YongWei;
Evangelista, Yuri;
Karas, Vladimir;
Meidinger, Norbert;
Meuris, Aline;
Nandra, Kirpal;
Pan, Teng;
Pareschi, Giovanni;
Orleanski, Piotr;
Huang, QiuShi;
Schanne, Stephane;
Sironi, Giorgia;
Spiga, Daniele;
Svoboda, Jiri;
Tagliaferri, Gianpiero;
Tenzer, Christoph;
Vacchi, Andrea;
Zane, Silvia;
Walton, Dave;
Wang, ZhanShan;
Winter, Berend;
Wu, Xin;
Zand, Jean J. M. in 't;
Ahangarianabhari, Mahdi;
Ambrosi, Giovanni;
Ambrosino, Filippo;
Barbera, Marco;
Basso, Stefano;
Bayer, Jörg;
Bellazzini, Ronaldo;
Bellutti, Pierluigi;
Bertucci, Bruna;
Bertuccio, Giuseppe;
Borghi, Giacomo;
Cao, XueLei;
Cadoux, Franck;
Campana, Riccardo;
Ceraudo, Francesco;
Chen, TianXiang;
Chen, YuPeng;
Chevenez, Jerome;
Civitani, Marta;
Cui, Wei;
Cui, WeiWei;
Dauser, Thomas;
Del Monte, Ettore;
Di Cosimo, Sergio;
Diebold, Sebastian;
Doroshenko, Victor;
Dovciak, Michal;
Du, YuanYuan;
Ducci, Lorenzo;
Fan, QingMei;
Favre, Yannick;
Fuschino, Fabio;
Gálvez, José Luis;
Gao, Min;
Ge, MingYu;
Gevin, Olivier;
Grassi, Marco;
Gu, QuanYing;
Gu, YuDong;
Han, DaWei;
Hong, Bin;
Hu, Wei;
Ji, Long;
Jia, ShuMei;
Jiang, WeiChun;
Kennedy, Thomas;
Kreykenbohm, Ingo;
Kuvvetli, Irfan;
Labanti, Claudio;
Latronico, Luca;
Li, Gang;
Li, MaoShun;
Li, Xian;
Li, Wei;
Li, ZhengWei;
Limousin, Olivier;
Liu, HongWei;
Liu, XiaoJing;
Lu, Bo;
Luo, Tao;
Macera, Daniele;
Malcovati, Piero;
Martindale, Adrian;
Michalska, Malgorzata;
Meng, Bin;
Minuti, Massimo;
Morbidini, Alfredo;
Muleri, Fabio;
Paltani, Stephane;
Perinati, Emanuele;
Picciotto, Antonino;
Piemonte, Claudio;
Qu, JinLu;
Rachevski, Alexandre;
Rashevskaya, Irina;
Rodriguez, Jerome;
Schanz, Thomas;
Shen, ZhengXiang;
Sheng, LiZhi;
Song, JiangBo;
Song, LiMing;
Sgro, Carmelo;
Sun, Liang;
Tan, Ying;
Uttley, Phil;
Wang, Juan;
Wang, LangPing;
Wang, YuSa;
Watts, Anna L.;
Wen, XiangYang;
Wilms, Jörn;
Xiong, ShaoLin;
Yang, JiaWei;
Yang, Sheng;
Yang, YanJi;
Yu, Nian;
Zhang, WenDa;
Zampa, Gianluigi;
Zampa, Nicola;
Zdziarski, Andrzej A.;
Zhang, AiMei;
Zhang, ChengMo;
Zhang, Fan;
Zhang, Long;
Zhang, Tong;
Zhang, Yi;
Zhang, XiaoLi;
Zhang, ZiLiang;
Zhao, BaoSheng;
Zheng, ShiJie;
Zhou, YuPeng;
Zorzi, Nicola;
Zwart, J. Frans
Submitted: 2018-12-10
In this paper we present the enhanced X-ray Timing and Polarimetry mission -
eXTP. eXTP is a space science mission designed to study fundamental physics
under extreme conditions of density, gravity and magnetism. The mission aims at
determining the equation of state of matter at supra-nuclear density, measuring
effects of QED, and understanding the dynamics of matter in strong-field
gravity. In addition to investigating fundamental physics, eXTP will be a very
powerful observatory for astrophysics that will provide observations of
unprecedented quality on a variety of galactic and extragalactic objects. In
particular, its wide field monitoring capabilities will be highly instrumental
to detect the electro-magnetic counterparts of gravitational wave sources. The
paper provides a detailed description of: (1) the technological and technical
aspects, and the expected performance of the instruments of the scientific
payload; (2) the elements and functions of the mission, from the spacecraft to
the ground segment.
[4]
oai:arXiv.org:1610.00272 [pdf] - 1490021
Manufacturing and testing a thin glass mirror shell with piezoelectric
active control
Spiga, D.;
Barbera, M.;
Collura, A.;
Basso, S.;
Candia, R.;
Civitani, M.;
Di Bella, M.;
Di Cicca, G.;
Cicero, U. Lo;
Lullo, G.;
Pelliciari, C.;
Riva, M.;
Salmaso, B.;
Sciortino, L.;
Varisco, S.
Submitted: 2016-10-02
Optics for future X-ray telescopes will be characterized by very large
aperture and focal length, and will be made of lightweight materials like glass
or silicon in order to keep the total mass within acceptable limits. Optical
modules based on thin slumped glass foils are being developed at various
institutes, aiming at improving the angular resolution to a few arcsec HEW.
Thin mirrors are prone to deform, so they require a careful integration to
avoid deformations and even correct forming errors. On the other hand, this
offers the opportunity to actively correct the residual deformation: a viable
possibility to improve the mirror figure is the application of piezoelectric
actuators onto the non-optical side of the mirrors, and several groups are
already at work on this approach. The concept we are developing consists of
actively integrating thin glass foils with piezoelectric patches, fed by
voltages driven by the feedback provided by X-rays. The actuators are
commercial components, while the tension signals are carried by a printed
circuit obtained by photolithography, and the driving electronic is a
multi-channel low power consumption voltage supply developed in-house. Finally,
the shape detection and the consequent voltage signal to be provided to the
piezoelectric array are determined in X-rays, in intra-focal setup at the XACT
facility at INAF/OAPA. In this work, we describe the manufacturing steps to
obtain a first active mirror prototype and the very first test performed in
X-rays.
[5]
oai:arXiv.org:1607.08823 [pdf] - 2064188
eXTP -- enhanced X-ray Timing and Polarimetry Mission
Zhang, S. N.;
Feroci, M.;
Santangelo, A.;
Dong, Y. W.;
Feng, H.;
Lu, F. J.;
Nandra, K.;
Wang, Z. S.;
Zhang, S.;
Bozzo, E.;
Brandt, S.;
De Rosa, A.;
Gou, L. J.;
Hernanz, M.;
van der Klis, M.;
Li, X. D.;
Liu, Y.;
Orleanski, P.;
Pareschi, G.;
Pohl, M.;
Poutanen, J.;
Qu, J. L.;
Schanne, S.;
Stella, L.;
Uttley, P.;
Watts, A.;
Xu, R. X.;
Yu, W. F.;
Zand, J. J. M. in 't;
Zane, S.;
Alvarez, L.;
Amati, L.;
Baldini, L.;
Bambi, C.;
Basso, S.;
Bhattacharyya, S.;
Bellazzini, R.;
Belloni, T.;
Bellutti, P.;
Bianchi, S.;
Brez, A.;
Bursa, M.;
Burwitz, V.;
Budtz-Jorgensen, C.;
Caiazzo, I.;
Campana, R.;
Cao, X. L.;
Casella, P.;
Chen, C. Y.;
Chen, L.;
Chen, T. X.;
Chen, Y.;
Chen, Y.;
Chen, Y. P.;
Civitani, M.;
Zelati, F. Coti;
Cui, W.;
Cui, W. W.;
Dai, Z. G.;
Del Monte, E.;
De Martino, D.;
Di Cosimo, S.;
Diebold, S.;
Dovciak, M.;
Donnarumma, I.;
Doroshenko, V.;
Esposito, P.;
Evangelista, Y.;
Favre, Y.;
Friedrich, P.;
Fuschino, F.;
Galvez, J. L.;
Gao, Z. L.;
Ge, M. Y.;
Gevin, O.;
Goetz, D.;
Han, D. W.;
Heyl, J.;
Horak, J.;
Hu, W.;
Huang, F.;
Huang, Q. S.;
Hudec, R.;
Huppenkothen, D.;
Israel, G. L.;
Ingram, A.;
Karas, V.;
Karelin, D.;
Jenke, P. A.;
Ji, L.;
Kennedy, T.;
Korpela, S.;
Kunneriath, D.;
Labanti, C.;
Li, G.;
Li, X.;
Li, Z. S.;
Liang, E. W.;
Limousin, O.;
Lin, L.;
Ling, Z. X.;
Liu, H. B.;
Liu, H. W.;
Liu, Z.;
Lu, B.;
Lund, N.;
Lai, D.;
Luo, B.;
Luo, T.;
Ma, B.;
Mahmoodifar, S.;
Marisaldi, M.;
Martindale, A.;
Meidinger, N.;
Men, Y. P.;
Michalska, M.;
Mignani, R.;
Minuti, M.;
Motta, S.;
Muleri, F.;
Neilsen, J.;
Orlandini, M.;
Pan, A T.;
Patruno, A.;
Perinati, E.;
Picciotto, A.;
Piemonte, C.;
Pinchera, M.;
Rachevski, A.;
Rapisarda, M.;
Rea, N.;
Rossi, E. M. R.;
Rubini, A.;
Sala, G.;
Shu, X. W.;
Sgro, C.;
Shen, Z. X.;
Soffitta, P.;
Song, L. M.;
Spandre, G.;
Stratta, G.;
Strohmayer, T. E.;
Sun, L.;
Svoboda, J.;
Tagliaferri, G.;
Tenzer, C.;
Tong, H.;
Taverna, R.;
Torok, G.;
Turolla, R.;
Vacchi, A.;
Wang, J.;
Wang, J. X.;
Walton, D.;
Wang, K.;
Wang, J. F.;
Wang, R. J.;
Wang, Y. F.;
Weng, S. S.;
Wilms, J.;
Winter, B.;
Wu, X.;
Wu, X. F.;
Xiong, S. L.;
Xu, Y. P.;
Xue, Y. Q.;
Yan, Z.;
Yang, S.;
Yang, X.;
Yang, Y. J.;
Yuan, F.;
Yuan, W. M.;
Yuan, Y. F.;
Zampa, G.;
Zampa, N.;
Zdziarski, A.;
Zhang, C.;
Zhang, C. L.;
Zhang, L.;
Zhang, X.;
Zhang, Z.;
Zhang, W. D.;
Zheng, S. J.;
Zhou, P.;
Zhou, X. L.
Submitted: 2016-07-29
eXTP is a science mission designed to study the state of matter under extreme
conditions of density, gravity and magnetism. Primary targets include isolated
and binary neutron stars, strong magnetic field systems like magnetars, and
stellar-mass and supermassive black holes. The mission carries a unique and
unprecedented suite of state-of-the-art scientific instruments enabling for the
first time ever the simultaneous spectral-timing-polarimetry studies of cosmic
sources in the energy range from 0.5-30 keV (and beyond). Key elements of the
payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics
for a total effective area of about 0.9 m^2 and 0.6 m^2 at 2 keV and 6 keV
respectively, equipped with Silicon Drift Detectors offering <180 eV spectral
resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon
Drift Detectors, for a total effective area of about 3.4 m^2, between 6 and 10
keV, and spectral resolution <250 eV; the Polarimetry Focusing Array (PFA) - a
set of 2 X-ray telescope, for a total effective area of 250 cm^2 at 2 keV,
equipped with imaging gas pixel photoelectric polarimeters; the Wide Field
Monitor (WFM) - a set of 3 coded mask wide field units, equipped with
position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90
degrees FoV. The eXTP international consortium includes mostly major
institutions of the Chinese Academy of Sciences and Universities in China, as
well as major institutions in several European countries and the United States.
The predecessor of eXTP, the XTP mission concept, has been selected and funded
as one of the so-called background missions in the Strategic Priority Space
Science Program of the Chinese Academy of Sciences since 2011. The strong
European participation has significantly enhanced the scientific capabilities
of eXTP. The planned launch date of the mission is earlier than 2025.
[6]
oai:arXiv.org:1510.00910 [pdf] - 1287738
Active shape correction of a thin glass/plastic X-ray mirror
Spiga, D.;
Barbera, M.;
Basso, S.;
Civitani, M.;
Collura, A.;
Dell'Agostino, S.;
Cicero, U. Lo;
Lullo, G.;
Pelliciari, C.;
Riva, M.;
Salmaso, B.;
Sciortino, L.
Submitted: 2015-10-04
Optics for future X-ray telescopes will be characterized by very large
aperture and focal length, and will be made of lightweight materials like glass
or plastic in order to keep the total mass within acceptable limits. Optics
based on thin slumped glass foils are currently in use in the NuSTAR telescope
and are being developed at various institutes like INAF/OAB, aiming at
improving the angular resolution to a few arcsec HEW. Another possibility would
be the use of thin plastic foils, being developed at SAO and the Palermo
University. Even if relevant progresses in the achieved angular resolution were
recently made, a viable possibility to further improve the mirror figure would
be the application of piezoelectric actuators onto the non-optical side of the
mirrors. In fact, thin mirrors are prone to deform, so they require a careful
integration to avoid deformations and even correct forming errors. This however
offers the possibility to actively correct the residual deformation. Even if
other groups are already at work on this idea, we are pursuing the concept of
active integration of thin glass or plastic foils with piezoelectric patches,
fed by voltages driven by the feedback provided by X-rays, in intra-focal setup
at the XACT facility at INAF/OAPA. In this work, we show the preliminary
simulations and the first steps taken in this project.
[7]
oai:arXiv.org:1509.02298 [pdf] - 1273356
Profile reconstruction of grazing-incidence X-ray mirrors from
intra-focal X-ray full imaging
Spiga, D.;
Basso, S.;
Bavdaz, M.;
Burwitz, V.;
Civitani, M.;
Citterio, O.;
Ghigo, M.;
Hartner, G.;
Menz, B.;
Pareschi, G.;
Proserpio, L.;
Salmaso, B.;
Tagliaferri, G.;
Wille, E.
Submitted: 2015-09-08
The optics of a number of future X-ray telescopes will have very long focal
lengths (10 - 20 m), and will consist of a number of nested/stacked thin,
grazing-incidence mirrors. The optical quality characterization of a real
mirror can be obtained via profile metrology, and the Point Spread Function of
the mirror can be derived via one of the standard computation methods. However,
in practical cases it can be difficult to access the optical surfaces of
densely stacked mirror shells, after they have been assembled, using the
widespread metrological tools. For this reason, the assessment of the imaging
resolution of a system of mirrors is better obtained via a direct,
full-illumination test in X-rays. If the focus cannot be reached, an
intra-focus test can be performed, and the image can be compared with the
simulation results based on the metrology, if available. However, until today
no quantitative information was extracted from a full-illumination, intra-focal
exposure. In this work we show that, if the detector is located at an optimal
distance from the mirror, the intensity variations of the intra-focal,
full-illumination image in single reflection can be used to reconstruct the
profile of the mirror surface, without the need of a wavefront sensor. The
Point Spread Function can be subsequently computed from the reconstructed
mirror shape. We show the application of this method to an intra-focal (8 m
distance from mirror) test performed at PANTER on an optical module prototype
made of hot-slumped glass foils with a 20 m focal length, from which we could
derive an expected imaging quality near 16 arcsec HEW.
[8]
oai:arXiv.org:1502.03308 [pdf] - 1303946
Development of mirrors made of chemically tempered glass foils for
future X-ray telescopes
Submitted: 2015-02-11
Thin slumped glass foils are considered good candidates for the realization
of future X-ray telescopes with large effective area and high spatial
resolution. However, the hot slumping process affects the glass strength, and
this can be an issue during the launch of the satellite because of the high
kinematical and static loads occurring during that phase. In the present work
we have investigated the possible use of Gorilla glass (produced by Corning), a
chemical tempered glass that, thanks to its strength characteristics, would be
ideal. The un-tempered glass foils were curved by means of an innovative hot
slumping technique and subsequently chemically tempered. In this paper we show
that the chemical tempering process applied to Gorilla glass foils does not
affect the surface micro-roughness of the mirrors. On the other end, the stress
introduced by the tempering process causes a reduction in the amplitude of the
longitudinal profile errors with a lateral size close to the mirror length. The
effect of the overall shape changes in the final resolution performance of the
glass mirrors was studied by simulating the glass foils integration with our
innovative approach based on glass reinforcing ribs. The preliminary tests
performed so far suggest that this approach has the potential to be applied to
the X-ray telescopes of the next generation.
[9]
oai:arXiv.org:1402.3445 [pdf] - 1203354
Evaluation of the surface strength of glass plates shaped by hot
slumping process
Proserpio, L.;
Basso, S.;
Borsa, F.;
Citterio, O.;
Civitani, M.;
Ghigo, M.;
Pareschi, G.;
Salmaso, B.;
Sironi, G.;
Spiga, D.;
Tagliaferri, G.;
D'Este, A.;
Dall'Igna, R.;
Silvestri, M.;
Parodi, G.;
Martelli, F.;
Bavdaz, M.;
Wille, E.
Submitted: 2014-02-14, last modified: 2014-07-09
The Hot Slumping Technology is under development by several research groups
in the world for the realization of grazing-incidence segmented mirrors for
X-ray astronomy, based on thin glass plates shaped over a mould at temperatures
above the transformation point. The performed thermal cycle and related
operations might have effects on the strength characteristics of the glass,
with consequences on the structural design of the elemental optical modules and
consecutively on the entire X-ray optic for large astronomical missions like
IXO and ATHENA. The mechanical strength of glass plates after they underwent
the slumping process was tested through destructive double-ring tests in the
context of a study performed by the Astronomical Observatory of Brera with the
collaboration of Stazione Sperimentale del Vetro and BCV Progetti. The entire
study has been realized on more than 200 D263 Schott borosilicate glass
specimens of dimension 100 mm x 100 mm and thickness 0.4 mm, either flat or
bent at a Radius of Curvature of 1000 mm through the particular pressure
assisted hot slumping process developed by INAF-OAB. The collected experimental
data have been compared to non-linear FEM analyses and treated with Weibull
statistic to assess the current IXO glass X-ray telescope design, in terms of
survival probability, when subject to static and acoustic loads characteristic
of the launch phase. The paper describes the activities performed and presents
the obtained results.
[10]
oai:arXiv.org:1309.6995 [pdf] - 1453148
XIPE: the X-ray Imaging Polarimetry Explorer
Soffitta, Paolo;
Barcons, Xavier;
Bellazzini, Ronaldo;
Braga, João;
Costa, Enrico;
Fraser, George W.;
Gburek, Szymon;
Huovelin, Juhani;
Matt, Giorgio;
Pearce, Mark;
Poutanen, Juri;
Reglero, Victor;
Santangelo, Andrea;
Sunyaev, Rashid A.;
Tagliaferri, Gianpiero;
Weisskopf, Martin;
Aloisio, Roberto;
Amato, Elena;
Attiná, Primo;
Axelsson, Magnus;
Baldini, Luca;
Basso, Stefano;
Bianchi, Stefano;
Blasi, Pasquale;
Bregeon, Johan;
Brez, Alessandro;
Bucciantini, Niccoló;
Burderi, Luciano;
Burwitz, Vadim;
Casella, Piergiorgio;
Churazov, Eugene;
Civitani, Marta;
Covino, Stefano;
da Silva, Rui Miguel Curado;
Cusumano, Giancarlo;
Dadina, Mauro;
D'Amico, Flavio;
De Rosa, Alessandra;
Di Cosimo, Sergio;
Di Persio, Giuseppe;
Di Salvo, Tiziana;
Dovciak, Michal;
Elsner, Ronald;
Eyles, Chris J.;
Fabian, Andrew C.;
Fabiani, Sergio;
Feng, Hua;
Giarrusso, Salvatore;
Goosmann, René W.;
Grandi, Paola;
Grosso, Nicolas;
Israel, Gianluca;
Jackson, Miranda;
Kaaret, Philip;
Karas, Vladimir;
Kuss, Michael;
Lai, Dong;
La Rosa, Giovanni;
Larsson, Josefin;
Larsson, Stefan;
Latronico, Luca;
Maggio, Antonio;
Maia, Jorge;
Marin, Frédéric;
Massai, Marco Maria;
Mineo, Teresa;
Minuti, Massimo;
Moretti, Elena;
Muleri, Fabio;
O'Dell, Stephen L.;
Pareschi, Giovanni;
Peres, Giovanni;
Pesce, Melissa;
Petrucci, Pierre-Olivier;
Pinchera, Michele;
Porquet, Delphine;
Ramsey, Brian;
Rea, Nanda;
Reale, Fabio;
Rodrigo, Juana Maria;
Różańska, Agata;
Rubini, Alda;
Rudawy, Pawel;
Ryde, Felix;
Salvati, Marco;
Júnior, Valdivino Alexandre de Santiago;
Sazonov, Sergey;
Sgró, Carmelo;
Silver, Eric;
Spandre, Gloria;
Spiga, Daniele;
Stella, Luigi;
Tamagawa, Toru;
Tamborra, Francesco;
Tavecchio, Fabrizio;
Dias, Teresa Teixeira;
van Adelsberg, Matthew;
Wu, Kinwah;
Zane, Silvia
Submitted: 2013-09-26
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and
temporal variability measurements and to imaging, allows a wealth of physical
phenomena in astrophysics to be studied. X-ray polarimetry investigates the
acceleration process, for example, including those typical of magnetic
reconnection in solar flares, but also emission in the strong magnetic fields
of neutron stars and white dwarfs. It detects scattering in asymmetric
structures such as accretion disks and columns, and in the so-called molecular
torus and ionization cones. In addition, it allows fundamental physics in
regimes of gravity and of magnetic field intensity not accessible to
experiments on the Earth to be probed. Finally, models that describe
fundamental interactions (e.g. quantum gravity and the extension of the
Standard Model) can be tested. We describe in this paper the X-ray Imaging
Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a
small mission with a launch in 2017 but not selected. XIPE is composed of two
out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD)
filled with a He-DME mixture at their focus and two additional GPDs filled with
pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 %
at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half
Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X
optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with
Malindi as down-link station and of a Mission Operation Center (MOC) at INPE
(Brazil).
[11]
oai:arXiv.org:0912.5331 [pdf] - 1018922
A wide field X-ray telescope for astronomical survey purposes: from
theory to practice
Submitted: 2009-12-29, last modified: 2010-02-11
X-ray mirrors are usually built in the Wolter I (paraboloid-hyperboloid)
configuration. This design exhibits no spherical aberration on-axis but suffers
from field curvature, coma and astigmatism, therefore the angular resolution
degrades rapidly with increasing off-axis angles. Different mirror designs
exist in which the primary and secondary mirror profiles are expanded as a
power series in order to increase the angular resolution at large off-axis
positions, at the expanses of the on-axis performances. Here we present the
design and global trade off study of an X-ray mirror systems based on
polynomial optics in view of the Wide Field X-ray Telescope (WFXT) mission.
WFXT aims at performing an extended cosmological survey in the soft X-ray band
with unprecedented flux sensitivity. To achieve these goals the angular
resolution required for the mission is very demanding ~5 arcsec mean resolution
across a 1-deg field of view. In addition an effective area of 5-9000 cm^2 at 1
keV is needed.
[12]
oai:arXiv.org:0903.2483 [pdf] - 22372
Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase
A Study
Tagliaferri, G.;
Basso, S.;
Borghi, G.;
Burkert, W.;
Citterio, O.;
Civitani, M.;
Conconi, P.;
Cotroneo, V.;
Freyberg, M.;
Garoli, D.;
Gorenstein, P.;
Hartner, G.;
Mattarello, V.;
Orlandi, A.;
Pareschi, G.;
Romaine, S.;
Spiga, D.;
Valsecchi, G.;
Vernani, D.
Submitted: 2009-03-13
Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong
improvement both in sensitivity and angular resolution compared to all
instruments that have operated so far above 10 keV. The superb hard X-ray
imaging capability will be guaranteed by a mirror module of 100 electroformed
Nickel shells with a multilayer reflecting coating. Here we will describe the
technogical development and solutions adopted for the fabrication of the mirror
module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec
from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A,
terminated at the end of 2008, we have developed three engineering models with
two, two and three shells, respectively. The most critical aspects in the
development of the Simbol-X mirrors are i) the production of the 100 mandrels
with very good surface quality within the timeline of the mission; ii) the
replication of shells that must be very thin (a factor of 2 thinner than those
of XMM-Newton) and still have very good image quality up to 80 keV; iii) the
development of an integration process that allows us to integrate these very
thin mirrors maintaining their intrinsic good image quality. The Phase A study
has shown that we can fabricate the mandrels with the needed quality and that
we have developed a valid integration process. The shells that we have produced
so far have a quite good image quality, e.g. HEW <~30 arcsec at 30 keV, and
effective area. However, we still need to make some improvements to reach the
requirements. We will briefly present these results and discuss the possible
improvements that we will investigate during phase B.