sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Chwalla, Michael

Normalized to: Chwalla, M.

3 article(s) in total. 18 co-authors, from 1 to 3 common article(s). Median position in authors list is 1,0.

[1]  oai:arXiv.org:2002.05669  [pdf] - 2109017
Optical suppression of tilt-to-length coupling in the LISA long-arm interferometer
Comments: 13 pages, 10 figures
Submitted: 2020-02-13, last modified: 2020-06-05
The arm length and the isolation in space enable LISA to probe for signals unattainable on ground, opening a window to the sub-Hz gravitational-wave universe. The coupling of unavoidable angular spacecraft jitter into the longitudinal displacement measurement, an effect known as tilt-to-length (TTL) coupling, is critical for realizing the required sensitivity of picometer$/\sqrt{\rm{Hz}}$. An ultra-stable interferometer testbed has been developed in order to investigate this issue and validate mitigation strategies in a setup representative of LISA, and in this paper it is operated in the long-arm interferometer configuration. The testbed is fitted with a flat-top beam generator to simulate the beam received by a LISA spacecraft. We demonstrate a reduction of TTL coupling between this flat-top beam and a Gaussian reference beam via introducing two- and four-lens imaging systems. TTL coupling factors below $\pm 25\,\mu$m/rad for beam tilts within $\pm 300\,\mu$rad are obtained by careful optimization of the system. Moreover we show that the additional TTL coupling due to lateral alignment errors of elements of the imaging system can be compensated by introducing lateral shifts of the detector, and vice versa. These findings help validate the suitability of this noise-reduction technique for the LISA long-arm interferometer.
[2]  oai:arXiv.org:1711.10320  [pdf] - 1669526
Reducing tilt-to-length coupling for the LISA test mass interferometer
Comments: This work will be submitted to CQG
Submitted: 2017-11-23
Objects sensed by laser interferometers are usually not stable in position or orientation. This angular instability can lead to a coupling of angular tilt to apparent longitudinal displacement -- tilt-to-length coupling (TTL). In LISA this is a potential noise source for both the test mass interferometer and the long-arm interferometer. We have experimentally investigated TTL coupling in a setup representative for the LISA test mass interferometer and used this system to characterise two different imaging systems (a two-lens design and a four-lens design) both designed to minimise TTL coupling. We show that both imaging systems meet the LISA requirement of +-25 um/rad for interfering beams with relative angles of up to +-300 urad. Furthermore, we found a dependency of the TTL coupling on beam properties such as the waist size and location, which we characterised both theoretically and experimentally.
[3]  oai:arXiv.org:1607.00408  [pdf] - 1526270
Design and construction of an optical test bed for LISA imaging systems and tilt-to-length coupling
Comments:
Submitted: 2016-07-01, last modified: 2016-12-02
The Laser Interferometer Space Antenna (LISA) is a future space-based interferometric gravitational-wave detector consisting of three spacecraft in a triangular configuration. The interferometric measurements of path length changes between satellites will be performed on optical benches in the satellites. Angular misalignments of the interfering beams couple into the length measurement and represent a significant noise source. Imaging systems will be used to reduce this tilt-to-length coupling. We designed and constructed an optical test bed to experimentally investigate tilt-to-length coupling. It consists of two separate structures, a minimal optical bench and a telescope simulator. The minimal optical bench comprises the science interferometer where the local laser is interfered with light from a remote spacecraft. In our experiment, a simulated version of this received beam is generated on the telescope simulator. The telescope simulator provides a tilting beam, a reference interferometer and an additional static beam as a phase reference. The tilting beam can either be a flat-top beam or a Gaussian beam. We avoid tilt-to-length coupling in the reference interferometer by using a small photo diode placed at an image of the beam rotation point. We show that the test bed is operational with an initial measurement of tilt-to-length coupling without imaging systems. Furthermore, we show the design of two different imaging systems whose performance will be investigated in future experiments.