Normalized to: Chung, R.
[1]
oai:arXiv.org:1102.5248 [pdf] - 1052361
First results from the MIT Optical Rapid Imaging System (MORIS) on the
IRTF: a stellar occultation by Pluto and a transit by exoplanet XO-2b
Gulbis, A. A. S.;
Bus, S. J.;
Elliot, J. L.;
Rayner, J. T.;
Stahlberger, W. E.;
Rojas, F. E.;
Adams, E. R.;
Person, M. J.;
Chung, R.;
Tokunaga, A. T.;
Zuluaga, C. A.
Submitted: 2011-02-25
We present a high-speed, visible-wavelength imaging instrument: MORIS (the
MIT Optical Rapid Imaging System). MORIS is mounted on the 3-m Infrared
Telescope Facility (IRTF) on Mauna Kea, HI. Its primary component is an Andor
iXon camera, a nearly 60 arcsec square field of view with high quantum
efficiency, low read noise, low dark current, and full-frame readout rates
ranging from as slow as desired to a maximum of between 3.5 Hz and 35 Hz
(depending on the mode; read noise of 6e-/pixel and 49 e-/pixel with
electron-multiplying gain=1, respectively). User-selectable binning and
subframing can increase the cadence to a few hundred Hz. An
electron-multiplying mode can be employed for photon counting, effectively
reducing the read noise to sub-electron levels at the expense of dynamic range.
Data cubes, or individual frames, can be triggered to several nanosecond
accuracy using the Global Positioning System. MORIS is mounted on the
side-facing exit window of SpeX (Rayner et al. 2003), allowing simultaneous
near-infrared and visible observations. Here we describe the components, setup,
and measured characteristics of MORIS. We also report results from the first
science observations: the 24 June 2008 stellar occultation by Pluto and an
extrasolar planetary transit by XO-2b. The Pluto occultation, of a 15.8 R
magnitude star, has signal-to-noise ratio of 35 per atmospheric scale height
and a midtime error of 0.32 s. The XO-2b transit reaches photometric precision
of 0.5 millimagnitudes in 2 minutes and has a midtime timing precision of 23
seconds.
[2]
oai:arXiv.org:astro-ph/0601588 [pdf] - 79446
The SPEAR Instrument and On-Orbit Performance
Edelstein, Jerry;
Korpela, Eric;
Adolfo, Joe;
Bowen, Mark;
Feuerstein, Michael;
Hull, Jeffrey;
Jelinsky, Sharon;
Nishikida, Kaori;
McKee, Ken;
Berg, Peter;
Chung, Ray;
Fischer, Jorg;
Min, Kyoung-Wook;
Oh, Seung-Han;
Rhee, Jin-Guen;
Ryu, Kwangsun;
Shinn, Jong-Ho;
Han, Wonyong;
Jin, Ho;
Lee, Dae-Hee;
Nam, Uk-Won;
Park, Jang-Hyun;
Seon, Kwang-Il;
Yuk, In-Soo
Submitted: 2006-01-26
The SPEAR (or 'FIMS') instrumentation has been used to conduct the first
large-scale spectral mapping of diffuse cosmic far ultraviolet (FUV, 900-1750
AA) emission, including important diagnostics of interstellar hot (10^4 K -
10^6 K) and photoionized plasmas, H_2, and dust scattered starlight. The
instrumentation's performance has allowed for the unprecedented detection of
astrophysical diffuse far UV emission lines. A spectral resolution of 550 and
an imaging resolution of 5' is achieved on-orbit in the Short (900 - 1175 AA)
and Long (1335 - 1750 AA) bandpass channels within their respective 7.4 deg x
4.3' and 4.0 deg x 4.6' fields of view. We describe the SPEAR imaging
spectrographs, their performance, and the nature and handling of their data.