Normalized to: Chott, N.
[1]
oai:arXiv.org:2005.14067 [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a
surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration;
Amaral, D. W.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Banik, S.;
Barker, D.;
Bathurst, C.;
Bauer, D. A.;
Bezerra, L. V. S.;
Bhattacharyya, R.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Chen, R.;
Chott, N.;
Cooley, J.;
Coombes, H.;
Corbett, J.;
Cushman, P.;
De Brienne, F.;
di Vacri, M. L.;
Diamond, M. D.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fouts, K.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hines, B. A.;
Hollister, M. I.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Li, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
MacFarlane, D. B.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mayer, A. J.;
Michaud, É. M.;
Michielin, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nagorny, S.;
Nelson, J.;
Neog, H.;
Novati, V.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Pakarha, P.;
Partridge, R.;
Podviianiuk, R.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Rau, W.;
Reid, E.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sattari, A.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Sincavage, D. J.;
Stanford, C.;
Stein, M.;
Street, J.;
Toback, D.;
Underwood, R.;
Verma, S.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wills, L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Yu, T. C.;
Zhang, E.;
Zhang, H. G.;
Zhao, X.;
Zheng, L.
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark
matter inelastically scattering off of electrons, and on dark photon and
axion-like particle absorption, using a second-generation SuperCDMS
high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV
phonon energy resolution; for a detector bias of 100 V, this corresponds to a
charge resolution of 3% of a single electron-hole pair. The energy spectrum is
reported from a blind analysis with 1.2 gram-days of exposure acquired in an
above-ground laboratory. With charge carrier trapping and impact ionization
effects incorporated into the dark matter signal models, the dark
matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter
masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50
eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the
axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90%
confidence-level upper limits within the above mentioned mass ranges are
$\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$,
$\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[3]
oai:arXiv.org:1209.2519 [pdf] - 621874
The low energy spectrum of TeO2 bolometers: results and dark matter
perspectives for the CUORE-0 and CUORE experiments
Alessandria, F.;
Ardito, R.;
Artusa, D. R.;
Avignone, F. T.;
Azzolini, O.;
Balata, M.;
Banks, T. I.;
Bari, G.;
Beeman, J.;
Bellini, F.;
Bersani, A.;
Biassoni, M.;
Bloxham, T.;
Brofferio, C.;
Bucci, C.;
Cai, X. Z.;
Canonica, L.;
Capelli, S.;
Carbone, L.;
Cardani, L.;
Carrettoni, M.;
Casali, N.;
Chott, N.;
Clemenza, M.;
Cosmelli, C.;
Cremonesi, O.;
Creswick, R. J.;
Dafinei, I.;
Dally, A.;
Datskov, V.;
De Biasi, A.;
Decowski, M. P.;
Deninno, M. M.;
Di Domizio, S.;
di Vacri, M. L.;
Ejzak, L.;
Faccini, R.;
Fang, D. Q.;
Farach, H. A.;
Ferri, E.;
Ferroni, F.;
Fiorini, E.;
Franceschi, M. A.;
Freedman, S. J.;
Frossati, G.;
Fujikawa, B. K.;
Giachero, A.;
Gironi, L.;
Giuliani, A.;
Goett, J. J.;
Gorla, P.;
Gotti, C.;
Guardincerri, E.;
Gutierrez, T. D.;
Haller, E. E.;
Han, K.;
Heeger, K. M.;
Huang, H. Z.;
Kadel, R.;
Kazkaz, K.;
Keppel, G.;
Kogler, L.;
Kolomensky, Yu. G.;
Lenz, D.;
Li, Y. L.;
Ligi, C.;
Liu, X.;
Ma, Y. G.;
Maiano, C.;
Maino, M.;
Martinez, M.;
Maruyama, R. H.;
Moggi, N.;
Morganti, S.;
Napolitano, T.;
Newman, S.;
Nisi, S.;
Nones, C.;
Norman, E. B.;
Nucciotti, A.;
Orio, F.;
Orlandi, D.;
Ouellet, J. L.;
Pallavicini, M.;
Palmieri, V.;
Pattavina, L.;
Pavan, M.;
Pedretti, M.;
Pessina, G.;
Pirro, S.;
Previtali, E.;
Rampazzo, V.;
Rimondi, F.;
Rosenfeld, C.;
Rusconi, C.;
Sangiorgio, S.;
Scielzo, N. D.;
Sisti, M.;
Smith, A. R.;
Stivanello, F.;
Taffarello, L.;
Tenconi, M.;
Tian, W. D.;
Tomei, C.;
Trentalange, S.;
Ventura, G.;
Vignati, M.;
Wang, B. S.;
Wang, H. W.;
Whitten, C. A.;
Wise, y T.;
Woodcraft, A.;
Zanotti, L.;
Zarra, C.;
Zhu, B. X.;
Zucchelli, S.
Submitted: 2012-09-12, last modified: 2013-02-01
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three
of them we were able to set the energy threshold around 3 keV using a new
analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3
keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak
is presently unknown, but its presence is confirmed by a reanalysis of 62.7
kg.days of data from the finished CUORICINO experiment. Finally, we report the
expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers)
experiments to a WIMP annual modulation signal.