sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Chisholm, E.

Normalized to: Chisholm, E.

10 article(s) in total. 153 co-authors, from 1 to 7 common article(s). Median position in authors list is 7,5.

[1]  oai:arXiv.org:1908.03623  [pdf] - 1935816
High-resolution Infrared Spectrograph for Exoplanet Characterization with the Keck and Thirty Meter Telescopes
Comments:
Submitted: 2019-08-09
HISPEC (High-resolution Infrared Spectrograph for Exoplanet Characterization) is a proposed diffraction-limited spectrograph for the W.M. Keck Observatory, and a pathfinder for the MODHIS facility project (Multi-Object Diffraction-limited High-resolution Infrared Spectrograph) on the Thirty Meter Telescope. HISPEC/MODHIS builds on diffraction-limited spectrograph designs which rely on adaptively corrected single-mode fiber feeds. Seeing-limited high-resolution spectrographs, by virtue of the conservation of beam etendue, grow in volume following a D^3 power law (D is the telescope diameter), and are subject to daunting challenges associated with their large size. Diffraction-limited spectrographs fed by single mode fibers are decoupled from the telescope input, and are orders of magnitude more compact and have intrinsically stable line spread functions. Their efficiency is directly proportional to the performance of the adaptive optics (AO) system. AO technologies have matured rapidly over the past two decades and are baselined for future extremely large telescopes. HISPEC/MODHIS will take R>100,000 spectra of a few objects in a 10" field-of-view sampled at the diffraction limit (~10-50 mas), simultaneously from 0.95 to 2.4 microns (y-K). The scientific scope ranges from exoplanet infrared precision radial velocities, spectroscopy of transiting, close-in, and directly imaged exoplanets (atmospheric composition and dynamics, RM effect, spin measurements, Doppler imaging), brown dwarf characterization, stellar physics/chemistry, proto-planetary disk kinematics/composition, Solar system, extragalactic science, and cosmology. HISPEC/MODHIS features a compact, cost-effective design optimized to fully exploit the existing Keck-AO and future TMT-NFIRAOS infrastructures and boost the scientific reach of Keck Observatory and TMT soon after first light.
[2]  oai:arXiv.org:1808.07853  [pdf] - 1738019
The infrared imaging spectrograph (IRIS) for TMT: electronics-cable architecture
Comments:
Submitted: 2018-08-23
The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the Thirty Meter Telescope (TMT). It combines a diffraction limited imager and an integral field spectrograph. This paper focuses on the electrical system of IRIS. With an instrument of the size and complexity of IRIS we face several electrical challenges. Many of the major controllers must be located directly on the cryostat to reduce cable lengths, and others require multiple bulkheads and must pass through a large cable wrap. Cooling and vibration due to the rotation of the instrument are also major challenges. We will present our selection of cables and connectors for both room temperature and cryogenic environments, packaging in the various cabinets and enclosures, and techniques for complex bulkheads including for large detectors at the cryostat wall.
[3]  oai:arXiv.org:1808.07495  [pdf] - 1737988
The Infrared Imaging Spectrograph (IRIS) for TMT: advancing the data reduction system
Comments: 14 pages, 5 figures, 6 tables, Proceeding 10707-112 of the SPIE Astronomical Telescopes + Instrumentation 2018
Submitted: 2018-08-22
Infrared Imaging Spectrograph (IRIS) is the first light instrument for the Thirty Meter Telescope (TMT) that consists of a near-infrared (0.84 to 2.4 micron) imager and integral field spectrograph (IFS) which operates at the diffraction-limit utilizing the Narrow-Field Infrared Adaptive Optics System (NFIRAOS). The imager will have a 34 arcsec x 34 arcsec field of view with 4 milliarcsecond (mas) pixels. The IFS consists of a lenslet array and slicer, enabling four plate scales from 4 mas to 50 mas, multiple gratings and filters, which in turn will operate hundreds of individual modes. IRIS, operating in concert with NFIRAOS will pose many challenges for the data reduction system (DRS). Here we present the updated design of the real-time and post-processing DRS. The DRS will support two modes of operation of IRIS: (1) writing the raw readouts sent from the detectors and performing the sampling on all of the readouts for a given exposure to create a raw science frame; and (2) reduction of data from the imager, lenslet array and slicer IFS. IRIS is planning to save the raw readouts for a given exposure to enable sophisticated processing capabilities to the end users, such as the ability to remove individual poor seeing readouts to improve signal-to-noise, or from advanced knowledge of the point spread function (PSF). The readout processor (ROP) is a key part of the IRIS DRS design for writing and sampling of the raw readouts into a raw science frame, which will be passed to the TMT data archive. We discuss the use of sub-arrays on the imager detectors for saturation/persistence mitigation, on-detector guide windows, and fast readout science cases (< 1 second).
[4]  oai:arXiv.org:1808.07497  [pdf] - 1737990
The InfraRed Imaging Spectrograph (IRIS) for TMT: photometric precision and ghost analysis
Comments: SPIE 2018, 14 pages, 14 figures, 4 tables, Proceedings of SPIE 10702-373, Ground-based and Airborne Instrumentation for Astronomy VII, 10702A7 (16 July 2018)
Submitted: 2018-08-22
The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the Thirty Meter Telescope (TMT) that will be used to sample the corrected adaptive optics field by NFIRAOS with a near-infrared (0.8 - 2.4 $\mu$m) imaging camera and Integral Field Spectrograph (IFS). In order to understand the science case specifications of the IRIS instrument, we use the IRIS data simulator to characterize photometric precision and accuracy of the IRIS imager. We present the results of investigation into the effects of potential ghosting in the IRIS optical design. Each source in the IRIS imager field of view results in ghost images on the detector from IRIS's wedge filters, entrance window, and Atmospheric Dispersion Corrector (ADC) prism. We incorporated each of these ghosts into the IRIS simulator by simulating an appropriate magnitude point source at a specified pixel distance, and for the case of the extended ghosts redistributing flux evenly over the area specified by IRIS's optical design. We simulate the ghosting impact on the photometric capabilities, and found that ghosts generally contribute negligible effects on the flux counts for point sources except for extreme cases where ghosts coalign with a star of $\Delta$m$>$2 fainter than the ghost source. Lastly, we explore the photometric precision and accuracy for single sources and crowded field photometry on the IRIS imager.
[5]  oai:arXiv.org:1808.07504  [pdf] - 1737992
The Infrared Imaging Spectrograph (IRIS) for TMT: closed-loop adaptive optics while dithering
Comments: 21 pages, 19 figures, SPIE (2018) 10707-49
Submitted: 2018-08-22
The InfraRed Imaging Spectrograph (IRIS) is the first-light client instrument for the Narrow Field Infrared Adaptive Optics System (NFIRAOS) on the Thirty Meter Telescope (TMT). IRIS includes three natural guide star (NGS) On-Instrument Wavefront Sensors (OIWFS) to measure tip/tilt and focus errors in the instrument focal plane. NFIRAOS also has an internal natural guide star wavefront sensor, and IRIS and NFIRAOS must precisely coordinate the motions of their wavefront sensor positioners to track the locations of NGSs while the telescope is dithering (offsetting the telescope to cover more area), to avoid a costly re-acquisition time penalty. First, we present an overview of the sequencing strategy for all of the involved subsystems. We then predict the motion of the telescope during dithers based on finite-element models provided by TMT, and finally analyze latency and jitter issues affecting the propagation of position demands from the telescope control system to individual motor controllers.
[6]  oai:arXiv.org:1608.01720  [pdf] - 1531197
The Infrared Imaging Spectrograph (IRIS) for TMT: Instrument Overview
Comments: 13 pages, SPIE proceeedings
Submitted: 2016-08-04
IRIS is a near-infrared (0.84 to 2.4 microns) integral field spectrograph and wide-field imager being developed for first light with the Thirty Meter (TMT). It mounts to the advanced optics (AO) system NFIRAOS and has integrated on-instrument wavefront sensors (OIWFS) to achieve diffraction-limited spatial resolution at wavelengths longer than 1 micron. With moderate spectral resolution (R ~4,000 - 8,000) and large bandpass over a continuous field of view, IRIS will open new opportunities in virtually every area of astrophysical science. It will be able to resolve surface features tens of kilometers across Titan, while also mapping the distant galaxies at the scale of an individual star forming region. This paper summarizes the entire design and capabilities, and includes the results from the nearly completed preliminary design phase.
[7]  oai:arXiv.org:1608.01693  [pdf] - 1531195
Flowdown of the TMT astrometry error budget(s) to the IRIS design
Comments: 8 pages, 4 figures. Proceeding of SPIE, Astronomical Telescopes and Instrumentation 2016
Submitted: 2016-08-04
TMT has defined the accuracy to be achieved for both absolute and differential astrometry in its top-level requirements documents. Because of the complexities of different types of astrometric observations, these requirements cannot be used to specify system design parameters directly. The TMT astrometry working group therefore developed detailed astrometry error budgets for a variety of science cases. These error budgets detail how astrometric errors propagate through the calibration, observing and data reduction processes. The budgets need to be condensed into sets of specific requirements that can be used by each subsystem team for design purposes. We show how this flowdown from error budgets to design requirements is achieved for the case of TMT's first-light Infrared Imaging Spectrometer (IRIS) instrument.
[8]  oai:arXiv.org:1608.01696  [pdf] - 1450732
The InfraRed Imaging Spectrograph (IRIS) for TMT: latest science cases and simulations
Comments: 15 pages, 7 figures, SPIE (2016) 9909-05
Submitted: 2016-08-04
The Thirty Meter Telescope (TMT) first light instrument IRIS (Infrared Imaging Spectrograph) will complete its preliminary design phase in 2016. The IRIS instrument design includes a near-infrared (0.85 - 2.4 micron) integral field spectrograph (IFS) and imager that are able to conduct simultaneous diffraction-limited observations behind the advanced adaptive optics system NFIRAOS. The IRIS science cases have continued to be developed and new science studies have been investigated to aid in technical performance and design requirements. In this development phase, the IRIS science team has paid particular attention to the selection of filters, gratings, sensitivities of the entire system, and science cases that will benefit from the parallel mode of the IFS and imaging camera. We present new science cases for IRIS using the latest end-to-end data simulator on the following topics: Solar System bodies, the Galactic center, active galactic nuclei (AGN), and distant gravitationally-lensed galaxies. We then briefly discuss the necessity of an advanced data management system and data reduction pipeline.
[9]  oai:arXiv.org:1006.4160  [pdf] - 1033224
Reverberation Mapping Measurements of Black Hole Masses in Six Local Seyfert Galaxies
Comments: 52 pages (AASTeX: 29 pages of text, 8 tables, 7 figures), accepted for publication in the Astrophysical Journal
Submitted: 2010-06-21
We present the final results from a high sampling rate, multi-month, spectrophotometric reverberation mapping campaign undertaken to obtain either new or improved Hbeta reverberation lag measurements for several relatively low-luminosity AGNs. We have reliably measured thetime delay between variations in the continuum and Hbeta emission line in six local Seyfert 1 galaxies. These measurements are used to calculate the mass of the supermassive black hole at the center of each of these AGNs. We place our results in context to the most current calibration of the broad-line region (BLR) R-L relationship, where our results remove outliers and reduce the scatter at the low-luminosity end of this relationship. We also present velocity-resolved Hbeta time delay measurements for our complete sample, though the clearest velocity-resolved kinematic signatures have already been published.
[10]  oai:arXiv.org:0908.0327  [pdf] - 294729
Diverse Broad Line Region Kinematic Signatures From Reverberation Mapping
Comments: 5 pages, 3 figures, accepted for publication in ApJL
Submitted: 2009-08-04, last modified: 2009-09-25
A detailed analysis of the data from a high sampling rate, multi-month reverberation mapping campaign, undertaken primarily at MDM Observatory with supporting observations from telescopes around the world, reveals that the Hbeta emission region within the broad line regions (BLRs) of several nearby AGNs exhibit a variety of kinematic behaviors. While the primary goal of this campaign was to obtain either new or improved Hbeta reverberation lag measurements for several relatively low luminosity AGNs (presented in a separate work), we were also able to unambiguously reconstruct velocity-resolved reverberation signals from a subset of our targets. Through high cadence spectroscopic monitoring of the optical continuum and broad Hbeta emission line variations observed in the nuclear regions of NGC 3227, NGC 3516, and NGC 5548, we clearly see evidence for outflowing, infalling, and virialized BLR gas motions, respectively.