Normalized to: Chipaux, R.
[1]
oai:arXiv.org:1512.00305 [pdf] - 1449892
Fast-neutron induced background in LaBr3:Ce detectors
Kiener, J.;
Tatischeff, V.;
Deloncle, I.;
de Séréville, N.;
Laurent, P.;
Blondel, C.;
Chabot, M.;
Chipaux, R.;
Coc, A.;
Dubos, S.;
Gostojic, A.;
Goutev, N.;
Hamadache, C.;
Hammache, F.;
Horeau, B.;
Limousin, O.;
Ouichaoui, S.;
Prévot, G.;
Rodríguez-Gasén, R.;
Yavahchova, M. S.
Submitted: 2015-12-01
The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce
crystal to incident neutrons has been measured in the energy range En = 2-12
MeV. Neutrons were produced by proton irradiation of a Li target at Ep = 5-14.6
MeV with pulsed proton beams. Using the time-of-flight information between
target and detector, energy spectra of the LaBr3:Ce detector resulting from
fast neutron interactions have been obtained at 4 different neutron energies.
Neutron-induced gamma rays emitted by the LaBr3:Ce crystal were also measured
in a nearby Ge detector at the lowest proton beam energy. In addition, we
obtained data for neutron irradiation of a large-volume high-purity Ge detector
and of a NE-213 liquid scintillator detector, both serving as monitor detectors
in the experiment. Monte-Carlo type simulations for neutron interactions in the
liquid scintillator, the Ge and LaBr3:Ce crystals have been performed and
compared with measured data. Good agreement being obtained with the data, we
present the results of simulations to predict the response of LaBr3:Ce
detectors for a range of crystal sizes to neutron irradiation in the energy
range En = 0.5-10 MeV
[2]
oai:arXiv.org:1507.00204 [pdf] - 1240583
The Microchannel X-ray Telescope on Board the SVOM Satellite
Gotz, D.;
Adami, C.;
Basa, S.;
Beckmann, V.;
Burwitz, V.;
Chipaux, R.;
Cordier, B.;
Evans, P.;
Godet, O.;
Goosmann, R.;
Meidinger, N.;
Meuris, A.;
Motch, C.;
Nandra, K.;
O'Brien, P.;
Osborne, J.;
Perinati, E.;
Rau, A.;
Willingale, R.;
Mercier, K.;
Gonzalez, F.
Submitted: 2015-07-01
We present the Micro-channel X-ray Telescope (MXT), a new narrow-field (about
1{\deg}) telescope that will be flying on the Sino-French SVOM mission
dedicated to Gamma-Ray Burst science, scheduled for launch in 2021. MXT is
based on square micro pore optics (MPOs), coupled with a low noise CCD. The
optics are based on a "Lobster Eye" design, while the CCD is a focal plane
detector similar to the type developed for the seven eROSITA telescopes. MXT is
a compact and light (<35 kg) telescope with a 1 m focal length, and it will
provide an effective area of about 45 cmsq on axis at 1 keV. The MXT PSF is
expected to be better than 4.2 arc min (FWHM) ensuring a localization accuracy
of the afterglows of the SVOM GRBs to better than 1 arc min (90\% c.l. with no
systematics) provided MXT data are collected within 5 minutes after the
trigger. The MXT sensitivity will be adequate to detect the afterglows for
almost all the SVOM GRBs as well as to perform observations of non-GRB
astrophysical objects. These performances are fully adapted to the SVOM science
goals, and prove that small and light telescopes can be used for future small
X-ray missions.
[3]
oai:arXiv.org:1505.00976 [pdf] - 988459
Hard X-ray polarimetry with Caliste, a high performance CdTe based
imaging spectrometer
Antier, S.;
Ferrando, P.;
Limousin, O.;
Caroli, E.;
da Silva, R. M. Curado;
Blondel, C.;
Chipaux, R.;
Honkimaki, V.;
Horeau, B.;
Laurent, P.;
Maia, J. M.;
Meuris, A.;
Del Sordo, S.;
Stephen, J. B.
Submitted: 2015-05-05
Since the initial exploration of soft gamma-ray sky in the 60's, high-energy
celestial sources have been mainly characterized through imaging, spectroscopy
and timing analysis. Despite tremendous progress in the field, the radiation
mechanisms at work in sources such as neutrons stars and black holes are still
unclear. The polarization state of the radiation is an observational parameter
which brings key additional information about the physical process. This is why
most of the projects for the next generation of space missions covering the
tens of keV to the MeV region require a polarization measurement capability. A
key element enabling this capability is a detector system allowing the
identification and characterization of Compton interactions as they are the
main process at play. The hard X-ray imaging spectrometer module, developed in
CEA with the generic name of Caliste module, is such a detector. In this paper,
we present experimental results for two types of Caliste-256 modules, one based
on a CdTe crystal, the other one on a CdZnTe crystal, which have been exposed
to linearly polarized beams at the European Synchrotron Radiation Facility.
These results, obtained at 200-300 keV, demonstrate their capability to give an
accurate determination of the polarization parameters (polarization angle and
fraction) of the incoming beam. Applying a selection to our data set,
equivalent to select 90 degrees Compton scattered interactions in the detector
plane, we find a modulation factor Q of 0.78. The polarization angle and
fraction are derived with accuracies of approximately 1 degree and 5%. The
modulation factor remains larger than 0.4 when essentially no selection is made
at all on the data. These results prove that the Caliste-256 modules have
performances allowing them to be excellent candidates as detectors with
polarimetric capabilities, in particular for future space missions.
[4]
oai:arXiv.org:1104.1544 [pdf] - 342044
The COSPIX mission: focusing on the energetic and obscured Universe
Ferrando, P.;
Goldwurm, A.;
Laurent, P.;
Limousin, O.;
Beckmann, V.;
Arnaud, M.;
Barcons, X.;
Bomans, D.;
Caballero, I.;
Carrera, F.;
Chaty, S.;
Chenevez, J.;
Chipaux, R.;
Christensen, F.;
Claret, A.;
Corbel, S.;
Croston, J.;
Daddi, E.;
De Becker, M.;
Decourchelle, A.;
Elbaz, D.;
Falanga, M.;
Ferrari, C.;
Feruglio, C.;
Götz, D.;
Gouiffès, C.;
Hailey, C.;
Hernanz, M.;
Kreykenbohm, I.;
Malzac, J.;
Martignac, J.;
Mattana, F.;
Meuris, A.;
Miniutti, G.;
Nalewajko, K.;
Negueruela, I.;
O'Dell, S.;
Paltani, S.;
Petre, R.;
Petrucci, P. -O.;
Pierre, M.;
Pinsard, F.;
Ponti, G.;
Rauw, G.;
Rea, N.;
Renaud, M.;
Robert, J. -L.;
Rodriguez, J.;
Rozanska, A.;
Santangelo, A.;
Sauvageot, J. -L.;
Soldi, S.;
Tagger, M.;
Tenzer, C.;
Terrier, R.;
Trap, G.;
Varnière, P.;
Wilms, J.;
Zhang, W.;
Heras, J. Zurita
Submitted: 2011-04-08
Tracing the formation and evolution of all supermassive black holes,
including the obscured ones, understanding how black holes influence their
surroundings and how matter behaves under extreme conditions, are recognized as
key science objectives to be addressed by the next generation of instruments.
These are the main goals of the COSPIX proposal, made to ESA in December 2010
in the context of its call for selection of the M3 mission. In addition,
COSPIX, will also provide key measurements on the non thermal Universe,
particularly in relation to the question of the acceleration of particles, as
well as on many other fundamental questions as for example the energetic
particle content of clusters of galaxies. COSPIX is proposed as an observatory
operating from 0.3 to more than 100 keV. The payload features a single long
focal length focusing telescope offering an effective area close to ten times
larger than any scheduled focusing mission at 30 keV, an angular resolution
better than 20 arcseconds in hard X-rays, and polarimetric capabilities within
the same focal plane instrumentation. In this paper, we describe the science
objectives of the mission, its baseline design, and its performances, as
proposed to ESA.
[5]
oai:arXiv.org:0912.0233 [pdf] - 31227
Progress and Validation of Geant4 Based Radioactive Decay Simulation
Using the Examples of Simbol-X and IXO
Hauf, S.;
Kuster, M.;
Pia, M. G.;
Bell, Z.;
Briel, U.;
Chipaux, R.;
Hoffmann, D. H. H.;
Kendziorra, E.;
Laurent, P.;
Strüder, L.;
Tenzer, C.;
Weidenspointer, G.;
Zoglauer, A.
Submitted: 2009-12-01
The anticipated high sensitivity and the science goals of the next generation
X-ray space missions, like the International X-ray Observatory or Simbol-X,
rely on a low instrumental background, which in turn requires optimized
shielding concepts. We present Geant4 based simulation results on the IXO Wide
Field Imager cosmic ray proton induced background in comparison with previous
results obtained for the Simbol-X LED and HED focal plane detectors. Our
results show that an improvement in mean differential background flux compared
to actually operating X-ray observatories may be feasible with detectors based
on DEPFET technology. In addition we present preliminary results concerning the
validation of Geant4 based radioactive decay simulation in space applications
as a part of the Nano5 project.
[6]
oai:arXiv.org:0802.3846 [pdf] - 10438
Simbol-X background simulation activities
Submitted: 2008-02-26
Using the Geant4 toolkit, a Monte-Carlo code to simulate the detector
background of the Simbol-X focal plane instrument has been developed with the
aim to optimize the design of the instrument. Structural design models of the
mirror and detector satellites have been built and used as baseline for our
simulations, to evaluate the different background contributions that must be
taken into account to determine the sensitivity of the Simbol-X detectors. We
work towards a simulation based background and mass model which can be used
before and during the mission.
For different material compositions, material thicknesses, locations etc. the
response of the instrument to the diffuse cosmic hard X-ray background and to
the cosmic proton induced background have been calculated. As a result we
present estimates of the background count rate expected in the low and high
energy detector, and anti-coincidence rates. The effect of induced
radioactivity in the detector and shielding materials and soft proton
scattering in the mirror shells are also under study.