Normalized to: Chiosso, M.
[1]
oai:arXiv.org:0706.3236 [pdf] - 1934144
Measurement of Aerosols at the Pierre Auger Observatory
BenZvi, S. Y.;
Arqueros, F.;
Cester, R.;
Chiosso, M.;
Connolly, B. M.;
Fick, B.;
Filipcic, A.;
García, B.;
Grillo, A.;
Guarino, F.;
Horvat, M.;
Iarlori, M.;
Macolino, C.;
Malek, M.;
Matthews, J.;
Matthews, J. A. J.;
Melo, D.;
Meyhandan, R.;
Micheletti, M.;
Monasor, M.;
Mostafá, M.;
Mussa, R.;
Pallotta, J.;
Petrera, S.;
Prouza, M.;
Rizi, V.;
Roberts, M.;
Rojo, J. R. Rodriguez;
Rodríguez-Frías, D.;
Salamida, F.;
Santander, M.;
Sequeiros, G.;
Sommers, P.;
Tonachini, A.;
Valore, L.;
Verberic, D.;
Visbal, E.;
Westerhoff, S.;
Wiencke, L.;
Zavrtanik, D.;
Zavrtanik, M.
Submitted: 2007-06-21
The air fluorescence detectors (FDs) of the Pierre Auger Observatory are
vital for the determination of the air shower energy scale. To compensate for
variations in atmospheric conditions that affect the energy measurement, the
Observatory operates an array of monitoring instruments to record hourly
atmospheric conditions across the detector site, an area exceeding 3,000 square
km. This paper presents results from four instruments used to characterize the
aerosol component of the atmosphere: the Central Laser Facility (CLF), which
provides the FDs with calibrated laser shots; the scanning backscatter lidars,
which operate at three FD sites; the Aerosol Phase Function monitors (APFs),
which measure the aerosol scattering cross section at two FD locations; and the
Horizontal Attenuation Monitor (HAM), which measures the wavelength dependence
of aerosol attenuation.
[2]
oai:arXiv.org:astro-ph/0609063 [pdf] - 148741
The Lidar System of the Pierre Auger Observatory
BenZvi, S. Y.;
Cester, R.;
Chiosso, M.;
Connolly, B. M.;
Filipcic, A.;
Garcia, B.;
Grillo, A.;
Guarino, F.;
Horvat, M.;
Iarlori, M.;
Macolino, C.;
Matthews, J. A. J.;
Melo, D.;
Mussa, R.;
Mostafa, M.;
Pallota, J.;
Petrera, S.;
Prouza, M.;
Rizi, V.;
Roberts, M.;
Rojo, J. R. Rodriguez;
Salamida, F.;
Santander, M.;
Sequeiros, G.;
Tonachini, A.;
Valore, L.;
Veberic, D.;
Westerhoff, S.;
Zavrtanik, D.;
Zavrtanik, M.
Submitted: 2006-09-03, last modified: 2007-03-31
The Pierre Auger Observatory in Malargue, Argentina, is designed to study the
origin of ultrahigh energy cosmic rays with energies above 10^18 eV. The energy
calibration of the detector is based on a system of four air fluorescence
detectors. To obtain reliable calorimetric information from the fluorescence
stations, the atmospheric conditions at the experiment's site need to be
monitored continuously during operation. One of the components of the
observatory's atmospheric monitoring system is a set of four elastic
backscatter lidar stations, one station at each of the fluorescence detector
sites. This paper describes the design, current status, standard operation
procedure, and performance of the lidar system of the Pierre Auger Observatory.
[3]
oai:arXiv.org:astro-ph/0305389 [pdf] - 56862
Pierre Auger Atmosphere-Monitoring Lidar System
Filipcic, A.;
Horvat, M.;
Veberic, D.;
Zavrtanik, D.;
Zavrtanik, M.;
Chiosso, M.;
Mussa, R.;
Sequeiros, G.;
Mostafa, M. A.;
Roberts, M. D.
Submitted: 2003-05-21
The fluorescence-detection techniques of cosmic-ray air-shower experiments
require precise knowledge of atmospheric properties to reconstruct air-shower
energies. Up to now, the atmosphere in desert-like areas was assumed to be
stable enough so that occasional calibration of atmospheric attenuation would
suffice to reconstruct shower profiles. However, serious difficulties have been
reported in recent fluorescence-detector experiments causing systematic errors
in cosmic ray spectra at extreme energies. Therefore, a scanning backscatter
lidar system has been constructed for the Pierre Auger Observatory in Malargue,
Argentina, where on-line atmospheric monitoring will be performed. One lidar
system is already deployed at the Los Leones fluorescence detector site and the
second one is currently (April 2003) under construction at the Coihueco site.
Next to the established ones, a novel analysis method with assumption on
horizontal invariance, using multi-angle measurements is shown to unambiguously
measure optical depth, as well as absorption and backscatter coefficient.