Normalized to: Chiem, E.
[1]
oai:arXiv.org:1612.04473 [pdf] - 1540143
Radio detection of air showers with the ARIANNA experiment on the Ross
Ice Shelf
Barwick, S. W.;
Besson, D. Z.;
Burgman, A.;
Chiem, E.;
Hallgren, A.;
Hanson, J. C.;
Klein, S. R.;
Kleinfelder, S.;
Nelles, A.;
Persichilli, C.;
Phillips, S.;
Prakash, T.;
Reed, C.;
Shively, S. R.;
Tatar, J.;
Unger, E.;
Walker, J.;
Yodh, G.
Submitted: 2016-12-13, last modified: 2017-03-01
The ARIANNA hexagonal radio array (HRA) is an experiment in its pilot phase
designed to detect cosmogenic neutrinos of energies above 10^16 eV. The most
neutrino-like background stems from the radio emission of air showers. This
article reports on dedicated efforts of simulating and detecting the signals of
cosmic rays. A description of the fully radio self-triggered data-set, the
properties of the detected air shower signals in the frequency range of
\unit[100-500]{MHz} and the consequences for neutrino detection are given. 38
air shower signals are identified by their distinct waveform characteristics,
are in good agreement with simulations and their signals provide evidence that
neutrino-induced radio signals will be distinguishable with high efficiency in
ARIANNA. The cosmic ray flux at a mean energy of
$6.5^{+1.2}_{-1.0}\times10^{17}$ eV is measured to be
$1.1^{+1.0}_{-0.7}\times10^{-16}$ eV$^{-1}$km$^{-2}$sr$^{-1}$yr$^{-1}$ and one
five-fold coincident event is used to illustrate the capabilities of the
ARIANNA detector to reconstruct arrival direction and energy of air showers.
[2]
oai:arXiv.org:1508.02460 [pdf] - 1526819
The SST Multi-G-Sample/s Switched Capacitor Array Waveform Recorder with
Flexible Trigger and Picosecond-Level Timing Accuracy
Submitted: 2015-08-10
The design and performance of a multi-G-sample/s fully-synchronous analog
transient waveform recorder I.C. ("SST") with fast and flexible trigger
capabilities is presented. Containing 4 channels of 256 samples per channel and
fabricated in a 0.25 {\mu}m CMOS process, it has a 1.9V input range on a 2.5V
supply, achieves 12 bits of dynamic range, and uses ~160 mW while operating at
2 G-samples/s and full trigger speeds. With a standard 50 Ohm input source, the
SST's analog input bandwidth is ~1.3 GHz within about +/-0.5 dB and reaches a
-3 dB bandwidth of 1.5 GHz. The SST's internal sample clocks are generated
synchronously via a shift register driven by an external LVDS oscillator,
interleaved to double its speed (e.g., a 1 GHz clock yields 2 G-samples/s). It
can operate over 6 orders of magnitude in sample rates (2 kHz to 2 GHz). Only
three active control lines are necessary for operation: Reset, Start/Stop and
Read-Clock. Each of the four channels integrates dual-threshold discrimination
of signals with ~1 mV RMS resolution at >600 MHz bandwidth. Comparator results
are directly available for simple threshold monitoring and rate control. The
High and Low discrimination can also be AND'd over an adjustable window of time
in order to exclusively trigger on bipolar impulsive signals. Trigger outputs
can be CMOS or low-voltage differential signals, e.g. 1.2V CMOS or positive-ECL
(0-0.8V) for low noise. After calibration, the imprecision of timing
differences between channels falls in a range of 1.12-2.37 ps sigma at 2
G-samples/s.
[3]
oai:arXiv.org:1505.07085 [pdf] - 1526817
The SST Fully-Synchronous Multi-GHz Analog Waveform Recorder with
Nyquist-Rate Bandwidth and Flexible Trigger Capabilities
Submitted: 2015-05-26
The design and performance of a fully-synchronous multi-GHz analog transient
waveform recorder I.C. ("SST") with fast and flexible trigger capabilities is
presented. The SST's objective is to provide multi-GHz sample rates with
intrinsically-stable timing, Nyquist-rate sampling and high trigger bandwidth,
wide dynamic range and simple operation. Containing 4 channels of 256 samples
per channel, the SST is fabricated in an inexpensive 0.25 micrometer CMOS
process and uses a high-performance package that is 8 mm on a side. It has a
1.9V input range on a 2.5V supply, exceeds 12 bits of dynamic range, and uses
~128 mW while operating at 2 G-samples/s and full trigger rates. With a
standard 50 Ohm input source, the SST exceeds ~1.5 GHz -3 dB bandwidth. The
SST's internal sample clocks are generated synchronously via a shift register
driven by an external LVDS oscillator running at half the sample rate (e.g., a
1 GHz oscillator yields 2 G-samples/s). Because of its purely-digital
synchronous nature, the SST has ps-level timing uniformity that is independent
of sample frequencies spanning over 6 orders of magnitude: from under 2 kHz to
over 2 GHz. Only three active control lines are necessary for operation: Reset,
Start/Stop and Read-Clock. When operating as common-stop device, the time of
the stop, modulo 256 relative to the start, is read out along with the sampled
signal values. Each of the four channels integrates dual-threshold trigger
circuitry with windowed coincidence features. Channels can discriminate signals
with ~1mV RMS resolution at >600 MHz bandwidth.