sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Chiem, Edwin

Normalized to: Chiem, E.

3 article(s) in total. 17 co-authors, from 1 to 3 common article(s). Median position in authors list is 2,0.

[1]  oai:arXiv.org:1612.04473  [pdf] - 1540143
Radio detection of air showers with the ARIANNA experiment on the Ross Ice Shelf
Comments: 31 pages, 20 figures
Submitted: 2016-12-13, last modified: 2017-03-01
The ARIANNA hexagonal radio array (HRA) is an experiment in its pilot phase designed to detect cosmogenic neutrinos of energies above 10^16 eV. The most neutrino-like background stems from the radio emission of air showers. This article reports on dedicated efforts of simulating and detecting the signals of cosmic rays. A description of the fully radio self-triggered data-set, the properties of the detected air shower signals in the frequency range of \unit[100-500]{MHz} and the consequences for neutrino detection are given. 38 air shower signals are identified by their distinct waveform characteristics, are in good agreement with simulations and their signals provide evidence that neutrino-induced radio signals will be distinguishable with high efficiency in ARIANNA. The cosmic ray flux at a mean energy of $6.5^{+1.2}_{-1.0}\times10^{17}$ eV is measured to be $1.1^{+1.0}_{-0.7}\times10^{-16}$ eV$^{-1}$km$^{-2}$sr$^{-1}$yr$^{-1}$ and one five-fold coincident event is used to illustrate the capabilities of the ARIANNA detector to reconstruct arrival direction and energy of air showers.
[2]  oai:arXiv.org:1508.02460  [pdf] - 1526819
The SST Multi-G-Sample/s Switched Capacitor Array Waveform Recorder with Flexible Trigger and Picosecond-Level Timing Accuracy
Comments: 9 pages, 16 figures, 1 table
Submitted: 2015-08-10
The design and performance of a multi-G-sample/s fully-synchronous analog transient waveform recorder I.C. ("SST") with fast and flexible trigger capabilities is presented. Containing 4 channels of 256 samples per channel and fabricated in a 0.25 {\mu}m CMOS process, it has a 1.9V input range on a 2.5V supply, achieves 12 bits of dynamic range, and uses ~160 mW while operating at 2 G-samples/s and full trigger speeds. With a standard 50 Ohm input source, the SST's analog input bandwidth is ~1.3 GHz within about +/-0.5 dB and reaches a -3 dB bandwidth of 1.5 GHz. The SST's internal sample clocks are generated synchronously via a shift register driven by an external LVDS oscillator, interleaved to double its speed (e.g., a 1 GHz clock yields 2 G-samples/s). It can operate over 6 orders of magnitude in sample rates (2 kHz to 2 GHz). Only three active control lines are necessary for operation: Reset, Start/Stop and Read-Clock. Each of the four channels integrates dual-threshold discrimination of signals with ~1 mV RMS resolution at >600 MHz bandwidth. Comparator results are directly available for simple threshold monitoring and rate control. The High and Low discrimination can also be AND'd over an adjustable window of time in order to exclusively trigger on bipolar impulsive signals. Trigger outputs can be CMOS or low-voltage differential signals, e.g. 1.2V CMOS or positive-ECL (0-0.8V) for low noise. After calibration, the imprecision of timing differences between channels falls in a range of 1.12-2.37 ps sigma at 2 G-samples/s.
[3]  oai:arXiv.org:1505.07085  [pdf] - 1526817
The SST Fully-Synchronous Multi-GHz Analog Waveform Recorder with Nyquist-Rate Bandwidth and Flexible Trigger Capabilities
Comments: 3 pages, 6 figures, 1 table, submitted for publication in the Conference Record of the 2014 IEEE Nuclear Science Symposium, Seattle, WA, November 2014
Submitted: 2015-05-26
The design and performance of a fully-synchronous multi-GHz analog transient waveform recorder I.C. ("SST") with fast and flexible trigger capabilities is presented. The SST's objective is to provide multi-GHz sample rates with intrinsically-stable timing, Nyquist-rate sampling and high trigger bandwidth, wide dynamic range and simple operation. Containing 4 channels of 256 samples per channel, the SST is fabricated in an inexpensive 0.25 micrometer CMOS process and uses a high-performance package that is 8 mm on a side. It has a 1.9V input range on a 2.5V supply, exceeds 12 bits of dynamic range, and uses ~128 mW while operating at 2 G-samples/s and full trigger rates. With a standard 50 Ohm input source, the SST exceeds ~1.5 GHz -3 dB bandwidth. The SST's internal sample clocks are generated synchronously via a shift register driven by an external LVDS oscillator running at half the sample rate (e.g., a 1 GHz oscillator yields 2 G-samples/s). Because of its purely-digital synchronous nature, the SST has ps-level timing uniformity that is independent of sample frequencies spanning over 6 orders of magnitude: from under 2 kHz to over 2 GHz. Only three active control lines are necessary for operation: Reset, Start/Stop and Read-Clock. When operating as common-stop device, the time of the stop, modulo 256 relative to the start, is read out along with the sampled signal values. Each of the four channels integrates dual-threshold trigger circuitry with windowed coincidence features. Channels can discriminate signals with ~1mV RMS resolution at >600 MHz bandwidth.