Normalized to: Che, G.
[1]
oai:arXiv.org:1710.11335 [pdf] - 1590508
A Superconducting Phase Shifter and Traveling Wave Kinetic Inductance
Parametric Amplifier for W-Band Astronomy
Che, George;
Gordon, Samuel;
Day, Peter;
Groppi, Christopher;
Jackson, Rebecca;
Mani, Hamdi;
Mauskopf, Philip;
Surdi, Harshad;
Trichopoulos, Georgios;
Underhill, Matthew
Submitted: 2017-10-31
The W-Band ($75-110\; \mathrm{GHz}$) sky contains a plethora of information
about star formation, galaxy evolution and the cosmic microwave background. We
have designed and fabricated a dual-purpose superconducting circuit to
facilitate the next generation of astronomical observations in this regime by
providing proof-of-concept for both a millimeter-wave low-loss phase shifter,
which can operate as an on-chip Fourier transform spectrometer (FTS) and a
traveling wave kinetic inductance parametric amplifier (TKIP). Superconducting
transmission lines have a propagation speed that depends on the inductance in
the line which is a combination of geometric inductance and kinetic inductance
in the superconductor. The kinetic inductance has a non-linear component with a
characteristic current, $I_*$, and can be modulated by applying a DC current,
changing the propagation speed and effective path length. Our test circuit is
designed to measure the path length difference or phase shift, $\Delta \phi$,
between two symmetric transmission lines when one line is biased with a DC
current. To provide a measurement of $\Delta\phi$, a key parameter for
optimizing a high gain W-Band TKIP, and modulate signal path length in FTS
operation, our $3.6 \times 2.5\; \mathrm{cm}$ chip employs a pair of $503\;
\mathrm{mm}$ long NbTiN inverted microstrip lines coupled to circular waveguide
ports through radial probes. For a line of width $3\; \mathrm{\mu m}$ and film
thickness $20\; \mathrm{nm}$, we predict $\Delta\phi\approx1767\; \mathrm{rad}$
at $90\; \mathrm{GHz}$ when biased at close to $I_*$. We have fabricated a
prototype with $200\; \mathrm{nm}$ thick Nb film and the same line length and
width. The predicted phase shift for our prototype is $\Delta\phi\approx30\;
\mathrm{rad}$ at $90\; \mathrm{GHz}$ when biased at close to $I_*$ for Nb.
[2]
oai:arXiv.org:1510.06609 [pdf] - 1579736
Photon noise from chaotic and coherent millimeter-wave sources measured
with horn-coupled, aluminum lumped-element kinetic inductance detectors
Flanigan, Daniel;
McCarrick, Heather;
Jones, Glenn;
Johnson, Bradley R.;
Abitbol, Maximilian H.;
Ade, Peter;
Araujo, Derek;
Bradford, Kristi;
Cantor, Robin;
Che, George;
Day, Peter K.;
Doyle, Simon;
Kjellstrand, Carl Bjorn;
LeDuc, Henry G;
Limon, Michele;
Luu, Vy;
Mauskopf, Philip;
Miller, Amber;
Mroczkowski, Tony;
Tucker, Carole;
Zmuidzinas, Jonas
Submitted: 2015-10-22, last modified: 2017-05-24
We report photon-noise limited performance of horn-coupled, aluminum
lumped-element kinetic inductance detectors at millimeter wavelengths. The
detectors are illuminated by a millimeter-wave source that uses an active
multiplier chain to produce radiation between 140 and 160 GHz. We feed the
multiplier with either amplified broadband noise or a continuous-wave tone from
a microwave signal generator. We demonstrate that the detector response over a
40 dB range of source power is well-described by a simple model that considers
the number of quasiparticles. The detector noise-equivalent power (NEP) is
dominated by photon noise when the absorbed power is greater than approximately
1 pW, which corresponds to $\mathrm{NEP} \approx 2 \times 10^{-17} \,
\mathrm{W} \, \mathrm{Hz}^{-1/2}$, referenced to absorbed power. At higher
source power levels we observe the relationships between noise and power
expected from the photon statistics of the source signal: $\mathrm{NEP} \propto
P$ for broadband (chaotic) illumination and $\mathrm{NEP} \propto P^{1/2}$ for
continuous-wave (coherent) illumination.
[3]
oai:arXiv.org:1608.05456 [pdf] - 1459468
Instrumental performance and results from testing of the BLAST-TNG
receiver, submillimeter optics, and MKID arrays
Galitzki, Nicholas;
Ade, Peter;
Angile, Francesco E.;
Ashton, Peter;
Austermann, Jason;
Billings, Tashalee;
Che, George;
Cho, Hsiao-Mei;
Davis, Kristina;
Devlin, Mark;
Dicker, Simon;
Dober, Bradley J.;
Fissel, Laura M.;
Fukui, Yasuo;
Gao, Jiansong;
Gordon, Samuel;
Groppi, Christopher E.;
Hillbrand, Seth;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Klein, Jeffrey;
Li, Dale;
Li, Zhi-Yun;
Lourie, Nathan P.;
Lowe, Ian;
Mani, Hamdi;
Martin, Peter G.;
Mauskopf, Philip;
McKenney, Christopher;
Nati, Federico;
Novak, Giles;
Pascale, Enzo;
Pisano, Giampaolo;
Santos, Fabio P.;
Scott, Douglas;
Sinclair, Adrian;
Soler, Juan D.;
Tucker, Carole;
Underhill, Matthew;
Vissers, Michael;
Williams, Paul
Submitted: 2016-08-18
Polarized thermal emission from interstellar dust grains can be used to map
magnetic fields in star forming molecular clouds and the diffuse interstellar
medium (ISM). The Balloon-borne Large Aperture Submillimeter Telescope for
Polarimetry (BLASTPol) flew from Antarctica in 2010 and 2012 and produced
degree-scale polarization maps of several nearby molecular clouds with
arcminute resolution. The success of BLASTPol has motivated a next-generation
instrument, BLAST-TNG, which will use more than 3000 linear polarization
sensitive microwave kinetic inductance detectors (MKIDs) combined with a 2.5m
diameter carbon fiber primary mirror to make diffraction-limited observations
at 250, 350, and 500 $\mu$m. With 16 times the mapping speed of BLASTPol,
sub-arcminute resolution, and a longer flight time, BLAST-TNG will be able to
examine nearby molecular clouds and the diffuse galactic dust polarization
spectrum in unprecedented detail. The 250 $\mu$m detector array has been
integrated into the new cryogenic receiver, and is undergoing testing to
establish the optical and polarization characteristics of the instrument.
BLAST-TNG will demonstrate the effectiveness of kilo-pixel MKID arrays for
applications in submillimeter astronomy. BLAST-TNG is scheduled to fly from
Antarctica in December 2017 for 28 days and will be the first balloon-borne
telescope to offer a quarter of the flight for "shared risk" observing by the
community.
[4]
oai:arXiv.org:1607.03448 [pdf] - 1531012
Development of dual-polarization LEKIDs for CMB observations
McCarrick, Heather;
Abitbol, Maximilian H.;
Ade, Peter A. R.;
Barry, Peter;
Bryan, Sean;
Che, George;
Day, Peter;
Doyle, Simon;
Flanigan, Daniel;
Johnson, Bradley R.;
Jones, Glenn;
LeDuc, Henry G.;
Limon, Michele;
Mauskopf, Philip;
Miller, Amber;
Tucker, Carole;
Zmuidzinas, Jonas
Submitted: 2016-07-12
We discuss the design considerations and initial measurements from arrays of
dual-polarization, lumped element kinetic inductance detectors (LEKIDs)
nominally designed for cosmic microwave background (CMB) studies. The detectors
are horn-coupled, and each array element contains two single-polarization
LEKIDs, which are made from thin-film aluminum and optimized for a single
spectral band centered on 150 GHz. We are developing two array architectures,
one based on 160 micron thick silicon wafers and the other based on
silicon-on-insulator (SOI) wafers with a 30 micron thick device layer. The
20-element test arrays (40 LEKIDs) are characterized with both a
linearly-polarized electronic millimeter wave source and a thermal source. We
present initial measurements including the noise spectra, noise-equivalent
temperature, and responsivity. We discuss future testing and further design
optimizations to be implemented.
[5]
oai:arXiv.org:1603.02963 [pdf] - 1371678
Optical Demonstration of THz, Dual-Polarization Sensitive Microwave
Kinetic Inductance Detectors
Dober, B.;
Austermann, J. A.;
Beall, J. A.;
Becker, D.;
Che, G.;
Cho, H. M.;
Devlin, M.;
Duff, S. M.;
Galitzki, N.;
Gao, J.;
Groppi, C.;
Hilton, G. C.;
Hubmayr, J.;
Irwin, K. D.;
McKenney, C. M.;
Li, D.;
Lourie, N.;
Mauskopf, P.;
Vissers, M. R.;
Wang, Y.
Submitted: 2016-03-09
The next generation BLAST experiment (BLAST-TNG) is a suborbital balloon
payload that seeks to map polarized dust emission in the 250 $\mu$m, 350 $\mu$m
and 500 $\mu$m wavebands. The instrument utilizes a stepped half-wave plate to
reduce systematics. The general requirement of the detectors is that they are
photon-noise-limited and dual-polarization sensitive. To achieve this goal, we
are developing three monolithic arrays of cryogenic sensors, one for each
waveband. Each array is feedhorn-coupled and each spatial pixel consists of two
orthogonally spaced polarization-sensitive microwave kinetic inductance
detectors (MKIDs) fabricated from a Ti/TiN multilayer film. In previous work,
we demonstrated photon-noise-limited sensitivity in 250 $\mu$m waveband single
polarization devices. In this work, we present the first results of
dual-polarization sensitive MKIDs at 250 $\mu$m.
[6]
oai:arXiv.org:1512.01847 [pdf] - 1347758
A Titanium Nitride Absorber for Controlling Optical Crosstalk in
Horn-Coupled Aluminum LEKID Arrays for Millimeter Wavelengths
McCarrick, H.;
Flanigan, D.;
Jones, G.;
Johnson, B. R.;
Ade, P. A. R.;
Bradford, K.;
Bryan, S.;
Cantor, R.;
Che, G.;
Day, P.;
Doyle, S.;
Leduc, H.;
Limon, M.;
Mauskopf, P.;
Miller, A.;
Mroczkowski, T.;
Tucker, C.;
Zmuidzinas, J.
Submitted: 2015-12-06
We discuss the design and measured performance of a titanium nitride (TiN)
mesh absorber we are developing for controlling optical crosstalk in
horn-coupled lumped-element kinetic inductance detector arrays for
millimeter-wavelengths. This absorber was added to the fused silica
anti-reflection coating attached to previously-characterized, 20-element
prototype arrays of LEKIDs fabricated from thin-film aluminum on silicon
substrates. To test the TiN crosstalk absorber, we compared the measured
response and noise properties of LEKID arrays with and without the TiN mesh.
For this test, the LEKIDs were illuminated with an adjustable, incoherent
electronic millimeter-wave source. Our measurements show that the optical
crosstalk in the LEKID array with the TiN absorber is reduced by 66\% on
average, so the approach is effective and a viable candidate for future
kilo-pixel arrays.
[7]
oai:arXiv.org:1511.04488 [pdf] - 1347622
Low Noise Titanium Nitride KIDs for SuperSpec: A Millimeter-Wave On-Chip
Spectrometer
Hailey-Dunsheath, S.;
Shirokoff, E.;
Barry, P. S.;
Bradford, C. M.;
Chapman, S.;
Che, G.;
Glenn, J.;
Hollister, M.;
Kovács, A.;
LeDuc, H. G.;
Mauskopf, P.;
McKenney, C.;
O'Brient, R.;
Padin, S.;
Reck, T.;
Shiu, C.;
Tucker, C. E.;
Wheeler, J.;
Williamson, R.;
Zmuidzinas, J.
Submitted: 2015-11-13
SuperSpec is a novel on-chip spectrometer we are developing for multi-object,
moderate resolution (R = 100 - 500), large bandwidth (~1.65:1) submillimeter
and millimeter survey spectroscopy of high-redshift galaxies. The spectrometer
employs a filter bank architecture, and consists of a series of half-wave
resonators formed by lithographically-patterned superconducting transmission
lines. The signal power admitted by each resonator is detected by a lumped
element titanium nitride (TiN) kinetic inductance detector (KID) operating at
100 - 200 MHz. We have tested a new prototype device that achieves the targeted
R = 100 resolving power, and has better detector sensitivity and optical
efficiency than previous devices. We employ a new method for measuring photon
noise using both coherent and thermal sources of radiation to cleanly separate
the contributions of shot and wave noise. We report an upper limit to the
detector NEP of $1.4\times10^{-17}$ W Hz$^{-1/2}$, within 10% of the photon
noise limited NEP for a ground-based R=100 spectrometer.
[8]
oai:arXiv.org:1509.04658 [pdf] - 1347523
WSPEC: A waveguide filter-bank focal plane array spectrometer for
millimeter wave astronomy and cosmology
Bryan, Sean;
Aguirre, James;
Che, George;
Doyle, Simon;
Flanigan, Daniel;
Groppi, Christopher;
Johnson, Bradley;
Jones, Glenn;
Mauskopf, Philip;
McCarrick, Heather;
Monfardini, Alessandro;
Mroczkowski, Tony
Submitted: 2015-09-15
Imaging and spectroscopy at (sub-)millimeter wavelengths are key frontiers in
astronomy and cosmology. Large area spectral surveys with moderate spectral
resolution (R=50-200) will be used to characterize large scale structure and
star formation through intensity mapping surveys in emission lines such as the
CO rotational transitions. Such surveys will also be used to study the SZ
effect, and will detect the emission lines and continuum spectrum of individual
objects. WSPEC is an instrument proposed to target these science goals. It is a
channelizing spectrometer realized in rectangular waveguide, fabricated using
conventional high-precision metal machining. Each spectrometer is coupled to
free space with a machined feed horn, and the devices are tiled into a 2D array
to fill the focal plane of the telescope. The detectors will be aluminum
Lumped-Element Kinetic Inductance Detectors (LEKIDs). To target the CO lines
and SZ effect, we will have bands at 135-175 GHz and 190-250 GHz, each
Nyquist-sampled at R~200 resolution. Here we discuss the instrument concept and
design, and successful initial testing of a WR10 (i.e. 90 GHz) prototype
spectrometer. We recently tested a WR5 (180 GHz) prototype to verify that the
concept works at higher frequencies, and also designed a resonant backshort
structure that may further increase the optical efficiency. We are making
progress towards integrating a spectrometer with a LEKID array and deploying a
prototype device to a telescope for first light.
[9]
oai:arXiv.org:1502.02735 [pdf] - 1264646
A Compact Filter-Bank Waveguide Spectrometer for Millimeter Wavelengths
Submitted: 2015-02-09, last modified: 2015-05-13
We present the design and measurements of a 90GHz prototype of a
millimeter-wave channelizing spectrometer realized in rectangular waveguide for
astronomical instrumentation. The device was fabricated using conventional
high-precision metal machining, and the spectrometer can be tiled into a 2D
array to fill the focal plane of a telescope. Measurements of the fabricated
five-channel device matched well with electromagnetic simulations using HFSS
and a cascaded S-matrix approach. This motivated the design of a 54-channel
R=200 spectrometer that fills the single-moded passband of rectangular
waveguide in the 130-175 GHz and 190-250 GHz atmospheric windows for
millimeter-wave spectroscopic mapping and multi-object spectroscopy.
[10]
oai:arXiv.org:1407.7749 [pdf] - 971383
Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic
Inductance Detectors for Millimeter Wavelengths
McCarrick, H.;
Flanigan, D.;
Jones, G.;
Johnson, B. R.;
Ade, P.;
Araujo, D.;
Bradford, K.;
Cantor, R.;
Che, G.;
Day, P.;
Doyle, S.;
Leduc, H.;
Limon, M.;
Luu, V.;
Mauskopf, P.;
Miller, A.;
Mroczkowski, T.;
Tucker, C.;
Zmuidzinas, J.
Submitted: 2014-07-29, last modified: 2015-03-26
We discuss the design, fabrication, and testing of prototype horn-coupled,
lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic
microwave background (CMB) studies. The LEKIDs are made from a thin aluminum
film deposited on a silicon wafer and patterned using standard
photolithographic techniques at STAR Cryoelectronics, a commercial device
foundry. We fabricated twenty-element arrays, optimized for a spectral band
centered on 150 GHz, to test the sensitivity and yield of the devices as well
as the multiplexing scheme. We characterized the detectors in two
configurations. First, the detectors were tested in a dark environment with the
horn apertures covered, and second, the horn apertures were pointed towards a
beam-filling cryogenic blackbody load. These tests show that the multiplexing
scheme is robust and scalable, the yield across multiple LEKID arrays is 91%,
and the noise-equivalent temperatures (NET) for a 4 K optical load are in the
range 26$\thinspace\pm6 \thinspace \mu \mbox{K} \sqrt{\mbox{s}}$.
[11]
oai:arXiv.org:1503.06528 [pdf] - 969448
WSPEC: A Waveguide Filter Bank Spectrometer
Che, George;
Bryan, Sean;
Underhill, Matthew;
Mauskopf, Philip;
Groppi, Christopher;
Jones, Glenn;
Johnson, Bradley;
McCarrick, Heather;
Flanigan, Daniel;
Day, Peter
Submitted: 2015-03-23
We have designed, fabricated, and measured a 5-channel prototype spectrometer
pixel operating in the WR10 band to demonstrate a novel moderate-resolution
(R=f/{\Delta}f~100), multi-pixel, broadband, spectrometer concept for mm and
submm-wave astronomy. Our design implements a transmission line filter bank
using waveguide resonant cavities as a series of narrow-band filters, each
coupled to an aluminum kinetic inductance detector (KID). This technology has
the potential to perform the next generation of spectroscopic observations
needed to drastically improve our understanding of the epoch of reionization
(EoR), star formation, and large-scale structure of the universe. We present
our design concept, results from measurements on our prototype device, and the
latest progress on our efforts to develop a 4-pixel demonstrator instrument
operating in the 130-250 GHz band.
[12]
oai:arXiv.org:1503.04684 [pdf] - 957156
Design of Dual-Polarization Horn-Coupled Kinetic Inductance Detectors
for Cosmic Microwave Background Polarimetry
Bryan, Sean;
Bradford, Kristi;
Che, George;
Day, Peter;
Flanigan, Daniel;
Johnson, Bradley R.;
Jones, Glenn;
Kjellstrand, Bjorn;
Limon, Michele;
Mauskopf, Philip;
McCarrick, Heather;
Miller, Amber;
Smiley, Brian
Submitted: 2015-03-16
Mapping the polarization of the Cosmic Microwave Background is yielding
exciting data on the origin of the universe, the reionization of the universe,
and the growth of cosmic structure. Kilopixel arrays represent the current
state of the art, but advances in detector technology are needed to enable the
larger detector arrays needed for future measurements. Here we present a design
for single-band dual-polarization Kinetic Inductance Detectors (KIDs) at 20%
bandwidths centered at 145, 220, and 280 GHz. The detection and readout system
is nearly identical to the successful photon-noise-limited aluminum
Lumped-Element KIDs that have been recently built and tested by some of the
authors. Fabricating large focal plane arrays of the feed horns and
quarter-wave backshorts requires only conventional precision machining. Since
the detectors and readout lines consist only of a single patterned aluminum
layer on a SOI wafer, arrays of the detectors can be built commercially or at a
standard university cleanroom.
[13]
oai:arXiv.org:1409.7084 [pdf] - 896558
The Next Generation BLAST Experiment
Galitzki, Nicholas;
Ade, Peter A. R.;
Angilè, Francesco E.;
Ashton, Peter;
Beall, James A.;
Becker, Dan;
Bradford, Kristi J.;
Che, George;
Cho, Hsiao-Mei;
Devlin, Mark J.;
Dober, Bradley J.;
Fissel, Laura M.;
Fukui, Yasuo;
Gao, Jiansong;
Groppi, Christopher E.;
Hillbrand, Seth;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Klein, Jeffrey;
Van Lanen, Jeff;
Li, Dale;
Li, Zhi-Yun;
Lourie, Nathan P.;
Mani, Hamdi;
Martin, Peter G.;
Mauskopf, Philip;
Nakamura, Fumitaka;
Novak, Giles;
Pappas, David P.;
Pascale, Enzo;
Pisano, Giampaolo;
Santos, Fabio P.;
Savini, Giorgio;
Scott, Douglas;
Stanchfield, Sara;
Tucker, Carole;
Ullom, Joel N.;
Underhill, Matthew;
Vissers, Michael R.;
Ward-Thompson, Derek
Submitted: 2014-09-24, last modified: 2014-11-12
The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry
(BLASTPol) was a suborbital experiment designed to map magnetic fields in order
to study their role in star formation processes. BLASTPol made detailed
polarization maps of a number of molecular clouds during its successful flights
from Antarctica in 2010 and 2012. We present the next-generation BLASTPol
instrument (BLAST-TNG) that will build off the success of the previous
experiment and continue its role as a unique instrument and a test bed for new
technologies. With a 16-fold increase in mapping speed, BLAST-TNG will make
larger and deeper maps. Major improvements include a 2.5 m carbon fiber mirror
that is 40% wider than the BLASTPol mirror and ~3000 polarization sensitive
detectors. BLAST-TNG will observe in three bands at 250, 350, and 500 microns.
The telescope will serve as a pathfinder project for microwave kinetic
inductance detector (MKID) technology, as applied to feedhorn coupled
submillimeter detector arrays. The liquid helium cooled cryostat will have a
28-day hold time and will utilize a closed-cycle $^3$He refrigerator to cool
the detector arrays to 270 mK. This will enable a detailed mapping of more
targets with higher polarization resolution than any other submillimeter
experiment to date. BLAST-TNG will also be the first balloon-borne telescope to
offer shared risk observing time to the community. This paper outlines the
motivation for the project and the instrumental design.
[14]
oai:arXiv.org:1407.6249 [pdf] - 880220
A LEKID-based CMB instrument design for large-scale observations in
Greenland
Araujo, D. C.;
Ade, P. A. R.;
Bond, J. R.;
Bradford, K. J.;
Chapman, D.;
Che, G.;
Day, P. K.;
Didier, J.;
Doyle, S.;
Eriksen, H. K.;
Flanigan, D.;
Groppi, C. E.;
Hillbrand, S. N.;
Johnson, B. R.;
Jones, G.;
Limon, M.;
Miller, A. D.;
Mauskopf, P.;
McCarrick, H.;
Mroczkowski, T.;
Reichborn-Kjennerud, B.;
Smiley, B.;
Sobrin, J.;
Wehus, I. K.;
Zmuidzinas, J.
Submitted: 2014-07-10, last modified: 2014-10-10
We present the results of a feasibility study, which examined deployment of a
ground-based millimeter-wave polarimeter, tailored for observing the cosmic
microwave background (CMB), to Isi Station in Greenland. The instrument for
this study is based on lumped-element kinetic inductance detectors (LEKIDs) and
an F/2.4 catoptric, crossed-Dragone telescope with a 500 mm aperture. The
telescope is mounted inside the receiver and cooled to $<\,4$ K by a
closed-cycle $^4$He refrigerator to reduce background loading on the detectors.
Linearly polarized signals from the sky are modulated with a metal-mesh
half-wave plate that is rotated at the aperture stop of the telescope with a
hollow-shaft motor based on a superconducting magnetic bearing. The modular
detector array design includes at least 2300 LEKIDs, and it can be configured
for spectral bands centered on 150~GHz or greater. Our study considered
configurations for observing in spectral bands centered on 150, 210 and
267~GHz. The entire polarimeter is mounted on a commercial precision rotary air
bearing, which allows fast azimuth scan speeds with negligible vibration and
mechanical wear over time. A slip ring provides power to the instrument,
enabling circular scans (360 degrees of continuous rotation). This mount, when
combined with sky rotation and the latitude of the observation site, produces a
hypotrochoid scan pattern, which yields excellent cross-linking and enables
34\% of the sky to be observed using a range of constant elevation scans. This
scan pattern and sky coverage combined with the beam size (15~arcmin at
150~GHz) makes the instrument sensitive to $5 < \ell < 1000$ in the angular
power spectra.
[15]
oai:arXiv.org:1407.3756 [pdf] - 1215656
The next-generation BLASTPol experiment
Dober, Bradley;
Ade, Peter A. R.;
Ashton, Peter;
Angilè, Francesco E.;
Beall, James A.;
Becker, Dan;
Bradford, Kristi J.;
Che, George;
Cho, Hsiao-Mei;
Devlin, Mark J.;
Fissel, Laura M.;
Fukui, Yasuo;
Galitzki, Nicholas;
Gao, Jiansong;
Groppi, Christopher E.;
Hillbrand, Seth;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Klein, Jeffrey;
Van Lanen, Jeff;
Li, Dale;
Li, Zhi-Yun;
Lourie, Nathan P.;
Mani, Hamdi;
Martin, Peter G.;
Mauskopf, Philip;
Nakamura, Fumitaka;
Novak, Giles;
Pappas, David P.;
Pascale, Enzo;
Santos, Fabio P.;
Savini, Giorgio;
Scott, Douglas;
Stanchfield, Sara;
Ullom, Joel N.;
Underhill, Matthew;
Vissers, Michael R.;
Ward-Thompson, Derek
Submitted: 2014-07-14
The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry
(BLASTPol) is a suborbital mapping experiment designed to study the role
magnetic fields play in star formation. BLASTPol has had two science flights
from McMurdo Station, Antarctica in 2010 and 2012. These flights have produced
thousands of polarization vectors at 250, 350 and 500 microns in several
molecular cloud targets. We present the design, specifications, and progress
towards the next-generation BLASTPol experiment (BLAST-TNG). BLAST-TNG will fly
a 40% larger diameter primary mirror, with almost 8 times the number of
polarization-sensitive detectors resulting in a factor of 16 increase in
mapping speed. With a spatial resolution of 22 arcseconds and four times the
field of view of BLASTPol, BLAST-TNG will bridge the angular scales between
Planck's low resolution all-sky maps and ALMA's ultra-high resolution narrow
fields. The new receiver has a larger cryogenics volume, allowing for a 28 day
hold time. BLAST-TNG employs three arrays of Microwave Kinetic Inductance
Detectors (MKIDs) with 30% fractional bandwidth at 250, 350 and 500 microns. In
this paper, we will present the new BLAST-TNG instrument and science
objectives.