sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Chardin, G.

Normalized to: Chardin, G.

28 article(s) in total. 191 co-authors, from 1 to 21 common article(s). Median position in authors list is 6,5.

[1]  oai:arXiv.org:1804.03067  [pdf] - 1794687
Cosmological structure formation with negative mass
Comments: Equation 14 has been corrected (NB: typo in the published PRD version)
Submitted: 2018-04-09, last modified: 2018-12-10
We construct a family of models with negative gravitational mass in the context of Newtonian gravity. We focus in particular on a model that reproduces the features of the so-called Dirac-Milne universe, a matter-antimatter symmetric universe that was recently proposed as an alternative cosmological scenario [A. Benoit-Levy and G. Chardin, A&A 537, A78 (2012)]. We perform one-dimensional N-body simulations of these negative-mass models for an expanding universe and study the associated formation of gravitational structures. The similarities and differences with the standard cosmological model are highlighted and discussed.
[2]  oai:arXiv.org:1110.3054  [pdf] - 482503
Introducing the Dirac-Milne universe
Comments: Replaced to match published version
Submitted: 2011-10-13, last modified: 2012-02-29
The \Lambda CDM standard model, although an excellent parametrization of the present cosmological data, requires two as yet unobserved components, Dark Matter and Dark Energy, for more than 95% of the Universe. Faced to this unsatisfactory situation, we study an unconventional cosmology, the Dirac-Milne universe, a matter-antimatter symmetric cosmology, in which antimatter is supposed to present a negative active gravitational mass. The main feature of this cosmology is the linear evolution of the scale factor with time which directly solves the age and horizon problems of a matter-dominated universe. We study the concordance of this model to the cosmological test of Type Ia Supernov\ae\ distance measurements and calculate the theoretical primordial abundances of light elements for this cosmology. We also show that the acoustic scale of the Cosmic Microwave Background naturally emerges at the degree scale despite an open geometry.
[3]  oai:arXiv.org:1103.4070  [pdf] - 966535
Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes
Comments: 23 pages, 5 figures; matches published version
Submitted: 2011-03-21, last modified: 2011-08-31
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and charge collection electrodes with an interleaved geometry enables the efficient rejection of gamma-induced radioactivity as well as near-surface interactions. A total effective exposure of 384 kg.d has been achieved, mostly coming from fourteen months of continuous operation. Five nuclear recoil candidates are observed above 20 keV, while the estimated background is 3.0 events. The result is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints are also set on models where the WIMP-nucleon scattering is inelastic.
[4]  oai:arXiv.org:1105.3377  [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS; Collaborations, EDELWEISS; :; Ahmed, Z.; Akerib, D. S.; Armengaud, E.; Arrenberg, S.; Augier, C.; Bailey, C. N.; Balakishiyeva, D.; Baudis, L.; Bauer, D. A.; Benoît, A.; Bergé, L.; Blümer, J.; Brink, P. L.; Broniatowski, A.; Bruch, T.; Brudanin, V.; Bunker, R.; Cabrera, B.; Caldwell, D. O.; Censier, B.; Chapellier, M.; Chardin, G.; Charlieux, F.; Cooley, J.; Coulter, P.; Cox, G. A.; Cushman, P.; Daal, M.; Defay, X.; De Jesus, M.; DeJongh, F.; Di Stefano, P. C. F.; Dolgorouki, Y.; Domange, J.; Dumoulin, L.; Dragowsky, M. R.; Eitel, K.; Fallows, S.; Figueroa-Feliciano, E.; Filippini, J.; Filosofov, D.; Fourches, N.; Fox, J.; Fritts, M.; Gascon, J.; Gerbier, G.; Gironnet, J.; Golwala, S. R.; Gros, M.; Hall, J.; Hennings-Yeomans, R.; Henry, S.; Hertel, S. A.; Hervé, S.; Holmgren, D.; Hsu, L.; Huber, M. E.; Juillard, A.; Kamaev, O.; Kiveni, M.; Kluck, H.; Kos, M.; Kozlov, V.; Kraus, H.; Kudryavtsev, V. A.; Leman, S. W.; Liu, S.; Loaiza, P.; Mahapatra, R.; Mandic, V.; Marnieros, S.; Martinez, C.; McCarthy, K. A.; Mirabolfathi, N.; Moore, D.; Nadeau, P.; Navick, X-F.; Nelson, H.; Nones, C.; Ogburn, R. W.; Olivieri, E.; Pari, P.; Pattavina, L.; Paul, B.; Phipps, A.; Pyle, M.; Qiu, X.; Rau, W.; Reisetter, A.; Ricci, Y.; Robinson, M.; Rozov, S.; Saab, T.; Sadoulet, B.; Sander, J.; Sanglard, V.; Schmidt, B.; Schnee, R. W.; Scorza, S.; Seitz, D. N.; Semikh, S.; Serfass, B.; Sundqvist, K. M.; Tarka, M.; Torrento-Coello, A. S.; Vagneron, L.; Verdier, M. -A.; Walker, R. J.; Wikus, P.; Yakushev, E.; Yellin, S.; Yoo, J.; Young, B. A.; Zhang, J.
Comments: Events, efficiencies, and main limit are available in text format (see README.txt)
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.
[5]  oai:arXiv.org:1006.3098  [pdf] - 190656
A detection system to measure muon-induced neutrons for direct Dark Matter searches
Comments: Accepted for publication in Astroparticle Physics; 14 pages, 10 figures
Submitted: 2010-06-15
Muon-induced neutrons constitute a prominent background component in a number of low count rate experiments, namely direct searches for Dark Matter. In this work we describe a neutron detector to measure this background in an underground laboratory, the Laboratoire Souterrain de Modane. The system is based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of the EDELWEISS-II experiment for coincident muon detection. The system was installed in autumn 2008 and passed since then a number of commissioning tests proving its full functionality. The data-taking is continuously ongoing and a count rate of the order of 1 muon-induced neutron per day has been achieved.
[6]  oai:arXiv.org:1001.4383  [pdf] - 33100
Monitoring of the thermal neutron flux in the LSM underground laboratory
Comments: submitted to Journal of Physics G: Nuclear and Particle Physics, 8 pages, 4 figures
Submitted: 2010-01-25
This paper describes precise measurements of the thermal neutron flux in the LSM underground laboratory in proximity of the EDELWEISS-II dark matter search experiment together with short measurements at various other locations. Monitoring of the flux of thermal neutrons is accomplished using a mobile detection system with low background proportional counter filled with $^3$He. On average 75 neutrons per day are detected with a background level below 1 count per day (cpd). This provides a unique possibility of a day by day study of variations of the neutron field in a deep underground site. The measured average 4$\pi$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is $\Phi_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We report the first experimental observation that the point-to-point thermal neutron flux at LSM varies by more than a factor two.
[7]  oai:arXiv.org:0912.0805  [pdf] - 157860
First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes
Comments: 14 pages, 3 figures. Submitted to Phys Lett. B
Submitted: 2009-12-04
The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effective exposure of 144 kgd is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80 GeV/c2. This result demonstrates for the first time the very high background rejection capabilities of these simple and robust detectors in an actual WIMP search experiment.
[8]  oai:arXiv.org:0905.0753  [pdf] - 369040
A new high-background-rejection dark matter Ge cryogenic detector
Comments: submitted to Physical Review Letters
Submitted: 2009-05-06
A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices in the EDELWEISS II setup at the Modane underground facility demonstrate the remarkably high efficiency of these devices for the rejection of low-energy $\beta$, approaching 10$^5$ . This opens the road to investigate the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as proposed in the EURECA project of a one-ton cryogenic detector mass.
[9]  oai:arXiv.org:0903.2446  [pdf] - 22363
Do we live in a "Dirac-Milne" universe?
Comments: 4 pages
Submitted: 2009-03-13
The LCDM standard model, although an excellent parametrization of the present cosmological data, requires two as yet unobserved components, Dark Matter and Dark Energy, for more than 95% of the Universe, and a high level of fine-tuning. Faced to this unsatisfactory situation, we study an unconventional cosmology, the Dirac-Milne universe, a matter-antimatter symmetric cosmology, in which antimatter is supposed to present a negative active gravitational mass. We show that this universe remarkably satisfies the cosmological tests for the age of the Universe, Big-Bang Nucleosynthesis, and Type Ia Supernovae data. Most surprisingly, it also provides the degree scale for the first acoustic peak of the Cosmological Microwave Background. This simple model, without any adjustable parameter or need for Dark Matter or Dark Energy, is a reminder that we should look for simpler and more motivated cosmological models than the present LCDM standard model.
[10]  oai:arXiv.org:0811.2149  [pdf] - 18510
Observational constraints of a Milne Universe
Comments: Proceedings of the 43rd Rencontres de Moriond 2008
Submitted: 2008-11-13
The Standard Model of cosmology states a surprising composition of the Universe, in which ordinary matter accounts for less than 5%. The remaining 95% are composed of ~70% Dark Energy and ~25% Dark Matter. However, those two components have never been identified and remain a challenging problem to modern cosmology. One alternative to the concordance model could be the symmetric Milne universe, composed of matter and antimatter (supposed to have negative mass) in equal quantities. We will present the effects of these hypothesis on classical cosmological tests such as primordial nucleosynthesis, CMB, or Type Ia supernovae and show that this model is in remarkably good agreement with observations.
[11]  oai:arXiv.org:0804.4199  [pdf] - 12107
Gravitation, C, P and T symmetries and the Second Law
Comments: 9 pages, two figures, invited contribution at the "Quantum Limits to the Second Law" conference (San Diego, 2002)
Submitted: 2008-04-25
The intimate links between gravitation and the second law are summarized and two less known relations between gravity and thermodynamics are studied. Firstly, the information cost required to operate a Maxwell's demon on a curved spacetime is estimated using the Kolmogorov-Sinai entropy. More importantly, the charge and time (C and T) reversal properties of the Kerr-Newman solution in General relativity show that this solution, similarly to the Dirac equation, appears to represent both a particle and its antiparticle and suggests a definition of antimatter in general relativity. This definition leads to a parameter free explanation of the cosmological constant term observed in the supernovae data. The relation of this definition of antimatter with the coupled systems through opposite time arrows studied by Schulman is also emphasized.
[12]  oai:arXiv.org:astro-ph/0610821  [pdf] - 86245
Identification of backgrounds in the EDELWEISS-I dark matter search experiment
Comments:
Submitted: 2006-10-27, last modified: 2007-05-10
This paper presents our interpretation and understanding of the different backgrounds in the EDELWEISS-I data sets. We analyze in detail the several populations observed, which include gammas, alphas, neutrons, thermal sensor events and surface events, and try to combine all data sets to provide a coherent picture of the nature and localisation of the background sources. In light of this interpretation, we draw conclusions regarding the background suppression scheme for the EDELWEISS-II phase.
[13]  oai:arXiv.org:astro-ph/0607502  [pdf] - 83705
Measurement of the response of heat-and-ionization germanium detectors to nuclear recoils
Comments: 28 pages, 7 figures. Submitted to Phys. Rev. D
Submitted: 2006-07-21
The heat quenching factor Q' (the ratio of the heat signals produced by nuclear and electron recoils of equal energy) of the heat-and-ionization germanium bolometers used by the EDELWEISS collaboration has been measured. It is explained how this factor affects the energy scale and the effective quenching factor observed in calibrations with neutron sources. This effective quenching effect is found to be equal to Q/Q', where Q is the quenching factor of the ionization yield. To measure Q', a precise EDELWEISS measurement of Q/Q' is combined with values of Q obtained from a review of all available measurements of this quantity in tagged neutron beam experiments. The systematic uncertainties associated with this method to evaluate Q' are discussed in detail. For recoil energies between 20 and 100 keV, the resulting heat quenching factor is Q' = 0.91+-0.03+-0.04, where the two errors are the contributions from the Q and Q/Q' measurements, respectively. The present compilation of Q values and evaluation of Q' represent one of the most precise determinations of the absolute energy scale for any detector used in direct searches for dark matter.
[14]  oai:arXiv.org:astro-ph/0512120  [pdf] - 78320
Critical revision of the ZEPLIN-I sensitivity to WIMP interactions
Comments: 8 pages, 4 figures, minor corrections, two references updated, final version accepted in Physics Letters B
Submitted: 2005-12-05, last modified: 2006-04-19
The ZEPLIN collaboration has recently published its first result presenting a maximum sensitivity of $1.1 \times 10^{-6}$ picobarn for a WIMP mass of $\approx$ 60 GeV. The analysis is based on a discrimination method using the different time distribution of scintillation light generated in electron recoil and nuclear recoil interactions. We show that the methodology followed both for the calibration of the ZEPLIN-I detector response and for the estimation of the discrimination power is not reliable enough to claim any background discrimination at the present stage. The ZEPLIN-I sensitivity appears then to be in the order of 10$^{-3}$ picobarn, three orders of magnitude above the claimed 1.1 10$^{-6}$ picobarn.
[15]  oai:arXiv.org:astro-ph/0503265  [pdf] - 71647
Final results of the EDELWEISS-I dark matter search with cryogenic heat-and-ionization Ge detectors
Comments: 42 pages, 16 figures, submitted to Physical Review D, 1 figure and 2 references added, some little changes in the text
Submitted: 2005-03-11, last modified: 2005-05-26
The final results of the EDELWEISS-I dark matter search using cryogenic heat-and-ionization Ge detectors are presented. The final data sample corresponds to an increase by a factor five in exposure relative to the previously published results. A recoil energy threshold of 13 keV or better was achieved with three 320g detectors working simultaneously over four months of stable operation. Limits on the spin-independent cross-section for the scattering of a WIMP on a nucleon are derived from an accumulated fiducial exposure of 62 kg.d.
[16]  oai:arXiv.org:astro-ph/0412061  [pdf] - 69465
Sensitivity of the EDELWEISS WIMP search to spin-dependent interactions
Comments: v2: new references and figures added, other minor changes. Accepted for publication in Physics Letters B
Submitted: 2004-12-02, last modified: 2005-04-19
The EDELWEISS collaboration is searching for WIMP dark matter using natural Ge cryogenic detectors. The whole data set of the first phase of the experiment contains a fiducial exposure of 4.8 kg.day on Ge-73, the naturally present (7.8%), high-spin Ge isotope. The sensitivity of the experiment to the spin-dependent WIMP-nucleon interactions is evaluated using the model-independent framework proposed by Tovey et al.
[17]  oai:arXiv.org:astro-ph/0411503  [pdf] - 1233439
Dark Matter Direct Detection
Comments: 46 pages, 17 figures, to appear in "Cryogenic Particle Detection", edited by Christian Enss, (Springer, Heidelberg, 2005) ; one figure and two references modified ; typographical corrections
Submitted: 2004-11-17, last modified: 2005-02-28
Solving the Dark Matter enigma represents one of the key objectives of contemporary physics. Recent astrophysical and cosmological measurements have unambiguously demonstrated that ordinary matter contributes to less than 5 % of the energy budget of our Universe, and that the nature of the remaining 95 % is unknown. Weakly Interacting Massive Particles (WIMPs) represent the best motivated candidate to fill the Dark Matter gap, and direct detection Dark Matter experiments have recently reached sensitivities allowing them to sample a first part of supersymmetric models compatible with accelerator constraints. Three cryogenic experiments currently provide the best sensitivity, by nearly one order of magnitude, to WIMP interactions. With systematic uncertainties far less severe than other present techniques, the next generation of cryogenic experiments promises two orders of magnitude increase in sensitivity over the next few years. The present results, perspectives and experimental strategies of the main direct detection experiments are presented. Challenges met by future ton-scale cryogenic experiments in deep underground sites, aiming at testing most of the SUSY parameter space, are critically discussed.
[18]  oai:arXiv.org:astro-ph/0310657  [pdf] - 60320
Calibration of the EDELWEISS Cryogenic Heat-and-ionisation Germanium Detectors for Dark Matter Search
Comments: 27 pages, Latex, 11 figures. Submitted to NIM A
Submitted: 2003-10-22
Several aspects of the analysis of the data obtained with the cryogenic heat-and-ionisation Ge detectors used by the EDELWEISS dark matter search experiment are presented. Their calibration, the determination of their energy threshold, fiducial volume and nuclear recoil acceptance are detailed.
[19]  oai:arXiv.org:astro-ph/0306134  [pdf] - 1591970
Status and Perspectives of Direct Dark Matter Searches
Comments:
Submitted: 2003-06-06, last modified: 2003-06-25
Supersymmetric particles represent the best motivated candidates to fill the Dark Matter gap, and are actively hunted by a number of competing experiments. Discriminating experiments are testing for the first time SUSY models compatible with accelerator constraints. These experiments contradict the 60 GeV WIMP candidate reported by the DAMA experiment. The sensitivities of direct and indirect detection techniques for both present experiments and future projects are compared.
[20]  oai:arXiv.org:astro-ph/0206271  [pdf] - 49902
Improved Exclusion Limits from the EDELWEISS WIMP Search
Comments: 14 pages, Latex, 5 figures. Submitted to Phys. Lett. B
Submitted: 2002-06-17
The EDELWEISS experiment has improved its sensitivity for the direct search for WIMP dark matter. In the recoil energy range relevant for WIMP masses below 10 TeV/c2, no nuclear recoils were observed in the fiducial volume of a heat-and-ionization cryogenic Ge detector operated in the low-background environment of the Laboratoire Souterrain de Modane in the Frejus Tunnel, during an effective exposure of 7.4 kg.days. This result is combined with the previous EDELWEISS data to derive a limit on the cross-section for spin-independent interaction of WIMPs and nucleons as a function of WIMP mass, using standard nuclear physics and astrophysical assumptions. This limit excludes at more than 99.8%CL a WIMP candidate with a mass of 44 GeV/c2 and a cross-section of 5.4 x 10-6 pb, as reported by the DAMA collaboration. A first sample of supersymmetric models are also excluded at 90%CL.
[21]  oai:arXiv.org:astro-ph/0205023  [pdf] - 49097
320g Ionization-Heat Cryogenic Detector for Dark Matter Search in the EDELWEISS Experiment
Comments: 4 pages, 3 figures
Submitted: 2002-05-02
The EDELWEISS experiment used in 2001 a 320g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane for direct WIMP detection. This detector presents an increase of more than 4 times the mass of previous detectors. Calibrations of this detector are used to determine its energy resolution and fiducial volume, and to optimize the detector design for the 1kg phase of the EDELWEISS-I experiment. Analysis of the calibrations and characteristics of a first series of 320g-detectors are presented.
[22]  oai:arXiv.org:astro-ph/0106094  [pdf] - 173739
First Results of the EDELWEISS WIMP Search using a 320 g Heat-and-Ionization Ge Detector
Comments: 14 pages, Latex, 4 figures. Submitted to Phys. Lett. B
Submitted: 2001-06-06
The EDELWEISS collaboration has performed a direct search for WIMP dark matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils are observed in the fiducial volume in the 30-200 keV energy range during an effective exposure of 4.53 kg.days. Limits for the cross-section for the spin-independent interaction of WIMPs and nucleons are set in the framework of the Minimal Supersymmetric Standard Model (MSSM). The central value of the signal reported by the experiment DAMA is excluded at 90% CL.
[23]  oai:arXiv.org:astro-ph/0104192  [pdf] - 1943551
Dark Matter Search in the EDELWEISS experiment
Comments: 4 pages, LaTeX, 3 figures, contribution to " Very High Energy Phenomena in the Universe ", Les Arcs, France (January 20-27, 2001)
Submitted: 2001-04-11
The EDELWEISS Dark Matter Search uses low-temperature Ge detectors with heat and ionisation read-out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Preliminary results obtained with 320g bolometers are described. After a few weeks of data taking, data accumulated with one of these detectors already allow to reach the upper part of the DAMA region. Prospects for the present run and the second stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data taking with 100 detectors, are briefly described.
[24]  oai:arXiv.org:astro-ph/0101204  [pdf] - 1507854
Dark Matter Search in the Edelweiss Experiment
Comments: IDM 2000, 3rd International Workshop on the Identification of Dark Matter, York (GB), 18-22/09/2000, v2.0 minor modifications
Submitted: 2001-01-12, last modified: 2001-02-23
Preliminary results obtained with 320g bolometers with simultaneous ionization and heat measurements are described. After a few weeks of data taking, data accumulated with one of these detectors are beginning to exclude the upper part of the DAMA region. Prospects for the present run and the second stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data taking with 100 detectors, are briefly described.
[25]  oai:arXiv.org:astro-ph/0101454  [pdf] - 40592
The EDELWEISS Experiment : Status and Outlook
Comments: International Conference on Dark Matter in Astro and Particle Physics (Dark 2000), Heidelberg, Germany, 10-16 Jul 2000, v3 minor revisions
Submitted: 2001-01-25, last modified: 2001-02-06
The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat and ionisation read- out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Results from the operation of 70 g and 320 g Ge detectors in the low-background environment of the Modane Underground Laboratory (LSM) are presented.
[26]  oai:arXiv.org:astro-ph/0004308  [pdf] - 35667
Background discrimination capabilities of a heat and ionization germanium cryogenic detector
Comments: Submitted to Astroparticle Physics, 14 pages
Submitted: 2000-04-21
The discrimination capabilities of a 70 g heat and ionization Ge bolometer are studied. This first prototype has been used by the EDELWEISS Dark Matter experiment, installed in the Laboratoire Souterrain de Modane, for direct detection of WIMPs. Gamma and neutron calibrations demonstrate that this type of detector is able to reject more than 99.6% of the background while retaining 95% of the signal, provided that the background events distribution is not biased towards the surface of the Ge crystal. However, the 1.17 kg.day of data taken in a relatively important radioactive environment show an extra population slightly overlapping the signal. This background is likely due to interactions of low energy photons or electrons near the surface of the crystal, and is somewhat reduced by applying a higher charge-collecting inverse bias voltage (-6 V instead of -2 V) to the Ge diode. Despite this contamination, more than 98% of the background can be rejected while retaining 50% of the signal. This yields a conservative upper limit of 0.7 event.day^{-1}.kg^{-1}.keV^{-1}_{recoil} at 90% confidence level in the 15-45 keV recoil energy interval; the present sensitivity appears to be limited by the fast ambient neutrons. Upgrades in progress on the installation are summarized.
[27]  oai:arXiv.org:astro-ph/0002462  [pdf] - 34805
Event categories in the EDELWEISS WIMP search experiment
Comments: 11 pages, submitted to Phys. Lett. B
Submitted: 2000-02-24
Four categories of events have been identified in the EDELWEISS-I dark matter experiment using germanium cryogenic detectors measuring simultaneously charge and heat signals. These categories of events are interpreted as electron and nuclear interactions occurring in the volume of the detector, and electron and nuclear interactions occurring close to the surface of the detectors(10-20 mu-m of the surface). We discuss the hypothesis that low energy surface nuclear recoils,which seem to have been unnoticed by previous WIMP searches, may provide an interpretation of the anomalous events recorded by the UKDMC and Saclay NaI experiments. The present analysis points to the necessity of taking into account surface nuclear and electron recoil interactions for a reliable estimate of background rejection factors.
[28]  oai:arXiv.org:astro-ph/9801199  [pdf] - 100048
Status of the EDELWEISS Experiment
Comments: 5 pages, 4 eps figures, LaTeX requires espcrc2.sty; Proceedings of TAUP97, Gran Sasso, Italy, September 7-11, 1997
Submitted: 1998-01-21
The status of the EDELWEISS experiment (underground dark matter search with heat-ionisation bolometers) is reviewed. Auspicious results achieved with a prototype 70 g Ge heat-ionisation detector under a 2 V reverse bias tension are discussed. Based on gamma and neutron calibrations, a best-case rejection factor, over the 15-45 keV range, of 99.7 % for gammas, with an acceptance of 94 % for neutrons, is presented first. Some operational results of physical interest obtained under poor low radioactivity conditions follow. They include a raw event rate of around 30 events/day/kg/keV over the same energy range, and, after rejection of part of the background, lead to a conservative upper limit on the signal of approximately 1.6 events/day/kg/keV at a 90 % confidence level. Performance degrading surface effects of the detector are speculated upon; and planned upgrades are summarized.