Chanumolu, Anantha
Normalized to: Chanumolu, A.
2 article(s) in total. 5 co-authors, from 1 to 2 common article(s). Median position in authors list is 1,0.
[1]
oai:arXiv.org:1701.02451 [pdf] - 1534334
Performance results of HESP physical model
Submitted: 2017-01-10
As a continuation to the published work on model based calibration technique
with HESP(Hanle Echelle Spectrograph) as a case study, in this paper we present
the performance results of the technique. We also describe how the open
parameters were chosen in the model for optimization, the glass data accuracy
and handling the discrepancies. It is observed through simulations that the
discrepancies in glass data can be identified but not quantifiable. So having
an accurate glass data is important which is possible to obtain from the glass
manufacturers. The model's performance in various aspects is presented using
the ThAr calibration frames from HESP during its pre-shipment tests. Accuracy
of model predictions and its wave length calibration comparison with
conventional empirical fitting, the behaviour of open parameters in
optimization, model's ability to track instrumental drifts in the spectrum and
the double fibres performance were discussed. It is observed that the optimized
model is able to predict to a high accuracy the drifts in the spectrum from
environmental fluctuations. It is also observed that the pattern in the
spectral drifts across the 2D spectrum which vary from image to image is
predictable with the optimized model. We will also discuss the possible science
cases where the model can contribute.
[2]
oai:arXiv.org:1505.00397 [pdf] - 987912
Modelling high resolution Echelle spectrographs for calibrations: Hanle
Echelle spectrograph, a case study
Submitted: 2015-05-03
We present a modelling scheme that predicts the centroids of spectral line
features for a high resolution Echelle spectrograph to a high accuracy. Towards
this, a computing scheme is used, whereby any astronomical spectrograph can be
modelled and controlled without recourse to a ray tracing program. The
computations are based on paraxial ray trace and exact corrections added for
certain surface types and Buchdahl aberration coefficients for complex modules.
The resultant chain of paraxial ray traces and corrections for all relevant
components is used to calculate the location of any spectral line on the
detector under all normal operating conditions with a high degree of certainty.
This will allow a semi-autonomous control using simple in-house, programming
modules. The scheme is simple enough to be implemented even in a spreadsheet or
in any scripting language. Such a model along with an optimization routine can
represent the real time behaviour of the instrument. We present here a case
study for Hanle Echelle Spectrograph. We show that our results match well with
a popular commercial ray tracing software. The model is further optimized using
Thorium Argon calibration lamp exposures taken during the preliminary alignment
of the instrument. The model predictions matched the calibration frames at a
level of 0.08 pixel. Monte Carlo simulations were performed to show the photon
noise effect on the model predictions.