Chamarthi, Sireesha
Normalized to: Chamarthi, S.
3 article(s) in total. 4 co-authors, from 1 to 3 common article(s). Median position in authors list is 1,0.
[1]
oai:arXiv.org:1906.05064 [pdf] - 1899454
Estimation and correction of the instrumental perturbations of Vainu
Bappu Telescope Echelle spectrograph using a model-based approach
Submitted: 2019-06-12
The Echelle spectrograph operating at Vainu Bappu Telescope (VBT), India, is
a general purpose instrument used for many high-resolution spectroscopic
observations. A concerted effort is being made to expand the scientific
capability of the instrument in emerging areas of observational astronomy. The
present study is aimed at evaluating the feasibility of the spectrograph to
carry out precision Radial Velocity (RV) measurements. In the current design,
major factors limiting the RV precision of the spectrograph arise from the
movable grating and slit; optical aberrations; positional uncertainty
associated with optomechanical mounts and environmental and thermal
instabilities in the spectrograph room. RV instabilities due to temperature and
pressure variations in the environment are estimated to vary around 120 $
\textrm{ms}^{-1} $ and 400 $ \textrm{ms}^{-1} $ respectively. The positional
uncertainty of the grating in the spectrograph could induce a spectral shift
$\sim1.4\,\textrm{kms}^{-1} $ across the Echelle orders. A Zemax model is used
to overcome the uncertainty in the zero-positioning and lack of repeatability
of the moving components. We propose to obtain the ThAr lamp observations and
using the Zemax model as the reference, predict the drifts in the positions of
the optical components. The perturbations of the optical components from the
nominal position are corrected at the beginning of the observational run. After
a good match is obtained between the model and the observations, we propose to
use a Zemax model to improve the wavelength calibration solution. We could
match the observations and model within $\pm$~1 pixels accuracy after the model
parameters were perturbed in a real-time setup of the spectrograph. In this
paper, we present the estimation of the perturbations of optical components and
the effect on the RV obtained.
[2]
oai:arXiv.org:1905.10539 [pdf] - 1889669
Toward precision radial velocity measurements using Echelle spectrograph
at Vainu Bappu Telescope
Submitted: 2019-05-25
The Echelle spectrograph operating at Vainu Bappu Telescope (VBT) is a
general purpose instrument designed for high resolution spectroscopy. It is
being considered for precision Doppler measurements without altering the
existing design and basic usage. However, the design level limitations and
environmental perturbations are a major source of instability and systematic
errors. As a result, a small Doppler signal in the stellar spectra is
completely swamped by the large and uncontrolled instrumental drift. In this
paper, we discuss some of the remedial measures we took to improve the radial
velocity performance of the spectrograph. We show that a new auto-guider
assembly has greatly reduced the mechanical jitter of the star image at the
fibre input, making the illumination of the spectrograph slit at the other end
stable. We have also installed an iodine absorption cell to track and eliminate
the instrumental drifts to facilitate precision radial velocity observations.
Furthermore, we have developed a generic algorithm that uses iodine exposures
to extract the stellar radial velocities without the need for the complex
forward modeling. Our algorithm is not accurate to the level of traditional
iodine technique. However it is convenient to use on a low-cost general-purpose
spectrograph targeting a moderate Radial Velocity (RV) precision at a few
10-100~$\textrm{ms}^{-1}$ level. Finally, we have demonstrated the usefulness
of our approach by measuring the RV signal of a well known short-period,
planet-hosting star.
[3]
oai:arXiv.org:1706.09202 [pdf] - 1585246
Stability analysis of VBT Echelle spectrograph for precise radial
velocity measurements
Submitted: 2017-06-28
A fiber-fed Echelle spectrograph at 2.3 m Vainu Bappu Telescope (VBT),
Kavalur, has been in operation since 2005. Owing to various technological
advancements in precision spectroscopy in recent years, several research
avenues have been opened in observational astronomy. These developments have
created a demand to improve the Doppler precision of our spectrograph.
Currently, the stability of the instrument is compromised by the temperature
and pressure fluctuations inside the Echelle room. Further, a better wavelength
calibration approach is needed to carefully track and disentangle the
instrumental effects from stellar spectra. While planning a possible upgrade
with an Iodine absorption gas cell, we measured the raw stability of the
spectrograph using a series of calibration frames taken with the ThAr gas
discharge lamp. The time series data were analysed with cross-correlation
method and the shift in ThAr emission lines was accurately measured across
different Echelle orders. In this paper, we present our stability analysis
methodology and results for the Kavalur spectrograph. We also identify possible
sources of error and discuss our strategy to mitigate them.